Class II (Laminar Flow) Biosafety Cabinetry
| Cabinet Style A = Bench Unit With Base or Adjustable Legs Provided B = Bench Unit Without Base or Adjustable Legs Provided C = Console |
Window Type H = Hinged S = Sliding F = Fixed |
Bench Height NA = Not Applicable NP = Not Provided |
CBV = Concurrent Balance Value
Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.
Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.
| Across International LLC | ![]() |
| 111 Dorsa Avenue | |
| Livingston, NJ 07039 | |
| United States | |
| 888-988-0899 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BC-2F[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| BC-3F[2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
| BC-4F[3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| BC-4FB2[4] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
| BC-6F[5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
Canopy connection model number is 2T-C.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2016. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
Canopy connection model number is 3T-C.
[3] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local
air density) was confirmed using manufacturer's recommended alternate method with
thermal anemometer in a constricted (3 inch high) access opening and applying
appropriate correction factor without adjusting cabinet airflow balance. The downflow
nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with
the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
Canopy connection model number is 4T-C.
[4] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2016. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. Canopy
connection model number is 6T-C.
|
|||||||||
| AirClean Systems | |
| 2179 East Lyon Station Road | |
| Creedmoor, NC 27522 | |
| United States | |
| (919) 255-3220 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| AC-36A2[1] [2] | A2 | A | 100 - 110 | 64 - 74 | N/A | 3 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
| AC-48A2[1] [3] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
| AC-72A2[1] [4] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
[1] This cabinet model was Certified for use with power supplies of 100V/60Hz, 115V/60Hz,
230V/50Hz, 230V/60Hz
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's
recommended alternate method with thermal anemometer in a constricted access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 69 fpm was established
U.V. Light removed. This cabinet is Certified to NSF/ANSI 49-2022. GFCI outlet is
approved for this model.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening (consult
manufacturer for appropriate correction factor, if applicable), without adjusting
cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light
removed.
This cabinet is Certified to NSF/ANSI 49-2019. GFCI outlet is approved for this model.
[4] Beginning with serial number BE0GGBEB200QHM7P0001. Inflow nominal set point of 105 fpm
was established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal
anemometer in a constricted access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 70 fpm was established U.V. Light removed. This cabinet is
Certified to NSF/ANSI 49-2019.
|
|||||||||
| Allentown, LLC | ![]() |
| Route 526 | |
| Allentown, NJ 08501-0698 | |
| United States | |
| 609-259-7951 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 39231xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39232xxx2 Safety Cab.[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39238xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39241xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39242xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39248xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39251xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39252xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39258xxx2 Safety Cab.[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39261xxx2 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39262xxx2 Safety Cab.[1] [4] | A2 | A | 100 - 110 | 45 - 55 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39268xxx2 Safety Cab.[1] [5] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39241[1] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39242xxx1 Safety Cab.[1] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39248[1] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39251[1] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39252xxx1 Safety Cab.[1] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39258[1] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39261[1] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39262xxx1 Safety Cab.[1] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 39268[1] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
[1] Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
measurement. This nominal set point was confirmed using the manufacturer's
recommended alternate method with thermal anemometer in a constricted access opening,
using the manufacturer-supplied probe holder and sash stop (consult manufacturer for
appropriate correction factor, if applicable), without adjusting cabinet
airflow balance. Downflow nominal set point of 55 fpm was established with I.V. pole
and U.V. light removed. This cabinet model was Certified to NSF/ANSI 49-2022.
This cabinet model is Certified for use with optional pre-filter, H14 filter, cable
pass-thru, service fixtures, KD base stand, hydraulic base stand, airflow Sensor, two
canopy models Ventus II 328202x.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for
appropriate correction factor, if applicable), without adjusting cabinet airflow
balance. Downflow nominal set point of 55 fpm was established with I.V. Pole and U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2022. This cabinet
model is Certified for use with optional sidewall pre-filter, H14 filter, ULPA filter,
cable pass-thru, service fixtures, KD base stand, hydraulic base stand, airflow Sensor,
two canopy models Ventus II 328202x.
[4] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 50 fpm was established with I.V. Pole and U.V. Light removed.
This cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified
for use with optional pre-filter, H14 filter, ULPA filter, canopy model Ventus II
328202x.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
measurement. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. pole and U.V. light removed. This
cabinet model was Certified to NSF/ANSI 49-2022.
This cabinet model is Certified for use with optional pre-filter, cable pass-thru,
service fixtures, KD base stand, hydraulic base stand, airflow Sensor, two canopy models
Ventus II 328202x.
NOTE: Bench stand models 51733xx, 51713xx, 518Z3xx, 51863xx may be used with cabinets in
the 39238xxx2/39231xxx2/39232xxx2 SC+ series.
Bench stand models 51734xx, 51714xx, 518Z4xx, 51864xx may be used with cabinets in the
39248xxx2/39241xxx2/39242xxx2 SC+ series.
Bench stand models 51735xx, 51715xx, 518Z5xx, 51865xx may be used with cabinets in the
39258xxx2/39251xxx2/39252xxx2 SC+ series.
Bench stand models 51736xx, 51716xx, 518Z6xx, 51866xx may be used with cabinets in the
39268xxx2/39261xxx2/39262xxx2 SC+ series.
All bench stand models beginning with 518 may be used with or without the optional wheel
kit (PN# 5190100).
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
measurement. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. pole and U.V. light removed. This
cabinet model was Certified to NSF/ANSI 49-2012. This cabinet model is Certified for use
with optional sidewall Vacu-PassTM Cord and Cable Portal.
[7] Inflow nominal set point of 105 fpm was established with a direct airflow reading
measurement. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. pole and U.V. light removed. This
cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for use
with optional sidewall Vacu-PassTM Cord and Cable Portal.
[8] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for use
with optional sidewall Vacu-PassTM Cord & Cable Portal.
|
|||||||||
| Baker Company, Inc. (The) | ![]() |
| 175 Gatehouse Road | |
| Sanford, ME 04073 | |
| United States | |
| 800-992-2537 | |
| 207-324-8773 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BCG401[1] | B2 | C | 100 - 110 | 35 - 45 | 664 @ 1.6 | 4 | 8S | 35 | I.V. Pole U.V. Light Casters |
| BCG601[1] | B2 | C | 100 - 110 | 35 - 45 | 993 @ 1.6 | 6 | 8S | 35 | I.V. Pole U.V. Light |
| SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 45 - 55 | N/A | 4 | 8S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 45 - 55 | N/A | 4 | 10S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 45 - 55 | N/A | 4 | 12S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG504[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 5 | 8S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG504[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 5 | 10S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG504[2] [3] [5] [7] | A2 | A | 100 - 110 | 43 - 53 | N/A | 5 | 12S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG604[2] [3] [5] [8] | A2 | A | 100 - 110 | 46 - 56 | N/A | 6 | 8S | 37 | Casters Canopy Connection I.V. Pole U.V. Light |
| SG604[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 6 | 10S | 37 | Casters Canopy Connection I.V. Pole U.V. Light |
| SG604[2] [3] [5] [9] | A2 | A | 100 - 110 | 40 - 50 | N/A | 6 | 12S | 37 | Canopy Connection Casters I.V. Pole U.V. Light |
[1] Beginning with serial number 103539 for the 4-foot model and serial number 103706 for
the 6-foot model. Inflow nominal setpoint of 105 fpm was established with a direct
airflow reading instrument. This nominal set point was confirmed using the
manufacturer's recommended alternate calculated method with thermal anemometer in a
constricted (3 inch high) access opening (consult manufacturer's operator's manual for
appropriate correction factor), without adjusting cabinet airflow balance. Downflow
nominal set point was established with I.V. Pole and U.V. Light removed. This cabinet
model was Certified to NSF/ANSI 49-2010a. This cabinet qualifies only with the armrest
installed. This cabinet is approved with additional petcocks on the sidewalls and a low
static pressure exhaust plenum. Cabinet models BCG401 INT and BCG601 INT are Certified
for alternate motor/blower combinations and input power supply.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate calculated method with thermal anemometer in a constricted (3 inch high)
access opening (consult manufacturer's operator's manual for appropriate correction
factor, if applicable).
[3] Baker model designations SG404-AUS and SG604-AUS are Certified to NSF/ANSI 49-2022 for
operation at 220V/50Hz with an 8-inch window opening. Baker model designations
SG404-INT, SG504-INT, and SG604-INT are Certified to NSF/ANSI 49-2022 for operation at
either 220V/50Hz or 220V/60Hz.
[4] Beginning with serial number 110235. Downflow nominal set point of 50fpm was established
with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2022. This cabinet qualifies only with the armrest installed. FlexAir Canopy
connection 333A745 is approved for use with this model.
[5] The maximum height for the fixed height stand with casters is 31 inches. The maximum
height for the adjustable height Channel stand, with bullet feet is 37 inches.
[6] Beginning with serial number 110795. Downflow nominal set point of 50 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
[7] Beginning with serial number 110795. Downflow nominal set point of 48 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
[8] Beginning with serial number 110555. Downflow nominal set point of 51 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
[9] Beginning with serial number 110555. Downflow nominal set point of 45 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
|
|||||||||
| Bioair S.p.A. | ![]() |
| Via Pagano, 61 | |
| 20145 Milan | |
| Italy | |
| 39 03 826 6721 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| SM-49 (Code: LDS4322)[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 35 | Canopy Connection Casters I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional touchscreen switch, petcock(s), cable ports(s), AZ1S304 Thimble
adapter canopy connection, a fixed stand with casters (Max Ht. 28"), an adjustable stand
with feet (Max Ht. 35"), and a hydraulic stand with casters (Max Ht. 35").
|
|||||||||
| CHC Biotech Co., Ltd. | ![]() |
| 2nd Floor of W1 Building | |
| 150 Gwahakseongjang-ro | |
| Yuseong-gu, Daejeon 305-500 | |
| Republic of Korea | |
| 82 42 936 5530 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| NB-704[1] [2] | A2 | A | 100 - 110 | 55 - 65 | 4 | 8S | 26 | I.V. Pole U.V. Light |
|
| NB-706[1] [2] | A2 | A | 100 - 110 | 55 - 65 | 6 | 8S | 26 | I.V. Pole U.V. Light |
|
[1] Certified for use with power supplies of 115V/60 Hz, 230V/50 Hz and 230V/60 Hz.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's alternate
recommended method with thermal anemometer in a constricted (3 inch high) access opening
consult manufacturer's operator's manual for appropriate correction factor), without
adjusting cabinet airflow balance. Downflow nominal set point was established with I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. This
cabinet qualifies only with the armrest installed.
|
|||||||||
| Chung Fu Technical Development Co., Ltd. | ![]() |
| 7F, No. 687, Mintsu East Road | |
| Taipei 105 | |
| Taiwan | |
| 886 2 2600 1761 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| AHA-133-AA-B[1] [2] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-AB-B[1] [2] [3] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-AC-B[1] [2] [4] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-CA-B[1] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-CB-B[1] [3] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-CC-B[1] [4] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-193-AA-A[2] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-AB-A[2] [3] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-AC-A[2] [4] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-CA-A[5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-CB-A[3] [5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-CC-A[4] [5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHB-133-AA-A[2] [7] | B2 | B | 100 - 110 | 54 - 64 | N/A | 4 | 8S | 34 | I.V. Pole U.V. Light |
| AHB-133-AB-A[2] [3] [7] | B2 | B | 100 - 110 | 54 - 64 | N/A | 4 | 8S | 34 | I.V. Pole U.V. Light |
| AHB-133-AC-A[2] [4] [7] | B2 | B | 100 - 110 | 54 - 64 | N/A | 4 | 8S | 34 | I.V. Pole U.V. Light |
[1] Beginning with serial number AHA1608060. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening and applying appropriate correction factor without adjusting cabinet
airflow balance. The downflow nominal set-point of 59 fpm was established 4 inches
above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
model was Certified to NSF/ANSI 49-2022. Chung Fu Technical Development Co., Ltd. Models
AHA-133-AA-B, AHA-133-AB-B, AHA-133-AC-B, AHA-133-CA-B, AHA-133-CB-B and AHA-133-CC-B
are marketed by Air Science, LLC, USA as Air Science Models AS-AHA-133-AA-B,
AS-AHA-133-AB-B, AS-AHA-133-AC-B, AS-AHA-133-CA-B, AS-AHA-133-CB-B and AS-AHA-133-CC-B,
respectively.
[2] Control panel is touch screen on this model.
[3] Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
[4] Certified for use with power supplies of 100V/50Hz and 100V/60Hz.
[5] Control panel is membrane switch on this model.
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. The downflow nominal set-point of 59 fpm was established 4 inches above the
bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
Certified to NSF/ANSI 49-2020. Chung Fu Technical Development Co., Ltd. Models
AHA-193-AA-A, AHA-193-AB-A,AHA-193-AC-A, AHA-193-CA-A, AHA-193-CB-A and AHA-193-CC-A are
marketed by Air Science, LLC, USA as Air Science Models AS-AHA-193-AA-A,
AS-AHA-193-AB-A, AS-AHA-193-AC-A, AS-AHA-193-CA-A, AS-AHA-193-CB-A and AS-AHA-193-CC-A,
respectively.
[7] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. The downflow nominal set-point of 59 fpm was established 4 inches above the
bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
Certified to NSF/ANSI 49-2022.
|
|||||||||
| Design Filtration Microzone Inc. | |
| 86 Harry Douglas Drive | |
| Ottawa, ON K2S 2C7 | |
| Canada | |
| 613-831-8318 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BK-3-4[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
| BK-3-6[2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| BK3-4[3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 27 | I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local
air density) was confirmed using manufacturer's recommended alternate method with
thermal anemometer in a constricted (3 inch high) access opening and applying
appropriate correction factor without adjusting cabinet airflow balance. The downflow
nominal set point of 65 fpm was established 4 inches above the bottom of the sash with
the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
Canopy connection model number is 4FT-CC.
[2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was
established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light
removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with
power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. Canopy connection model number is
6FT-CC.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set-point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set-point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2012. Approved for alternate power modes of 115V/60Hz, 220V/50Hz and 220V/60Hz.
Canopy connection model number is 4FE-CC.
|
|||||||||
| Esco Micro Pte Ltd | ![]() |
| 21 Changi South Street 1 | |
| 486777 | |
| Singapore | |
| 65 6542 0833 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| AC2-3E8-NS G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-3E9-NS G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-3J7 G4 8"[1] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-3N7 G4 8" [1] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-3S8-NS G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-3S9-NS G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-3Y7 G4 8"[1] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4E8-NS G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4E8-NS G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4E9-NS G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4E9-NS G4 8" [3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4J7 G4 10"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4J7 G4 8"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4N7 G4 10"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4N7 G4 8"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4S8-NS G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4S8-NS G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4S9-NS G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4S9-NS G4 8"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4Y7 G4 10"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-4Y7 G4 8"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5E8 NS G4 10"[2] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5E8-NS G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5E9 NS G4 10"[3] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5E9-NS G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5J7 G4 10"[4] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5J7 G4 8" [4] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5N7 G4 10"[4] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5N7 G4 8"[4] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5S8 NS G4 10"[2] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5S8-NS G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5S9 NS G4 10"[3] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5S9-NS G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5Y7 G4 10"[4] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-5Y7 G4 8"[4] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6E8-NS G4 10"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6E8-NS G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6E9-NS G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6E9-NS G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6J7 G4 10"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6J7 G4 8"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6N7 G4 10"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6N7 G4 8"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6S8-NS G4 10" [2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6S8-NS G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6S9-NS G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6S9-NS G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6Y7 G4 10"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AC2-6Y7 G4 8"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-3E8 G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-3E9 G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-3S8 G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-3S9 G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4E8 G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4E8 G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4E9 G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4E9 G4 8"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4S8 G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4S8 G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4S9 G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-4S9 G4 8"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5E8 G4 10"[2] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5E8 G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5E9 G4 10"[3] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5E9 G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5S8 G4 10"[2] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5S8 G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5S9 G4 10"[3] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-5S9 G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6E8 G4 10"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6E8 G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6E9 G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6E9 G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6S8 G4 10"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6S8 G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6S9 G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| AR2-6S9 G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-4J7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-4J7 G4 12"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| LA2-4J7 G4 8"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LA2-4N7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-4N7 G4 12"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| LA2-4N7 G4 8"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LA2-4S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-4S8 G4 12"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| LA2-4S8 G4 8"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LA2-4S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-4S9 G4 12"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| LA2-4S9 G4 8"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LA2-4Y7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-4Y7 G4 12"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| LA2-4Y7 G4 8"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LA2-5J7 G4 10"[4] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-5N7 G4 10"[4] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-5S8 G4 10"[2] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-5S9 G4 10"[3] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-5Y7 G4 10"[4] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6J7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6J7 G4 12"[4] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6N7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6N7 G4 12"[4] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6S8 G4 12"[2] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6S9 G4 12"[3] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6Y7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LA2-6Y7 G4 12"[4] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LB2-4B7 G4[4] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-4B8 G4[2] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-4B9 G4[3] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-4Y7 G4[4] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-4Y8 G4[2] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-4Y9 G4[3] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-6B7 G4[4] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-6B8 G4[2] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-6B9 G4[3] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-6Y7 G4[4] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-6Y8 G4[2] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LB2-6Y9 G4[3] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| LR2-4S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LR2-4S8 G4 12"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| LR2-4S8 G4 8"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LR2-4S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LR2-4S9 G4 12"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| LR2-4S9 G4 8"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LR2-5S8 G4 10"[2] [9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LR2-5S9 G4 10"[3] [9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LR2-6S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LR2-6S8 G4 12"[2] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LR2-6S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| LR2-6S9 G4 12"[3] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| VA2-4S8 G4 12"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| VA2-4S9 G4 12"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
| VA2-6S8 G4 12"[2] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| VA2-6S9 G4 12"[3] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022.
[2] Certified for use with a power supply of 230V/50Hz and 230V/60Hz.
[3] Certified for use with a power supply of 110V-120V/50Hz and 110V-120V/60Hz.
[4] Approved for alternate power modes of 100V/50Hz and 100V/60Hz.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2022.
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022.
[7] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2022.
[8] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2014.
[9] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2014.
[10] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 70 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2014.
[11] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020.
[12] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2022.
[13] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2024.
|
|||||||||
| Germfree Laboratories, LLC | ![]() |
| 4 Sunshine Boulevard | |
| Ormond Beach, FL 32174 | |
| United States | |
| 386-265-4360 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BSCA-4 | A2 | A | 100 - 110 | 54 - 64 54 - 64 40 - 50 |
N/A | 4 | 10S | 32 | I.V. Pole Canopy Connection |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. The acceptable non-uniform downflow ranges listed
above begin with zone 1 (54-64 fpm) closest to the back wall of the cabinet, zone 2
(54-64 fpm) center of the cabinet, and end with zone 3 (40-50 fpm) closest to the front
sliding window. Downflow nominal set points were established with the I.V. Pole
removed. This cabinet model was Certified to NSF/ANSI 49-2020. This cabinet qualifies
only with the armrest installed. Certified for use with a power supply of 100V/50Hz/60Hz
and 230V/50Hz/60Hz. Additional options are I.V. pole, canopy model BSCA-4C, casters and
modified-passthrough.
| iGene Labserve Private Limited | |
| 16/2, Ashok Nagar | |
| New Delhi | |
| 110018 | |
| India | |
| 91 11 79613060 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| IG-CIIA222G[1] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| IG-CIIA222N[1] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| IG-CIIA242G[2] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | U.V. Light Canopy Connection I.V. Pole |
| IG-CIIA242N[2] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | U.V. Light Canopy Connection I.V. Pole |
| IG-CIIB242G[3] [5] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | U.V. Light I.V. Pole |
| IG-CIIB242N[3] [5] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | U.V. Light I.V. Pole |
| IG-CIIA262G[4] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | U.V. Light Canopy Connection I.V. Pole |
| IG-CIIA262N[4] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | U.V. Light Canopy Connection I.V. Pole |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020. Certified canopy connection model is 2FT-CC.
[2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Certified canopy connection model is 4FT-CC.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2016.
[4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Certified canopy connection model is 6FT-CC.
[5] Certified for use with power supplies of 115V/60/Hz, 230V/50Hz and 230V/60Hz.
|
|||||||||
| Jinan Biobase Biotech Co., Ltd. | ![]() |
| North side of Jiwang Road, Mingshui | |
| Economic Dev. Zone, Zhangqiu Jinan | |
| Shandong Province 250200 | |
| China | |
| +86 531 67965823 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BSC-2FA2-GL[1] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| BSC-2FA2-NA[1] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| BSC-3FA2-GL[2] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
| BSC-3FA2-NA[2] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
| BSC-4FA2[3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 27 | I.V. Pole U.V. Light |
| BSC-4FA2-GL[4] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| BSC-4FA2-NA[4] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| BSC-4FB2-GL[5] [7] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
| BSC-4FB2-NA[5] [7] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
| BSC-6FA2-GL[6] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
| BSC-6FA2-NA[6] [7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020. Certified canopy connection model number is 2FT-CC.
[2] Beginning with serial number NA3FAT220600001AY. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2016. Certified canopy connection model
number is 3FT-CC.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal set
point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole
and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. Approved
for alternate power modes of 115V/60Hz, 220V/50Hz and 220V/60Hz. Certified canopy
connection model number is 4FE-CC.
[4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Certified canopy connection model number is 4FT-CC.
[5] Beginning with serial number 4FB18050001. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2016.
[6] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Certified canopy connection model number is 6FT-CC.
[7] Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
|
|||||||||
| Kewaunee Scientific Corporation | ![]() |
| 2700 West Front Street | |
| Statesville, NC 28677 | |
| United States | |
| 704-873-7202 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| INT-B1400-2[1] [2] | B2 | A | 100 - 110 | 55 - 65 | 937@2.4 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| INT-B2000-2[1] [2] | B2 | A | 100 - 110 | 55 - 65 | 1416@2.0 | 6 | 8S | 36 | I.V. Pole U.V. Light |
[1] Also Certified for use with power supplies of 230V/50Hz and 230V/60Hz. Model numbers may
be followed by -230 suffix.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was
established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to
NSF/ANSI 49-2016.
|
|||||||||
| Labconco Corporation | ![]() |
| 8845 Prospect | |
| Kansas City, MO 64132 | |
| United States | |
| 816-333-8811 X771 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 30231xxx2 Logic[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| 30232xxx2 Logic[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| 30238xxx2 Logic[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
| 30241xxx2 Logic[2] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30242xxx2 Logic[2] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30248xxx2 Logic[2] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30251xxx2 Logic[2] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
| 30252xxx2 Logic[2] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30258xxx2 Logic[2] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30261xxx2 Logic[2] [5] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30262xxx2 Logic[2] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30268xxx2 Logic[2] [5] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30348xxx2 Logic[2] [7] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 30368xxx2 Logic[2] [7] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 30441xxx1 Axiom[2] [9] | C1 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| 30448xxx1 Axiom[2] [9] | C1 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| 30461xxx1 Axiom[2] [9] | C1 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| 30468xxx1 Axiom[2] [8] | C1 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| 31232xxx2 PuriCare[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| 31242xxx2 PuriCare[2] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
| 31252xxx2 PuriCare[2] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31262xxx2 PuriCare[2] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30231xxx1 Logic+[10] [11] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30238xxx1 Logic+[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31231xxx1 PuriCare[10] [11] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30241xxx1 Logic+[10] [11] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30242xxx1 Logic+[2] [8] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30248xxx1 Logic+[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31241xxx1 PuriCare[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31242xxx1 PuriCare[2] [8] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30251xxx1 Logic+[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30252xxx1 Logic+[2] [12] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30258xxx1 Logic+[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31251xxx1 PuriCare[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31252xxx1 PuriCare[2] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30261xxx1 Logic+[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30262xxx1 Logic+[2] [8] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30268xxx1 Logic+[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31261xxx1 PuriCare[2] [10] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 31262xxx1 PuriCare[2] [8] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30348xxx1 Logic+[2] [10] | B2 | A | 100 - 110 | 50 - 60 | 852 @ 1.8 | 4 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
| 30368xxx1 Logic+[2] [10] | B2 | A | 100 - 110 | 50 - 60 | 1265 @ 2.2 | 6 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional pre-filter, cable pass-Thru, service fixtures, KD base stand,
hydraulic base stand, airflow Sensor, two canopy models Ventus 3282000 and Ventus II
3282010.
[2] Certified for use with power supplies of 100V/50 Hz, 100V/60 Hz, 230V/50 Hz, and 230V/60
Hz.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional pre-filter, cable pass-Thru, service fixtures, KD base stand,
hydraulic base stand, airflow Sensor, two canopy models Ventus 3282001 and Ventus II
3282011.
[4] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional pre-filter, cable pass-Thru, service fixtures, KD base stand,
hydraulic base stand, airflow Sensor, two canopy models Ventus 3282002 and Ventus II
3282012.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional pre-filter, cable pass-Thru, service fixtures, KD base stand,
hydraulic base stand, airflow Sensor, two canopy models Ventus 3282003 and Ventus II
3282013.
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 50 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional pre-filter, cable pass-Thru, service fixtures, KD base stand,
hydraulic base stand, airflow Sensor, two canopy models Ventus 3282003 and Ventus II
3282013.
[7] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional pre-filter, cable pass-Thru, service fixtures, KD base stand,
hydraulic base stand, and airflow Sensor.
[8] Beginning with serial number 151200002. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted access opening, using the manufacturer-supplied probe holder and sash
stop (consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2014. This cabinet model is Certified for use with optional sidewall Vacu-PassTM
Cord & Cable Portal.
[9] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for
use with optional sidewall Vacu-PassTM Cord & Cable Portal.
[10] Beginning with serial number 190500000. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted access opening, using the manufacturer-supplied probe holder and sash
stop (consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2016. This cabinet model is Certified for use with optional sidewall Vacu PassTM
Cord & Cable Portal.
[11] Certified for use with power supplies of 230V/50 Hz and 230V/60 Hz.
[12] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed.
This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified
for use with optional sidewall Vacu-PassTM Cord & Cable Portal.
[13] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using
the manufacturer-supplied probe holder and sash stop (consult manufacturer for
appropriate correction factor, if applicable), without adjusting cabinet airflow
balance. Downflow nominal set point of 65 fpm was established with I.V. Pole and U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model
is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal.
|
|||||||||
NOTE: Bench stand models 51733xx, 51713xx, 518Z3xx, 51853xx may be used with cabinets in the
30238xxx2/30231xxx2/30232xxx2 Logic series, and 31232xxx2 PuriCare.
Bench stand models 51734xx, 51714xx, 518Z4xx, 51854xx may be used with cabinets in the
30248xxx2/30241xxx2/30242xxx2 Logic series, and 31242xxx2 PuriCare.
Bench stand models 51735xx, 51715xx, 518Z5xx, 51855xx may be used with cabinets in the
30258xxx2/30251xxx2/30252xxx2 Logic series, and 31252xxx2 PuriCare.
Bench stand models 51736xx, 51716xx, 518Z6xx, 51856xx may be used with cabinets in the
30268xxx2/30261xxx2/30262xxx2 Logic series, and 31262xxx2 PuriCare.
Bench stand models 51734xx, 51714xx, 518Z4xx, 51854xx may be used with cabinets in the
30348xxx2 Logic series.
Bench stand models 51736xx, 51716xx, 518Z6xx, 51856xx may be used with cabinets in the
30368xxx2 Logic series.
All bench stand models beginning with 518 may be used with or without the optional wheel
kit (PN# 5190100).
NOTE: Bench stand models 3730300, 3730310, 3401003, 3780200 and 3780100 may be used with
cabinets in the 30231xxx1/30238xxx1 Logic series. Bench stand models 3730400, 3730410,
3401004, 3780201 and 3780101 may be used with cabinets in the 30241xxx1/30248xxx1/30242
Logic series and the corresponding PuriCare series. Bench stand models 3730500, 3730510,
3401005, 3780203, 3780106, 3780107, 3780312, and 3780316 may be used with cabinets in
the 30251xxx1/30258xxx1 Logic series. Bench stand models 3730600, 3630610, 3401006,
3780202 and 3780102 may be used with cabinets in the 30261xxx1/30268xxx1/30262 Logic
series and the corresponding PuriCare series. Bench stand models 3730400 and 34103003
may also be used with the 30348xxx1 Logic Series. Bench stand models 3730600 and
34103006 may also be used with the 30368xxx1 Logic Series. All bench stand models
beginning with 378 may be used with or without the optional wheel kit (PN# 3784000).
| MEDFUTURE LLC | ![]() |
| 3231 Osgood Common | |
| Freemont, CA 94539 | |
| United States | |
| 626-283-4740 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| B-IIA2-2F-GL[1] [2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| B-IIA2-2F-NA[1] [2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| B-IIA2-4F[3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 27 | I.V. Pole U.V. Light |
| B-IIA2-4F-GL[2] [4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| B-IIA2-4F-NA[2] [4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| B-IIA2-6F-GL[2] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| B-IIA2-6F-NA[2] [5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020. Canopy connection model number is 2A2T-CC.
[2] Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal set
point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole
and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. Approved
for alternate power modes of 115V/60Hz, 220V/50Hz and 220V/60Hz. Canopy connection model
number is 4A2E-CC.
[4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Canopy connection model number is 4A2T-CC.
[5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
setpoint of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Canopy connection model number is 6A2T-CC.
|
|||||||||
| Mystaire Inc. | |
| 1200 Telecom Drive | |
| Creedmoor, NC 27522 | |
| United States | |
| 919-229-8511 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| MY-24A2[1] [2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| MY-36A2[2] [3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | U.V. Light Canopy Connection I.V. Pole |
| MY-48A2[2] [4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | U.V. Light Canopy Connection I.V. Pole |
| MY-48B2[2] [5] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | U.V. Light I.V. Pole |
| MY-72A2[2] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | U.V. Light Canopy Connection I.V. Pole |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020. Canopy connection model number is 2FT-CC.
[2] Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2016. Canopy model 3FT-CC was evaluated as a part of the NSF Certification testing
procedures.
[4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Canopy model 4FT-CC was evaluated as a part of the NSF Certification testing procedures.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2016.
[6] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Canopy model 6FT-CC was evaluated as a part of the NSF Certification testing procedures.
|
|||||||||
| Nuaire, Inc. | ![]() |
| 2100 Fernbrook Lane | |
| Plymouth, MN 55447 | |
| United States | |
| 763-553-1270 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| NU-427-400[1] [2] [3] | B1 | A | 100 - 110 | 65 - 75 | 282 @ 0.7 | 4 | 8S | 32 | Bag-In/ Bag-Out I.V. Pole U.V. Light |
| NU-427-600[1] [2] [4] | B1 | A | 100 - 110 | 65 - 75 | 474 @ 0.9 | 6 | 8S | 32 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
| NU-540-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-540-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-540-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-540-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-540-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-540-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-540-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-540-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 35 | U.V. Light I.V. Pole Canopy Connection |
| NU-543-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-543-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-300[6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-300[6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-400[7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-400[7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-500[8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-500[8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-600[9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-545-600[9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
| NU-560-400[10] | B2 | A | 100 - 110 | 55 - 65 | 859@1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| NU-565-400[10] | B2 | A | 100 - 110 | 55 - 65 | 859@1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| NU-560-600[15] | B2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light |
| NU-565-600[15] | B2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light |
| NU-677-400[11] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 38 | Canopy Connection U.V. Light |
| NU-677-500[12] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 38 | Canopy Connection U.V. Light |
| NU-677-600[13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 12S | 38 | Canopy Connection U.V. Light |
| NU-FH677-500[14] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 38 | U.V. Light |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening for appropriate correction
factor, if applicable, without adjusting cabinet airflow balance.
[2] Listed model may be suffixed with E. Certified for use with power supplies of 230V/50Hz
and 230V/60Hz.
[3] Beginning with Series 60 and higher. Downflow nominal set-point of 70 fpm was
established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
removed. This cabinet model was Certified to NSF/ANSI 49-2011. This cabinet qualifies
with the optional DC motor installed. Listed model may be prefaced with Q, N, L or S
(i.e. NU-Q427-400).
[4] Beginning with series 40 and higher. Downflow nominal set-point of 60 fpm was
established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
removed. This cabinet qualifies with the optional DC motor installed.
Listed model may be prefaced with Q, N, L or S (i.e. NU-Q427-600). This cabinet model
was Certified to NSF/ANSI 49-2011.
[5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012.
Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Certified for use
with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.
[6] Beginning with serial number 170844102115. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening and applying appropriate correction factor without adjusting cabinet
airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches
above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
model was
Certified to NSF/ANSI 49-2014. Listed model may be prefaced with Q, N, L, or S
(e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz,
230V/50Hz, and 230V/60Hz.
[7] Beginning with serial number 170847102115. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening and applying appropriate correction factor without adjusting cabinet
airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above
the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
Certified to NSF/ANSI 49-2020. Listed model may be prefaced with Q, N, L, or S (e.g.
NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz,
and 230V/60Hz.
[8] Beginning with serial number 170845102115. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening and applying appropriate correction factor without adjusting cabinet
airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches
above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
model was Certified to NSF/ANSI 49-2014. Listed model may be prefaced with Q, N, L, or
S (e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz,
230V/50Hz, and 230V/60Hz.
[9] Beginning with serial number 170846102115. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening and applying appropriate correction factor without adjusting cabinet
airflow
balance. The downflow nominal set-point of 60 fpm was established 4 inches above the
bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
Certified to NSF/ANSI 49-2014. Listed model may be prefaced with Q, N, L, or S
(e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz,
230V/50Hz, and 230V/60Hz.
[10] Beginning with serial number 179773041817. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening and applying appropriate correction factor without adjusting cabinet
airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches
above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
model was Certified to NSF/ANSI 49-2016. Certified for use with power supplies of
115V/60Hz, 230V/50Hz and 230V/60Hz. The concurrent balance value was taken with the NSF
exhaust system conforming to ASHRAE. However, differences due to the exhaust system,
cabinet and instrumentation may be present and product specification information should
be obtained from the manufacturer.
[11] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2011. NuAire canopy
model NU-911-402 was evaluated as part of the NSF Certification testing procedures.
[12] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2011. NuAire canopy
model NU-911-502 was evaluated as a part of the NSF Certification testing procedures.
[13] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2011. NuAire canopy
model NU-911-602 was evaluated as part of the NSF Certification testing procedures.
[14] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. NuAire canopy model
NU-911-502 was evaluated as a part of the NSF Certification testing procedures.
NU-FH677-500 is a modified version of NU-677-500, including feed hoppers.
[15] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2022.
Certified for use with power supplies of 115V/60Hz.
|
|||||||||
| Qingdao Haier Biomedical Co., Ltd. | ![]() |
| No. 280 Fengyuan Road | |
| High-Tech Zone | |
| Qingdao 266111 | |
| China | |
| 86 176 6092 6003 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| HR900-IIA2-N[1] [2] | A2 | A | 100 - 110 | 64 - 74 | N/A | 3 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
| HR1200-IIA2-N[1] [3] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
| HR1800-IIA2-N[1] [4] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
| HR1500-IIA2-N[5] | A2 | A | 100 - 110 | 64 - 74 | N/A | 5 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
[1] This cabinet model was Certified for use with power supplies of 100V/60Hz, 115V/60Hz,
230V/50Hz, 230V/60Hz
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening (consult
manufacturer for appropriate correction factor, if applicable), without adjusting
cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light
removed. This cabinet is Certified to NSF/ANSI 49-2022. GFCI outlet is approved for this
model.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening (consult
manufacturer for appropriate correction factor, if applicable), without adjusting
cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light
removed.
This cabinet is Certified to NSF/ANSI 49-2019. GFCI outlet is approved for this model.
[4] Beginning with serial number BE0GGBEB200QHM7P0001. Inflow nominal set point of 105 fpm
was established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted access opening (consult manufacturer for appropriate correction factor,
if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of
70 fpm was established U.V. Light removed. This cabinet is Certified to NSF/ANSI 49-2019.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening (consult
manufacturer for appropriate correction factor, if applicable), without adjusting
cabinet airflow balance. Downflow nominal set point of 64 fpm was established U.V. Light
removed. This cabinet is Certified to NSF/ANSI 49-2022.This cabinet model was Certified
for use with power supplies of 100V50/60Hz, 115V/60Hz,230V/50/60Hz. GFCI outlet is
approved for this model.
|
|||||||||
| Suzhou Antai Airtech Co., Ltd. | ![]() |
| No. 2 Weixin Road, SIP | |
| Suzhou, Jiangsu 215122 | |
| China | |
| 86 512 6552 5002 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BSC-1301 II A2[1] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 10S | 24 | U.V. Light Canopy Connection |
| BSC-1302 II A2[1] [2] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 10S | 24 | U.V. Light Canopy Connection |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (80 mm high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 69 fpm was established 4 inches above the bottom of the sash with the U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Approved metric
value for cabinet width is 1270 mm, window height is 250 mm, and bench height max is 610
mm.
[2] Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
|
|||||||||
| Thermo Fisher Scientific | |
| Robert-Bosch-Str. 1 | |
| D-63505 Langenselbold | |
| Germany | |
| 49 61 813 5277 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 1574[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1579[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1584[1] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1589[1] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set-point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/
ANSI 49-2020. Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
Removable armrests with padded and non-padded designs in addition to dished and flat
work surface designs are approved options for this cabinet model.
[2] This model includes stainless steel interior cabinet walls with adjustable height stand.
Model can be provided with the standard Type I power cord and internal receptacles
(China electrical configuration with YY certification) and identified as 1574, and 1579;
with Type GP power cord and internal receptacles (China electrical configuration
without YY certification) and identified as 1574-GP, 1579-GP; with Type F power cord and
internal receptacles (Korea electrical configuration) and identified as 1574-F,
1579-F; with Type G power cord and internal receptacles (UK electrical configuration)
and identified as 1574-G, 1579-G; with Type M power cord and internal receptacles
(India electrical configuration) and identified as 1574-M, 1579-M; or with Type C fixed
height stand with castors and identified as 1574-C, 1579-C, 1574-FC, 1579-FC,
1574-GC, 1579-GC, 1574-MC, 1579-MC, 1574-C-GP, 1579-C-GP. 1546 and 1548 are the same
models as 1574 and 1579 without stands.
[3] This model includes coated steel (SmartCoat)interior cabinet walls with adjustable
height stand. Model can be provided with the standard Type I power cord and internal
receptacles (China electrical configuration with YY certification) and identified as
1584, 1589; with Type F power cord and internal receptacles (Korea electrical
configuration)and identified as 1584-F, 1589-F; with Type G power cord and internal
receptacles (UK electrical configuration) and identified as 1584-G, 1589-G; with Type
M power cord and internal receptacles (India electrical configuration) and identified as
1584-M, 1589-M; or with Type C fixed height stand with castors and identified as
1584-C, 1589-C, 1584-FC, 1589-FC, 1584-GC, 1589-GC, 1584-MC, 1589-MC. 1556 and 1558 are
the same models as 1584 and 1589 without stands.
|
|||||||||
Facility : Marietta, OH
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 1305[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1306[1] [2] [3] | A2 | A | 100 - 110 | 58 - 58 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1307[1] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1308[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1320[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1321[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1322[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1323[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest U.V. Light I.V. Pole |
| 1325[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1326[1] [2] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1327[1] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1328[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1330[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1331[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1332[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1333[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1335[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1336[1] [2] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1337[1] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1338[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1339[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1340[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1341[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1342[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1345[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1346[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1347[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1348[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1350[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1351[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1352[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1353[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1354[2] [11] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1355[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1356[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1357[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1358[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1359[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1366[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1367[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1368[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1369[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest U.V. Light I.V. Pole |
| 1370[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1371[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1372[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest U.V. Light I.V. Pole |
| 1373[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1375[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1376[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1377[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1378[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1380[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1381[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1382[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1383[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1384[2] [11] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1385[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1386[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1387[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1388[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1389[4] [11] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1390[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1391[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1392[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1393[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1395[2] [9] [12] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1396[1] [2] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1397[4] [9] [12] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1398[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1505A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1506A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1507A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1508A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1520A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1521A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1522A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1523A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1525A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1526A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1527A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1528A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1530A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1531A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1532A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1533A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1535A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1536A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1537A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1538A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1539A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1540A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1541A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1542A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1544A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1545A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1547A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1549A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1550A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1551A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1552A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1553A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1554A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1555A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1557A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1559A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1566A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1567A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1568A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1569A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1570A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1571A2[15] [17] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1572A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1573A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1575A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1576A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1577A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1578A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1580A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1581A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1582A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1583A2[15] [16] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1585A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1586A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1587A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1588A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1590A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1591A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1592A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1593A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1595A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1596A2[13] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1597A2[14] [15] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
| 1598A2[13] [14] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set-point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2009.
[2] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
base stand GT221189 along with 4ft cross brace GT221195 were approved for use with all
1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
for both stands.
[3] Certified for use with power supply of 230V/50Hz and 230V/60Hz.
[4] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
base stand GT221189 along with 6ft cross brace GT221196 were approved for use with all
1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
for both stands.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's alternate
recomended method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor), without
adjusting cabinet airflow balance. Downflow nominal set point was established with
I.V.Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2009.
[6] May be used with alternate, adjustable height electric stand (maximum bench height of 35
inches).
[7] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
base stand GT221189 along with 3ft cross brace GT221193 were approved for use with all
1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
for both stands.
[8] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2009. Certified for use with power supply of 230V/50Hz and 230V/60Hz.
[9] Certified for use with power supply of 220 V / 50 Hz and 220 V / 60 Hz.
[10] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
base stand GT221189 along with 5ft cross brace GT221197 were approved for use with all
1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
for both stands.
[11] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set-point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2009. Certified for use with power supply of 220V/50Hz.
[12] Beginning with serial number 188122-1 and 188108-1 for models 1395 and 1397,
respectively. Inflow nominal set-point of 105 fpm was established with a direct airflow
reading instrument. This nominal set point was confirmed using the manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening (consult manufacturer for appropriate correction factor, if applicable),
without adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was
established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to
NSF/ANSI 49-2009.
[13] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified with both
dished and flat work surfaces and for additional inlet power supplies of 230V/50Hz and
230V/60Hz. This cabinet model was Certified to NSF/ANSI 49-2022. 15xx models are
approved for use without armrests, with padded armrests, or with armrests without
padding.
[14] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified with both
dished and flat work surfaces. This cabinet model was Certified to NSF/ANSI 49-2022.
15xx models are approved for use without armrests, with padded armrests, or with
armrests without padding.
[15] May be used with manual adjustable height stand (maximum bench height of 35 inches),
electrical adjustable height stand (maximum bench height of 36 inches) and caster fixed
height stand GT221201. Casters GT221199 is an approved option.
[16] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified with both dished
and flat work surfaces and for additional inlet power supplies of 230V/50Hz and
230V/60Hz. This cabinet model was Certified to NSF/ANSI 49-2024. 15xx models are
approved for use without armrests, with padded armrests, or with armrests without
padding.
[17] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified with both
dished and flat work surfaces. This cabinet model was Certified to NSF/ANSI 49-2024.
15xx models are approved for use without armrests, with padded armrests, or with
armrests without padding.
|
|||||||||
Facility : Guangzhou, China
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 1574[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1584[1] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1579[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1589[1] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set-point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020. Certified for use with power supplies of 230V/50Hz and 230V/60Hz. Removable
armrests with padded and non-padded designs in addition to dished and flat work surface
designs are approved options for this cabinet model.
[2] This model includes stainless steel interior cabinet walls with adjustable height stand.
Model can be provided with the standard Type I power cord and internal receptacles
(China electrical configuration with YY certification) and identified as 1574, and 1579;
with Type GP power cord and internal receptacles (China electrical configuration without
YY certification) and identified as 1574-GP, 1579-GP; with Type F power cord and
internal receptacles (Korea electrical configuration) and identified as 1574-F, 1579-F;
with Type G power cord and internal receptacles (UK electrical configuration) and
identified as 1574-G, 1579-G; with Type M power cord and internal receptacles (India
electrical configuration) and identified as 1574-M, 1579-M; or with Type C fixed height
stand with castors and identified as 1574-C, 1579-C, 1574-FC, 1579-FC, 1574-GC, 1579-GC,
1574-MC, 1579-MC, 1574-C-GP, 1579-C-GP. 1546 and 1548 are the same models as 1574 and
1579 without stands.
[3] This model includes coated steel (SmartCoat)interior cabinet walls with adjustable
height stand. Model can be provided with the standard Type I power cord and internal
receptacles (China electrical configuration with YY certification) and identified as
1584, 1589; with Type F power cord and internal receptacles (Korea electrical
configuration)and identified as 1584-F, 1589-F; with Type G power cord and internal
receptacles (UK electrical configuration) and identified as 1584-G, 1589-G; with Type M
power cord and internal receptacles (India electrical configuration) and identified as
1584-M, 1589-M; or with Type C fixed height stand with castors and identified as 1584-C,
1589-C, 1584-FC, 1589-FC, 1584-GC, 1589-GC, 1584-MC, 1589-MC. 1556 and 1558 are the same
models as 1584 and 1589 without stands.
|
|||||||||
Facility : Langenselbold, Germany
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| HERAsafe 2030i 1.2[1] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| HERAsafe 2030i 1.8[1] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
[1] Beginning with serial number 42294669 for the HERAsafe 2030i 1.2 and serial number
42209172 for the HERAsafe 2030i 1.8. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set point of 63 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified with both dished and flat work surfaces and for additional
inlet power supplies of 230V/50Hz and 230V/60Hz. This cabinet model was Certified to
NSF/ANSI 49-2018. HERAsafe 2030i 1.2 is approved for use with either padded armrests or
armrests without padding. HERAsafe 2030i 1.8 is approved for use without armrests, with
padded armrests, or with armrests without padding.
|
|||||||||
[2] Beginning with serial number 40329642. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. This
cabinet model was Certified with a 3 section work surface. This cabinet model was
Certified to NSF/ANSI 49-2009.
| Thermo Fisher Scientific | |
| 401 Millcreek Road | |
| Marietta, OH 45750 | |
| United States | |
| 740-373-4763 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 1501B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1502B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1503B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1504B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1513B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1514B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1513B2F[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1513B2G[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1513B2M [1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1514B2F[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1514B2G[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1514B2M[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 818 @ 1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 1512B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1519B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1534B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1543B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1524B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1529B2[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1524B2F[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1524B2G[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1524B2M[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1529B2F[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1529B2G[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 1529B2M[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 1382 @ 2.5 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| 151x[2] [3] [4] | B2 | A | 100 - 110 | 50 - 60 | 852 @ 1.8 | 4 | 8S | 36 | Bag-In/ Bag-Out I.V. Pole U.V. Light |
| 156x[2] [3] [5] | B2 | A | 100 - 110 | 50 - 60 | 1265 @ 2.2 | 6 | 8S | 36 | Bag-In/ Bag-Out I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional pre-filter, cable pass-Thru, service fixtures, welded stand 3730402
(4ft) and 3730602 (6ft), and airflow Sensor.
[2] Certified for use with power supplies of 100V/50 Hz, 100V/60 Hz, 230V/50 Hz, and 230V/60
Hz.
[3] Beginning with serial number 190500000. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted access opening, using the manufacturer-supplied probe holder and sash
stop (consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2016. This cabinet model is Certified for use with optional cord & cable portal.
[4] Model 1511 is equivalent to Model 1510, but comes equipped with U.V. lighting (Listed as
an acceptable option). Model 1515 is equivalent to model 1510, but is rated for use
with power supplies of 230V and 50/60 Hz and is equipped with a Chinese-compatible plug.
Model 1516 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz
and is equipped with U.V. lighting and a Chinese-compatible plug. Model 1517 is
equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is
equipped with a North American 230 Volt-compatible plug. Model 1517F is equivalent, but
is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F
electrical plug (Schuko). Model 1517G is equivalent, but is rated for use with power
supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug
(UK-compatible). Model 1517M is equivalent, but is rated for use with power supplies of
230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible).
Model 1518 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz
and is equipped with U.V. lighting and a North American 230 Volt-compatible plug.Model
1518F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and
is equipped with a Type F electrical plug (Schuko). Model 1518G is equivalent, but is
rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G
electrical plug (UK-compatible). Model 1518M is equivalent, but is rated for use with
power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug
(India-compatible).
[5] Model 1561 is equivalent to Model 1560, but comes equipped with U.V. lighting (Listed as
an acceptable option). Model 1562 is equivalent to model 1560, but is rated for use
with power supplies of 230V and 50/60 Hz and is equipped with a Chinese-compatible plug.
Model 1563 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz
and is equipped with U.V. lighting and a Chinese-compatible plug. Model 1564 is
equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is
equipped with a North American 230 Volt-compatible plug. Model 1564F is equivalent, but
is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F
electrical plug (Schuko). Model 1564G is equivalent, but is rated for use with power
supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug
(UK-compatible). Model 1564M is equivalent, but is rated for use with power supplies of
230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible).
Model 1565 is equivalent, but is rated for use with power supplies of 230 V and 50/60 Hz
and is equipped with U.V. lighting and a North American 230 Volt-compatible plug. Model
1565F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and
is equipped with a Type F electrical plug (Schuko). Model 1565G is equivalent, but is
rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G
electrical plug (UK-compatible). Model 1565M is equivalent, but is rated for use with
power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug
(India-compatible).
|
|||||||||
| Thermolab Scientific Equipments Private Limited | |
| Thermolab House | |
| Plot No:19/20/40/41,Vasai Municipal Indu | |
| Umela Road Vasai, (West) District | |
| Palghar, MM 401207 | |
| India | |
| 91 744 7448880 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| Hyzone2002IIA2-NSA[1] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| Hyzone2002IIA2-NSG[1] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
| Hyzone2003IIA2-NSA[2] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
| Hyzone2003IIA2-NSG[2] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
| Hyzone2004IIA2-NSA[3] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| Hyzone2004IIA2-NSG[3] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
| Hyzone2004IIB2-NSA[4] [6] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
| Hyzone2004IIB2-NSG[4] [6] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
| Hyzone2006IIA2-NSA[5] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
| Hyzone2006IIA2-NSG[5] [6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer's operator's manual for appropriate correction factor) without
adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2020. Certified canopy connection model number is 2FT-CC.
[2] Beginning with serial number NA3FAT220600001AY. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2016. Certified canopy connection model
number is 3FT-CC.
[3] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Certified canopy connection model number is 4FT-CC.
[4] Beginning with serial number 4FB18050001. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2016.
[5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
Certified canopy connection model number is 6FT-CC.
[6] Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
|
|||||||||
Number of matching Manufacturers is 22