NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, June 21, 2018 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=044&Company=09460&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 44
Cation Exchange Water Softeners



 
Clack Corporation 
4462 Duraform Lane
Windsor, WI 53598-9716 
United States 
608-846-3010
Visit this company's website

Facility : Windsor, WI

             

COMPONENTS: Fittings[1] [Pb] [POE]
3/4" Brass Sweat Assembly LF - V3007-03LF[2]        
3/4" John Guest QC Elbow Assembly - V3007-15[2]        
3/4" John Guest QC Straight Assembly - V3007-19[2]        
3/4" Plastic Male BSPT Assembly - V3007-14[2]        
3/4" Plastic Male NPT Assembly - V3007-18[2]        
3/4" Sharkbite® Assembly - V3007-12LF[2]        
3/4" x 1" PVC Solvent Elbow Assembly - V3007-01[2]        
1" Brass Sweat Assembly LF - V3007-02LF[2]        
1" John Guest Straight QC Assembly - V3007-17[2]        
1" Meter Assembly - V3039[2]        
1" Meter Assembly - V3039-15[2]        
1" Plastic Male BSPT Assembly - V3007-06[2]        
1" Plastic Male NPT Assembly - V3007-04[2]        
1" PVC Male BSPT Elbow Assembly - V3007-16[2]        
1" PVC Male NPT Elbow Assembly - V3007[2]        
1" Sharkbite® Assembly - V3007-13LF[2]        
1.25" Plastic Male BSPT Assembly - V3007-08[2]        
1.25" Plastic Male NPT Assembly - V3007-05[2]        
1.25" & 1.5" Brass Sweat Assembly LF - V3007-09LF[2]        
1.25" & 1.5" PVC Solvent Assembly - V3007-07[2]        
Inline Vertical Adapter Fitting - V3467[2]        
Vertical Adapter Assembly - V3191-01[2]        

   
[1] Conforms to material and structural integrity requirements.
[2] Certified for use with tanks 9 x 48 and greater.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[POE] Product conforms to NSF/ANSI 61 health effects requirements.

COMPONENTS: Valves, Diverter, Point-of-Entry[1] [Pb] [POE]
1" Control Valve - V1AABCD-EFFGG[2] [3]        
1" Twin Control Valve - VTT1AABCD-EFFGG[2] [3]        
1" & 1.25" Motorized Alternating Valve - V3069MM-01[2]        
1" & 1.25" Motorized Alternating Valve - V3069FF-01[2]        
1" & 1.25" No Hard Water Bypass Valve - V3070FM[2]        
1" & 1.25" No Hard Water Bypass Valve - V3070FF[2]        
1.25" Control Valve - V125AABCD-EFFGG[2] [3]        
1191 In-Out Head - D1400[2]        
1190FP In-Out Head w/ Fill Port - D1220-01[2]        
Bypass Assembly - V3006[2]        
Bypass Assembly - V3006-XX[2] [4]        
External In-Line Mixing Valve - V4099[2]        

   
[1] Conforms to material and structural integrity requirements.
[2] Certified for use with tanks 9 x 48 and greater.
[3] V1AABCD-EFFGG, VTT1AABCD-EFFGG and V125AABCD-EFFGG where:
    AA - May be blank or any two digit letter code
    B  - May be D (downflow, U (upflow), or B (backwash only)
    C  - May be M (meter) or T (timer)
    D  - May be A, B, C, D, E, F, G, H, I, J, K, or Z to indicate the injector installed
    E  - May be blank or any letter code.  If E or M then it includes a mixing valve
    FF - May be any number from 01 to 99.  Indicates packaging or base variations
    GG - May be any two digit combination of letters.  If blank, cover is black or if filled
    in indicates colored covers or special labels on the cover.
[4] V3006-XX where XX may be 01, 02 or 04.  Indicates handle color, handle direction or
    packaging.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[POE] Product conforms to NSF/ANSI 61 health effects requirements.


Number of matching Manufacturers is 1
Number of matching Products is 34
Processing time was 0 seconds