NSF/ANSI 44
Cation Exchange Water Softeners
Cation Exchange Water Softeners
| Everpure LLC | ![]() |
| 1040 Muirfield Drive | |
| Hanover Park, IL 60133 | |
| United States | |
| 800-323-7873 | |
| Visit this company's website |
Facility : Buena Park, CA
| Flow Rate | ||||||
| Brand Name / Trade Name / Model | (gpm) | Claim | ||||
|
Plumbed-In[1] [Pb] |
||||||
| CES-5600E-15 | 3 | Efficiency Rated[ER] Hardness Reduction[HR] |
||||
|
  [1] Product evaluated and determined to comply with efficiency rating requirements defined
by California state laws.
[ER] Softener Efficiency indicates that the softener achieves a minimum of 3,350 grains of
hardness removed per pound of regenerant salt (477 grams of hardness removed per
kilogram of regenerant salt), and also that it uses 5 gallons or less of regenerant
water per 1,000 grains of hardness removed (18.9 liters or less of regenerant water per
64.8 grams of hardness removed).
[HR] Hardness Reduction indicates that the published capacity ratings for reducing hardness
have been verified.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Point-of-Entry[1] [POE] |
||||||
| CES-9100E-24[Pb] | 8 | Efficiency Rated[ER] Hardness Reduction[HR] |
||||
| CES-9100TS E-30C[Pb] | 7.9 | Efficiency Rated[ER] Hardness Reduction[HR] |
||||
|
  [1] Product evaluated and determined to comply with efficiency rating requirements defined
by California state laws.
[ER] Softener Efficiency indicates that the softener achieves a minimum of 3,350 grains of
hardness removed per pound of regenerant salt (477 grams of hardness removed per
kilogram of regenerant salt), and also that it uses 5 gallons or less of regenerant
water per 1,000 grains of hardness removed (18.9 liters or less of regenerant water per
64.8 grams of hardness removed).
[HR] Hardness Reduction indicates that the published capacity ratings for reducing hardness
have been verified.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.
|
||||||
Facility : Mukwonago, WI
| Flow Rate | ||||||
| Brand Name / Trade Name / Model | (gpm) | Claim | ||||
|
Plumbed-In[1] [Pb] |
||||||
| CES-5600E-15 | 3 | Efficiency Rated[ER] Hardness Reduction[HR] |
||||
|
  [1] Product evaluated and determined to comply with efficiency rating requirements defined
by California state laws.
[ER] Softener Efficiency indicates that the softener achieves a minimum of 3,350 grains of
hardness removed per pound of regenerant salt (477 grams of hardness removed per
kilogram of regenerant salt), and also that it uses 5 gallons or less of regenerant
water per 1,000 grains of hardness removed (18.9 liters or less of regenerant water per
64.8 grams of hardness removed).
[HR] Hardness Reduction indicates that the published capacity ratings for reducing hardness
have been verified.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Point-of-Entry[1] [POE] |
||||||
| CES-9100E-24[Pb] | 8 | Efficiency Rated[ER] Hardness Reduction[HR] |
||||
| CES-9100TS E-30C[Pb] | 7.9 | Efficiency Rated[ER] Hardness Reduction[HR] |
||||
|
  [1] Product evaluated and determined to comply with efficiency rating requirements defined
by California state laws.
[ER] Softener Efficiency indicates that the softener achieves a minimum of 3,350 grains of
hardness removed per pound of regenerant salt (477 grams of hardness removed per
kilogram of regenerant salt), and also that it uses 5 gallons or less of regenerant
water per 1,000 grains of hardness removed (18.9 liters or less of regenerant water per
64.8 grams of hardness removed).
[HR] Hardness Reduction indicates that the published capacity ratings for reducing hardness
have been verified.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[POE] Product conforms to NSF/ANSI 61 health effects requirements.
|
||||||
Number of matching Manufacturers is 1
Number of matching Products is 6
Processing time was 0 seconds