NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, September 29, 2016 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=053&Company=32730&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 53
Drinking Water Treatment Units - Health Effects



 
Multipure / Multipure Drinking Water Systems 
Las Vegas Technology Center
7251 Cathedral Rock Drive 
Las Vegas, NV 89128 
United States 
800-622-9206 
702-360-8880
Visit this company's website

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Counter-Top Connected to Sink Faucet [Pb]
CB-As-SC CBTAs 600(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-VOC-SC CBTVOC 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP750SC CB6 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Radon Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP880SC CB11As 600(1) 1   Asbestos Reduction
Arsenic (Pentavalent)<=50 ppb Reduction*
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MPAD CB6AD 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Radon Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MPADC CBTAD 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MPCT CB6 750 .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Radon Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plumbed-In to Separate Tap
CB-As-PB[Pb] CBNAs 600(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-As-PB-PID[Pb] CBNAs 960(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-As-SB[Pb] CBTAs 600(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-As-SB-PID[Pb] CBTAs 960(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-VOC-EL[Pb] CBTVOC 1200(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-VOC-SB[Pb] CBTVOC 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-VOC-SB-PID[Pb] CBTVOC 1200(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP1200EL[Pb] CB6 1200(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Radon Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP750 Plus RO CB6 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP750SB[Pb] CB6 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Radon Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP880EL[Pb] CB11As 960(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP880SB[Pb] CB11As 600(1) 1   Asbestos Reduction
Arsenic (Pentavalent)<=50 ppb Reduction*
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plumbed-In
AQUALUXE[Pb] CBLX 500(1) .75   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Radon Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-As-PI[Pb] CBNAs 600(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-As-SI[Pb] CBTAs 600(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
CB-VOC-SI[Pb] CBTVOC 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP750SI[2] [Pb] CB6 750(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Radon Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
MP880SI[2] [Pb] CB11As 600(1) 1   Asbestos Reduction
Arsenic (Pentavalent)<=50 ppb Reduction*
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Suffix I = Unit has no hardware;  appropriate for in line installation.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Number of matching Manufacturers is 1
Number of matching Products is 25
Processing time was 0 seconds