NSF Product and Service Listings
These NSF Official Listings are current as of Tuesday, April 1, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=058&Company=3D180&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
Vontron Technology Co., Ltd. | |
No.1518, Liyang Road, Guiyang National | ![]() |
High-Tech Industrial Development Zone | |
Guiyang, Guizhou | |
China | |
86 851 8627 0379 |
Facility : Guizhou, China
COMPONENTS: Membrane Elements[1] [2] |
||||||
ATOMBERG ULP2012 | ||||||
FZ3213-1000MXM | ||||||
HOR2012 | ||||||
HP1812-50 | ||||||
HP1812-75 | ||||||
HP2012-100 | ||||||
HR1812-100 | ||||||
HT3-1812-75 | ||||||
HT3-1812-80 | ||||||
HT3-2012-100 | ||||||
HT4-1812-100H | ||||||
HT4-2012-100 | ||||||
HT4-2012-75 | ||||||
M-100 | ||||||
M400-3012 | ||||||
M600-3012 | ||||||
M600-3013 | ||||||
M80 | ||||||
NATIVE-100-1812-HT3 | ||||||
PUREIT M80-E | ||||||
PUREIT ULP2012-100 | ||||||
PUREIT ULP2012-150 | ||||||
PUREIT ULP2012-175 | ||||||
Spirit-300HF | ||||||
Spirit-300HR | ||||||
ULP-80GPD-GT | ||||||
ULP1609-50F | ||||||
ULP1609-50P | ||||||
ULP1809-100Q | ||||||
ULP1809-50P | ||||||
ULP1809-50Q | ||||||
ULP1810-40 | ||||||
ULP1810-50 | ||||||
ULP1810-50P | ||||||
ULP1810-50Q | ||||||
ULP1810-70 | ||||||
ULP1812-100 | ||||||
ULP1812-100 | ||||||
ULP1812-24 | ||||||
ULP1812-36 | ||||||
ULP1812-50 | ||||||
ULP1812-75 | ||||||
ULP1812-80 | ||||||
ULP1812-80Plus | ||||||
ULP1812-80Pro | ||||||
ULP1812-85 | ||||||
ULP1812-90Plus | ||||||
ULP1812-90Pro | ||||||
ULP2008-50P | ||||||
ULP2010-100Q | ||||||
ULP2010-80 | ||||||
ULP2012-100 | ||||||
ULP2012-125 | ||||||
ULP2012-150 | ||||||
ULP2012-200 | ||||||
ULP2012-40 | ||||||
ULP2012-50 | ||||||
ULP2809-200 | ||||||
ULP2812 | ||||||
ULP3012 | ||||||
ULP3012-300 | ||||||
ULP3012-400 | ||||||
ULP3012-600 | ||||||
ULP3012-700 | ||||||
ULP3012-800 | ||||||
ULP3013-400 | ||||||
ULP3013-500 | ||||||
ULP3013-600 | ||||||
ULP3013-800 | ||||||
ULP3020 | ||||||
ULP3113-1000 | ||||||
ULP3113-800 | ||||||
ULP3312-1000 | ||||||
ULP3312-800 | ||||||
ULP80-H | ||||||
VC1812-80G | ||||||
VM-TFC-80 | ||||||
VNF-1812 | ||||||
VNF-2012 | ||||||
VNF-2812 | ||||||
VNF2812-300 | ||||||
XLP2012-50 | ||||||
  [1] Certified to Standard 58, material requirements only. Membranes require a 24-hour flushing before use. [2] ULP/HORXXYY-ZZ ULP/HOR - Type of membrane sheet ULP: Regular ultra-low pressure residential element HOR: High-oxidation-resistant residential element XX - Membrane element diameter in inches 18 - 1.8" 20 - 2.0" 28 - 2.8" 30 - 3.0" YY - Membrane element length in inches (10", 12", 20") ZZ - Permeated flow in gallons per day (GPD) (24, 36, 50, 75, 100, or 150) ULP/HOR/XLP/VNFXXYY-ZZ-P/Q/F ULP/HOR/XLP/VNF - Type of membrane sheet ULP: Regular ultra-low pressure residential element HOR: High-oxidation-resistant residential element XLP - extremely low pressure VNF - Nanofiltration Membrane XX - Membrane element diameter in inches 16 - 1.6" 18 - 1.8" 20 - 2.0" 28 - 2.8" 30 - 3.0" YY - Membrane element length in inches (8", 9" 10", 12", 13", 20") ZZ - Permeated flow in gallons per day (GPD) (24, 36, 50, 75, 100, or 150) P - The center tube is even to the membrane. (Please see marked up model P) Q - Denotes special customer identification. F - Indicates the brine seal and the feed water direction are opposite compared to the general model Spirit, VC, VM, GT - Client code HP - high performance HR - high rejection HF - high flow M - membrane |
NOTE: All membranes are components.
Number of matching Manufacturers is 1
Number of matching Products is 82
Processing time was 0 seconds