NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
FilmTec Corporation | |
5400 Dewey Hill Road | |
Edina, MN 55439 | |
United States | |
952-897-4269 | |
Visit this company's website |
Facility : # 1 China
COMPONENTS: RO Membrane[1] |
||||||
DuPont™ TapTec™ TT Plus HF | ||||||
  [1] Certified for material requirements only. |
Facility : # 1 Thailand
COMPONENTS: RO Membrane |
||||||
DuPont™ TapTec™ TT Plus HF |
Facility : # 2 USA
COMPONENTS: Flat Sheet Membranes[1] |
||||||
BW30 (168881)[Pb] | ||||||
BW30 (366479)[Pb] | ||||||
BW30LE (366481)[Pb] | ||||||
Membrane XLE 37.0 RLC[4] [5] [Pb] | ||||||
TW60 35.0 (99052932) | ||||||
XLE (216818)[4] [5] [Pb] | ||||||
XLE (365877)[4] [5] [Pb] | ||||||
XLP (12086217)[Pb] | ||||||
XLP (99025011)[Pb] | ||||||
eXLE (99110343)[2] [3] [Pb] | ||||||
  [1] Conforms to material requirements only. [2] Conforms to material requirements only. Membrane requires a 24 hour flushing and conditioning prodecure. [3] Certified for a maximum surface area to volume ratio of 2.65 square feet/L. [4] This membrane is Certified at a maximum surface area of 5.5 square feet/L. [5] This flatsheet is used in a membrane that is associated with a Data Transfer Protocol. Please contact manufacturer for additional details. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
COMPONENTS: Membrane Elements[2] |
||||||
AQUALAST™ 1812-HR (11112537)[6] [Pb] | ||||||
BW60-1812-75[Pb] | ||||||
BW60-1812-75 (11018585)[7] [Pb] | ||||||
BW60-1812-75 (GMID 99017671)[7] [Pb] | ||||||
M-T1812A100 (12027533)[6] [Pb] | ||||||
TW30-1812-100HR (11013537)[6] [Pb] | ||||||
TW30-1812-50HR (99101033)[6] [Pb] | ||||||
  [2] Conforms to material requirements only. Membrane requires a 24 hour flushing and conditioning prodecure. [6] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228, Selenium, Turbidity, and TDS. The test data results may be transferred to other manufacturer's systems, if the systems meet the requirements contained on the document entitled, "Data Transfer Procedure for Devices using Filmtec Reverse Osmosis", dated 12/19/2011. This document is available from FilmTec. [7] BW60-1812-75 (11018585) and BW60-1812-75 (GMID 99017671) has been tested for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228, Selenium,Turbidity, and TDS. The test data results may be transferred to other manufacturer's systems, if the systems meet the requirements contained on the document entitled, "DataTransfer Procedure for Devices using Filmtec Reverse Osmosis", dated 08/13/2010. This document is available from FilmTec. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : # 4 China
COMPONENTS: RO Membrane |
||||||
TapTec™ XMF RO Flatsheet |
Number of matching Manufacturers is 1
Number of matching Products is 20