CSA Standard B483.1
Drinking Water Treatment Systems
Drinking Water Treatment Systems
| Pentair Residential Filtration, LLC | |
| 13845 Bishops Drive | |
| Suite 200 | |
| Brookfield, WI 53005 | |
| United States | |
| 800-279-9404 | |
| 262-238-4400 |
Facility : Roselle, IL
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In to Separate Tap |
||||||
| Everpure Residential H-1200 | H-1200 #1 H-1200 #2 |
1000(1) | .5 | Chloramine Reduction Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction Cyst Reduction Lead Reduction MTBE Reduction VOC Reduction ** |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Dover, NH
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Replacement Element: Plumbed-In |
||||||
| LR-FB10[1] | N/A | 1500(1) | 2.5 | Chlorine Reduction Taste and Odor Reduction Cyst Reduction Lead Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [1] Pentair LR-1500 |
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Chardon, OH
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In to Separate Tap [G] |
||||||
| Rainsoft Ultrefiner Elite | 52633 | 225(1) | 1 | Chloramine Reduction Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction Cyst Reduction VOC Reduction ** Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction Microplastics Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
|
Point-of-Entry[G] [POE] |
||||||
| RainSoft EC5-FLT 100 H LINKED | N/A | 100,000 | 8.6 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft EC5-FLT 100 SH EPA LINKED | N/A | 4,000 | 5.6 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft EC5-FLT 150 H LINKED | N/A | 150,000 | 8.6 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft EC5-FLT 75 H LINKED | N/A | 75,000 | 5.4 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft EC5-FLT 75 SH EPA LINKED | N/A | 2,930 | 5.4 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft QRS 1044 H | N/A | 249,746 | 7.7 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft QRS 1044 SH EPA | N/A | 4,415 | 5.6 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft QRS 1054 H | N/A | 330,022 | 8.6 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft QRS 844 H | N/A | 160,551 | 5.4 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft QRS 844 SH EPA | N/A | 2,796 | 5.4 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft QRS Upflow 1044 H | N/A | 124,873 | 7.7 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft QRS Upflow 844 H | N/A | 80,775 | 5.4 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft TC-FLT 100 H | N/A | 100,000 | 8.6 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft TC-FLT 150 H | N/A | 150,000 | 8.6 | Chlorine Reduction Taste and Odor Reduction |
||
| RainSoft TC-FLT 75 H | N/A | 75,000 | 5.4 | Chlorine Reduction Taste and Odor Reduction |
||
|
  [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Jiangsu Province, China
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In to Separate Tap [G] |
||||||
| Pentair F2000-B2B | F2B2-RC2 | 675(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Nominal Particulate Reduction, Class I Lead Reduction Taste and Odor Reduction |
||
| Pentair F3000-B2B | F2B2-RC2 | 675(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Nominal Particulate Reduction, Class I Lead Reduction Taste and Odor Reduction |
||
| Pentair GRO-350B[1] | FDF1-RC | 750 | .75 | Chlorine Reduction Taste and Odor Reduction |
||
| Pentair GRO-475B[1] | FDF1-RC F1B1-RC |
750(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Lead Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
| Pentair GRO-475BP[1] | FDF1-RC F1B1-RC |
750(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Lead Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
| Pentair GRO-575B[1] | FDF1-RC F2B2-RC2 F2B1-RC |
675(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Lead Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[1] Model is a reverse osmosis system and is also Certified to NSF/ANSI 58.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
|
COMPONENTS: Filter Housings[2] |
||||||
| Pentair 158006 | ||||||
| Pentair 158125 | ||||||
| Pentair 158125WM | ||||||
| Pentair 158196 | ||||||
| Pentair 158739 | ||||||
| Pentair 158739WM | ||||||
|
  [2] Conforms to material and structural integrity requirements only. |
||||||
[3] OmniFilter OT32
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Reynosa, Mexico
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In [G] |
||||||
| Pentair LR-1500 | LR-FB10 | 1500(1) | 2.5 | Chlorine Reduction Taste and Odor Reduction Lead Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
|
COMPONENTS: Filter Housings[2] |
||||||
| Pentair 150067 | ||||||
| Pentair 150069 | ||||||
| Pentair 150071 | ||||||
| Pentair 150164 | ||||||
| Pentair 150166 | ||||||
| Pentair 150233[G] | ||||||
| Pentair 150234[G] | ||||||
| Pentair 150237[G] | ||||||
| Pentair 150238[G] | ||||||
| Pentair 150437 | ||||||
| Pentair 158205 | ||||||
| Pentair R50067[G] | ||||||
| Pentair R50069[G] | ||||||
| Pentair R50071-75[G] | ||||||
|
  [2] Conforms to material and structural integrity requirements only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Chardon, OH
| Flow Rate | ||||||
| Brand Name / Trade Name / Model | (gpm) | Claim | ||||
|
Point-of-Entry [G] [POE] |
||||||
| Rainsoft EC4 100 CV[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC4 100 V[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC4 100S CV[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC4 100S V[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC4 150 CV[1] | 10.4 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC4 150 V[1] | 9 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC4 75 CV[1] | 9.2 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC4 75 V[1] | 8.6 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100 CT[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100 CV[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100 T[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100 V[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100S CT[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100S CV[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100S T[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 100S V[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 150 CT[1] | 9.6 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 150 CV[1] | 10.4 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 150 T[1] | 9.6 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 150 V[1] | 9 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 250 CT[1] | 11.2 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 250 CV[1] | 10.5 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 250 T[1] | 11.4 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 250 V[1] | 10.4 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 50SS CT | 10 | Barium Reduction Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 50SS CV[1] | 9.5 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 50SS T | 10 | Barium Reduction Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 50SS V[1] | 9.5 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 75 CT | 9.4 | Barium Reduction Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 75 CV[1] | 9.2 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 75 CV[1] | 9.2 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 75 T | 10 | Barium Reduction Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft EC5 75 V[1] | 8.6 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC 75 CV | 9.2 | Barium Reduction Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC 75 V | 8.6 | Barium Reduction Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC- M 50SS D[1] | 9.5 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 100 CD[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 100 CV[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 100 D[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 100S CD[1] | 10 | Barium Reduction Hardness Reduction Radium 226/228 Reduction Efficiency Rated |
||||
| Rainsoft TC-M 100S D[1] | 10 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 150 CD[1] | 10.4 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 150 CV[1] | 10.4 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 150 D[1] | 9 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 50SS CD[1] | 9.5 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 75 CD[1] | 9.2 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 75 CV[1] | 9.2 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
| Rainsoft TC-M 75 D[1] | 8.6 | Barium Reduction Efficiency Rated Hardness Reduction Radium 226/228 Reduction |
||||
|
  [1] Product evaluated and determined to comply with efficiency rating requirements defined
by California State laws.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.
|
||||||
[ER] Softener Efficiency indicates that the softener achieves a minimum of 3,350 grains of
hardness removed per pound of regenerant salt (477 grams of hardness removed per
kilogram of regenerant salt), and also that it uses 5 gallons or less of regenerant
water per 1,000 grains of hardness removed (18.9 liters or less of regenerant water per
64.8 grams of hardness removed).
[HR] Hardness Reduction indicates that the published capacity ratings for reducing hardness
have been verified.
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Dover, NH
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Replacement Element: Plumbed-In |
||||||
| LR-FB20BB[3] [G] | N/A | 35000(1) | 10 | Lead Reduction | ||
| PB35-10[4] [G] | N/A | 17500(1) | 5 | Lead Reduction | ||
| PB55-20[5] [G] | N/A | 35000(1) | 10 | Lead Reduction | ||
| Pentair Floplus 10[6] [G] | N/A | (1) | 5 | Cyst Reduction | ||
| Pentair Floplus 20[7] [G] | N/A | (1) | 10 | Cyst Reduction | ||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[3] Pentair LR-BB50
[4] OmniFilter PB35
[5] OmniFilter PB55
[6] Pentair FPS-10
[7] Pentair FPS-20
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
[2] Pentair LR-BB25
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Reynosa, Mexico
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In |
||||||
| Pentair FPS-10[G] | Floplus 10 | (1) | 5 | Cyst Reduction | ||
| Pentair FPS-20[G] | Floplus 20 | (1) | 10 | Cyst Reduction | ||
| Pentair LR-BB50[G] | LR-FB20BB | 35000(1) | 10 | Lead Reduction | ||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Hanover Park, IL
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Everpure Residential ROM IV[G] | ROM-PRE ROM-G75 ROM-PST ROM-PFK |
14.66 | Arsenic (Pentavalent)<=300 ppb Reduction Barium Reduction Cadmium Reduction Copper Reduction Cyst Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction Turbidity Reduction |
|||
|
  [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Roselle, IL
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Everpure Residential ROM IV[G] | ROM-G75 ROM-PFK ROM-PRE ROM-PST |
14.66 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Chardon, OH
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap[G] |
||||||
| Rainsoft Ultrefiner Elite | 51565 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
|
  [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
* This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic.
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Jiangsu Province, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap[G] |
||||||
| Pentair GRO-2550 | GS10-RO P5 EPM-10 GRO-50EN |
10.09 | Cyst Reduction TDS Reduction |
|||
| Pentair GRO-350B | FDF1-RC GRO50-RC F1GC-RC |
14.96 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| Pentair GRO-475B | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
30.57 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-475BP | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
94.38 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-575B | FDF1-RC GRO75-RC F2B2-RC2 F1GC-RC F2B1-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair RO-2550 | EPM-10 GS-10RO P5 TLC-50 |
15.04 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol