NSF Product and Service Listings
These NSF Official Listings are current as of Wednesday, December 3, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=058&Company=C0243494&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
| KeenSen Technology Co., Ltd. | |
| No. 370, Minghu Road | |
| Yuelu District | |
| Hunan | |
| China | |
| 86 731 8997 2869 | |
| Visit this company's website |
Facility : Hunan, China
|
COMPONENTS: Membrane Elements |
||||||
| RO-1512-50[1] [2] | ||||||
| RO-1809[1] [2] | ||||||
| RO-1810[1] [2] | ||||||
| RO-1812-100S[1] [2] | ||||||
| RO-1812-150S [1] [2] | ||||||
| RO-1812-35[1] [2] | ||||||
| RO-1812-50[1] [2] | ||||||
| RO-1812-50S[1] [2] | ||||||
| RO-1812-75[1] [2] | ||||||
| RO-1812-75-2[1] [2] | ||||||
| RO-1812-75A[1] [2] | ||||||
| RO-1812-75S [1] [2] | ||||||
| RO-1812-80[1] [2] | ||||||
| RO-1812-LE[1] [2] | ||||||
| RO-2009[1] [2] | ||||||
| RO-2010[1] [2] | ||||||
| RO-2012-100[1] [2] | ||||||
| RO-2012-100-2[1] [2] | ||||||
| RO-2012-100-3[1] [2] | ||||||
| RO-2012-100S[1] [2] | ||||||
| RO-2012-125-2[1] [2] | ||||||
| RO-2012-150[1] [2] | ||||||
| RO-2012-150-2[1] [2] | ||||||
| RO-2012-150S[1] [2] | ||||||
| RO-2012-200[1] [2] | ||||||
| RO-2012-200S[1] [2] | ||||||
| RO-2012-HR[1] [2] | ||||||
| RO-2809[1] [2] | ||||||
| RO-2812-200[1] [2] | ||||||
| RO-3012-300[1] [2] | ||||||
| RO-3012-400[1] [2] | ||||||
| RO-3012-400A[1] [2] [3] | ||||||
| RO-3012-500[1] [2] [3] | ||||||
| RO-3012-600[1] [2] [3] | ||||||
| RO-3012-700[1] [2] [3] | ||||||
| RO-3012-800[1] [2] [3] | ||||||
| RO-3013-400[1] [2] [3] | ||||||
| RO-3013-400A[1] [2] [3] | ||||||
| RO-3013-400S[1] [2] [3] | ||||||
| RO-3013-600[1] [2] [3] | ||||||
| RO-3013-600S [1] [2] [3] | ||||||
| RO-3013-700[1] [2] [3] | ||||||
| RO-3013-800[1] [2] [3] | ||||||
| RO-3013-800S[1] [2] [3] | ||||||
| RO-3020-600[1] [2] | ||||||
| RO-3020-600[1] [2] | ||||||
| RO-3213-1000[1] [2] [3] | ||||||
| RO-3213-600[1] [2] [3] | ||||||
| RO-3213-800[1] [2] | ||||||
| RO-3213-800[1] [2] | ||||||
| SHF1812-100[1] [2] | ||||||
| SHF2012-200[1] [2] | ||||||
| SHF3012-800[1] [2] | ||||||
| SHF3013-400[1] [2] | ||||||
| SHF3013-600[1] [2] | ||||||
| SHF3013-800[1] [2] | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, pH
value 3 ~ 8, flushing at least 48 hours.
[2] RO-XXYY-ZZ
XX - Membrane element diameter in inches
15 - 1.5"
18 - 1.8"
20 - 2.0"
28 - 2.8"
30 - 3.0"
32 - 3.2"
YY - Membrane element length in inches (12", 13")
ZZ - Permeated flow in gallons per day (GPD) (50, 75, 100, 150, 300, 400, 500, 600, 700
and 800)
[3] Certified to Standard 58, material requirements only. Flush for 24 hours.
|
||||||
|
COMPONENTS: RO Membrane[4] |
||||||
| ULP | ||||||
|
  [4] Certified for a maximum usage of 0.88 m²/L |
||||||
Number of matching Manufacturers is 1
Number of matching Products is 57
Processing time was 0 seconds

