NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
| Hydronix Water Technology | |
| 8630 Rochester Avenue | |
| Rancho Cucamonga, CA 91730 | |
| United States | |
| 909-527-6996 | |
| Visit this company's website |
Facility : 1C
|
COMPONENTS: Membrane Pressure Vessels[2] |
||||||
| MH03-1812WH | ||||||
|
  [2] Conforms to material and structural integrity requirements only.
NOTE: These components do not bear the NSF Mark. Evidence of Certification will appear
on the manufacturer's literature and packaging.
|
||||||
|
Plumbed-In to Separate Tap |
||||||
| Hydro Guard HDGT-45XX[3] | HDGT-SED5 HDGT-CB5 HDGT-TW50 C HDGT-CB5P |
20.1 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[3] XX= Faucet Finish
AB - Antique Brass
AW - Antique Wine
BK - Black
BN - Brushed Nickle
CP - Chrome Plated
IV - Ivory
ORB - Oil Rubbed Bronze
SN - Satin Nickle
WH - White
|
||||||
[1] Associated with a data transfer protocol. Test data results may be transferred to other
manufacturer's systems if the systems meet requirements contained on the document
entitled, "Data Transfer Procedure for Devices using Hydrondix Reverse Osmosis." This
document is available from Hydronix Water Technology.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
Facility : 3C
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Replacement Element: Plumbed-In to Separate Tap [Pb] |
||||||
| HDGT-TW50 C[1] [2] [3] | N/A | 17 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Associated with a data transfer protocol. Test data results may be transferred to other
manufacturer's systems if the systems meet requirements contained on the document
entitled, "Data Transfer Procedure for Devices using Hydrondix Reverse Osmosis." This
document is available from Hydronix Water Technology.
[2] Hydro Guard HGDT-45CP
[3] Certified for a max usage of 1 UNIT/14.4L (0.07 UNITS/L)
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Number of matching Manufacturers is 1
Number of matching Products is 3