NSF Product and Service Listings

These NSF Official Listings are current as of Saturday, November 23, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?CompanyName=filmtec&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects


 
Swun Chyan GROUP (Swun Yuan / Swun Yuan Filmtech) Enterprises Co., Ltd. 
No. 16, Lane 73, Liougu Road
Wufong Hsiang 
Taichung 41359 
Taiwan 
886 4 2333 7226
Visit this company's website

Facility : 1A - Taiwan

 
           

COMPONENTS: Filter Cartridges
1FCTO-LL-WX-ZZZ[4] [9] [11] [Pb]  
F-K33-12-GAC[1]  
F-K33-YY-GAC-Q[1] [2]  
F-T33-YY-GAC[1] [2] [3]  
F-T33-YY-GAC-Q[1]  
F-UDF-WW-LL[4] [5]  
F-UDFB-WW-LL[4] [6]  
FBC-LL-WX-ZZZ[7] [8]  
FCTO-LL-WX-ZZZ[4] [9] [12] [Pb]  
FDX-LL-WX-ZZZ[7] [8]  
FGC-LL-WX-ZZZ[7] [8]  
FPC1-LL-XW[4] [10]  
FPC2-LL-XW[4] [10]  
FPP-LL-WX-ZZZ[7] [8]  
Swun Yuan FBC-LL-WX-ZZZ[7] [8]  
Swun Yuan FDX-LL-WX-ZZZ[7] [8]  
Swun Yuan FGC-LL-WX-ZZZ[7] [8]  
Swun Yuan FPP-LL-WX-ZZZ[7] [8]  

   
[1] Conforms to the material and structural integrity requirements only.
[2] YY - Length (5", 6", 10", 11")
[3] Q - Quick Connect.
[4] Certified for material requirements only.
[5] F-UDF-WW-LL where:
    WW - Outer Diameter (in)
    LL - Length (in)
    Outer Diameter of 2.81in can have a length of 5 in, 9 in, 9.5 in, 10 in, and 20 in.
    Outer Diameter of 2.82in can have a length of 5 in, 9 in, 9.5 in, 10 in, and 20 in.
[6] F-UDFB-WW-LL where:
    WW - Outer Diameter (in)
    LL - Length (in)
    Outer diameter of 4.6 in, has length of 10 in or 20 in.
[7] Conforms to material requirement only.
[8] Where:
    LL  - Length 1" - 70"
    W   - Outer diameter 36 mm - 180 mm
    X   - Inner diameter 20 mm - 120 mm
    ZZZ - Retention rating 1 micron - 100 micons
[9] LL - Length (100-1004 mm)
    W - Outer Diameter (30-105 mm)
    X - Inner Diameter (13-50 mm)
    ZZZ - Retention Rating (0.5 - 10 um)
    Inner Diameter of 30mm has outer diameter of 63.5mm, has length of 5, 10, 20,30 or 40
    inches. Inner Diameter of 38mm has Outer Diameter of 63mm, has length of 10 , 20,30 or
    40 inches, Inner Diameter of 42mm has Outer Diameter of 69mm, has length of 10 or 20,30
    or 40 inches, Inner Diameter of 50mm has outer diameter of 105mm, has length of 10, 20
    inches.
[10] LL - Length (5, 10, or 20 in) (when X = 63, 67 or 72 mm LL = 5, 10 or 20 in and when X
     = 113 mm LL = 10 or 20 in)
     X - Outer Diameter (63, 67, 72 or 113 mm)
     W - Inner Diameter (28 mm)
     Micron Rating - 0.5, 1, 5, 10, 25, or 50 um
[11] 1FCTO-228.4-6338-ZZZ Tested in a system at a flow rate of 1.0 gpm to a capacity of 6,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42.
     1FCTO-254-6338-ZZZ Tested in a system at a flow rate of 1.0 gpm to a capacity of 6,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-508-6338-ZZZ Tested in a system at a flow rate of 2.0 gpm to a capacity of 12,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-127-6338-ZZZ Tested in a system at a flow rate of 0.5 gpm to a capacity of 3,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-241-6338-ZZZ Tested in a system at a flow rate of 1.0 gpm to a capacity of 5,600
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-762-6338-ZZZ Tested in a system at a flow rate of 3.0 gpm to a capacity of 18,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-254-10550-ZZZ Tested in a system at a flow rate of 2.0 gpm to a capacity of 14,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-381-10550-ZZZ Tested in a system at a flow rate of 3.0 gpm to a capacity of 21,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-1016-10550-ZZZ Tested in a system at a flow rate of 4.0 gpm to a capacity of
     24,000 gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-508-10550-ZZZ Tested in a system at a flow rate of 4.0 gpm to a capacity of 28,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
[12] FCTO-228.4-6338-ZZZ Tested in a system at a flow rate of 1.0 gpm to a capacity of 6,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42.
     FCTO-254-6338-ZZZ Tested in a system at a flow rate of 1.0 gpm to a capacity of 6,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     FCTO-508-6338-ZZZ Tested in a system at a flow rate of 2.0 gpm to a capacity of 12,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     FCTO-127-6338-ZZZ Tested in a system at a flow rate of 0.5 gpm to a capacity of 3,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     FCTO-241-6338-ZZZ Tested in a system at a flow rate of 1.0 gpm to a capacity of 5,600
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     FCTO-762-6338-ZZZ Tested in a system at a flow rate of 3.0 gpm to a capacity of 18,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     FCTO-254-10550-ZZZ Tested in a system at a flow rate of 2.0 gpm to a capacity of 14,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     FCTO-381-10550-ZZZ Tested in a system at a flow rate of 3.0 gpm to a capacity of 21,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     FCTO-1016-10550-ZZZ Tested in a system at a flow rate of 4.0 gpm to a capacity of 24,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
     1FCTO-508-10550-ZZZ Tested in a system at a flow rate of 4.0 gpm to a capacity of 28,000
     gal for the reduction of Chlorine and Taste & Odor per NSF/ANSI 42
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Taichung, Taiwan

 
           

COMPONENTS: Filter Housings[1]
EG1-14WW  
YT-10BL  
YT1-05BL  
YT1-05WW  
YT1-14BL  
YT1-14WW  
YTB-10BB  
YTB-10BL  
YTB-10GB  
YTB-10WB  
YTB-10WW  
YTB-15BL  
YTB-15GB  
YTB-15WB  
YTB-20BB  
YTB-20BL  
YTB-20GB  
YTB-20WB  
YTB-20WW  

   
[1] Conforms to material and structural integrity requirements only.

COMPONENTS: Fittings
0HLDQ04WH04  
0HLDQ06WH04  

NOTE: These components do not bear the NSF Mark.  Evidence of Certification will appear on the
      manufacturer's literature and packaging.

NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



 
FilmTec Corporation 
5400 Dewey Hill Road
Edina, MN 55439 
United States 
952-897-4269
Visit this company's website

Facility : # 1 China

             

COMPONENTS: RO Membrane[1]
DuPont™ TapTec™ TT Plus HF    

   
[1] Certified for material requirements only.


Facility : # 1 Thailand

             

COMPONENTS: RO Membrane
DuPont™ TapTec™ TT Plus HF    


Facility : # 2 USA

             

COMPONENTS: Flat Sheet Membranes[1]
BW30 (168881)[Pb]    
BW30 (366479)[Pb]    
BW30LE (366481)[Pb]    
Membrane XLE 37.0 RLC[4] [5] [Pb]    
TW60 35.0 (99052932)    
XLE (216818)[4] [5] [Pb]    
XLE (365877)[4] [5] [Pb]    
XLP (12086217)[Pb]    
XLP (99025011)[Pb]    
eXLE (99110343)[2] [3] [Pb]    

   
[1] Conforms to material requirements only.
[2] Conforms to material requirements only.  Membrane requires a 24 hour flushing and
    conditioning prodecure.
[3] Certified for a maximum surface area to volume ratio of 2.65 square feet/L.
[4] This membrane is Certified at a maximum surface area of 5.5 square feet/L.
[5] This flatsheet is used in a membrane that is associated with a Data Transfer Protocol. 
    Please contact manufacturer for additional details.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

COMPONENTS: Membrane Elements[2]
AQUALAST™ 1812-HR (11112537)[6] [Pb]    
BW60-1812-75[Pb]    
BW60-1812-75 (11018585)[7] [Pb]    
BW60-1812-75 (GMID 99017671)[7] [Pb]    
M-T1812A100 (12027533)[6] [Pb]    
TW30-1812-100HR (11013537)[6] [Pb]    
TW30-1812-50HR (99101033)[6] [Pb]    

   
[2] Conforms to material requirements only.  Membrane requires a 24 hour flushing and
    conditioning prodecure.
[6] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
    (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228, Selenium,
    Turbidity, and TDS.  The test data results may be transferred to other manufacturer's
    systems, if the systems meet the requirements contained on the document entitled, "Data
    Transfer Procedure for Devices using Filmtec Reverse Osmosis", dated 12/19/2011.  This
    document is available from FilmTec.
[7] BW60-1812-75 (11018585) and BW60-1812-75 (GMID 99017671) has been tested for the
    reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
    Copper, Fluoride, Lead, Radium 226/228, Selenium,Turbidity, and TDS.  The test data
    results may be transferred to other manufacturer's systems, if the systems meet the
    requirements contained on the document entitled, "DataTransfer Procedure for Devices
    using Filmtec Reverse Osmosis", dated 08/13/2010.  This document is available from
    FilmTec.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : # 4 China

             

COMPONENTS: RO Membrane
TapTec™ XMF RO Flatsheet    



 
Swun Chyan GROUP (Swun Yuan / Swun Yuan Filmtech) Enterprises Co., Ltd. 
No. 16, Lane 73, Liougu Road
Wufong Hsiang 
Taichung 41359 
Taiwan 
886 4 2333 7226
Visit this company's website

Facility : 1A - Taiwan

             

COMPONENTS: RO Membrane[1] [2]
TW-WWLL-ZZZVVV    

   
[1] Certified for material requirements only.
[2] TW  - Fixed code
    WW  - 1.8 - 3.5 Membrane element diameter in inches
    LL  - 7-13 Membrane element length in inches
    ZZZ - 020-1000 GPD
    VVV - Vendor Code

COMPONENTS: RO Tank, Low Pressure[3]
Z-TK022    
Z-TK032    

   
[3] Certified for material and structural integrity requirements only.


Facility : Taichung, Taiwan

             

COMPONENTS: Fittings
0HLDQ04WH04    
0HLDQ06WH04    

COMPONENTS: Membrane Pressure Vessels[1]
RO1-0001W    

   
[1] Conforms to material and structural integrity requirements only.

NOTE: These components do not bear the NSF Mark.  Evidence of Certification will appear on the
      manufacturer's literature and packaging.

Number of matching Manufacturers is 3
Number of matching Products is 65
Processing time was 0 seconds