NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, November 21, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?ProductFunction=058%7CNitrate%2FNitrite+Reduction&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
A.O. Smith Water Treatment (North American), Inc. | |
1900 Prospect Court | |
Appleton, WI 54914 | |
United States | |
800-777-1426 | |
920-739-9401 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
AORO-50 | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Aqua Systems | |
7785 East US Highway 36 | |
Avon, IN 46123 | |
United States | |
317-272-3000 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
AQPC-35[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
AQPC-435[2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Serial number of 180000 or higher. [2] As of 05/28/2004. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Atlantic Filter Corporation | |
3112 45th Street | |
West Palm Beach, FL 33407 | |
United States | |
561-683-0101 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
HR-35-TFC-4W[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] As of 05/28/2004. [2] Serial number of 180000 or higher. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
EcoWater Systems LLC | |
P.O. Box 64420 | |
St. Paul, MN 55164 | |
United States | |
800-869-2837 | |
Visit this company's website |
Facility : Iuka, MS
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap |
||||||
ERO-385[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
ERO-385-BN[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
ERO-385-CP[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
ERO-385E[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
ERO-385E-BN[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
ERO-385E-CP[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
HERO-385-BN[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
HERO-385-CP[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
HERO-385PLUS[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Model has a post filter that is also Certified to NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
GE Appliances, a Haier Company | |
Appliance Park | |
AP2-120 | |
Louisville, KY 40225 | |
United States | |
800-952-5039 | |
502-452-5435 |
Facility : Iuka, MS
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
GNRQ18NBN[1] | FQ18MN FQ18PN |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Asbestos Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
GXRQ18NBN[1] | FQ18MN FQ18PN |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Asbestos Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
GXRV40TBN | FQ18PN FQ18MN |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Asbestos Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Hellenbrand Inc. | |
404 Maravian Valley Road | |
P.O. Box 187 | |
Waunakee, WI 53597-0187 | |
United States | |
608-849-3050 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
Millennium MRO-35[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
Millennium MRO-35GF[2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Serial number of 180000 or higher. [2] As of 05/28/2004. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Hydronix Water Technology | |
8630 Rochester Avenue | |
Rancho Cucamonga, CA 91730 | |
United States | |
909-527-6996 | |
Visit this company's website |
Facility : 1C
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap |
||||||
Hydro Guard HDGT-45XX[3] | HDGT-SED5 HDGT-CB5 HDGT-TW50 C HDGT-CB5P |
20.1 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [3] XX= Faucet Finish AB - Antique Brass AW - Antique Wine BK - Black BN - Brushed Nickle CP - Chrome Plated IV - Ivory ORB - Oil Rubbed Bronze SN - Satin Nickle WH - White |
[1] Associated with a data transfer protocol. Test data results may be transferred to other manufacturer's systems if the systems meet requirements contained on the document entitled, "Data Transfer Procedure for Devices using Hydrondix Reverse Osmosis." This document is available from Hydronix Water Technology. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act.
Facility : 3C
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Replacement Element: Plumbed-In to Separate Tap [Pb] |
||||||
HDGT-TW50 C[1] [2] [3] | N/A | 17 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Associated with a data transfer protocol. Test data results may be transferred to other manufacturer's systems if the systems meet requirements contained on the document entitled, "Data Transfer Procedure for Devices using Hydrondix Reverse Osmosis." This document is available from Hydronix Water Technology. [2] Hydro Guard HGDT-45CP [3] Certified for a max usage of 1 UNIT/14.4L (0.07 UNITS/L) [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Lancaster Water Treatment | |
1340 Manheim Pike | |
Lancaster, PA 17601-3196 | |
United States | |
717-397-3521 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
Brita Pro BPLRO-35 | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
CRO-350 | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
LRO-35[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
PRO-50 | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] As of 05/28/2004. [2] Serial number of 180000 or higher. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Marlo Incorporated | |
2227 South Street | |
P.O. Box 044170 | |
Racine, WI 53404-7003 | |
United States | |
262-681-1300 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
TFC-35[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
TFC-35M[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] As of 05/28/2004. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Master Water Conditioning, Inc. | |
224 Shoemaker Road | |
Pottstown, PA 19464 | |
United States | |
610-323-8358 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
Puro-35T[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] As of 05/28/2004. [2] Serial number of 180000 or higher. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Microline | |
4462 Duraform Lane | |
Windsor, WI 53598-9716 | |
United States | |
608-846-3010 |
Facility : Windsor, WI
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
T.F.C.-335[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-335FS[1] | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-335FSX[2] | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-335X[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-3PL[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-3PLX[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-435[1] [2] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-435FFSX | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
T.F.C.-435FSX | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
T.F.C.-435RC | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-435X[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-4PL[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-4PLF[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
T.F.C.-4PLX[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] As of 05/28/2004. [2] Serial number of 180000 or higher. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Pentair Residential Filtration, LLC | |
13845 Bishops Drive | |
Suite 200 | |
Brookfield, WI 53005 | |
United States | |
800-279-9404 | |
262-238-4400 |
Facility : Jiangsu Province, China
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
Pentair GRO-350B | FDF1-RC GRO50-RC F1GC-RC |
14.96 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] ROR2000 is a replacement kit containing RS14, CB1, and two o-rings. [2] ROR2050 is a replacement kit containing R200, CB1, RS14, and two o-rings. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NOTE: These components do not bear the NSF Mark. Evidence of Certification will appear on the manufacturer's literature and packaging.
Rayne Corporation | |
4635 Ruffner Street | |
San Diego, CA 92111 | |
United States | |
858-292-1011 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
RaynePure Plus[1] [2] | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] As of 05/28/2004. [2] Serial number of 180000 or higher. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Senwater Systems, LLC. | |
Twentieth Floor | |
1300 East Ninth Street | |
Cleveland, OH 44114 | |
United States | |
216-262-0802 | |
Visit this company's website |
Facility : Windsor, WI
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
DRO512 | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
TRO508 | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
TRO510 | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Solventum Purification Inc. | |
400 Research Parkway | |
Meriden, CT 06450 | |
United States | |
800-222-7880 | |
651 737 1374 | |
Visit this company's website |
Facility : Stafford Springs, CT
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Replacement Element: Plumbed-In to Separate Tap |
||||||
3MRO501[G] | 3MROP411 3MROP412 3MROM413 3MROP416 |
23.92 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
The LeverEdge | |
1423 Gunn Highway | |
Odessa, FL 33556-5304 | |
United States | |
813-403-5100 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [1] [Pb] |
||||||
AvantaPure RO-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Lead Reduction |
|||
MAYTAG DRINKING WATER SYSTEM MODEL M-550 | S1340RSX-LEM | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
Pro Elite RO-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
Pro Elite RO-450 With Monitor | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
Westinghouse Drinking Water System A-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
Westinghouse Drinking Water System D-550 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
Westinghouse Drinking Water System P-550 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction TDS Reduction Selenium Reduction |
|||
Westinghouse Drinking Water System R-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] As of 05/28/2004. [2] S1340RSX-LE consists of a S1340RS, a sump and an o-ring. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Water Channel Partners | |
1890 Woodlane Drive | |
Woodbury, MN 55125 | |
United States | |
800-869-2837 |
Facility : # 3 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [1] [Pb] |
||||||
Brita Total360 BRDROS | BRDROF BRDROM |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
Ecodyne ELXROTU | ELXRM14 | 14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
Ecopure ECOP30 | ECOROM | 14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
North Star NSRO42C4 | 7287514 | 14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
North Star NSROPS | NSROPF | 14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
Whirlpool WHAPSRO | WHEERF WHEERM |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
Whirlpool WHAROS5 | WHEERF WHEERM |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
Whirlpool WHER25 | WHEERF WHEERM |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Model has a post filter that is also Certified to NSF/ANSI Standard 42. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
* This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic.
Water-Right / WaterCare | |
1900 Prospect Court | |
Appleton, WI 54914 | |
United States | |
920-739-9401 |
Facility : # 1 USA
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Plumbed-In to Separate Tap [Pb] |
||||||
UltroWater[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
Water-Right® WRO-35[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Serial number of 180000 or higher. [2] As of 05/28/2004. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 18
Number of matching Products is 65
Processing time was 0 seconds