NSF Product and Service Listings

These NSF Official Listings are current as of Tuesday, July 26, 2016 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=042&Company=13790&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects

NOTE: All Replacement Elements Are Components.


 
Doulton Water Filters 
Unit 4 Lymedale Cross Industrial Estate
Newcastle-Under-Lyme 
Staffordshire ST5 9BT 
United Kingdom 
44 1782 664430
Visit this company's website

Facility : Staffordshire, United Kingdom

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
Ecofast Biotect Ultra Inline[Pb] Biotect Ultra
W9123050
600 .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Ecofast Supercarb Inline[Pb] W9122021
Supercarb
1000(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Ecofast Ultracarb Inline[Pb] W9123053
Ultracarb
600(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
HIP-CT Biotect Ultra[Pb] Biotect Ultra
W9123050
600 .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
HIP-CT Biotect Ultracarb[Pb] Biotect
Ultracarb
W9123070
600 .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
HIP/Sterasyl Inline[Pb] W9120562
Sterasyl
(1) 1.05   Nominal Particulate Reduction, Class I
HIP/Supercarb Inline[Pb] W9122021
Supercarb
1000(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
HIP/Ultracarb Inline[Pb] W9123053
Ultracarb
600(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
HIP Biotect Ultra Inline[Pb] Biotect Ultra
W9123050
600 .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
QT Supercarb Inline[Pb] W9122021
Supercarb
1000(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
QT Ultracarb Inline[Pb] W9123053
Ultracarb
600(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Replacement Element: Plumbed-In to Separate Tap [2] [Pb]
Biotect Ultra W9123050[3] N/A 600(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Biotect Ultracarb W9123070[4] N/A 600(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Sterasyl W9120562[5] N/A (1) 1.05   Nominal Particulate Reduction, Class I
Supercarb W9122021[6] N/A 1000(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Ultracarb W9123053[7] N/A 600(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Conforms to material requirements.
[3] Compatible with the following systems: Ecofast Biotect Ultra Inline; HIP Biotect Ultra
    Inline; HIP-CT Biotect Ultra
[4] Compatible with the following system: HIP-CT Biotect Ultracarb
[5] Compatible with the following system: HIP/Sterasyl Inline
[6] Compatible with the following systems: Ecofast Supercarb Inline; HIP/Supercarb Inline;
    QT Supercarb Inline
[7] Compatible with the following systems: Ecofast Ultracarb Inline; HIP/Ultracarb Inline;
    QT Ultracarb Inline
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

COMPONENTS: Filter Cartridges[2]
Standard  

   
[2] Conforms to material requirements.


Number of matching Manufacturers is 1
Number of matching Products is 17
Processing time was 0 seconds