NSF Product and Service Listings
These NSF Official Listings are current as of Tuesday, April 28, 2020 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=058&hdModlStd=ModlStd&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
| 3M Purification Inc. | |
| 400 Research Parkway | |
| Meriden, CT 06450 | |
| United States | |
| 800-222-7880 | |
| 651 737 1374 | |
| Visit this company's website |
Facility : Stafford Springs, CT
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In |
||||||
| SGLP100-CL | HF65-CL CFS M |
30.99 | TDS Reduction | |||
| SGLP200-CL | HF65-CL CFS M |
61.97 | TDS Reduction | |||
|
Replacement Element: Plumbed-In to Separate Tap |
||||||
| 3MRO501 | 3MROP411 3MROP412 3MROP413 3MROP416 |
23.92 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| FSTM075 | ScaleGard Pre ScaleGard RO |
25.87 | TDS Reduction | |||
| SGLP-RO | ScaleGard Pre ScaleGard RO |
53 | TDS Reduction | |||
| SGLP-RO-NP | ScaleGard RO | 53 | TDS Reduction | |||
| SQC Pro | 47-55702G2 47-55704G2 47-55710G2 66-4706G2 |
23.92 | TDS Reduction | |||
| SQC Pro Unit Only | 47-55702G2 47-55704G2 47-55710G2 66-4706G2 |
36.78 | TDS Reduction | |||
|
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. |
||||||
Facility : Nuevo Leon, Mexico
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| 3MRO301 | 3MROP310 3MROP316 3MROM413 |
8.28 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| 3MRO401 | 3MROP411 3MROP412 3MROM413 3MROP416 |
8.28 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| CMTRO-3TFC | 47-55706G2 66-4706G2 |
11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| CMTRO-75 | 47-55706G2 66-4710G2 47-55710G2 |
23.59 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Radium 226/228 Reduction Lead Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| SQC4 | 47-55702G2 47-55704G2 66-4706G2 47-55710G2 |
8.28 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| SQC4 Purificare | 47-55702PC 47-55704PC 66-4706PC 47-55710PC |
8.28 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. |
||||||
| A.O. Smith (China) Enviromental Products Co., Ltd. | |
| No.66 Lixing Road | |
| Lishui Economic Development Zone | |
| Nanjing, Jiangsu, Jiangsu 211200 | |
| China | |
| 86 25 5623 1999 |
Facility : # 1 China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] |
||||||
| CN-RO-75 | CN-RO-75-M | 15.68 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Lead Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Product also evaluated and determined to be capable of reducing hexavalent chromium to
meet the State of California’s maximum contaminant level of 0.010 mg/L.
|
||||||
| A.O. Smith Corporation | |
| 11270 West Park Place | |
| Milwaukee, WI 53224 | |
| United States | |
| 414-359-4000 | |
| Visit this company's website |
Facility : Zhongshan, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| AO-US-RO-4000 | AO-RO-MEM AO-4000-CARBON |
13.32 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Cadmium Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| A.O. Smith Corporation | |
| 11270 West Park Place | |
| Milwaukee, WI 53224 | |
| United States | |
| 800-527-1953 |
Facility : Haltom City, TX
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| AOW-3000 | AOW-3000-R | 13.32 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| A.O. Smith Su Teknolojileri A.S. | |
| Ikitelli O.S.B.Mh.Marmara D Blok Sk. | |
| No:2-3, Küçükçekmece-Ikitelli | |
| 34303 Istanbul | |
| Turkey | |
| 90 212 444 1646 | |
| Visit this company's website |
Facility : # 3 China
|
COMPONENTS: RO Membrane[1] [2] |
||||||
| RO-1812-50 | ||||||
| RO-1812-75 | ||||||
| RO-2012-100 | ||||||
| RO-2012-150 | ||||||
| RO-2812-200 | ||||||
| RO-3012-300 | ||||||
| RO-3012-400 | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, pH
value 3 ~ 8, flushing at least 48 hours.
[2] TF-XXYY-ZZ
XX - Membrane element diameter in inches
18 - 1.8"
20 - 2.0"
28 - 2.8"
30 - 3.0"
YY - Membrane element length in inches (12")
ZZ - Permeated flow in gallons per day (GPD) (50, 75, 100, 150, 200, 300 or 400)
|
||||||
| A.O. Smith Water Treatment (North American), Inc. | |
| 1900 Prospect Court | |
| Appleton, WI 54914 | |
| United States | |
| 800-777-1426 | |
| 920-739-9401 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| AORO-50 | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Alpspring Inc. | |
| No. 5 Gongye 4th Road | ![]() |
| Hukou Shiang | |
| Hsinchu County 303 | |
| Taiwan | |
| 886 3 5977675 |
Facility : Hsinchu County, Taiwan
|
COMPONENTS: Membranes[1] |
||||||
| NF90-1812-100 | ||||||
| NF90-1812-100-2 | ||||||
| NF90-1812-100-3 | ||||||
| NF90-1812-100-4 | ||||||
| NF90-1812-100-5 | ||||||
| NF90-1812-100-6 | ||||||
| NF90-1812-60 | ||||||
| NF90-2012-180 | ||||||
| TW40-1812-50 | ||||||
| TW40-1812-50-2 | ||||||
| TW40-1812-50-3 | ||||||
| TW40-1812-50-4 | ||||||
| TW40-1812-50-5 | ||||||
| TW40-1812-50-6 | ||||||
| TW40-2012-100 | ||||||
| TW40-2012-100-2 | ||||||
| TW40-2012-100-5 | ||||||
| XLE-1812-75 | ||||||
| XLE-1812-75-2 | ||||||
| XLE-1812-75-3 | ||||||
| XLE-1812-75-4 | ||||||
| XLE-1812-75-5 | ||||||
| XLE-1812-75-6 | ||||||
| XLE-2012-125 | ||||||
| XLE-2012-125-2 | ||||||
| XLE-2012-125-5 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Amtrol, Inc. | |
| 1400 Division Road | |
| West Warwick, RI 02893-1008 | |
| United States | |
| 401-884-6300 |
Facility : West Warwick, RI
|
COMPONENTS: Storage Tanks, Low Pressure |
||||||
| RO 2[1] [2] | ||||||
| RO 3[1] [2] | ||||||
| RO 4[1] [2] | ||||||
| RO 10[1] [2] | ||||||
| RO 14[1] [2] | ||||||
| RO 20[1] [2] | ||||||
| RO 34[1] [2] | ||||||
| RO 44[1] [2] | ||||||
| RO 86[1] [2] | ||||||
|
  [1] Conforms to the material and structural integrity requirements. [2] Low pressure storage tank |
||||||
| Applied Membranes Inc. | |
| 2450 Business Park Drive | |
| Vista, CA 92081 | |
| United States | |
| 800-321-9321 | |
| 760-727-3711 | |
| Visit this company's website |
Facility : Vista, CA
|
COMPONENTS: Membranes[1] [2] |
||||||
| 100 GPD TFC | ||||||
| 12 GPD TFC | ||||||
| 18 GPD TFC | ||||||
| 24 GPD TFC | ||||||
| 36 GPD TFC | ||||||
| 50 GPD TFC | ||||||
| 75 GPD TFC | ||||||
| M-T1512A12 | ||||||
| M-T1512A18 | ||||||
| M-T1810R24-RS | ||||||
| M-T1812A100 | ||||||
| M-T1812A100-NL | ||||||
| M-T1812A100ID | ||||||
| M-T1812A24 | ||||||
| M-T1812A24-NL | ||||||
| M-T1812A36 | ||||||
| M-T1812A50 | ||||||
| M-T1812A50-NL | ||||||
| M-T1812A75 | ||||||
| M-T1812AC24 | ||||||
| M-T1812AC36 | ||||||
| M-T1812AC36-NL | ||||||
| M-T1812AC50 | ||||||
| M-T1812Q24 | ||||||
| M-T1812Q30 | ||||||
| S1229RS[3] | ||||||
| S1340RS[3] | ||||||
| S1448RS[3] | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 24 hour flushing procedure.
[2] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
Selenium, and TDS.
[3] Conforms to material requirements when used in Microline or Rayne Corporation RO
systems Certified by NSF to NSF/ANSI 58.
|
||||||
| Aqua Systems | |
| 7785 East US Highway 36 | |
| Avon, IN 46123 | |
| United States | |
| 317-272-3000 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| AQPC-35[1] [2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| AQPC-435[2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Serial number of 180000 or higher.
[2] As of 05/28/2004.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Aquaporin A/S | |
| Nymollevej 78 | |
| Kongens Lyngby 2800 | |
| Denmark | |
| 45 82 30 30 82 | |
| Visit this company's website |
Facility : # 1 Denmark
|
COMPONENTS: Flat Sheet Membranes[1] [2] [Pb] |
||||||
| TWROFS | ||||||
|
  [1] Conforms to material requirements only.
[2] This membrane is certified as a maximum surface area of 72,850 square inches.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Aquaporin A/S | |
| Nymollevej 78 | |
| Kongens Lyngby 2800 | |
| Denmark | |
| 45 82 30 30 82 | |
| Visit this company's website |
Facility : # 2 Italy
|
COMPONENTS: Membrane Elements[1] [2] [Pb] |
||||||
| TWRO1812-150 | ||||||
| TWRO1812-175 | ||||||
| TWRO2012 | ||||||
| TWRO2812 | ||||||
| TWRO3012-600 | ||||||
|
  [1] Conforms to material requirements only.
[2] 24 hours of flushing with chlorine free feed water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Aquaporin A/S | |
| Nymollevej 78 | |
| 2800 Kongens Lyngby | |
| Denmark | |
| 45 82 30 30 82 | |
| Visit this company's website |
Facility : # 3 Korea
|
COMPONENTS: Membrane Elements[1] [2] [Pb] |
||||||
| TWRO1806-90 | ||||||
| TWRO1808-110 | ||||||
| TWRO1811-150 | ||||||
| TWRO1812-150 | ||||||
| TWRO1812-175 | ||||||
| TWRO3008-375 | ||||||
| TWRO3010-475 | ||||||
| TWRO3012-600 | ||||||
|
  [1] Conforms to material requirements only.
[2] 24 hours of flushing with chlorine free feed water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Aquasana Inc. | |
| 6310 Midway Road | |
| Haltom City, TX 76117 | |
| United States | |
| 817-536-5250 |
Facility : # 2 China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Austin Springs AS-RO-75[1] | Austin Springs AS-RO-75-M |
15.68 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Lead Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Product also evaluated and determined to be capable of reducing hexavalent chromium to
meet the State of California’s maximum contaminant level of 0.010 mg/L.
|
||||||
| Aquasana, Inc. | |
| 6310 Midway Road | |
| Haltom City, TX 76117 | |
| United States | |
| 817-536-5250 | |
| Visit this company's website |
Facility : Zhongshan, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| OptimH2O™ AQ-RO-3 | AQ-RO3-RO AQ-RO3-R |
13.32 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Aquasky Enterprises Co., Ltd. | |
| No. 36, Lane 212, Section 1 Hemu Road | |
| Shenggang District | |
| Taichung City 429 | |
| Taiwan | |
| 886 4 256 26368 | |
| Visit this company's website |
Facility : Taichung City, Taiwan
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| ROT-2 | ||||||
| ROT-3 | ||||||
| ROT-4 | ||||||
| ROT-6 | ||||||
| ROT-14 | ||||||
| ROT-20 | ||||||
|
  [1] Conforms to the material and structural integrity requirements only. |
||||||
| Aquasure Corporation | |
| 818 North Mountain Avenue | |
| Suite 203C | |
| Upland, CA 91786 | |
| United States | |
| 800-661-0680 | |
| Visit this company's website |
Facility : 1C
|
COMPONENTS: RO Membrane[1] |
||||||
| AF-MEMXXX[2] | ||||||
| AF-TFCXX-YYZZZ[3] | ||||||
|
  [1] Certified for material and structural integrity requirements only.
[2] AF-MEMXXX:
AF-MEM - Fixed Code
XXX - 36-600gpd
[3] AF-TFCXX-YYZZZ:
AF-TFC - Fixed Code
XX - 36-600gpd
YY - 18-30 Membrane Diameter in inches
ZZ - 7-12 Membrane Length in inches
|
||||||
| Aquatrol c/o Hydronix Water Technology | |
| 1240 East Belmont Street | |
| Ontario, CA 91761 | |
| United States | |
| 909 527 6996 | |
| Visit this company's website |
Facility : 1E
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| RO-14 | ||||||
| RO-2.0 | ||||||
| RO-20 | ||||||
| RO-3.2 | ||||||
| RO-4.5 | ||||||
| RO-6.0 | ||||||
|
  [1] Conforms to the material and structural integrity requirements only. |
||||||
| Aquion, Inc. | |
| 101 South Gary Avenue | |
| Roselle, IL 60172 | |
| United States | |
| 847-437-9400 | |
| Visit this company's website |
Facility : Roselle, IL
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Rainsoft Ultrefiner II-FMV-BNFP[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
| Rainsoft Ultrefiner II-FMV-BNFV[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
| Rainsoft Ultrefiner II-FMV-CHFP[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
| Rainsoft Ultrefiner II-FMV-CHFV[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
| Rainsoft Ultrefiner II-SFMV-BNFP[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
| Rainsoft Ultrefiner II-SFMV-BNFV[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
| Rainsoft Ultrefiner II-SFMV-CHFP[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
| Rainsoft Ultrefiner II-SFMV-CHFV[1] [2] [3] [4] | 51637 | 24.22 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction VOC Reduction ** Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] S - Sediment filter
F - Prefilter
M - Membrane
V - VOC post filter
[2] Tested and Certified for VOC Reduction using the 51636 post filter for a 225 gallon
capacity.
[3] Base models are Ultrefiner II-FMV and Ultrefiner II-SFMV. Suffixes ( BNFP, BNFV, CHFP
and CHFV) represent faucet type.
[4] As of 1/15/2018.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
| Atlantic Filter Corporation | |
| 3112 45th Street | |
| West Palm Beach, FL 33407 | |
| United States | |
| 561-683-0101 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| HR-35-TFC-4W[1] [2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] As of 05/28/2004.
[2] Serial number of 180000 or higher.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| AXEON Water Technologies | |
| 40980 County Center Drive | |
| Suite 100 | |
| Temecula, CA 92591 | |
| United States | |
| 800-320-4074 | |
| Visit this company's website |
Facility : # 3 China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Component: RO membrane[1] [2] |
||||||
| TF-1512-25 | ||||||
| TF-1812-50 | ||||||
| TF-1812-75 | ||||||
| TF-2012-100 | ||||||
| TF-2012-150 | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, pH
value 3 ~ 8, flushing at least 48 hours.
[2] TE-XXYY-ZZ
XX - Membrane element diameter in inches
15 - 1.5"
18 - 1.8"
20 - 2.0"
YY - Membrane element length in inches (12")
ZZ - Permeated flow in gallons per day (GPD) (25, 50,75, 100, 150)
|
||||||
| Canature Health Technology Group Co., Ltd. | |
| No. 508 & 518, Chuanda Road | |
| Pudong New Area | |
| Shanghai, 201200 | |
| China | |
| 86 21 5859 9999 | |
| Visit this company's website |
Facility : Shanghai, China
|
COMPONENTS: Membranes[1] [Pb] |
||||||
| 1812-100-NPD | ||||||
| 1812-100-NPI | ||||||
| 1812-30-NPD | ||||||
| 1812-30-NPI | ||||||
| 1812-50-NPD | ||||||
| 1812-50-NPI | ||||||
| 1812-75-NPD | ||||||
| 1812-75-NPI | ||||||
| 2012-100-NPD | ||||||
| 2012-100-NPI | ||||||
| 2012-150-NPD | ||||||
| 2012-150-NPI | ||||||
| 2012-180-NPD | ||||||
| 2012-180-NPI | ||||||
| 2812-200-NPD | ||||||
| 2812-200-NPI | ||||||
| 2812-300-NPD | ||||||
| 2812-300-NPI | ||||||
| 2813-300-NPD | ||||||
| 2813-300-NPI | ||||||
| 3012-300-NPD | ||||||
| 3012-300-NPI | ||||||
| 3012-400-NPD | ||||||
| 3012-400-NPI | ||||||
| 3012-500-NPD | ||||||
| 3012-500-NPI | ||||||
| 3012-600-NPD | ||||||
| 3012-600-NPI | ||||||
| 3013-400-NPD | ||||||
| 3013-400-NPI | ||||||
| 3013-600-NPD | ||||||
| 3013-600-NPI | ||||||
| AQ-1812-100 | ||||||
| AQ-1812-30 | ||||||
| AQ-1812-50 | ||||||
| AQ-1812-75 | ||||||
| AQ-2012-100 | ||||||
| AQ-2012-150 | ||||||
| AQ-2012-180 | ||||||
| AQ-2812-200 | ||||||
| AQ-2812-300 | ||||||
| AQ-2813-300 | ||||||
| AQ-3012-300 | ||||||
| AQ-3012-400 | ||||||
| AQ-3012-500 | ||||||
| AQ-3012-600 | ||||||
| AQ-3013-400 | ||||||
| AQ-3013-600 | ||||||
| CN-1812-100 | ||||||
| CN-1812-30 | ||||||
| CN-1812-50 | ||||||
| CN-1812-75 | ||||||
| CN-2012-100 | ||||||
| CN-2012-150 | ||||||
| CN-2012-180 | ||||||
| CN-2812-200 | ||||||
| CN-2812-300 | ||||||
| CN-2813-300 | ||||||
| CN-3012-300 | ||||||
| CN-3012-400 | ||||||
| CN-3012-500 | ||||||
| CN-3012-600 | ||||||
| CN-3013-400 | ||||||
| CN-3013-600 | ||||||
| Robot-1812-100 | ||||||
| Robot-1812-30 | ||||||
| Robot-1812-50 | ||||||
| Robot-1812-75 | ||||||
| Robot-2012-100 | ||||||
| Robot-2012-150 | ||||||
| Robot-2012-180 | ||||||
| Robot-2812-200 | ||||||
| Robot-2812-300 | ||||||
| Robot-2813-300 | ||||||
| Robot-3012-300 | ||||||
| Robot-3012-400 | ||||||
| Robot-3012-500 | ||||||
| Robot-3012-600 | ||||||
| Robot-3013-400 | ||||||
| Robot-3013-600 | ||||||
|
  [1] Conforms to material requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Plumbed-In to Separate Tap |
||||||
| BNT-RO122 | 1812-75-NPI 1812-75-NPD CN-1812-75 |
109.04 | TDS Reduction | |||
| BNT-RO125 | 1812-75-NPI 1812-75-NPD CN-1812-75 |
109.04 | TDS Reduction | |||
| BNT-RO131 | 1812-75-NPI 1812-75-NPD CN-1812-75 |
18.12 | TDS Reduction | |||
| BNT-RO133 | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| BNT-RO221 | 1812-75-NPI 1812-75-NPD CN-1812-75 |
109.04 | TDS Reduction | |||
| BNT-RO301 | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| BNT-RO309 | 1812-50-NPI 1812-50-NPD CN-1812-50 |
14.29 | TDS Reduction | |||
| CN-RO-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| CN-RO75 | 1812-75-NPI 1812-75-NPD CN-1812-75 |
109.04 | TDS Reduction | |||
| RO-B02-75G | 1812-75-NPI 1812-75-NPD CN-1812-75 |
109.04 | TDS Reduction | |||
| RO-B03-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
14.29 | TDS Reduction | |||
| RO-B03-75G | 1812-75-NPI 1812-75-NPD CN-1812-75 |
18.12 | TDS Reduction | |||
| RO-B04-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| RO-B04-75G | 1812-75-NPI 1812-75-NPD CN-1812-75 |
109.04 | TDS Reduction | |||
| RO-B05-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| RO-B05-75G | 1812-75-NPI 1812-75-NPD CN-1812-75 |
109.04 | TDS Reduction | |||
| RO-R05-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
14.29 | TDS Reduction | |||
| RO-R06-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| RO-R07-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| RO-R08-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| RO-R09-50G | 1812-50-NPI 1812-50-NPD CN-1812-50 |
89.01 | TDS Reduction | |||
| Chao Lung Plastics Co., Ltd. | |
| No. 134 Lane 107 Lien Tsun Road | |
| Feng Yuan City, Taichung Hsien | |
| Taiwan | |
| 886 4 2539 5006 | |
| Visit this company's website |
Facility : # 2 Taichung Hsien, Taiwan
|
COMPONENTS: Filter Housings[1] |
||||||
| R.O Housing | ||||||
|
  [1] Conforms to material and structural requirements. |
||||||
| Clover Co., Ltd. | |
| 61, Simin-Daero 98beon-gil | |
| Dongan-gu, Anyang-si, Gyeonggi-do | |
| Korea, Republic of | |
| 82 31 425 8811 | |
| Visit this company's website |
Facility : # 1 Republic of Korea
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| AQVR5 | AQV-CB AQV-SED AQV-RO50 AQV-CM |
23.39 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Radium 226/228 Reduction Lead Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| CLVR5 | CLV-CB CLV-SED CLV-RO50 CLV-CM |
23.39 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Coway Co., Ltd. | |
| 136-23, Yugumagoksa-ro | |
| Yugu-eup, Gongju-si | |
| Chungcheongnam-do | |
| Korea, Republic of | |
| 82 2 870 5110 | |
| Visit this company's website |
Facility : Shandong, China
|
COMPONENTS: Membrane Elements, Encapsulated |
||||||
| CRMFN11-30 | ||||||
| CRMFN11-50 | ||||||
| CRMFN11S-30 | ||||||
| CRMFN14-50 | ||||||
| CRMFN14-75 | ||||||
| CRMFN8S-20 | ||||||
Facility : Gongju-Si, Chungcheongnam-do, Republic of Korea
|
COMPONENTS: Membrane Elements, Encapsulated |
||||||
| CCRMFN12-D-600 | ||||||
| CRMFN11-30 | ||||||
| CRMFN11-50 | ||||||
| CRMFN11S-30 | ||||||
| CRMFN14-50 | ||||||
| CRMFN14-75 | ||||||
| CRMFN8S-20 | ||||||
| Easywell Water Systems, Inc. | ![]() |
| 222-2 Chia-Tung Rd., Sec. 2 | |
| Changhua 500 | |
| Taiwan | |
| 886 4 736 3333 | |
| Visit this company's website |
Facility : Changhua, Taiwan
|
COMPONENTS: Faucets[1] |
||||||
| ZWDF-1002 | ||||||
| ZWDF-1002 (3") | ||||||
| ZWDF-1003 | ||||||
|
  [1] Certified for material and structural integrity requirements. |
||||||
| Easywell Water Systems, Inc. | ![]() |
| 222-2 Chia-Tung Rd., Sec. 2 | |
| Changhua 500 | |
| Taiwan | |
| 886 4 736 3333 | |
| Visit this company's website |
Facility : # 1 China
|
COMPONENTS: Membranes[1] |
||||||
| ALYA-MBS10100 | ||||||
| ALYA-MBS10150 | ||||||
| ALYA-MBS1024 | ||||||
| ALYA-MBS1036 | ||||||
| ALYA-MBS1050 | ||||||
| ALYA-MBS1075 | ||||||
| MBS10100 | ||||||
| MBS10150 | ||||||
| MBS1024 | ||||||
| MBS1036 | ||||||
| MBS1050 | ||||||
| MBS1075 | ||||||
|
  [1] Certified to Standard 58, material requirements only. Membranes require a 24-hour
flushing before use.
|
||||||
| Ecodyne Water Systems | |
| 1890 Woodlane Drive | |
| Woodbury, MN 55125 | |
| United States | |
| 866-986-3223 | |
| 651-739-5330 |
Facility : Iuka, MS
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Brita Total360 BRDROS | BRDROF[1] BRDROM[1] |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| ECOP30[2] | ECOROM | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction Nitrate/Nitrite Reduction |
|||
| EP-RO25[2] | EP-ROM | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction Nitrate/Nitrite Reduction |
|||
| HCGROS5[2] | HCGROF5 HCGROM5 |
18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
| HDGROS4[2] | HDGROF4 HDGROM4 |
18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Fluoride Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
| TB-RO[2] | 1081-01-FB-Z1 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction Nitrate/Nitrite Reduction |
|||
| WHAPSRO[2] | WHEERF WHEERM |
18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
| WHAROS5[2] | WHEERF WHEERM |
18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
| WHER25[2] | WHEERF WHEERM |
18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Brita Total360
[2] As of May 4, 2018
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Membrane Elements[3] |
||||||
| WHERM[Pb] | ||||||
| WHERPM[Pb] | ||||||
|
  [3] Conforms to material requirements only. Membrane requires a 24 hour flushing and
conditioning procedure.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| EcoWater Systems | |
| 1890 Woodlane Drive | ![]() |
| Woodbury, MN 55125 | |
| United States | |
| 651-739-5330 |
Facility : Iuka, MS
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] [Pb] |
||||||
| ERO-175 | 7308297 | 14.53 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction Nitrate/Nitrite Reduction |
|||
| ERO-375 | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| ERO-375-BK | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| ERO-375-BN | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| ERO-375-CP | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| ERO-375-RB | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| ERO-375-WH | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| ERO-375E | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| ERO-375E-BK | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| ERO-375E-BN | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| ERO-375E-CP | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| ERO-375E-RB | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| ERO-375E-WH | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| ERO-385 | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385-BK | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385-BN | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385-CP | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385-RB | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385-WH | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385E | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385E-BK | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385E-BN | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385E-CP | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385E-RB | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| ERO-385E-WH | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| HERO-375-BK | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| HERO-375-BN | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| HERO-375-CP | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| HERO-375-PLUS[Pb] | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| HERO-375-RB | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| HERO-375-WH | 7278905 | 17.4 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| HERO-385-BK | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| HERO-385-BN | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| HERO-385-CP | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| HERO-385-RB | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| HERO-385-WH | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| HERO-385PLUS | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Nitrate/Nitrite Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Conforms to material requirements only. Membrane requires a 24 hour flushing and
conditioning procedure.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| EcoWater Systems LLC | ![]() |
| P.O. Box 64420 | |
| St. Paul, MN 55164 | |
| United States | |
| 800-869-2837 | |
| Visit this company's website |
Facility : Iuka, MS
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| ERO-175[Pb] | 7308297 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Fluoride Reduction |
|||
| ERO-385[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385-BK[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385-BN[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385-CP[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385-RB[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385-WH[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385E[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385E-BK[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385E-BN[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385E-CP[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385E-RB[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| ERO-385E-WH[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| HERO-385-BK[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| HERO-385-BN[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| HERO-385-CP[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| HERO-385-RB[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| HERO-385-WH[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| HERO-385PLUS[Pb] | 7380639 | 15.75 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Electrolux | |
| St. Goransgatan 143 | |
| SE-105 45 Stockholm | |
| Sweden | |
| 46 87 387 512 |
Facility : Iuka, MS
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] [Pb] |
||||||
| ELXROEU | ELXROEU | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Selenium Reduction TDS Reduction Turbidity Reduction Radium 226/228 Reduction Nitrate/Nitrite Reduction |
|||
| ELXROTU | ELXRM14 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Conforms to material requirements only. Membrane requires a 24 hour flushing and
conditioning procedure.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Elken Sdn. Bhd. | |
| 20, Bangunan Elken, Jalan 1/137C | |
| Batu 5, Jalan Kelang Lama, Kuala Lumpur | |
| Kuala Lumpur 58000 | |
| Malaysia | |
| 60 3 7985 8888 |
Facility : # 1 Korea
|
COMPONENTS: Membrane Elements[1] [2] |
||||||
| RE1812-50 | ||||||
| RE1812-50(N) | ||||||
|
  [1] Conforms to material requirements only.
[2] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
Selenium and TDS. The test data results may be transferred to other manufacturer's
systems, if the systems meet the requirements contained in the document entitled
"Transfer of Performance Claims for Toray Chemical Korea Reverse Osmosis Elements”. This
document is available from Toray Chemical Korea Inc. (Formerly Woongjin Chemical Co.,
Ltd.)
|
||||||
| Emonyx, LLC | |
| 2230 Loch Way | |
| El Dorado Hills, CA 95762 | |
| United States | |
| 916-548-0033 |
Facility : Ningbo, Zhejiang, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| BLUONICS 100G | ||||||
| BLUONICS 200G | ||||||
| BLUONICS 300G | ||||||
| BLUONICS 50G | ||||||
| BLUONICS 75G | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 48 hour flushing procedure. |
||||||
| EUROTROL S.P.A. | |
| Via E. Fermi,23-20019 | |
| 20019 Settimo Milano | |
| Italy | |
| 39 02 33545834 | |
| Visit this company's website |
Facility : # 3 China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Component: RO membrane[1] [2] |
||||||
| MMRO 1812-50 | ||||||
| MMRO 1812-75 | ||||||
| MMRO 2012-100 | ||||||
| MMRO 2012-150 | ||||||
| MMRO 2812-200 | ||||||
| MMRO 3012-300 | ||||||
| MMRO 3012-400 | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, pH
value 3 ~ 8, flushing at least 48 hours.
[2] TF-XXYY-ZZ
XX - Membrane element diameter in inches
18 - 1.8"
20 - 2.0"
28 - 2.8"
30 - 3.0"
YY - Membrane element length in inches (12")
ZZ - Permeated flow in gallons per day (GPD) (50, 75, 100, 150, 200, 300 or 400)
|
||||||
| Everpure LLC | ![]() |
| 1040 Muirfield Drive | |
| Hanover Park, IL 60133 | |
| United States | |
| 800-323-7873 | |
| Visit this company's website |
Facility : Hanover Park, IL
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Conserv 75E[Pb] | 4CC GRO-75EN 4FC5 4CB5 |
50.51 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| Conserv 75S[Pb] | 4CC GRO-75EN 4FC5 |
50.51 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| Conserv HE-3[Pb] | SEN MR-600F SEN+ |
443.68 | TDS Reduction | |||
| Conserv LT-S[Pb] | 4CC GRO-75EN 4FC5 |
75 | TDS Reduction | |||
| LVRO-75HE | GRO-75EN 2FC5-S 2CB5 |
14.66 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| LVRO-75HE+F | GRO-75EN 2FC5-S 2CB5 |
14.66 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| MRS-600HE[Pb] | MR-600 | 482.48 | TDS Reduction | |||
| MRS-600HE[Pb] | MR-600F | 760.09 | TDS Reduction | |||
| MRS-600HE[Pb] | MR-600-1 | 760.09 | TDS Reduction | |||
| MRS-600HE-II (General Market)[1] [Pb] | MR-600 | 763.35 | TDS Reduction | |||
| MRS-600HE-II (General Market)[1] [Pb] | MR-600-1 | 507.76 | TDS Reduction | |||
| MRS-600HE-II (General Market)[1] [Pb] | MR-600F | 507.76 | TDS Reduction | |||
| MRS-600HE-II (Starbucks)[1] [Pb] | MR-600F | 507.76 | TDS Reduction | |||
| MRS-600HE-II (Starbucks)[1] [Pb] | MR-600-1 | 507.76 | TDS Reduction | |||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Certified for use with HE-II Upgrade Pump Kit Retro.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Express Water Co., Ltd. / TANKRO | |
| 12730 Raymer Street | |
| Unit #1 | |
| North Hollywood, CA 91605 | |
| United States | |
| 800-992-8876 | |
| Visit this company's website |
Facility : Zhejiang, China
|
COMPONENTS: Storage Tanks, Low Pressure[1] [2] |
||||||
| RO132 - TNK | ||||||
|
  [1] Conforms to material and structural integrity requirements only. [2] The unit volume of RO132 - TNK is 4.4 gallon. |
||||||
| Express Water Inc. | |
| 12730 Raymer | |
| North Hollywood, CA 91605 | |
| United States | |
| 800-992-8876 | |
| Visit this company's website |
Facility : # 1 Taiwan
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap[Pb] |
||||||
| RO10DX | FLTMEME100 | 21.89 | TDS Reduction | |||
| RO5DX | FLTMEME50 | 12.22 | TDS Reduction | |||
|
  [Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| FilmTec Corporation | |
| 5400 Dewey Hill Road | |
| Edina, MN 55439 | |
| United States | |
| 952-897-4269 | |
| Visit this company's website |
Facility : # 2 USA
|
COMPONENTS: Flat Sheet Membranes[1] |
||||||
| BW30 (168881) | ||||||
| BW30 (366479) | ||||||
| BW30 (99024964) | ||||||
| BW30LE (168882) | ||||||
| BW30LE (366481) | ||||||
| BW30LE (99025012) | ||||||
| MEMBRANE TW60 35.0 (99052932) | ||||||
| MEMBRANE XLE 37.0 C HZ (12013860) | ||||||
| MEMBRANE XLP (11098098) | ||||||
| MEMBRANE XLP (99025011) | ||||||
| XLE (216818) | ||||||
| XLE (365877) | ||||||
| XLE (99025014) | ||||||
| eXLE Membrane (99109939) | ||||||
| eXLE Membrane (99110343) | ||||||
|
  [1] Conforms to material requirements only. |
||||||
|
COMPONENTS: Membrane Elements[2] |
||||||
| AQUALAST™ 1812-HR (11112537) | ||||||
| BW60-1812-75 (11018585)[3] | ||||||
| BW60-1812-75 (GMID 99017671)[3] [Pb] | ||||||
| BW60-1812-75(99017840)[3] | ||||||
| TW30-1812-100HR (GMID 11013537)[3] | ||||||
| TW30-1812-24 (93430)[4] [Pb] | ||||||
| TW30-1812-50HR (99101033)[3] | ||||||
| TW30-1812E-50HR (99101260)[3] | ||||||
|
  [2] Conforms to material requirements only. Membrane requires a 24 hour flushing and
conditioning prodecure.
[3] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228, Selenium,
Turbidity, and TDS. The test data results may be transferred to other manufacturer's
systems, if the systems meet the requirements contained on the document entitled, "Data
Transfer Procedure for Devices using Filmtec Reverse Osmosis", dated 12/19/2011. This
document is available from FilmTec.
[4] Associated with a data transfer protocol. See manufacturer for more information.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Facility : # 3 USA
|
COMPONENTS: Membrane Elements[1] [Pb] |
||||||
| AquaLast 1812 (99021845) | ||||||
| TW30-3012-500 (11102789) | ||||||
| TW30-3812-800 (99068403) | ||||||
| TW30-3812E-800 (99101034) | ||||||
|
  [1] Conforms to material requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Facility : Shanghai, China
|
COMPONENTS: Membrane Elements |
||||||
| TAPTEC™ TT-1812-50 | ||||||
| TAPTEC™ TT-3012-400 | ||||||
| Flexcon Industries | |
| 300 Pond Street | |
| P.O. Box 782 | |
| Randolph, MA 02368 | |
| United States | |
| 800-527-0030 |
Facility : Taichung, Taiwan
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| FRO1070 | ||||||
| FRO120 | ||||||
| FRO122 | ||||||
| FRO122P | ||||||
| FRO132 | ||||||
| FRO152 | ||||||
| FRO200 | ||||||
|
  [1] Conforms to the material and structural integrity requirements. |
||||||
| Foshan City Shunde District Infentai Environment Protection Technology Co., Ltd. | |
| No. 12-1, Fulv Industrial Dev. Area | |
| Leliu Town, Shunde District | |
| Foshan 528300 | |
| China | |
| 86 757 2366 9926 | |
| Visit this company's website |
Facility : Foshan, China
|
COMPONENTS: Membranes[1] [Pb] |
||||||
| YFT-1812-100G | ||||||
| YFT-1812-50G | ||||||
| YFT-1812-75G | ||||||
| YFT-2012-200G | ||||||
| YFT-3013-400G | ||||||
| YFT-3013-600G | ||||||
| YFT-3013-800G | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 24 hour flushing procedure.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Foshan Midea Chungho Water Purification Equipment Co., Ltd. | |
| No. 68 Guangle Road, Beijiao, Shunde | |
| Foshan, Guangdong | |
| 528311 | |
| China | |
| 86 134 5058 6360 | |
| Visit this company's website |
Facility : Foshan, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| MIDEA MF-2713-BT1 RO FILTER | ||||||
| MIDEA MF-3710-F1D2 RO FILTER | ||||||
| MIDEA MF-3711-E2D2 RO FILTER | ||||||
| MIDEA MF-3712-E2D2 RO FILTER | ||||||
| MIDEA MF-4111-M4D4 RO FILTER | ||||||
| MIDEA MF-4312-E8D5 RO FILTER | ||||||
|
  [1] Conforms to material and structural integrity requirements only. |
||||||
| Freecom Water Purified Co., Ltd. | |
| No. 12, Alley 9, Lane 360, Zhongshan | |
| Road, Shengang District, Taichung | |
| 42947 | |
| Taiwan | |
| 886 42 563 2899 | |
| Visit this company's website |
Facility : # 1 Taiwan
|
COMPONENTS: RO Membrane[1] |
||||||
| FC 1810-100 | ||||||
| FC 1810-50 | ||||||
| FC 1810-70 | ||||||
| FC 1812-50 | ||||||
| FC 1812-60 | ||||||
| FC 2012-100 | ||||||
| FC 2012-180 | ||||||
| FC 2012-250 | ||||||
| FC 2012-60 | ||||||
| FC 2012-80 | ||||||
| FC 3012-300 | ||||||
| FC 3012-400 | ||||||
| FC 3012-500 | ||||||
| FC 3012-600 | ||||||
| FC-2012-120 | ||||||
| FC-2012-150 | ||||||
|
  [1] Certified for material and structural integrity requirements only. |
||||||
| GE Appliances, a Haier Company | |
| Appliance Park AP5 | |
| Louisville, KY 40225 | |
| United States | |
| 800-952-5039 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| GNRQ18NBN | FQ18MN FQ18PN |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Asbestos Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| GXRQ18NBN | FQ18MN FQ18PN |
14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Asbestos Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| GHP Group Inc. | |
| 6440 West Howard Street | |
| Niles, IL 60714 | |
| United States | |
| 877-227-4768 | |
| 847-324-5900 | |
| Visit this company's website |
Facility : ShenZhen, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| VRO-3Q | VRFQ-RO | 20.3 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| VRO-3U | VRFU-RO | 23.3 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| VRO-4Q | VRFQ-RO | 20.3 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| VRO-4U | VRFU-RO | 23.3 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| VRO-5Q | VRFQ-RO | 20.3 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. |
||||||
| Global Aqua Technology | |
| 13963 Ramona Avenue | ![]() |
| Suite E | |
| Chino, CA 91710 | |
| United States |
Facility : # 1A
|
COMPONENTS: Membrane Elements[1] |
||||||
| MTW-1810-36 | ||||||
| MTW-1810-50 | ||||||
| MTW-1812-100 | ||||||
| MTW-1812-36 | ||||||
| MTW-1812-50 | ||||||
| MTW-1812-75 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Grand Forest Electrical Co., Ltd. | |
| Building 4, Ke Chuang Center | |
| Henglin Town, Wujin District | |
| Changzhou, Jiangsu 213101 | |
| China | |
| 86 519 8871 0811 | |
| Visit this company's website |
Facility : Jiangsu, China
|
COMPONENTS: RO Booster Pump[1] |
||||||
| GFP Booster Pump | ||||||
| GFP-50 | ||||||
| GFP-75 | ||||||
| GFP-100 | ||||||
| GFP-200 | ||||||
| GFP-300 | ||||||
| GFP-400 | ||||||
|
  [1] Conforms to material requirements and structual integrity requirements only. |
||||||
| Hangzhou E-MEM Environmental Technology Co., Ltd. | |
| No. 26 Longquan Road, Cangqian Street | |
| Yuhang District | |
| Hangzhou City, Zhejiang Province 311121 | |
| China | |
| 86 571 88620831 | |
| Visit this company's website |
Facility : Zhejiang Province, China
|
COMPONENTS: Membranes[1] |
||||||
| EM-RO-1812-50 | ||||||
| EM-RO-1812-75 | ||||||
| EM-RO-2012-100 | ||||||
| EM-RO-2012-75 | ||||||
| EM-RO-2012-75B | ||||||
| EM-RO-2812-150 | ||||||
| EM-RO-2812-200 | ||||||
| EM-RO-3012-300 | ||||||
| EM-RO-3012-400 | ||||||
| EM-RO-3012-ULP | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Hangzhou Haina Environmental Protection Tech Co., Ltd. | |
| Building 1#, Fengdu Village | |
| Pingyao Town | |
| Hangzhou, Zhejiang 311115 | |
| China | |
| 86 571 8853 2213 | |
| Visit this company's website |
Facility : Zhejiang, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| 1812-50 | ||||||
| GT 3012-400 | ||||||
| GT 3012-500 | ||||||
| GT 3012-600 | ||||||
| GT 3012-700 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Hellenbrand Inc. | |
| 404 Maravian Valley Road | |
| P.O. Box 187 | |
| Waunakee, WI 53597-0187 | |
| United States | |
| 608-849-3050 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Millennium MRO-35[1] [2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| Millennium MRO-35GF[2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Serial number of 180000 or higher.
[2] As of 05/28/2004.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| HongKong Ecoaqua Co., Limited / Qingdao Ecopure Filter Co., Ltd. | ![]() |
| No. 13, Yishengbai Road | |
| Environmental Protection Industry Zone | |
| Jimo, Qingdao 266201 | |
| China | |
| 86 532 8755 4398 | |
| Visit this company's website |
Facility : Fujian, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap[1] |
||||||
| WD-G3-B | WD-G3-N1CF WD-G3-N2RO WD-G3-N3CB |
400 | TDS Reduction | |||
| WD-G3-G | WD-G3-N1CF WD-G3-N2RO WD-G3-N3CB |
400 | TDS Reduction | |||
| WD-G3-W | WD-G3-N1CF WD-G3-N2RO WD-G3-N3CB |
400 | TDS Reduction | |||
|
  [1] B- Black
G- Gray
W- White
|
||||||
| Hunan Ovay Technology Co., Ltd. | |
| Huoju Road IV, Liyu Zone | |
| Tianyuan District | |
| Zhuzhou, Hunan Province 412000 | |
| China | |
| 86 731 2286 6639 | |
| 86 731 2286 6639 | |
| Visit this company's website |
Facility : Zhuzhou, China
|
COMPONENTS: Membranes[1] |
||||||
| OV-ULP 1812-50 | ||||||
| OV-ULP 1812-75 | ||||||
| OV-ULP 2012-100 | ||||||
| OV-ULP 2812-200 | ||||||
| OV-ULP 3012-300 | ||||||
| OV-ULP 3013-400 | ||||||
| OV-ULP 3020-420 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Hydron Membrane Technology | |
| 8630 Rochester Avenue | |
| Rancho Cucamonga, CA 91730 | |
| United States | |
| 909-527-6996 | |
| Visit this company's website |
Facility : 3A
|
COMPONENTS: Membrane Elements[1] [2] |
||||||
| TW-1812-50 | ||||||
| TW-1812-75 | ||||||
| TW-2012-100 | ||||||
| TW-2012-150 | ||||||
| TW-3012-240 | ||||||
|
  [1] Certified to Standard 58, material requirements only. Membranes require a 24-hour
flushing before use.
[2] TW-XXYY-ZZ
TW - Type of membrane sheet
XX - Membrane element diameter in inches
18 - 1.8"
20 - 2.0"
30 - 3.0"
YY - Membrane element length in inches (12'')
ZZ - Permeated flow in gallons per day (GPD) (50, 75, 100, 150)
|
||||||
| Hydron Membrane Technology | |
| 8630 Rochester Avenue | |
| Rancho Cucamonga, CA 91730 | |
| United States | |
| 909-527-6996 | |
| Visit this company's website |
Facility : 1C
|
COMPONENTS: RO Membrane[1] |
||||||
| HDG-PWMWMKC60 | ||||||
| HDG-TFM36 | ||||||
| HDG-TFM50 | ||||||
| HDG-TQ56-100FC | ||||||
| HDG-TQ56-36FC | ||||||
| HDG-TQ56-50FC | ||||||
| HDG-TQ56-75FC | ||||||
| HDG-TWZZZ[4] | ||||||
| HDG-WP105331-50 | ||||||
| HDG-WQCM13-100 | ||||||
| HDG-WQCM13-50 | ||||||
| HDGT-TWZZZ[3] | ||||||
| TW-XXYY-ZZZ[2] | ||||||
|
  [1] Certified for material and structural integrity requirements only.
[2] TW-XXYY-ZZZ
TW - Fixed Code
XX - Diameter in inches 18-30
YY - Length in inches 7-12
ZZZ - Gallons Per Day 36-600
[3] HDGT-TWZZZ
HDGT-TW - Fixed Code
ZZZ - Gallons Per Day 36-600
[4] HDG-TWZZZ
HDG-TW - Fixed Code
ZZZ - Gallons Per Day 36-600
|
||||||
| Hydronix Water Technology | |
| 1240 East Belmont Street | |
| Ontario, CA 91761 | |
| United States | |
| 909-527-6996 |
Facility : 1A
|
COMPONENTS: Membrane Pressure Vessels[1] |
||||||
| MH03-1812WH | ||||||
|
  [1] Conforms to material and structural integrity requirements only. |
||||||
| Ihlas Ev Aletleri Imalat, Sanayi Ve Ticaret A.S | ![]() |
| Mermerciler Sanayi Sitesi | |
| 7'Nci Cadde No:12 34524 | |
| Istanbul | |
| Turkey | |
| 90 212 875 35 62 | |
| Visit this company's website |
Facility : Istanbul, Turkey
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| 101 MC | 349004Z | 67.04 | TDS Reduction | |||
| Aura Cebilon 101 ME | 350003Z 350002Z 350004Z 340005Z06 |
75.15 | TDS Reduction | |||
| Aura Cebilon 101 MF | 349004Z 349004Z02 340071Z 340069Z 340070Z 340005Z06 |
34.03 | TDS Reduction | |||
| Aura Cebilon Platinum 101 PT | 340005Z06 340069Z 340070Z 340071Z 349004Z 349004Z02 |
34.03 | TDS Reduction | |||
| rexwat | 340005Z06 340069Z 340070Z 340071Z 349004Z 349004Z02 |
34.03 | TDS Reduction | |||
| Infinite Water Solutions Pvt. Ltd. | |
| B1/B2, 701, Marathon Innova | |
| Marathon NextGen, Off Ganpatrao Kadam | |
| Marg, Lower Parel, Mumbai 400013 | |
| India | |
| 91 135 3056195 |
Facility : Dehradun, India
|
COMPONENTS: Membrane Elements[1] |
||||||
| 1812 - AG 50 | ||||||
| 1812 GRO 75 | ||||||
| 1812 NF 75 | ||||||
| 1812-AG 75 | ||||||
| GRO NANO 75 | ||||||
| NANO AG 50 | ||||||
| NANO AG 75 | ||||||
|
  [1] Confirms to material requirements only. |
||||||
| INNOTRIO Co., Ltd. | |
| No. 32, Wuquan 3rd Road | |
| Wugu District, New Taipei City 248 | |
| Taiwan | |
| 886 2 2291 9000 | |
| Visit this company's website |
Facility : # 1 Taiwan
|
COMPONENTS: Membrane Elements |
||||||
| UF-22 | ||||||
| UF-504 | ||||||
| UF-54 | ||||||
| UF-54-1 | ||||||
| Jiangyin Lichuang Jinyi Chemical Co., Ltd. | |
| 1053, No. 3808-5 Zhencheng Road | |
| Huangtu Town | |
| Jiangyin, Jiangsu 214445 | |
| China | |
| 86 135 8505 0999CELL |
Facility : Jiangsu, China
|
COMPONENTS: Polyethylene Terephthalate (PET)[1] [2] |
||||||
| Tricot Permeant Carrier LC-20 | ||||||
| Tricot Permeant Carrier LC-25 | ||||||
| Tricot Permeant Carrier LC-30 | ||||||
| Tricot Permeant Carrier LC-35 | ||||||
|
  [1] Conforms to material requirements only. [2] This product is Certified for a maximum use level of 1650 cm²/L. |
||||||
| KeenSen Technology Co., Ltd. | |
| No.6, Lutian RD | |
| Lu Valley, Changsha, Hunan | |
| 410205 | |
| China | |
| 86 731 8997 2869 | |
| Visit this company's website |
Facility : Hunan, China
|
COMPONENTS: Membrane Elements[1] [2] |
||||||
| RO-1812-50 | ||||||
| RO-1812-75 | ||||||
| RO-2012-100 | ||||||
| RO-2812-200 | ||||||
| RO-3012-300 | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, pH
value 3 ~ 8, flushing at least 48 hours.
[2] RO-XXYY-ZZ
XX - Membrane element diameter in inches
15 - 1.5"
18 - 1.8"
20 - 2.0"
28 - 2.8"
30 - 3.0"
YY - Membrane element length in inches (12")
ZZ - Permeated flow in gallons per day (GPD)(50, 75, 100, 150, 300 or 400)
|
||||||
|
COMPONENTS: RO Membrane[1] [2] |
||||||
| RO-1512-50 | ||||||
| RO-1812-50 | ||||||
| RO-1812-75 | ||||||
| RO-1812-LE | ||||||
| RO-2012-100 | ||||||
| RO-2012-150 | ||||||
| RO-2012-HR | ||||||
| RO-2812-200 | ||||||
| RO-3012-300 | ||||||
| RO-3012-400 | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, pH
value 3 ~ 8, flushing at least 48 hours.
[2] RO-XXYY-ZZ
XX - Membrane element diameter in inches
15 - 1.5"
18 - 1.8"
20 - 2.0"
28 - 2.8"
30 - 3.0"
YY - Membrane element length in inches (12")
ZZ - Permeated flow in gallons per day (GPD)(50, 75, 100, 150, 300 or 400)
|
||||||
| Kemflo / Filbur | |
| No. 3 Huan East Street, Da-Zhou | |
| Pingtung 900 | |
| Taiwan | |
| 886 8 7524736 |
Facility : # 1 China
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| PRO4000 | ||||||
|
  [1] Conforms to the materials and structural integrity requirements only. |
||||||
Facility : # 2 Pingtung, Taiwan
|
COMPONENTS: Membrane Elements[1] |
||||||
| KFM-1812-100 | ||||||
| KFM-1812-150 | ||||||
| KFM-1812-50 | ||||||
| KFM-1812-75 | ||||||
|
  [1] Conforms to the material requirements only. |
||||||
|
COMPONENTS: Storage Tanks, Low Pressure[2] |
||||||
| PRO3800 | ||||||
| PRO4000 | ||||||
|
  [2] Conforms to the materials and structural integrity requirements only. |
||||||
| Kent RO Systems Ltd. | |
| A-2, Sector-59 | |
| Noida (UP) 201309 | |
| India | |
| 91 120 307 5000 | |
| Visit this company's website |
Facility : # 2 India
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Kent Excell + Mineral RO | 20011 20012 20001 20015 20003 |
19.8 | TDS Reduction | |||
| Kent Grand Mineral RO System | 20001 20015 20003 20009 20010 |
19.8 | TDS Reduction | |||
| Kent Pearl Mineral RO System | 20001 20015 20003 20009 20008 |
19.8 | TDS Reduction | |||
| Kent Prime[1] | 20010 20009 20003 20002 20015 |
19.8 | TDS Reduction | |||
| Kent Prime TC Mineral RO[1] | 20010 20009 20003 20002 20015 |
19.8 | TDS Reduction | |||
| Kent Sterling Mineral RO / 1093 | 20002 20004 20009 20010 20018 |
19.8 | TDS Reduction | |||
| Kent Supreme Mineral RO | 20001 20015 20003 20009 20008 |
19.8 | TDS Reduction | |||
|
  [1] Flush for 24 hours before use. |
||||||
|
COMPONENTS: Membrane Elements[2] |
||||||
| RO membrane Kent 75 GPD | ||||||
|
  [2] Conforms to material requirements only. |
||||||
| Kohler (China) Investment Co., Ltd. | |
| No.158, Jiang Chang San Road | |
| Zhabei District, Shanghai 200436 | |
| China | |
| 86 21 2606 2721 |
Facility : Fujian, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In |
||||||
| KP040 | 80031T-R1-01R 80031T-R2-01R 80031T-R3-01R |
382.83 | TDS Reduction | |||
| KP050 | 80041T-R1-01R 80041T-R2-01R 80041T-R3-01R |
474.77 | TDS Reduction | |||
| RO400-A | 80031T-R1-01R 80031T-R2-01R 80031T-R3-01R |
382.83 | TDS Reduction | |||
| RO400-C | 80031T-R1-01R 80031T-R2-01R 80031T-R3-01R |
382.83 | TDS Reduction | |||
| RO400-D | 80031T-R1-01R 80031T-R2-01R 80031T-R3-01R |
382.83 | TDS Reduction | |||
| RO400-E | 80031T-R1-01R 80031T-R2-01R 80031T-R3-01R |
382.83 | TDS Reduction | |||
| RO400-L | 80031T-R1-01R 80031T-R2-01R 80031T-R3-01R |
382.83 | TDS Reduction | |||
| RO400-X | 80031T-R1-01R 80031T-R2-01R 80031T-R3-01R |
382.83 | TDS Reduction | |||
| Kouw Pinnq Ent. Co., Ltd. (C.C.K.) | |
| No. 766, Section 4, Jung Ching Road | |
| Taya District, Taichung City | |
| Taiwan | |
| 886 4 2560 0828 | |
| Visit this company's website |
Facility : # 1 Taichung City, Taiwan
|
COMPONENTS: Filter Housings[1] |
||||||
| (V)(WWW)-(XX)(Y)-(ZZ) | ||||||
|
  [1] Slim housings
(V) - Body color (white, blue, or black)
(WWW) - Model (892, 893, 894, 889, 905, 913)
(XX) - Slim cap color/Style: BKR (black), WR (white), BR (blue), BKF (black flat),
WF (white flat), BF (blue flat)
(Y) - Slim cap port size: 1/4", 3/8", or 1/2" (905 is approved for 1/4" and 3/8"
only)
Standard housings
(V) - Standard housings: Body color (white, blue, or black)
(WWW) - Model (890, 891, 910)
(XX) - Standard cap color/Style: BKR (black), WR (white)
(Y) - Standard cap port size: 3/8", 1/2" , 3/4"
(ZZ) - Standard Pressure Relief Button - PR
Big Flow housings
(V) - Big flow housings: Body color (white, blue, or black)
(WWW) - Model (907, 908, 909)
(XX) - Big flow cap color/Style: BK (Black), W (White)
(Y) - Big flow cap port size: 3/4, 1, 1-1/2, 1-1/4
(ZZ) - Big flow pressure relief button: - PR
|
||||||
|
COMPONENTS: Membrane Pressure Vessels[2] |
||||||
| MH-35DW | ||||||
| MH-35SW | ||||||
| MH-35SW-EZ | ||||||
|
  [2] Certified for material and structural requirements only. |
||||||
|
COMPONENTS: Storage Tanks, Low Pressure[2] |
||||||
| TK-3200[3] | ||||||
| TK-3500[3] | ||||||
| TK-3600 | ||||||
| TK-4000[3] | ||||||
| TK-4200[3] | ||||||
|
  [2] Certified for material and structural requirements only. [3] As of 1/24/17. |
||||||
|
COMPONENTS: Valves, Automatic Shut-off[2] |
||||||
| SV-A-14W-EZ | ||||||
|
  [2] Certified for material and structural requirements only. |
||||||
Facility : # 2 Taichung City, Taiwan
|
COMPONENTS: Tubing[1] [2] |
||||||
| TU-2B | ||||||
| TU-2BK | ||||||
| TU-2G | ||||||
| TU-2O | ||||||
| TU-2R | ||||||
| TU-2W | ||||||
| TU-2Y | ||||||
| TU-3B | ||||||
| TU-3BK | ||||||
| TU-3G | ||||||
| TU-3O | ||||||
| TU-3R | ||||||
| TU-3W | ||||||
| TU-3Y | ||||||
| TU-4B | ||||||
| TU-4W | ||||||
|
  [1] Certified for material and structural requirements only.
[2] The tubing is sold in coils of 500 ft. or up to defined length. However, Listed tubing
has the following length restrictions and must be cut to meet the following
restrictions:
TU-2W (0.25" OD) - maximum length of 68"
TU-3W (0.375" OD) - maximum length of 40"
TU-2Y (0.25" OD) - maximum length of 68"
TU-3Y (0.375" OD) - maximum length of 40"
|
||||||
| Lan Shan Enterprise Co., Ltd. | |
| No. 20, Alley 84, Lane 350 | |
| Siaoyi Road, Hemei Township | |
| Changhua County 508 | |
| Taiwan | |
| 886 47330 158 |
Facility : Hsinchu County, Taiwan
|
COMPONENTS: Membranes[1] |
||||||
| NF90-1812-100 | ||||||
| NF90-1812-60 | ||||||
| TW30-1812-50 | ||||||
| TW30-1812-75 | ||||||
| TW30-2012-100 | ||||||
| TW30-2012-125 | ||||||
| TW30-2012-180 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Lancaster Water Treatment | |
| 1340 Manheim Pike | |
| Lancaster, PA 17601-3196 | |
| United States | |
| 717-397-3521 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| CRO-350 | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| LRO-35[1] [2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| PRO-50 | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] As of 05/28/2004.
[2] Serial number of 180000 or higher.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| LG Chem, Ltd. | |
| LG Twin Towers | |
| 128, Yeouidaero, Yeongdeungpo-gu | |
| Seoul 150-721 | |
| Korea, Republic of | |
| 82 43 261 7532 | |
| Visit this company's website |
Facility : Chungbuk, Republic of Korea
|
COMPONENTS: Flat Sheet Membranes[1] |
||||||
| LGTWFS-35[2] | ||||||
| LGTWFS-35-1[3] | ||||||
| LGTWFS-50[2] | ||||||
| LGTWFS-50-1[3] | ||||||
| LGTWFS-80[2] | ||||||
| LGTWFS-80-1[3] | ||||||
| LGTWFS-85[2] | ||||||
| LGTWFS-100[2] | ||||||
| LGTWFS-100-1[3] | ||||||
| LG BW UES_1[3] | ||||||
| LG BW UES[2] | ||||||
|
  [1] Conforms to material requirements only. [2] Certified for a maximum surface area to volume ratio of 11.4 sq. ft./L. [3] Certified for a maximum surface area to volume ratio of 3.83 sq. ft./L. |
||||||
|
COMPONENTS: Membrane Elements[1] [Pb] |
||||||
| LGTWRO-3012-400 | ||||||
| LGTWRO-2012-150[4] | ||||||
| LGTWRO-2012-100[4] | ||||||
| LGTWRO-1812-150 | ||||||
| LGTWRO-1812-80[4] | ||||||
| LGTWRO-1812-50[4] | ||||||
| LGTWRO-1812-35[4] | ||||||
| LGTWRO-1810-80[4] | ||||||
| LGTWRO-1810-50[4] | ||||||
| LGTWRO-1810-35[4] | ||||||
| LGTWRO-2012-125[4] | ||||||
| LGTWRO-1812-100[4] | ||||||
| LGTWRO-2008-20[4] | ||||||
| LGTWRO-1605-20[4] | ||||||
| LGTWRO-1806-20[4] | ||||||
|
  [1] Conforms to material requirements only.
[4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
Nitrate/Nitrite, and Selenium. The test data results may be transferred to other
manufacturer's systems, if the systems meet the requirements contained in the document
entitled "Transfer of Performance Claims for LG Chem, Ltd. Reverse Osmosis Elements".
This document is available from LG Chem, Ltd.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Likuan Hardware Industrial Co., Ltd. | |
| No.79-58, Liaocuo Lane | |
| Lukang Township | |
| Changhua Hsien 505 | |
| Taiwan | |
| 886 4 772 2201 | |
| Visit this company's website |
Facility : Changhua Hsien, Taiwan
|
COMPONENTS: Faucets |
||||||
| NCP(1L)(2A)(3)(4)(5)(6)-(7)-POU[2] | ||||||
| NCP(1L)(2A)(3)TA(5)(6)-(7)-POU[2] | ||||||
| NCP(1M)(2B)(3)AG(4)(5)(6)-(7)-POU[2] | ||||||
| NCP(1M)(2B)(3)AGTA(5)(6)-(7)-POU[2] | ||||||
| NP(1D)(2)(3)(4)(5)(6)-(7)-POU[3] | ||||||
| NPB(1F)(2)(3)AGTA(5)(6)-(7)-POU[3] | ||||||
| NP(1K)(2)(3)AG(4)(5)(6)-(7)-POU[3] | ||||||
| NP(1K)(2)(3)AGTA(5)(6)-(7)-POU[3] | ||||||
| NPB(1E)(2)(3)(4)(5)(6)-(7)-POU[3] | ||||||
| NPB(1E)(2)(3)TA(5)(6)-(7)-POU[3] | ||||||
| NPB(1F)(2)(3)AG(4)(5)(6)-(7)-POU[3] | ||||||
| NP(1D)(2)(3)TA(5)(6)-(7)-POU[3] | ||||||
|
  [2] 1L - Faucet type (60, 70, 71, 80, 88, 90, or S8)
60 - Body 1193
70 - Body 1194 w/handle 1616
71 - Body 1194 w/handle 1648
80 - Body 1191 w/handle 1602
88 - Body 1191 w/handle 1606
90 - Body 1192
S8 - Body 11161-2, 11213
1M - Faucet type (60, 70, 80, 88, 90, or S8)
60 - Body 1183
70 - Body 1185 w/handle 1616
71 - Body 1185 w/handle 1648
80 - Body 1179 w/handle 1602
88 - Body 1179 w/handle 1606
90 - Body 1181
S8 - Body 11163-2, 11215
2A - Spout type (0, 1, 2, 3, 4, 5, 6, 7, or 8)
0 - Assembly 1353, 1377, 1353S, and 1377S
1 - Assembly 1308, 1319, 1348, 1308S, 1319S, or 1348S
2 - Assembly 1309, 1314, 1350, 1357, 1309S, 1314S, 1350S, or 1357S
3 - Assembly 1301, 1307, 1312, 1313, 1335, 1338, 1346, 1349, 1358, 1301S,
1307S, 1312S, 1313S, 1335S, 1338S, 1346S, 1349S, or 1358S
4 - Assembly 1304, 1339, 1347, 1304S, 1339S, or 1347S
5 - Assembly 1305 or 1305S
6 - Assembly 1315, 1317, 1315S, or 1317S
7 - Assembly 1327 or 1327S
8 - Assembly 1303, 1359, 1303S, or 1359S
3 - Material (N, SS, or Blank)
N - Both body and spout made with non-lead brass
SS - Both body and spout made with stainless steel
Blank - Low lead brass body and non-lead brass spout
4 - Connector type (PI or Blank)
PI - Push-in connector
Blank - Standard
5 - Tube length (4" maximum)
2 - 2"
3 - 3"
4 - 4"
X - 1.5"
Y - 2.5"
Z - 3.5"
6 - Finish (Any two alpha characters)
AB - Antique brass
AW - Antique wine
AZ - Antique bronze
BB - Bright black
BD - Brushed
BE - Blue
BG - Bright golden
CP - Chrome plated
GY - Gray
IY - Ivory
NP - Brushed nickel
OB - Oil rubbed bronze
PD - Polished
RD - Red
ST - Satin nickel
TB - Tuscan bronze
WE - White
YB - Yellowish brown
7 - All products may also include 5 characters maximum for customer identification.
[3] 1D - Faucet type (30, 40, or AO)
30 - Body 1151
40 - Body 1197
A0 - Body 1199
1E - Faucet type (30)
30 - Body 1190
1F - Faucet type (30)
30 - Body 1153
1K - Faucet type (30, 40, or A0)
30 - Body 11162
40 - Body 11164
A0 - Body 11165
2 - Spout type (0, 1, 2, 3, 4, 5, 6, or 7)
0 - Assembly 1353, 1377, 1353S, or 1377S
1 - Assembly 1308, 1319, 1348, 1308S, 1319S, or 1348S
2 - Assembly 1309, 1314, 1350, 1357, 1309S, 1314S, 1350S, or 1357S
3 - Assembly 1301, 1307, 1312, 1313, 1335, 1338, 1346, 1349, 1358, 1301S,
1307S, 1312S, 1313S, 1335S, 1338S, 1346S, 1349S, or 1358S
4 - Assembly 1304, 1347, 1339, 1304S, 1347S, or 1339S
5 - Assembly 1305 or 1305S
6 - Assembly 1315, 1317, 1315S, or 1317S
7 - Assembly 1327 or 1327S
3 - Material (N, SS, or Blank)
N - Both body and spout made with non-lead brass
SS - Both body and spout made with stainless steel
Blank - Low lead brass body and non-lead brass spout
4 - Connector type (PI or Blank)
PI - Push-in connector
Blank - Standard
5 - Tube length (4" maximum)
2 - 2"
3 - 3"
4 - 4"
X - 1.5"
Y - 2.5"
Z - 3.5"
6 - Finish (Any two alpha characters)
AB - Antique brass
AW - Antique wine
AZ - Antique bronze
BB - Bright black
BD - Brushed
BE - Blue
BG - Bright golden
CP - Chrome plated
GY - Gray
IY - Ivory
NP - Brushed nickel
OB - Oil rubbed bronze
PD - Polished
RD - Red
ST - Satin nickel
TB - Tuscan bronze
WE - White
YB - Yellowish brown
7 - All products may also include a code of 5 characters for customer identification.
|
||||||
| Linyi Lurun Tanklife Water Purification Equipment Co., Ltd. | |
| Interchange of Xinhua Street and | |
| Ehuang Street, New High Tech Area | |
| Linyi, Shandong 276000 | |
| China | |
| 86 539 205 2790 | |
| Visit this company's website |
Facility : Shandong, China
|
COMPONENTS: Storage Tanks, Low Pressure[1] [2] |
||||||
| TL 15P[3] | ||||||
| TL 16P[3] | ||||||
| TL 19P[3] | ||||||
| TL 3.2G[4] | ||||||
| TL 4.0G[4] | ||||||
| TL RO11G[3] | ||||||
| TL RO132[3] | ||||||
| TL RO20G[3] | ||||||
|
  [1] TL - TANKLIFE Brand Name, number represents the size of tank. [2] Certified for material and structural requirements. [3] Max Rated Pressure: 100 PSI [4] Max Rated Pressure: 35 PSI |
||||||
| Longkou Lijia Electric Co., Ltd. | |
| Longshui Road | |
| The Economic & Development Zone | |
| Longkou, Shandong 265700 | |
| China | |
| 86 159 0545 9256CELL |
Facility : Shandong, China
|
COMPONENTS: RO Booster Pump[1] [Pb] |
||||||
| CS-0580-CJK | ||||||
| CS-0580AR-100 | ||||||
| CS-0580D(a) | ||||||
| CS-0580D(ß) | ||||||
| CS-0580M-AQ | ||||||
| CS-0580Q(I) | ||||||
| CS-0580Q(P) | ||||||
| CS-0580Q(a) | ||||||
| CS-0580Q(ß) | ||||||
| CS-0580Q-AQ | ||||||
| CS-0580Q-WE | ||||||
| CS-0580YM-50 | ||||||
| CS-0580YM-75 | ||||||
| CS-0580YQ-100 | ||||||
| LJB-0560-50 | ||||||
| LJB-0560-75 | ||||||
| LJB-0560-100 | ||||||
| LJB-0590-300 | ||||||
| LJB-0590-400/24V | ||||||
| LJB-0590-400/36V | ||||||
| LJB-0590-600 | ||||||
| LJB-0590-800 | ||||||
|
  [1] Conforms to material requirements and structual integrity requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Marlo Incorporated | |
| 2227 South Street | |
| P.O. Box 044170 | |
| Racine, WI 53404-7003 | |
| United States | |
| 262-681-1300 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| TFC-35[1] | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| TFC-35M[1] | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] As of 05/28/2004.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Marmon Water Foodservice | |
| 55 Railroad Avenue | |
| West Haven, CT 06516 | |
| United States | |
| 203-799-4772 |
Facility : Plymouth, MN
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Commercial Modular[Pb] |
||||||
| MODRO-300BL | CB-20CLL RO-500 CB20C |
101.55 | TDS Reduction | |||
| MODRO-300ES | CB-20CLL RO-500 CB20C |
101.55 | TDS Reduction | |||
| MODRO-300ST | CB-20CLL RO-500 CB20C |
101.55 | TDS Reduction | |||
| MODRO-500BL | CB-20CLL RO-500 CB20C |
288.11 | TDS Reduction | |||
| MODRO-500ES | CB-20CLL RO-500 CB20C |
288.11 | TDS Reduction | |||
| MODRO-500ST | CB-20CLL RO-500 CB20C |
288.11 | TDS Reduction | |||
|
  [Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Master Water Conditioning, Inc. | |
| 224 Shoemaker Road | |
| Pottstown, PA 19464 | |
| United States | |
| 610-323-8358 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Puro-35T[1] [2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] As of 05/28/2004.
[2] Serial number of 180000 or higher.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| MCM Co., Ltd. | |
| 486, Jingwang-ro, Iwol-myeon | |
| Jincheon-gun, Chungcheongbukdo 365-842 | |
| Korea, Republic of | |
| 82 43 531 7021 |
Facility : Chungcheongbukdo, Republic of Korea
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| M9 4HA RO 50GPD | M92512 CB-FR M92512 SED-FR M92512 RO50-FR |
23.39 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| M9 4HA RO 75GPD | M92512 CB-FR M92512 SED-FR M92512 RO75-FR |
30.64 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| M9 4SS RO 50GPD | M92512 CB-FR M92512 SED-FR M92512 RO50-FR |
54.44 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| M9 4SS RO 75GPD | M92512 CB-FR M92512 SED-FR M92512 RO75-FR |
66.35 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. |
||||||
|
COMPONENTS: Fittings[1] |
||||||
| BHA1414G01 | ||||||
| BHA1414W01 | ||||||
| BHA3838G01 | ||||||
| BHA3838W01 | ||||||
| LAA1402G01 | ||||||
| LAA1402W01 | ||||||
| LEA1414G01 | ||||||
| LEA1414W01 | ||||||
| LEA3838G01 | ||||||
| LEA3838W01 | ||||||
| LRA3814G01 | ||||||
| LRA3814W01 | ||||||
| LSA1414G01 | ||||||
| LSA1414W01 | ||||||
| LSA3838G01 | ||||||
| LSA3838W01 | ||||||
| SEA1414G01 | ||||||
| SEA1414W01 | ||||||
| SEA3838G01 | ||||||
| SEA3838W01 | ||||||
| SEA5151G01 | ||||||
| SRA3814G01 | ||||||
| SRA3814W01 | ||||||
| SRA5114G01 | ||||||
| SSA5114G01 | ||||||
| SSA5114W01 | ||||||
| TEA1414G01 | ||||||
| TEA1414W01 | ||||||
| TEA3838G01 | ||||||
| TEA3838W01 | ||||||
| TEA5151G01 | ||||||
|
  [1] (XXX)(aa)(bb)(cc)01
XXX - Fitting configuration
BHA - Bulkhead
LAA - A-Elbow
LEA - Elbow (1/4" or 3/8")
LRA - Elbow (1/4" & 3/8")
LSA - Stem
SCA - Straight check valve
SEA - Straight (1/4" or 3/8")
SRA - Straight (1/4" & 3/8")
SSA - Straight (single inlet)
TEA - Tee
aa - Inlet size
02 - Threading
14 - 1/4"
38 - 3/8"
51 - 5/16"
bb - Outlet size
02 - Threading
14 - 1/4"
38 - 3/8"
51 - 5/16"
cc - Fitting color
G - Gray
W - White
|
||||||
|
COMPONENTS: Membrane Elements |
||||||
| 1812-50[3] | ||||||
| 1812-75[3] | ||||||
| 1812S-50[3] | ||||||
| 1812S-75[3] | ||||||
| BW60-1807-40[2] | ||||||
| BW60-1812-100[2] | ||||||
| BW60-1812-150[2] | ||||||
| BW60-1812-50[2] | ||||||
| BW60-1812-75[2] | ||||||
| TW-1807-50[4] | ||||||
| TW-1812-100[4] | ||||||
| TW-1812-150[4] | ||||||
| TW-1812-50[4] | ||||||
| TW-1812-75[4] | ||||||
| TW-1906-50[4] | ||||||
| TW-1907-60[4] | ||||||
| TW-1908-80[4] | ||||||
| TW30-1509-50[4] | ||||||
| TW30-1510-50[4] | ||||||
| TW30-1609-50[4] | ||||||
| TW30-1708-50[4] | ||||||
| TW30-1709-80[4] | ||||||
| TW30-1710-50[4] | ||||||
| TW30-1805-40[4] | ||||||
| TW30-1807-20[2] | ||||||
| TW30-1807-20[4] | ||||||
| TW30-1807-50[4] | ||||||
| TW30-1807-50P[2] | ||||||
| TW30-1807-60P[2] | ||||||
| TW30-1809-80[4] | ||||||
| TW30-1810-80[4] | ||||||
| TW30-1811-80[4] | ||||||
| TW30-1812-100[4] | ||||||
| TW30-1812-150[4] | ||||||
| TW30-1812-50[4] | ||||||
| TW30-1812-75[4] | ||||||
| TW30-1812-80[4] | ||||||
| TW30-1906-50[4] | ||||||
| TW30-1907-60[4] | ||||||
| TW30-1908-80[4] | ||||||
| TW30-1909-100[4] | ||||||
|
  [2] Conforms to material requirements only. Membrane requires a 24 hour flushing and
conditioning procedure.
[3] These elements have been tested for the reduction of TDS in a surrogate system.
[4] TW30-1812-50, TW30-1812-75 have been tested for the reduction of Arsenic, Barium,
Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium
226/228, Selenium, Turbidity, and TDS. The test data results may be transferred to
other manufacturer's systems, if the systems meet the requirements contained on the
document entitled "Transfer of Performance Claims for MCM Co., Ltd. Reverse Osmosis
Elements", dated 10/10/2013. This document is available from MCM Co., Ltd. A data
transfer has been accepted for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228, Selenium,
Turbidity, and TDS.
|
||||||
|
COMPONENTS: Valves, Check[1] |
||||||
| SCA1414G21 | ||||||
| SCA1414G25 | ||||||
|
  [1] (XXX)(aa)(bb)(cc)01
XXX - Fitting configuration
BHA - Bulkhead
LAA - A-Elbow
LEA - Elbow (1/4" or 3/8")
LRA - Elbow (1/4" & 3/8")
LSA - Stem
SCA - Straight check valve
SEA - Straight (1/4" or 3/8")
SRA - Straight (1/4" & 3/8")
SSA - Straight (single inlet)
TEA - Tee
aa - Inlet size
02 - Threading
14 - 1/4"
38 - 3/8"
51 - 5/16"
bb - Outlet size
02 - Threading
14 - 1/4"
38 - 3/8"
51 - 5/16"
cc - Fitting color
G - Gray
W - White
|
||||||
| Membrane Solutions LLC | |
| No. 197 Ruixing Road | |
| NETDA Nantong, Jiangsu Province | |
| China | |
| 86 513 8152 3002 | |
| Visit this company's website |
Facility : Shanghai, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| ROULP-1812-50 | ||||||
| ROULP-1812-75 | ||||||
| ROULP-1812-80 | ||||||
| ROULP-2012-100 | ||||||
| ROULP-3012-400 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Microfilter Co., Ltd. | ![]() |
| 15-1, Gwinong 3-gil, Deoksan-myeon | |
| Jincheon-gun | |
| Chungcheongbuk-do 27856 | |
| Korea, Republic of | |
| 82 43 536 5221 | |
| Visit this company's website |
Facility : # 1 Chungcheongbuk-do, Republic of Korea
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| M9 4HA RO 50GPD | M92512 CB-FR M92512 SED-FR M92512 RO50-FR M92512 GC-FR M92512 GM-FR |
23.39 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| M9 4HA RO 75GPD | M92512 CB-FR M92512 SED-FR M92512 RO75-FR M92512 GC-FR M92512 GM-FR |
30.64 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| M9 4SS RO 50GPD | M92512 CB-FR M92512 SED-FR M92512 RO50-FR M92512 GC-FR M92512 GM-FR |
54.44 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| M9 4SS RO 75GPD | M92512 CB-FR M92512 SED-FR M92512 RO75-FR M92512 GC-FR M92512 GM-FR |
66.35 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Microline | |
| 4462 Duraform Lane | |
| Windsor, WI 53598-9716 | |
| United States | |
| 608-846-3010 |
Facility : Windsor, WI
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| T.F.C.-335[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-335FS[1] | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-335FSX[2] | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-335X[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-3PL[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-3PLX[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-435[1] [2] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-435FFSX | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| T.F.C.-435FSX | S1340RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| T.F.C.-435RC | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-435X[1] | S1229RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-4PL[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-4PLF[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| T.F.C.-4PLX[1] [2] | S1448RS | 11 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] As of 05/28/2004.
[2] Serial number of 180000 or higher.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Ningbo Hidrotek Co Ltd. | |
| District A | |
| Zhenhai Economic Development Zone | |
| Ningbo, Zhejiang 315200 | |
| China | |
| 86 057426267890 | |
| Visit this company's website |
Facility : Ningbo, Zhejiang, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| HIDROTEK 50G | ||||||
| HIDROTEK 75G | ||||||
| HIDROTEK 100G | ||||||
| HIDROTEK 200G | ||||||
| HIDROTEK 300G | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 48 hour flushing procedure. |
||||||
| North Star Water Treatment Systems | |
| 1890 Woodlane Drive | |
| Woodbury, MN 55125 | |
| United States | |
| 800-972-0136 |
Facility : Iuka, MS
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] [Pb] |
||||||
| NS175EU | 7287514 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Fluoride Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
| NS175TU | 7287514 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Fluoride Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
| NSRO42C4 | 7287514 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Fluoride Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Conforms to material requirements only. Membrane requires a 24 hour flushing and
conditioning procedure.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Olympia Water Systems LLC | |
| 25 South 51st Avenue | |
| Phoenix, AZ 85043 | |
| United States | |
| 602-278-1100 |
Facility : # 1 China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| OROS-50[1] [Pb] | OROS-ROM50 OROS-PRESF OROS-PRECB OROS-POST |
16.79 | TDS Reduction | |||
| OROS-80[1] [Pb] | OROS-ROM80 OROS-PRESF OROS-PRECB OROS-POST |
20.72 | TDS Reduction | |||
|
  [1] Tested in accordance with NSF/ANSI Standard 42 for Chlorine Reduction and Taste and Odor
Reduction with OROS-POST post-filter for 2500 gallon capacity.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Omnipure Filter Co. | |
| 1904 Industrial Way | |
| Caldwell, ID 83605 | |
| United States | |
| 208-454-2597 | |
| Visit this company's website |
Facility : Caldwell, ID
|
COMPONENTS: Membrane Elements, Encapsulated |
||||||
| K5670[1] | ||||||
|
  [1] Conforms to material and structural integrity requirements only. |
||||||
| Osmotik / Osmosis Technology, Inc. | |
| 6900 Hermosa Circle | |
| Buena Park, CA 90620 | |
| United States | |
| 800-541-6565 | |
| 714-670-9303 |
Facility : Buena Park, CA
|
COMPONENTS: Membrane Elements[1] [2] |
||||||
| 7165762 | ||||||
| 7210046 | ||||||
| 7223586 | ||||||
| 7260350 | ||||||
| 7262598 | ||||||
| 7266047 | ||||||
| 7266152 | ||||||
| 7269388 | ||||||
| 7272828 | ||||||
| 7273280 | ||||||
| T112N-(1)(2)(3)(4)[3] | ||||||
| T112N-(2) TW[3] | ||||||
| T112N-XX-HR[4] | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 24 hour flushing and
conditioning procedure.
[2] (1) Denotes production rates in GPD (15-150)
(2) Denotes D for Dry (optional suffix)
(3) Denotes membrane type: BW for Brackish Water or TW for Tap Water (optional suffix)
(4) Denotes options: FC - Flow control, CV - Check valve, FV - Flow control & check
valve (optional suffix)
[3] (1) Denotes body fitting styles: TK or K - straight female quick disconnect, TS or S -
standard 90o female quick disconnect (optional suffix)
(2) Denotes production rates in GPD (15-150)
(3) Denotes FF for Full Fit (optional suffix)
(4) Denotes flow direction: BC - body to cap, CB - cap to body (optional suffix)
(5) Denotes type: OMNI or D2 (optional suffix)
(6) Denotes options: FC - Flow control, CV - Check valve, FV - Flow control & check
valve (optional suffix)
XX - Production rates, 15-100 gpd.
[4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium,
Chromium (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228,
Selenium, Turbidity, and TDS. The test data results may be transferred to other
manufacturer's systems, if the systems meet the requirements contained on the document
entitled, "Data Transfer Procedure for Devices using Osmotik / Osmosis Technology
Reverse Osmosis". This document is available from Osmotik / Osmosis Technology.
XX - Production rates, 15-100 gpd.
|
||||||
|
COMPONENTS: Membrane Elements, Encapsulated[3] [5] |
||||||
| T300-(2)(4)(5)(6) | ||||||
| TK56(1)-(2)(3)(4)(5)(6) | ||||||
| TQ56(1)-(2)(3)(4)(5)(6) | ||||||
|
  [3] (1) Denotes body fitting styles: TK or K - straight female quick disconnect, TS or S -
standard 90o female quick disconnect (optional suffix)
(2) Denotes production rates in GPD (15-150)
(3) Denotes FF for Full Fit (optional suffix)
(4) Denotes flow direction: BC - body to cap, CB - cap to body (optional suffix)
(5) Denotes type: OMNI or D2 (optional suffix)
(6) Denotes options: FC - Flow control, CV - Check valve, FV - Flow control & check
valve (optional suffix)
XX - Production rates, 15-100 gpd.
[5] Conforms to material and structural integrity requirements only. Membranes require a 24
hour flushing and conditioning procedure.
|
||||||
| Paragon Water Systems, Inc. | |
| 13805 Monroes Business Park | |
| Tampa, FL 33635 | |
| United States | |
| 727-538-4704 | |
| Visit this company's website |
Facility : # 2 Zhongshan, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| TLRO4H50T | TLROMC50T | 21.60 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| TLRO4H75T | TLROMC75T | 27.17 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. |
||||||
| Parker Hannifin Mfg France SAS | ![]() |
| TVA FR 79 523 394 724 | |
| 74 Rue de Paris - BP 70411 | |
| 35704 Rennes Cedex 7 | |
| France | |
| 33 299 255500 | |
| Visit this company's website |
Facility : Northern Ireland, United Kingdom
|
COMPONENTS: Tubing[1] [2] |
||||||
| 1AAAYBBFZZDD | ||||||
|
  [1] Conforms to material and structural integrity requirements only.
[2] 1: Internal Legris SA reference to tubing products.
AAA: Spool length sold to customers that range from 1-1000 meters.
Y: Internal Legris SA reference to the base material.
BB: Outside diameter (O.D.) of tubing (with standard inner diameter (I.D.)).
04 - 4mm (with I.D. 2.5 mm)
06 - 6mm (with I.D. 4 mm)
08 - 8mm (with I.D. 6 mm)
10 - 10mm (with I.D. 7 mm)
12 - 12mm (with I.D. 9 mm)
56 - 1/4" (with I.D. 4.32 mm)
60 - 3/8" (with I.D. 6.35 mm)
62 - 1/2" (with I.D. 9.55 mm)
F: Internal Legris SA reference for FDA approval.
ZZ: Color of tubing.
00 - natural
01 - black
02 - green
03 - red
04 - blue
05 - yellow
07 - orange
09 - purple
10 - white
DD: Inner diameter (I.D.) of tubing; only used if inner diameter is different than the
standard measurement. The inner diameter will range from 1.8 mm to 9.9 mm (18-99).
|
||||||
| PEIQUAN CO., LTD. / ZHEJIANG TANKPRO INDUSTRY CO., LTD. | |
| 321 Ren-Ai Road | |
| Zhong-Zhuang, Da-Liao | |
| Kaohsiung | |
| Taiwan | |
| 886 7 7019909 |
Facility : Zhejiang, China
|
COMPONENTS: Storage Tanks, Low Pressure[1] [2] |
||||||
| PRO-0.8 | ||||||
| PRO-11 | ||||||
| PRO-2 | ||||||
| PRO-2.2 | ||||||
| PRO-2.8 | ||||||
| PRO-20 | ||||||
| PRO-28 | ||||||
| PRO-3.2 | ||||||
| PRO-3.2N | ||||||
| PRO-30 | ||||||
| PRO-40 | ||||||
| PRO-6.5 | ||||||
| RO-2236 P[3] | ||||||
| RO-2337 (3.2 g) | ||||||
| RO-2640 P[3] | ||||||
| RO-2839 | ||||||
|
  [1] Conforms to material and structural integrity requirements only.
[2] The unit volume of PRO-2.8 is 3.2 gallon.
The unit volume of PRO-3.2 and PRO-3.2N is 4.4 gallon.
The unit volume of PRO-6.5 is 6.5 gallon.
The unit volume of PRO-30 is 115L.
The unit volume of PRO-40 is 150L.
The unit volume of PRO-2839 is 19L.
[3] P suffix indicates plastic.
|
||||||
| Pentair Residential Filtration, LLC | |
| 13845 Bishops Drive | |
| Suite 200 | |
| Brookfield, WI 53005 | |
| United States | |
| 800-279-9404 | |
| 262-238-4400 |
Facility : Hanover Park, IL
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Everpure Residential ROM IV[Pb] | ROM-PRE ROM-G75 ROM-PST ROM-PFK |
14.66 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Cyst Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Facility : Jiangzu Province, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| American Plumber WRO-2550 | WROM-50T W5P WEPM WIC WRO45R |
15.04 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| OmniFilter RO2050[1] [2] | CB1 OM1 R200 Series A ROR2000 RS14 ROR2050 |
15.04 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| Pentair GRO-2550 | GS10-RO P5 EPM-10 GRO-50EN |
10.09 | Cyst Reduction TDS Reduction |
|||
| Pentair GRO-350B | FDF1-RC GRO50-RC F1GC-RC |
14.96 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-350BP | FDF1-RC GRO50-RC F1GC-RC |
99.08 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-350M | FDF1-RC GRO50-RC F1GC-RC |
14.96 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-475B | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-475BP | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
94.38 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-475M | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-575B | FDF1-RC GRO75-RC F2B2-RC2 F1GC-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-575M | FDF1-RC GRO75-RC F2B2-RC2 F1GC-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair RO-2550 | TLC-50 P5 EPM-10 GS-10RO |
15.04 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] ROR2000 is a replacement kit containing RS14, CB1, and two o-rings.
[2] ROR2050 is a replacement kit containing R200, CB1, RS14, and two o-rings.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Membrane Elements[3] |
||||||
| Pentair TLC-100[4] | ||||||
| Pentair TLC-24[4] | ||||||
| Pentair TLC-36[4] | ||||||
| Pentair TLC-50[4] | ||||||
| Pentair TLC-50F[4] | ||||||
| Pentair TLC-75[4] | ||||||
| Pentair TLC-75I[4] | ||||||
|
  [3] Conforms to material requirements only. Membranes require a 24 hour flushing and
conditioning procedure.
[4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
and Selenium. The test data results may be transferred to other manufacturer's systems,
if the systems meet the requirements.
|
||||||
|
COMPONENTS: Membrane Elements, Encapsulated[4] [5] |
||||||
| Pentair GRO-36EN | ||||||
| Pentair GRO-50EN | ||||||
| Pentair GRO-75EN | ||||||
|
  [4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
and Selenium. The test data results may be transferred to other manufacturer's systems,
if the systems meet the requirements.
[5] Conforms to material and structural integrity requirements only. Membranes require a 24
hour flushing and conditioning procedure.
|
||||||
Facility : Goa, India
|
COMPONENTS: Membranes[1] [2] |
||||||
| Pentair S1229RS[3] | ||||||
| Pentair S1340RS [3] | ||||||
| Pentair S1448RS [3] | ||||||
| Pentair TLC-100 | ||||||
| Pentair TLC-24 | ||||||
| Pentair TLC-36 | ||||||
| Pentair TLC-50 | ||||||
| Pentair TLC-50F | ||||||
| Pentair TLC-75 | ||||||
| Pentair TLC-75 PLUS | ||||||
| Pentair TLC-75I | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 24 hour flushing and
conditioning procedure.
[2] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chormium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
and Selenium. The test data results may be transferred to other manufacturer's systems,
if the systems meet the requirements.
[3] Conforms to material requirements when used in Microline or Rayne Corporation RO systems
Certified by NSF to NSF/ANSI 58.
|
||||||
| Perfect Water Technologies, Inc. | |
| 7701 East Gray Road | |
| Suite 104 | |
| Scottsdale, AZ 85260 | |
| United States | |
| 877-693-7873 | |
| 480-656-2468 | |
| Visit this company's website |
Facility : # 3 Taiwan
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| RO-105 | ||||||
| RO-1070 | ||||||
| RO-120 | ||||||
| RO-122 | ||||||
| RO-132 | ||||||
| RO-152 | ||||||
| RO-2000 | ||||||
| TP-100 | ||||||
| TP-150 | ||||||
| TP-35 | ||||||
| TP-4 | ||||||
|
  [1] Conforms to the material and structural integrity requirements. |
||||||
| Picogram Co., Ltd. | |
| 118, Bupyeongbuk-ro | |
| Bupyeong-gu | |
| Incheon 21310 | |
| Korea, Republic of | |
| 82 32 678 5114 | |
| Visit this company's website |
Facility : Incheon, Republic of Korea
|
COMPONENTS: Membrane Elements |
||||||
| EFN-ZZXX-YYY[1] | ||||||
| EFP-ZZXX-YYY[2] | ||||||
|
  [1] Denoted as follows
ZZ - Membrane diameter
15 (39mm)
16 (41mm)
18 (45 mm)
20 (48 mm)
XX - Length of Central Pipe
06 (164 mm)
08 (198 mm)
09 (210 mm)
10 (242 - 254 mm)
11 (280 mm)
12 (298 mm)
YYY - DPR (20 - 150 gal)
[2] Denoted as follows:
ZZ - Membrane diameter
16 (41mm)
18 (45 mm)
20 (48 mm)
XX - Length of Central Pipe
06 (144.5 mm)
09 (231.5 mm)
12 (256.5 mm)
YYY - DPR (30 - 150 gal)
|
||||||
| Protect Plus LLC | |
| 11515 Vanstory Drive | |
| Suite 110 | |
| Huntersville, NC 28078 | |
| United States | |
| 704-584-0704 |
Facility : Zhongshan, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Brita USS-335 | USF-205,USF-201 | 13.32 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. |
||||||
| PRS Permacel Pvt. Ltd. | |
| Plot No. 11/1 | |
| Additional Ambernath MIDC | |
| Ambernath (E), Maharashtra 421506 | |
| India | |
| 91 842 2941734 | |
| Visit this company's website |
Facility : Maharashtra, India
|
COMPONENTS: Adhesive Tape |
||||||
| P691 FITRATAPE BLUE[1] [2] | ||||||
|
  [1] Conforms to NSF/ANSI Standard 58 material safety requirements only. [2] Certified for a maximum surface area to volume ratio of 70 square inches/L. |
||||||
| PureBlueH2O, LLC | |
| 13813 Monroes Business Park | |
| Tampa, FL 33635 | |
| United States | |
| 844-787-3148 |
Facility : Zhongshan, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| AMZN-TLRO4H50T[1] | AMZN-TLRO4MC50T AMZN-TLRO4RCT |
28.13 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| PureBlueH2O PB-TLRO4H50T | PB-TLRO4MC50T PB-TLRO4SEDT PB-TLRO4CB2T PB-TLRO4CB4T |
28.13 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Product also evaluated and determined to be capable of reducing hexavalent chromium to
meet the State of California's maximum contaminant level of 0.010 g/L.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Pureteck Co., Inc. | |
| 3668 Placentia Court | |
| Chino, CA 91710 | |
| United States | |
| 909-627-0619 | |
| Visit this company's website |
Facility : Chang Hua, Taiwan
|
COMPONENTS: Faucets[1] [2] |
||||||
| F-01-XXX-AG[Pb] | ||||||
| F-01-XXX-NAG[Pb] | ||||||
|
  [1] Conforms to material and structural integrity requirements.
[2] F-01 Series number
AG - Air gap
NAG - Non air gap
XXX - Body color
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Pureteck Co., Inc. | |
| 3668 Placentia Court | |
| Chino, CA 91710 | |
| United States | |
| 909-627-0619 | |
| Visit this company's website |
Facility : # 1 China
|
COMPONENTS: RO Membrane |
||||||
| TFCK-1812-100 | ||||||
| TFCK-1812-150 | ||||||
| TFCK-1812-35 | ||||||
| TFCK-1812-50 | ||||||
| TFCK-1812-75 | ||||||
| TFCK-2812-200 | ||||||
| TFCK-3012-300 | ||||||
| TFCK-3012-400 | ||||||
| Puronics Water Systems, Inc. | |
| 5775 Las Positas Road | |
| Livermore, CA 94551 | |
| United States | |
| 800-339-8780 | |
| 925-456-7000 |
Facility : Nuevo Leon, Mexico
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| Micromax 6000 TFC | 47-124001PRI 66-5706PRI 47-55730PRI |
8.28 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
| Micromax 6500 TFC | 47-126001PRI 47-125001PRI 66-5706PRI 47-55730PRI |
8.28 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. |
||||||
| Rainwater Treatment Systems | |
| Yeni Mudanya Yolu 7 KM | |
| Cinar Is Merkezi, No. 2/7A | |
| Emek-Osmangazi, Bursa | |
| Turkey | |
| 90 224 444 0420 | |
| 90 224 241 3365 | |
| Visit this company's website |
Facility : Taichung, Taiwan
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| 9913 | ||||||
|
  [1] Conforms to the material and structural integrity requirements. |
||||||
| Rammy Trade Solutions Pvt Ltd | |
| B-3/102, Mohan Regency, Adharwadi | |
| Kalyan West, Maharashtra 421301 | |
| India | |
| 91 986 762 6346 |
Facility : # 1 China
|
COMPONENTS: Membranes[1] |
||||||
| RO-1812-50 | ||||||
| RO-1812-80 | ||||||
| RO-2012-100 | ||||||
| RO-3012-300 | ||||||
| RO-3013-400 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Rayne Corporation | |
| 4635 Ruffner Street | |
| San Diego, CA 92111 | |
| United States | |
| 858-292-1011 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| RaynePure Plus[1] [2] | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] As of 05/28/2004.
[2] Serial number of 180000 or higher.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Sears, Roebuck and Co. | |
| 3333 Beverly Road | |
| Hoffman Estates, IL 60179 | |
| United States | |
| 800-426-9345 | |
| 651-739-5330 |
Facility : Iuka, MS
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] [Pb] |
||||||
| Kenmore 625.381560 | 42-38577 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Fluoride Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
| Kenmore 625.385560 | 42-38577 | 18.46 | Arsenic (Pentavalent)<=300 ppb Reduction* Fluoride Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction Nitrate/Nitrite Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Conforms to material requirements only. Membrane requires a 24 hour flushing and
conditioning procedure.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Senwater Systems, LLC. | |
| Twentieth Floor | |
| 1300 East Ninth Street | |
| Cleveland, OH 44114 | |
| United States | |
| 216-262-0802 | |
| Visit this company's website |
Facility : Windsor, WI
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| DRO512 | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| TRO508 | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| TRO510 | S1229RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Shanghai Ozner Water Purification Science & Technology Development Co., Ltd. | |
| No. 60 Guiqiao Road | |
| Pudong, Shanghai 201206 | |
| China | |
| 86 215 032 1552 | |
| Visit this company's website |
Facility : Shaanxi, China
|
COMPONENTS: Membrane Elements, Encapsulated[1] |
||||||
| KFT-1812-50 | ||||||
|
  [1] Conforms to the material and structural integrity requirements only. Discard product
water for 2 hours before using.
|
||||||
| Shantou Ospura Co., Ltd. | |
| Second Floor, Drink-Better Building #2 | |
| North N1 Road, Free Trade Zone | |
| Shantou City, Guangdong 515000 | |
| China | |
| 86 135 34912607 |
Facility : Guangdong, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| BWT bestaqua module 12 | ||||||
| BWT bestaqua module 14 | ||||||
| BWT bestaqua module 16 | ||||||
| OSP-1810-36 | ||||||
| OSP-1810-50 | ||||||
| OSP-1810-50-A | ||||||
| OSP-1812-100 | ||||||
| OSP-1812-150 | ||||||
| OSP-1812-180 | ||||||
| OSP-1812-30-A | ||||||
| OSP-1812-36 | ||||||
| OSP-1812-50 | ||||||
| OSP-1812-50-A | ||||||
| OSP-1812-75 | ||||||
| OSP-1812-75-A | ||||||
| OSP-2812-200 | ||||||
| OSP-2812-300 | ||||||
| OSP-2813-400 | ||||||
| OSP-3012-400 | ||||||
| OSP-3012-500 | ||||||
| OSP-3012-600 | ||||||
| OSP-3012-800 | ||||||
| OSP-4012-1000 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
| Shenzhen Angel Drinking Water Industrial Group Corporation | |
| 401, No.13, Huiye Road | |
| Tangjia Community, Fenghuang St | |
| Guangming District, Shenzhen | |
| China | |
| Visit this company's website |
Facility : Guangdong, China
|
COMPONENTS: Membranes[1] [Pb] |
||||||
| TW30-3012-500 | ||||||
|
  [1] Conforms to material requirements only. Membranes require a flushing procedure: flush
for 24 hours, rest 8 hours, then flush for another 24 hours.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Shyang Yih Hardware Factory/ Shyang Sun Hardware Co., Ltd. | |
| No. 6-8, Lane 23, Section 2 | |
| Ding Cao Road, Lu Kang | |
| Chang Hua County 50543 | |
| Taiwan | |
| 886 4 771 7247 | |
| Visit this company's website |
Facility : Chang Hua County, Taiwan
|
COMPONENTS: Faucets[1] [2] [Pb] |
||||||
| NZ-6501YY-AXX | ||||||
| NZ-EEEEYY-XX | ||||||
|
  [1] EEEE - Indicates series
6301
6302
6401
6402
6403
6405
6406
6407
6408
6409
6501
6502
6503
6505
6701
6702
6703
6705
6706
6707
6708
6709
YY – Indicates outlet pipe material
BB – Outlet pipe is lead-free brass
SS – Outlet pipe is stainless steel
XX – Indicates surface treatment
AB – Antique brass
AW – Antique wind
AZ - Antique Bronze
BB – Bright black
BG – Bright golden
BD - Brushed
BE - Blue
CP – Chrome plated
GY - Gray
IY - Ivory
MB - Matte Black
NP – Polished nickel
ORB – Oil rubbed bronze
PD - Polished
RG - Rose Golden
RD - Red
ST – Satin nickel
TB - Tuscan Bronze
WE - White
YB - Yellowish Brown
[2] Conforms to material and structural integrity requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Filter Cartridges[3] [Pb] |
||||||
| B-0001 Cartridge Assembly | ||||||
|
  [3] Conforms to material requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Source Water Purification Technology Inc. | |
| 6C Yunfei Road, Gaoxin Area | |
| Hefei, Anhui 230000 | |
| China | |
| 86 551 6570 8199 | |
| Visit this company's website |
Facility : Hefei, Anhui, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| RE-1112-30 | ||||||
| RE-1112-60 | ||||||
| RE-1809-100 | ||||||
| RE-1809-50 | ||||||
| RE-1809-75 | ||||||
| RE-1810-50 | ||||||
| RE-1810-75 | ||||||
| RE-1812-30 | ||||||
| RE-1812-50 | ||||||
| RE-1812-75 | ||||||
| RE-1812-80 | ||||||
| RE-2012-100 | ||||||
| RE-2512-200 | ||||||
| RE-2812-300 | ||||||
| RE-3012-400 | ||||||
| RE-3013-300 | ||||||
| RE-3013-400 | ||||||
| RE-3013-500 | ||||||
| RE-3013-600 | ||||||
|
  [1] Conforms to the material requirements only. |
||||||
| Stormtec Co., Ltd. | |
| 263-24, Gangseo-Ro | |
| Gangseo-Gu, Seoul | |
| Korea, Republic of | |
| 82 2 2661 7517 | |
| Visit this company's website |
Facility : Seoul, Republic of Korea
|
COMPONENTS: Valves, Automatic Shut-off[1] |
||||||
| ASV-FF-140 | ||||||
|
  [1] Conforms to the material and structural integrity requirements only.
|
||||||
| SUEZ Water Technologies & Solutions | |
| 4636 Somerton Road | |
| Trevose, PA 19053 | |
| United States | |
| 888-898-6766 | |
| 215-942-3534 |
Facility : Minnetonka, MN
|
COMPONENTS: Flat Sheet Membranes[1] [2] |
||||||
| Membrane AK-HRO, FT2 | ||||||
| Membrane, AG, 41" | ||||||
| Membrane, AG-HRO, 41" | ||||||
| Membrane, AG-HRO, 41", BM | ||||||
| Membrane, AK, 41" | ||||||
| Membrane, AK-HRO, 41" | ||||||
| Membrane, AK-HRO, 41", BM | ||||||
| Membrane, AK-LE, 41" | ||||||
| Membrane, AL, 41" | ||||||
| Membrane, AP, 41" | ||||||
|
  [1] Conforms to material requirements only. [2] This membrane is certified at a maximum surface area of 4.6 square feet |
||||||
| Suzhou Origin Environmental Protection and Technology Co., Ltd. | |
| Building No. 1, No. 11 Huchen Road | |
| Suzhou New District | |
| 215151 | |
| China | |
| 86 512 6593 0255 |
Facility : Suzhou, China
|
COMPONENTS: Membranes[1] |
||||||
| RGL-R-1809-50 | ||||||
| RGL-R-1809-75 | ||||||
| RGL-R-1810-50 | ||||||
| RGL-R-1810-75 | ||||||
| RGL-R-1810-80 | ||||||
| RGL-R-1812-100 | ||||||
| RGL-R-1812-180 | ||||||
| RGL-R-1812-50 | ||||||
| RGL-R-1812-75 | ||||||
| RGL-R-1812-80 | ||||||
| RGL-R-2012-180 | ||||||
| RGL-R-2012-200 | ||||||
| RGL-R-2812-400 | ||||||
| RGL-R-2812-500 | ||||||
| RGL-R-2813-400 | ||||||
| RGL-R-2813-500 | ||||||
| RGL-R-3012-400 | ||||||
| RGL-R-3012-500 | ||||||
| RGL-R-3012-600 | ||||||
| RGL-R-3012-800 | ||||||
| RGL-R-3013-400 | ||||||
| RGL-R-3013-500 | ||||||
| RGL-R-3013-600 | ||||||
| RGL-R-3013-800 | ||||||
| RGL-R-4012-1000 | ||||||
| RGL-R-4013-1000 | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 24 hour flushing procedure. |
||||||
| SWM International | |
| 100 North Point Center East | |
| Suite 600 | |
| Alpharetta, GA 30022-8246 | |
| United States | |
| 33 02 98 06 22 29 | |
| Visit this company's website |
Facility : Quimperle, France
|
COMPONENTS: Polyethylene Terephthalate (PET)[1] [2] |
||||||
| revonex ™ | ||||||
|
  [1] Conforms to material requirements only. [2] Certified for a maximum surface area to volume ratio of 4.35 feet²/L. |
||||||
| Swun Chyan Enterprises Co., Ltd. | |
| No. 16, Lane 73, Liougu Road | |
| Wufong Hsiang | |
| Taichung 41359 | |
| Taiwan | |
| 886 4 2333 7226 | |
| Visit this company's website |
Facility : Taichung, Taiwan
|
COMPONENTS: Membrane Pressure Vessels[1] |
||||||
| RO1-0001W | ||||||
|
  [1] Conforms to material and structural integrity requirements only. |
||||||
| Swun Yuan Enterprises Co., Ltd. / Swun Yuan Filmtech Enterprises Co., Ltd. | |
| No. 9, Quanlang Lane, Zhong Zheng | |
| Road Caotun Township, Nantou 54251 | |
| Taiwan | |
| 886 49 255 0086 | |
| Visit this company's website |
Facility : Nantou, Taiwan
|
COMPONENTS: RO Membrane[1] [2] |
||||||
| TW-WWLL-ZZZVVV | ||||||
|
  [1] Certified for material and structural integrity requirements only.
[2] TW - Fixed code
WW - 18-30 Membrane element diameter in inches
LL - 7-12 Membrane element length in inches
ZZZ - 036-600 GPD
VVV - Vendor Code
|
||||||
|
COMPONENTS: RO Tank, Low Pressure[1] |
||||||
| Z-TK032 | ||||||
|
  [1] Certified for material and structural integrity requirements only. |
||||||
| Taiwan Sakura Corporation | |
| No. 436, Sec. 4, Yatan Road | |
| Daya District | |
| Taichung City 428 | |
| Taiwan | |
| 886 8 0002 1818 | |
| 886 4 2566 6106 | |
| Visit this company's website |
Facility : # 1 Taiwan
|
COMPONENTS: Membrane Elements[1] |
||||||
| C65-A011 | ||||||
|
  [1] Conforms to the material requirements only. |
||||||
| Tangshan SEAPS Science and Technology Co., Ltd. | |
| Equipment Manufacturing Park | |
| Caofeidian Industrial District | |
| Tangshan 063210 | |
| China | |
| 86 315 8827 000 | |
| Visit this company's website |
Facility : Tangshan, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| RD-1812 | ||||||
| RD-2012 | ||||||
| RD-3013 | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 4 hours flushing before use. |
||||||
| TankPAC Industries Co., Ltd. / Global Water Solutions Ltd (GWS) | |
| No. 553 Zhongshan Road | |
| Taichung 43643 | |
| Taiwan | |
| 886 4 2622 0078 |
Facility : Taichung, Taiwan
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| EASYWELL TANK-11MW | ||||||
| EASYWELL TANK-14MW | ||||||
| EASYWELL TANK-20MW | ||||||
| EASYWELL TANK-2MW | ||||||
| EASYWELL TANK-32MW | ||||||
| EASYWELL TANK-4ML | ||||||
| EASYWELL TANK-4MW | ||||||
| MTPA-3-10 | ||||||
| RO-105 | ||||||
| RO-1070 | ||||||
| RO-120 | ||||||
| RO-122 | ||||||
| RO-122P | ||||||
| RO-132 | ||||||
| RO-145 | ||||||
| RO-145P | ||||||
| RO-152 | ||||||
| RO-200 | ||||||
| RO-2000 | ||||||
| RO-760 | ||||||
| S-0800 | ||||||
| S-1800 | ||||||
| TP-100 | ||||||
| TP-12P | ||||||
| TP-130 | ||||||
| TP-150 | ||||||
| TP-16P | ||||||
| TP-19P | ||||||
| TP-20H | ||||||
| TP-24P | ||||||
| TP-3 | ||||||
| TP-35 | ||||||
| TP-4 | ||||||
| TP-4H | ||||||
|
  [1] Conforms to the material and structural integrity requirements. |
||||||
| The LeverEdge | |
| 1423 Gunn Highway | |
| Odessa, FL 33556-5304 | |
| United States | |
| 813-403-5100 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] [Pb] |
||||||
| AvantaPure RO-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Lead Reduction |
|||
| MAYTAG DRINKING WATER SYSTEM MODEL M-550 | S1340RSX-LEM | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| Pro Elite RO-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| Pro Elite RO-450 With Monitor | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| Westinghouse Drinking Water System A-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| Westinghouse Drinking Water System D-550 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
| Westinghouse Drinking Water System P-550 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction TDS Reduction Selenium Reduction |
|||
| Westinghouse Drinking Water System R-450 | S1340RSX-LE[2] | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] As of 05/28/2004.
[2] S1340RSX-LE consists of a S1340RS, a sump and an o-ring.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Toray Advanced Materials Korea Inc. | |
| 6F, 7, Magokdong-ro 10-gil | |
| Gangseo-gu, Seoul 07790 | |
| Korea, Republic of | |
| 82 23 279 7359 | |
| Visit this company's website |
Facility : Chungcheongnam-do, Republic of Korea
|
COMPONENTS: Membrane Elements[1] |
||||||
| NE2008-20 | ||||||
| NE2008-20 AS | ||||||
| NE2010-50 | ||||||
| NE2010-50 AS | ||||||
| RE1506-35 | ||||||
| RE1810-80 | ||||||
| RE1810-80 UTS | ||||||
| RE1812-110 | ||||||
| RE1812-50 | ||||||
| RE1812-80 | ||||||
| RE2008-20 | ||||||
| RE2008-20(M) | ||||||
| RE2008-30B | ||||||
| RE2010-30 | ||||||
| RE2010-30 UTS | ||||||
| RE2012-40 | ||||||
|
  [1] Conforms to material requirements only. |
||||||
Facility : Gyeongsangbuk-do, Republic of Korea
|
COMPONENTS: Membrane Elements[1] |
||||||
| RE-1508-35[2] | ||||||
| RE-1508-CE35 | ||||||
| RE-1609-50[2] | ||||||
| RE-1808-42[2] [3] | ||||||
| RE-1808-42(G) | ||||||
| RE-1808-50[2] | ||||||
| RE-1810-25[2] | ||||||
| RE-1810-36[2] | ||||||
| RE-1810-50[2] | ||||||
| RE-1811-50[2] | ||||||
| RE-1811-80[2] | ||||||
| RE-1812-24[2] | ||||||
| RE-1812-25[2] | ||||||
| RE-1812-35[2] | ||||||
| RE-1812-36[2] | ||||||
| RE-1812-50[2] | ||||||
| RE-1812-60[2] | ||||||
| RE-1812-80[2] | ||||||
| RE-1812-CE50 | ||||||
| RE-2010-30 | ||||||
| RE-2011-100 | ||||||
| RE-2011-LP | ||||||
| RE-2012-50 | ||||||
| RE-2012-70 | ||||||
| RE1812-110[2] | ||||||
| RE1812-HR+[3] | ||||||
| RE2012-100 | ||||||
| RE2012-150 | ||||||
| RE2012-400 | ||||||
| RE2012-CE | ||||||
| RE2012-HR+ | ||||||
| RE2012-LP | ||||||
| RE2012-LPF | ||||||
| RE2812-300 | ||||||
| RE3512-600 | ||||||
| RE3512-TK | ||||||
| UE-1810 | ||||||
| UE-2010 | ||||||
|
  [1] Conforms to material requirements only.
[2] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
Selenium and TDS. The test data results may be transferred to other manufacturer's
systems, if the systems meet the requirements contained in the document entitled
"Transfer of Performance Claims for Toray Chemical Korea Reverse Osmosis Elements”.
This document is available from Toray Chemical Korea Inc. (Formerly Woongjin Chemical
Co., Ltd.)
[3] Associated with a data transfer protocol. See manufacturer for more information.
|
||||||
| Toray Membrane USA, Inc. | |
| 13435 Danielson Street | |
| Poway, CA 92064 | |
| United States | |
| 714-678-8832 | |
| Visit this company's website |
Facility : Poway, CA
|
COMPONENTS: Membrane Elements[1] |
||||||
| RE1811-100[2] | ||||||
| RE1811-35[2] | ||||||
| RE1811-75[2] | ||||||
| RE1812-24[2] | ||||||
| RE1812-35[2] | ||||||
| RE1812-50[2] | ||||||
| RE1812-80[2] | ||||||
| RE1812-R150[3] [Pb] | ||||||
| RE2012-100 | ||||||
| RE2012-LP | ||||||
| RE2012-LPF | ||||||
|
  [1] Conforms to material requirements only. Membrane requires a 24-hour flushing and
conditioning procedure.
[2] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
Selenium and TDS. The test data results may be transferred to other manufacturer's
systems, if the systems meet the requirements contained in the document entitled
"Transfer of Performance Claims for Toray Chemical Korea Reverse Osmosis Elements."
This document is available from Toray Membrane USA.
[3] Requires 30 minutes flushing with tap water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| United Tanks LLC | |
| 75 Main Street | |
| Suite #1097 | |
| Norwalk, CT 06851 | |
| United States | |
| 888 893 1346 | |
| Visit this company's website |
Facility : # 1 United Tanks
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| M-02 | ||||||
| M-03 | ||||||
| M-04 | ||||||
| M-05 | ||||||
| S-03 | ||||||
| S-04 | ||||||
| S-05 | ||||||
| S-28 | ||||||
| S-40 | ||||||
|
  [1] Conforms to the material and structural integrity requirements. |
||||||
| Veluda | |
| Ifigenias 24 G | |
| Nicosia, Strovolos 2007 | |
| Cyprus | |
| 357 22572555 | |
| Visit this company's website |
Facility : # 3 China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Component: RO membrane[1] [2] |
||||||
| PREMIUM GRAY RO-1812-50 | ||||||
| PREMIUM GRAY RO-1812-75 | ||||||
| PREMIUM GRAY RO-2012-100 | ||||||
| PREMIUM GRAY RO-2812-200 | ||||||
| PURE RO-1812-50 | ||||||
| PURE RO-1812-75 | ||||||
| PURE RO-2012-100 | ||||||
| PURE RO-2812-200 | ||||||
| VELUDA RO-1812-50 | ||||||
| VELUDA RO-1812-75 | ||||||
| VELUDA RO-2012-100 | ||||||
| VELUDA RO-2812-200 | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, pH
value 3 ~ 8, flushing at least 48 hours.
[2] TF-XXYY-ZZ
XX - Membrane element diameter in inches
18 - 1.8"
20 - 2.0"
28 - 2.8"
YY - Membrane element length in inches (12")
ZZ - Permeated flow in gallons per day (GPD) (50, 75, 100, 200)
|
||||||
| Villarreal División Equipos SA de CV | |
| Morelos 905 Sur Centro | |
| Allende, NLE 67350 | |
| México | |
| 826-268-0800 | |
| Visit this company's website |
Facility : # 3 China
|
COMPONENTS: RO Membrane[1] [2] |
||||||
| PKRO-1812-50 | ||||||
| PKRO-1812-75 | ||||||
| PKRO-2012-100 | ||||||
| PKRO-2812-200 | ||||||
| PKRO-3012-400 | ||||||
|
  [1] Certified to Standard 58, material requirements only. At temperatures below 45°C, PH
value 3 ~ 8, flushing at least 48 hours.
[2] RO-XXYY-ZZ
XX - Membrane element diameter in inches
18" - 1.8"
20" - 2.0"
28" - 2.8"
30" - 3.0"
YY - Membrane element length in inches (12")
ZZ - Permeated flow in gallons per day (GPD)(50, 75, 100, 200 or 400)
|
||||||
| Vontron Membrane Technology Co., Ltd. | |
| No.1518, Liyang Road, Guiyang National | ![]() |
| High-Tech Industrial Development Zone | |
| Guiyang, Guizhou | |
| China | |
| 86 851 8627 0379 |
Facility : Guizhou, China
|
COMPONENTS: Membrane Elements[1] [2] |
||||||
| HOR2012 | ||||||
| ULP1609-50F | ||||||
| ULP1609-50P | ||||||
| ULP1809-100Q | ||||||
| ULP1809-50P | ||||||
| ULP1809-50Q | ||||||
| ULP1810-40 | ||||||
| ULP1810-50 | ||||||
| ULP1810-50P | ||||||
| ULP1810-50Q | ||||||
| ULP1810-70 | ||||||
| ULP1812-24 | ||||||
| ULP1812-36 | ||||||
| ULP1812-50 | ||||||
| ULP1812-75 | ||||||
| ULP2008-50P | ||||||
| ULP2010-100Q | ||||||
| ULP2010-80 | ||||||
| ULP2012-100 | ||||||
| ULP2012-125 | ||||||
| ULP2012-150 | ||||||
| ULP2809-200 | ||||||
| ULP2812 | ||||||
| ULP3012 | ||||||
| ULP3013-400 | ||||||
| ULP3020 | ||||||
| VNF-1812 | ||||||
| VNF-2012 | ||||||
| VNF-2812 | ||||||
| XLP2012-50 | ||||||
|
  [1] Certified to Standard 58, material requirements only. Membranes require a 24-hour
flushing before use.
[2] ULP/HOR/XLP/VNFXXYY-ZZ-P/Q/F
ULP/HOR/XLP/VNF - Type of membrane sheet
ULP - Regular ultra-low pressure residential element
HOR - High-oxidation-resistant residential element
XLP - extremely low pressure
VNF - Nanofiltration Membrane
XX - Membrane element diameter in inches
16 - 1.6"
18 - 1.8"
20 - 2.0"
28 - 2.8"
30 - 3.0"
YY - Membrane element length in inches (8",9",10", 12",13", 20")
ZZ - Permeated flow in gallons per day (GPD) (24, 36, 50, 70, 75, 80, 100, 125, 150
or 200)
P - The center tube is even to the membrane
Q - Provide special customer, for customer identification
F - The brine seal and the feed water direction in these models are opposite in
general model
|
||||||
| Water-Right / WaterCare | |
| 1900 Prospect Court | |
| Appleton, WI 54914 | |
| United States | |
| 920-739-9401 |
Facility : # 1 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| UltroWater[1] [2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
| Water-Right® WRO-35[1] [2] | S1448RS | 12 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Copper Reduction Fluoride Reduction Chromium (Hexavalent) Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Chromium (Trivalent) Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Serial number of 180000 or higher.
[2] As of 05/28/2004.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Waterena Company | |
| Industrial & Building Construction Area | |
| Sudair City | |
| Riyadh 15312 | |
| Saudi Arabia | |
| 966 114477777 | |
| Visit this company's website |
Facility : Ningbo, Zhejiang, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| WS1812-100 | ||||||
| WS1812-50 | ||||||
| WS1812-75 | ||||||
| WS2812-200 | ||||||
| WS3012-300 | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 48 hour flushing procedure. |
||||||
| Waterena Factory for Water Pumps | |
| P.O. Box 4784 | |
| Sudair City | |
| Riyadh, 11412 | |
| Saudi Arabia | |
| 966 11 447 7777 |
Facility : Riyadh, Saudi Arabia
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap |
||||||
| WATERENA RO-WSDB3-75S | 7003479 | 75 | TDS Reduction | |||
| WATERENA RO-WSP1-75T | 7003479 | 75 | TDS Reduction | |||
| WATERENA RO-WSSY2-75S | 7003479 | 75 | TDS Reduction | |||
| Watts Water Quality & Conditioning Products | |
| 13700 Highway 90 West | |
| San Antonio, TX 78245 | |
| United States | |
| 800-659-8400 |
Facility : # 1 China
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| RO-PRO | ||||||
|
  [1] Conforms to the materials and structural integrity requirements only. |
||||||
| Watts Water Quality & Conditioning Products | |
| 11611 Southeast 147 Court | |
| Dunnellon, FL 34432 | |
| United States | |
| 800-46-4406 | |
| 352-465-2000 |
Facility : # 1 USA
|
COMPONENTS: Membranes[1] [2] |
||||||
| W-1812-100 | ||||||
| W-1812-24 | ||||||
| W-1812-36 | ||||||
| W-1812-50 | ||||||
| W-1812-75 | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 24 hour flushing procedure.
[2] These elements have been tested for the reduction of Pentavalent Arsenic, Barium,
Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead,
Radium 226/228, and Selenium.
|
||||||
| WelWater Filtration Technologies (SuZhou) Co., Ltd. | |
| Unit 14B, Suchun Industrial Square | |
| 428 Xinglong Street, SIP | |
| Suzhou, Jiangsu 215021 | |
| China | |
| 86-512-69998188 | |
| Visit this company's website |
Facility : Suzhou, China
|
COMPONENTS: Polypropylene (PP)[1] [2] [3] |
||||||
| RO Spacer - WX | ||||||
|
  [1] Conforms to material requirements only. [2] Certified for a maximum use level of 4040 cm²/L. [3] X - Thickness (0.013”-0.080”) |
||||||
| Whirlpool Corporation | |
| 2000 North M-63 | |
| Benton Harbor, MI 49022 | |
| United States | |
| 269-923-6000 |
Facility : # 1 Taiwan
|
COMPONENTS: Membrane Elements[1] |
||||||
| WHKF-WHERPMK | ||||||
|
  [1] Conforms to the material requirements only. |
||||||
| Zhejiang Guangyue Environmental Technology Co., Ltd. | |
| No.27 Beiyuan Road, West Industrial Zone | |
| North City, Huangyan | |
| Taizhou, Zhejiang 318020 | |
| China | |
| 86 576 84113809 | |
| Visit this company's website |
Facility : Taizhou, Zhejiang, China
|
COMPONENTS: Storage Tanks, Low Pressure[1] |
||||||
| HYRO-1.0 | ||||||
| HYRO-2.0 | ||||||
| HYRO-3.0 | ||||||
| HYRO-4.0 | ||||||
|
  [1] Conforms to material and structural integrity. |
||||||
| Zhejiang Jeffel Environmental Science and Technology Co., Ltd. | |
| North Century Avenue of Chongfu | |
| Tongxiang 314511 | |
| China | |
| 86 15024379212CELL | |
| Visit this company's website |
Facility : Zhejiang, China
|
COMPONENTS: Membrane Elements[1] |
||||||
| JF-RO12 | ||||||
|
  [1] Conforms to material requirements only. Membranes require a 24 hours flushing before
use.
|
||||||
Number of matching Manufacturers is 128
Number of matching Products is 1168
Processing time was 1 seconds













