NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects
Drinking Water Treatment Units - Aesthetic Effects
Access Business Group International LLC, DBA Amway | |
7575 Fulton Street East | |
Ada, MI 49355 | |
United States | |
1-800-253-6500 | |
Visit this company's website |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Counter-Top Connected to Sink Faucet |
||||||
eSpring Model 100185 (100188K) | 100186K | 1320(1) | .9 | Chloramine Reduction Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Plumbed-In to Separate Tap |
||||||
eSpring Model 100185 (100189K) | 100186K | 1320(1) | .9 | Chloramine Reduction Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
eSpring Model 100185 (100189TH) | 100186K | 1320(1) | .9 | Chloramine Reduction Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Replacement Element: Plumbed-In |
||||||
100186K | N/A | 1320(1) | .9 | Chloramine Reduction Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
NSF/ANSI 53
Drinking Water Treatment Units - Health Effects
Drinking Water Treatment Units - Health Effects
Access Business Group International LLC, DBA Amway | |
7575 Fulton Street East | |
Ada, MI 49355 | |
United States | |
1-800-253-6500 | |
Visit this company's website |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Counter-Top Connected to Sink Faucet |
||||||
eSpring Model 100185 (100188K)[3] | 100186K | 1320(1) | .9 | Asbestos Reduction Chlordane Reduction Lead Reduction MTBE Reduction Mercury Reduction Microcystin Reduction Radon Reduction Toxaphene Reduction VOC Reduction ** PFOA Reduction PFOS Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53. [3] PFOA/PFOS reduction claim evaluated to the 2022 version of NSF/ANSI Standard 53. [4] Total PFAS includes perfluoroheptanoic (PFHpA), perfluorohexane sulfonic acid (PFHxS), perfluorononanoic acid (PFNA), perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), perfluorobutanesulfonic acid (PFBS), perfluorodecanoic acid (PFDA) [7] Total PFAS includes perfluoroheptanoic (PFHpA), perfluorohexane sulfonic acid (PFHxS), perfluorononanoic acid (PFNA), perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), perfluorobutanesulfonic acid (PFBS), perfluorodecanoic acid (PFDA) [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Plumbed-In to Separate Tap |
||||||
100186K[3] | N/A | 1320(1) | .9 | Asbestos Reduction Chlordane Reduction Lead Reduction MTBE Reduction Mercury Reduction Microcystin Reduction Radon Reduction Toxaphene Reduction VOC Reduction ** PFOA Reduction PFOS Reduction |
||
eSpring Model 100185 (100189K)[3] | 100186K | 1320(1) | .9 | Asbestos Reduction Chlordane Reduction Lead Reduction MTBE Reduction Mercury Reduction Microcystin Reduction Radon Reduction Toxaphene Reduction VOC Reduction ** PFOA Reduction PFOS Reduction |
||
eSpring Model 100185 (100189TH)[3] | 100186K | 1320(1) | .9 | Asbestos Reduction Chlordane Reduction Lead Reduction MTBE Reduction Mercury Reduction Microcystin Reduction Radon Reduction Toxaphene Reduction VOC Reduction ** PFOA Reduction PFOS Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53. [3] PFOA/PFOS reduction claim evaluated to the 2022 version of NSF/ANSI Standard 53. [4] Total PFAS includes perfluoroheptanoic (PFHpA), perfluorohexane sulfonic acid (PFHxS), perfluorononanoic acid (PFNA), perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), perfluorobutanesulfonic acid (PFBS), perfluorodecanoic acid (PFDA) [7] Total PFAS includes perfluoroheptanoic (PFHpA), perfluorohexane sulfonic acid (PFHxS), perfluorononanoic acid (PFNA), perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), perfluorobutanesulfonic acid (PFBS), perfluorodecanoic acid (PFDA) [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
NSF/ANSI 55
Ultraviolet Microbiological Water Treatment Systems
Ultraviolet Microbiological Water Treatment Systems
Access Business Group International LLC, DBA Amway | |
7575 Fulton Street East | |
Ada, MI 49355 | |
United States | |
1-800-253-6500 | |
Visit this company's website |
Facility : # 1 China
Replacement | Flow Rate | |||||
Brand Name / Trade Name / Model | Bulb | (gpm) | Claim | |||
Counter-Top Connected to Sink Faucet |
||||||
eSpring Model 100185 (100188K) | 100186K | .9 | Disinfection Performance, Class B | |||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Plumbed-In to Separate Tap |
||||||
100186K | N/A | .9 | Disinfection Performance, Class B | |||
eSpring Model 100185 (100189K) | 100186K | .9 | Disinfection Performance, Class B | |||
eSpring Model 100185 (100189TH) | 100186K | .9 | Disinfection Performance, Class B | |||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
Access Business Group International LLC, DBA Amway | |
7575 Fulton Street East | |
Ada, MI 49355 | |
United States | |
1-800-253-6500 | |
Visit this company's website |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Counter-Top Connected to Sink Faucet |
||||||
eSpring Model 100185 (100188K) | 100186K | 1320 | .9 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Plumbed-In to Separate Tap |
||||||
100186K | N/A | 1320 | .9 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
eSpring Model 100185 (100189K) | 100186K | 1320 | .9 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
eSpring Model 100185 (100189TH) | 100186K | 1320 | .9 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |