NSF Product and Service Listings

These NSF Official Listings are current as of Tuesday, June 10, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?TradeName=3M&hdModlStd=ModlStd&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects


 
Access Business Group International LLC, DBA Amway 
7575 Fulton Street East
Ada, MI 49355 
United States 
1-800-253-6500
Visit this company's website

Facility : # 1 China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Counter-Top Connected to Sink Faucet
eSpring 122940M[Pb] 122943M 1320 .7   Chlorine Reduction
Chloramine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
eSpring 122940SG[Pb] 122943M 1320 .7   Chlorine Reduction
Chloramine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Calgon Carbon Corporation 
3000 GSK Drive
Moon Township, PA 15108 
United States 
800-422-7266 
412-787-6762
Visit this company's website

Facility : # 2 Huntington, WV

 
           

COMPONENTS: Media, Carbon, Point-of-Use [1]
PGW 100MD 3M[2] [3]  
PGW 100MP 3M[2] [3]  
PGW 120MP 3M[2] [3]  
PGW 150MP 3M[2] [3]  
PGW 20MD 3M[2] [3]  
PGW 20MP 3M[2] [3]  
PGWH 150MP 3M[2] [3]  
PGWH 60X150 3M[2] [3]  

   
[1] Trade names MAY include letters and / or numbers to designate any or all of the
    following:
    mesh size, customer, market, processing methods, intended application, activity level,
    special testing or other customer or product specific differentiators.
[1] Trade names MAY include letters and / or numbers to designate any or all of the
    following:
    mesh size, customer, market, processing methods, intended application, activity level,
    special testing or other customer or product specific differentiators.
[2] The carbon source is coconut shell.
[3] Certified for mesh sizes < 325.
[4] The carbon source is coal.


Facility : Columbus, OH

 
           

COMPONENTS: Media, Carbon, Point-of-Use
PGW 100MD 3M[3] [4]  
PGW 100MP 3M[3] [4]  
PGW 120MP 3M[3] [4]  
PGW 150MP 3M[3] [4]  
PGW 20MD 3M[3] [4]  
PGW 20MP 3M[3] [4]  
PGWH 150MP 3M[3] [4]  
PGWH 60X150 3M[3] [4]  

   
[1] Trade names MAY include letters and / or numbers to designate any or all of the
    following:
    mesh size, customer, market, processing methods, intended application, activity level,
    special testing or other customer or product specific differentiators.
[2] The carbon source is coal.
[3] The carbon source is coconut shell.
[4] Certified for mesh sizes < 325.

NOTE: These components do not bear the NSF Mark.  Evidence of Certification will appear on the
      manufacturer's literature and packaging.


 
Solventum Purification Inc. 
400 Research Parkway
Meriden, CT 06450 
United States 
800-222-7880 
651 737 1374
Visit this company's website

Facility : Stafford Springs, CT

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
3MRO501[G] 3MROP411
3MROP412
3MROM413
3MROP416
1500(1) .5   Chlorine Reduction
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

COMPONENTS: Filter Cartridges
3MPF101[1]  

   
[1] Conforms to material requirements only.


Facility : New Ulm, MN

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW201 3MDW211 6000(1) 2.5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
3MDW301[G] 3MDW311 1000(1) .75   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Chloramine Reduction
3MFF100 3MFF101 6000(1) 2.5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
3MPF201 3MPF211 (1) 10   Nominal Particulate Reduction, Class IV
3MPF301 3MPF311HD (1) 10   Nominal Particulate Reduction, Class III

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Available with the VH3 series heads (as molded, with plug or with gauge).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Plumbed-In to Separate Tap
3MDW301-F 3MDW311 1000(1) .75   Chloramine Reduction
Chlorine Reduction
Taste and Odor Reduction
Nominal Particulate Reduction, Class I

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.


Facility : Nuevo Leon, Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW001 3MDW011
3CT-F031-5
3US-F011-5
2000(1) 1   Chlorine Reduction
Taste and Odor Reduction
Nominal Particulate Reduction, Class I
3MDW101 3MDW111 500(1) .75   Chlorine Reduction
Taste and Odor Reduction
Nominal Particulate Reduction, Class I

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Plumbed-In to Separate Tap
3MRO301[4] 3MROP310
3MROP416
3MROM413
1500 .5   Chlorine Reduction
Taste and Odor Reduction
3MRO401[4] 3MROP411
3MROP412
3MROM413
3MROP416
1500 .5   Chlorine Reduction
Taste and Odor Reduction

   
[4] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

COMPONENTS: Filter Cartridges
3MPF117[11]  

   
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[11] Conforms to material requirements only.
[12] Up to 40" in length.
[13] Conforms to the material and structural integrity requirements only.
[14] LC  - Length 
           09 – 9" - 3/4" nominal
           10 – 10" nominal 
           19 – 19" - 1/2" nominal
           20 – 20" nominal
           29 – 29" - 1/4" nominal
           30 – 30" nominal
           39 – 39" nominal
           40 - 40" nominal
           49 – 49" nominal
           50 – 50" nominal
           59 – 59" nominal
           60 – 60" nominal
           62 – 62" nominal 
     GC  - Micron rating 
           B – 5 micron
           C – 10 micron
           F – 25 micron
           L – 50 micron
           Q – 75 micron
           Y – 1 micron 
     X   - Surface 
           G – Grooved
           U – Ungrooved 
     Y  - Package option 
           2 – Bulk/polybag
           3 – Polybag & labeled (Worldwide)
           4 – Polybag & labeled (Latina)
           5 – Bulk/No polybag 
     Z  -  Ring support option 
           0 – None
           1 – Polysulfone
           2 – Stainless Steel 
     EMC - End treatment
           B – 226 O-ring & spear
           C – 222 O-ring & spear
           F – 222 O-ring & flat cap
           N – None
           P – P-core extender 
     OC  - O-ring material   
           A – Silicone
           B – Fluorocarbon
           C – EPR
           D – Nitrile
           G – Polyethylene
           N - None

COMPONENTS: Filter Housings
3MPF101[13]  

   
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[13] Conforms to the material and structural integrity requirements only.


NSF/ANSI 53
Drinking Water Treatment Units - Health Effects



 
Access Business Group International LLC, DBA Amway 
7575 Fulton Street East
Ada, MI 49355 
United States 
1-800-253-6500
Visit this company's website

Facility : # 1 China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Counter-Top Connected to Sink Faucet
eSpring 122940M[2] [4] 122943M 1320(1) .7   1,2,3-Trichloropropane
Asbestos Reduction
Chlordane Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
Microcystin Reduction
Radon Reduction
Toxaphene Reduction
VOC Reduction **
PFOA Reduction
PFOS Reduction
Total PFAS Reduction
eSpring 122940SG[2] [4] 122943M 1320(1) .7   1,2,3-Trichloropropane
Asbestos Reduction
Chlordane Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
Microcystin Reduction
Radon Reduction
Toxaphene Reduction
VOC Reduction **
PFOA Reduction
PFOS Reduction
Total PFAS Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[3] PFOA/PFOS reduction claim evaluated to the 2022 version of NSF/ANSI Standard 53.
[4] Total PFAS includes perfluoroheptanoic (PFHpA), perfluorohexane sulfonic acid (PFHxS),
    perfluorononanoic acid (PFNA), perfluorooctanoic acid (PFOA) and perfluorooctane
    sulfonate (PFOS), perfluorobutanesulfonic acid (PFBS), perfluorodecanoic acid (PFDA) 
[7] Total PFAS includes perfluoroheptanoic (PFHpA), perfluorohexane sulfonic acid (PFHxS),
    perfluorononanoic acid (PFNA), perfluorooctanoic acid (PFOA) and perfluorooctane
    sulfonate (PFOS), perfluorobutanesulfonic acid (PFBS), perfluorodecanoic acid (PFDA)
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                


 
Solventum Purification Inc. 
400 Research Parkway
Meriden, CT 06450 
United States 
800-222-7880 
651 737 1374
Visit this company's website

Facility : New Ulm, MN

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW201 3MDW211 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
3MDW301[G] 3MDW311 1000(1) .75   1,2,3-Trichloropropane
Asbestos Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Trihalomethanes (TTHM) Reduction
VOC Reduction **
3MFF100 3MFF101 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[5] Available with the VH3 series heads (as molded, with plug or with gauge).
[7] System uses 2 HF60-CL cartridges.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Plumbed-In to Separate Tap
3MDW301-F 3MDW311 1000(1) .75   Cyst Reduction
Lead Reduction
VOC Reduction **
Asbestos Reduction
1,2,3-Trichloropropane
Trihalomethanes (TTHM) Reduction
MTBE Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Nuevo Leon, Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW001 3MDW011
3CT-F031-5
3US-F011-5
2000(1) 1   Cyst Reduction
Turbidity Reduction
3MDW101 3MDW111 500(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

NSF/ANSI 55
Ultraviolet Microbiological Water Treatment Systems



 
Access Business Group International LLC, DBA Amway 
7575 Fulton Street East
Ada, MI 49355 
United States 
1-800-253-6500
Visit this company's website

Facility : # 1 China

  Replacement   Flow Rate  
Brand Name / Trade Name / Model Bulb   (gpm)   Claim

Counter-Top Connected to Sink Faucet
eSpring 122940M 122943M   .7   Disinfection Performance, Class B
eSpring 122940SG 122943M   .7   Disinfection Performance, Class B

   
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Applied Membranes, Inc. 
2450 Business Park Drive
Vista, CA 92081-8847 
United States 
800-321-9321 
760-727-3711 X125

Facility : Guelph, Ontario, Canada

  Replacement   Flow Rate  
Brand Name / Trade Name / Model Bulb   (gpm)   Claim

Point-of-Entry
UV-SPNSFA-6.3M UV-SPH-11-L   6.3   Disinfection Performance, Class A
UV-SPNSFA-6.3M-AU UV-SPH-11-L   6.3   Disinfection Performance, Class A
UV-SPNSFA-6.3M-EU UV-SPH-11-L   6.3   Disinfection Performance, Class A
UV-SPNSFA-6.3M-UK UV-SPH-11-L   6.3   Disinfection Performance, Class A
UV-SPNSFB-13M UV-SPH-11-L   13   Disinfection Performance, Class B
UV-SPNSFB-13M-AU UV-SPH-11-L   13   Disinfection Performance, Class B
UV-SPNSFB-13M-EU UV-SPH-11-L   13   Disinfection Performance, Class B
UV-SPNSFB-13M-HP UV-SPH-15-HPL   13   Disinfection Performance, Class B
UV-SPNSFB-13M-HP-AU UV-SPH-15-HPL   13   Disinfection Performance, Class B
UV-SPNSFB-13M-HP-EU UV-SPH-15-HPL   13   Disinfection Performance, Class B
UV-SPNSFB-13M-HP-UK UV-SPH-15-HPL   13   Disinfection Performance, Class B
UV-SPNSFB-13M-UK UV-SPH-11-L   13   Disinfection Performance, Class B


NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



 
Solventum Purification Inc. 
400 Research Parkway
Meriden, CT 06450 
United States 
800-222-7880 
651 737 1374
Visit this company's website

Facility : Stafford Springs, CT

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Replacement Element: Plumbed-In to Separate Tap
3MRO501[G] 3MROP411
3MROP412
3MROM413
3MROP416
  23.92   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Nitrate/Nitrite Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Facility : Nuevo Leon, Mexico

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
3MRO301 3MROP310
3MROP416
3MROM413
  11.48   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
3MRO401 3MROP411
3MROP412
3MROM413
3MROP416
  11.48   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Fluoride Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants



 
Access Business Group International LLC, DBA Amway 
7575 Fulton Street East
Ada, MI 49355 
United States 
1-800-253-6500
Visit this company's website

Facility : # 1 China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Counter-Top Connected to Sink Faucet
eSpring 122940M 122943M 1320(1) .7   Atenolol Reduction
Bisphenol A Reduction
Carbamazepine Reduction
DEET Reduction
Estrone Reduction
Ibuprofen Reduction
Linuron Reduction
Meprobamate Reduction
Metolachlor Reduction
Naproxen Reduction
Nonylphenol Reduction
Phenytoin Reduction
TCEP Reduction
TCPP Reduction
Trimethoprim Reduction
Microplastics Reduction
eSpring 122940SG 122943M 1320(1) .7   Atenolol Reduction
Bisphenol A Reduction
Carbamazepine Reduction
DEET Reduction
Estrone Reduction
Ibuprofen Reduction
Linuron Reduction
Meprobamate Reduction
Metolachlor Reduction
Naproxen Reduction
Nonylphenol Reduction
Phenytoin Reduction
TCEP Reduction
TCPP Reduction
Trimethoprim Reduction
Microplastics Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Solventum Purification Inc. 
400 Research Parkway
Meriden, CT 06450 
United States 
800-222-7880 
651 737 1374
Visit this company's website

Facility : New Ulm, MN

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
3MDW201 3MDW211 (1) 2.5   Microplastics Reduction
3MDW301[G] 3MDW311 1000(1) .75   Atenolol Reduction
Bisphenol A Reduction
Carbamazepine Reduction
DEET Reduction
Estrone Reduction
Linuron Reduction
Naproxen Reduction
Nonylphenol Reduction
Phenytoin Reduction
Trimethoprim Reduction
Ibuprofen Reduction
Meprobamate Reduction
Metolachlor Reduction
Microplastics Reduction
3MFF100 3MFF101 (1) 2.5   Microplastics Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plumbed-In to Separate Tap
3MDW301-F 3MDW311 1000(1) .75   Bisphenol A Reduction
Estrone Reduction
Ibuprofen Reduction
Naproxen Reduction
Nonylphenol Reduction
Phenytoin Reduction
Meprobamate Reduction
Microplastics Reduction
Atenolol Reduction
Carbamazepine Reduction
DEET Reduction
Metolachlor Reduction
Trimethoprim Reduction
Linuron Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.

[6] Available options: 
        (1) 2.1
        (2) 1.7
        (3) 1.0
[17] CS-511, CS-711

Facility : Nuevo Leon, Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW001 3CT-F031-5
3MDW011
3US-F011-5
(1) 1   Microplastics Reduction
3MDW101 3MDW111 (1) .75   Microplastics Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


CSA Standard B483.1
Drinking Water Treatment Systems



 
Solventum Purification Inc. 
400 Research Parkway
Meriden, CT 06450 
United States 
800-222-7880 
651 737 1374
Visit this company's website

Facility : Stafford Springs, CT

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
3MRO501 3MROP411
3MROP412
3MROM413
3MROP416
1500(1) .5   Chlorine Reduction
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.

[2] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.

Facility : New Ulm, MN

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW301[G] 3MDW311 1000(1) .75   Chloramine Reduction
Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
3MFF100[2] 3MFF100 6000(1) 2.5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Available with the VH3 series heads (as molded, with plug or with gauge).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Plumbed-In to Separate Tap
3MDW301-F 3MDW311 1000(1) .75   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Chloramine Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.

NOTE: All replacement elements are components.

Facility : Nuevo Leon, Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
3MRO301[4] 3MROM413
3MROP310
3MROP416
1500 .5   Chlorine Reduction
Taste and Odor Reduction
3MRO401[4] 3MROM413
3MROP411
3MROP412
3MROP416
1500(1) .5   Chlorine Reduction
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[4] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Facility : New Ulm, MN

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW301[G] 3MDW311 1000(1) .75   1,2,3-Trichloropropane
Asbestos Reduction
Atenolol Reduction
Bisphenol A Reduction
Carbamazepine Reduction
Cyst Reduction
DEET Reduction
Estrone Reduction
Ibuprofen Reduction
Lead Reduction
Linuron Reduction
Meprobamate Reduction
Metolachlor Reduction
Microplastics Reduction
MTBE Reduction
Naproxen Reduction
Nonylphenol Reduction
Phenytoin Reduction
Trihalomethanes (TTHM) Reduction
Trimethoprim Reduction
VOC Reduction **
3MFF100[2] 3MFF100 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Available with the VH3 series heads (as molded, with plug or with gauge).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Plumbed-In to Separate Tap
3MDW301-F 3MDW311 1000(1) .75   Cyst Reduction
Lead Reduction
MTBE Reduction
VOC Reduction **
Asbestos Reduction
Trihalomethanes (TTHM) Reduction
1,2,3-Trichloropropane
Bisphenol A Reduction
Estrone Reduction
Ibuprofen Reduction
Naproxen Reduction
Nonylphenol Reduction
Phenytoin Reduction
Meprobamate Reduction
Atenolol Reduction
Carbamazepine Reduction
DEET Reduction
Metolachlor Reduction
Microplastics Reduction
Trimethoprim Reduction
Linuron Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.

NOTE: All replacement elements are components.

** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Stafford Springs, CT

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Replacement Element: Plumbed-In to Separate Tap
3MRO501[G] 3MROP411
3MROP412
3MROM413
3MROP416
  23.92   Arsenic (Pentavalent)<=300 ppb Reduction
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Nitrate/Nitrite Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Nuevo Leon, Mexico

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
3MRO301 3MROP310
3MROP416
3MROM413
  11.48   Arsenic (Pentavalent)<=300 ppb Reduction
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
3MRO401 3MROP411
3MROP412
3MROM413
3MROP416
  11.48   Arsenic (Pentavalent)<=300 ppb Reduction
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Fluoride Reduction

   
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.

** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Number of matching Manufacturers is 11
Number of matching Products is 77
Processing time was 1 seconds