NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, October 30, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?TradeName=Pentair&hdModlStd=ModlStd&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects
Drinking Water Treatment Units - Aesthetic Effects
| Pentair Residential Filtration, LLC | |
| 13845 Bishops Drive | |
| Suite 200 | |
| Brookfield, WI 53005 | |
| United States | |
| 800-279-9404 | |
| 262-238-4400 |
Facility : Dover, NH
|
COMPONENTS: Filter Cartridges[3] |
||||||
| Pentair CBC-20BB | ||||||
| Pentair CBC-BB | ||||||
| Pentair CFB-Plus10 | ||||||
| Pentair CFB-Plus10BB | ||||||
| Pentair CFB-Plus20 | ||||||
| Pentair CFB-Plus20BB | ||||||
| Pentair CFB-Plus30 | ||||||
| Pentair ChlorPlus 10 | ||||||
| Pentair ChlorPlus 10BB[6] [Pb] | ||||||
| Pentair ChlorPlus 20 | ||||||
| Pentair ChlorPlus 20BB[6] [Pb] | ||||||
| Pentair EP-20BB | ||||||
| Pentair EP-BB | ||||||
| Pentair EPM-20BB | ||||||
| Pentair EPM-BB | ||||||
|
  [3] Conforms to material requirements only.
[6] From date code 4240-1.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
NOTE: These components do not bear the NSF Mark. Evidence of Certification will appear on the
manufacturer's literature and packaging.
Facility : Jiangsu Province, China
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In to Separate Tap |
||||||
| Pentair F1000-B1B[Pb] | F1B1-RC | 750(1) | .6 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
| Pentair F1000-DFB[Pb] | FDF1-RC | 750 | .75 | Chlorine Reduction Taste and Odor Reduction |
||
| Pentair F2000-B2B[Pb] | F2B2-RC2 | 675(1) | .6 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
| Pentair F3000-B2B[Pb] | F2B2-RC2 F1S5-RC |
675(1) | .6 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
| Pentair GRO-350B[2] [Pb] | FDF1-RC | 750 | .75 | Chlorine Reduction Taste and Odor Reduction |
||
| Pentair GRO-475B[2] [Pb] | FDF1-RC F1B1-RC |
750(1) | .6 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
| Pentair GRO-475BP[2] [Pb] | FDF1-RC F1B1-RC |
750(1) | .6 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
| Pentair GRO-575B[2] [Pb] | FDF1-RC F2B2-RC2 F2B1-RC |
675(1) | .6 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Model is a reverse osmosis system and is also Certified to NSF/ANSI 58.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Filter Cartridges[4] |
||||||
| Pentair C1 | ||||||
| Pentair CB1-10 | ||||||
| Pentair CBC-10 | ||||||
| Pentair CBC-20 | ||||||
| Pentair CBR2-10R | ||||||
| Pentair CC-10 | ||||||
| Pentair DFX-CB-10 | ||||||
| Pentair DGD-2501[Pb] | ||||||
| Pentair DGD-2501-20[Pb] | ||||||
| Pentair DGD-5005[Pb] | ||||||
| Pentair DGD-5005-20[Pb] | ||||||
| Pentair DGD-7525[Pb] | ||||||
| Pentair DGD-7525-20[Pb] | ||||||
| Pentair EP-10 | ||||||
| Pentair EP-20 | ||||||
| Pentair EPM-10 | ||||||
| Pentair EPM-20 | ||||||
| Pentair GAC-10 | ||||||
| Pentair GAC-20BB | ||||||
| Pentair P1 | ||||||
| Pentair P1-20 | ||||||
| Pentair P5 | ||||||
| Pentair P5-20 | ||||||
| Pentair PD-5-934 | ||||||
| Pentair RFC-BB | ||||||
| Pentair RFC20-BB | ||||||
| Pentair W.5CB | ||||||
| Pentair W5CIP | ||||||
| Pentair W5P | ||||||
| Pentair WDGD-5005[Pb] | ||||||
| Pentair WLC-R | ||||||
| Pentair WRC25HD | ||||||
| Pentair WRC25HD20[5] | ||||||
|
  [4] Conforms to material requirements only.
[5] Cartridge requires a 10 minute flush, a 1 hour hold, and a 10 minute flushing and
conditioning procedure.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Filter Housings[6] |
||||||
| Pentair 150233 | ||||||
| Pentair 150233WM | ||||||
| Pentair 150234 | ||||||
| Pentair 150237 | ||||||
| Pentair 150237WM | ||||||
| Pentair 150238 | ||||||
| Pentair 158005 | ||||||
| Pentair 158006 | ||||||
| Pentair 158114 | ||||||
| Pentair 158120 | ||||||
| Pentair 158125 | ||||||
| Pentair 158125WM | ||||||
| Pentair 158195 | ||||||
| Pentair 158195WM | ||||||
| Pentair 158196 | ||||||
| Pentair 158739 | ||||||
| Pentair 158739WM | ||||||
|
  [6] Conforms to material and structural integrity requirements only. |
||||||
[3] OmniFilter US2000.
Facility : Reynosa, Mexico
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In |
||||||
| Pentair GS-10ALS[2] | N/A | 1350 | 1 | Chlorine Reduction Taste and Odor Reduction |
||
| Pentair GS-10RO[2] | N/A | 3308 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Pentair LR-1500[Pb] | LR-FB10 | 1500 | 2.5 | Chlorine Reduction Taste and Odor Reduction |
||
|
  [2] From date code 5D10
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Filter Cartridges[3] |
||||||
| Pentair C1[4] | ||||||
| Pentair CRFC20-BB | ||||||
|
  [3] Conforms to material requirements only. [4] RY is used to identify Reynosa, Mexico facility. |
||||||
|
COMPONENTS: Filter Housings [8] |
||||||
| Pentair 150067 | ||||||
| Pentair 150068 | ||||||
| Pentair 150069 | ||||||
| Pentair 150071 | ||||||
| Pentair 150072 | ||||||
| Pentair 150164 | ||||||
| Pentair 150166 | ||||||
| Pentair 150235 | ||||||
| Pentair 150236 | ||||||
| Pentair 150239 | ||||||
| Pentair 150435 | ||||||
| Pentair 150437 | ||||||
| Pentair 150467 | ||||||
| Pentair 150468 | ||||||
| Pentair 150469 | ||||||
| Pentair 150470 | ||||||
| Pentair 153198[5] | ||||||
| Pentair 153200[6] | ||||||
| Pentair 154639[7] | ||||||
| Pentair 154654[7] | ||||||
| Pentair 154981[7] | ||||||
| Pentair 158205 | ||||||
| Pentair 158208 | ||||||
| Pentair R50067[Pb] | ||||||
| Pentair R50067-75[Pb] | ||||||
| Pentair R50068[Pb] | ||||||
| Pentair R50069[Pb] | ||||||
| Pentair R50070[Pb] | ||||||
| Pentair R50071-75[Pb] | ||||||
| Pentair R50072[Pb] | ||||||
| Pentair R52018[Pb] | ||||||
| Pentair R52047[Pb] | ||||||
| Pentair W10-PR | ||||||
| Pentair W15-PR | ||||||
| Pentair W2010-PR | ||||||
| Pentair W2015-PR | ||||||
| Pentair W38-PRB | ||||||
| Pentair WC34-PR | ||||||
| Pentair WVC34 | ||||||
|
  [5] 10" sump for use with any 3/4" cap
[6] 20" sump for use with any 3/4" cap
[7] 3/4" cap
[8] Conforms to material and structural integrity requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Filter Housings, Point-of-Entry[8] |
||||||
| Pentair 150233[Pb] | ||||||
| Pentair 150234[Pb] | ||||||
| Pentair 150237[Pb] | ||||||
| Pentair 150238[Pb] | ||||||
|
  [8] Conforms to material and structural integrity requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
NSF/ANSI 53
Drinking Water Treatment Units - Health Effects
Drinking Water Treatment Units - Health Effects
| Pentair Residential Filtration, LLC | |
| 13845 Bishops Drive | |
| Suite 200 | |
| Brookfield, WI 53005 | |
| United States | |
| 800-279-9404 | |
| 262-238-4400 |
Facility : Dover, NH
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Replacement Element: Plumbed-In |
||||||
| Pentair Floplus 10[6] [Pb] | N/A | (1) | 5 | Cyst Reduction | ||
| Pentair Floplus 10BB[7] [Pb] | N/A | (1) | 10 | Cyst Reduction | ||
| Pentair Floplus 20[8] [Pb] | N/A | (1) | 10 | Cyst Reduction | ||
| Pentair Floplus 20BB[9] [Pb] | N/A | (1) | 25 | Cyst Reduction | ||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Pentair LR-1500
[3] Pentair LR-BB50
[4] OmniFilter PB35
[5] OmniFilter PB55
[6] Pentair FPS-10
[7] Pentair FPS-10BB
[8] Pentair FPS-20
[9] Pentair FPS-20BB
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Facility : Jiangsu Province, China
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In to Separate Tap |
||||||
| Pentair F1000-B1B[Pb] | F1B1-RC | 750(1) | .6 | Atrazine Reduction Cyst Reduction Lead Reduction |
||
| Pentair F2000-B2B[Pb] | F2B2-RC2 | 675(1) | .6 | Atrazine Reduction Cyst Reduction Lead Reduction |
||
| Pentair F3000-B2B[Pb] | F2B2-RC2 F1S5-RC |
675(1) | .6 | Atrazine Reduction Cyst Reduction Lead Reduction |
||
| Pentair GRO-475B[1] [Pb] | FDF1-RC F1B1-RC |
750(1) | .6 | Atrazine Reduction Cyst Reduction Lead Reduction |
||
| Pentair GRO-475BP[1] [Pb] | FDF1-RC F1B1-RC |
750(1) | .6 | Atrazine Reduction Cyst Reduction Lead Reduction |
||
| Pentair GRO-575B[1] [Pb] | FDF1-RC F2B2-RC2 F2B1-RC |
675(1) | .6 | Atrazine Reduction Cyst Reduction Lead Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[1] Model is a reverse osmosis system and is also Certified to NSF/ANSI 58.
[3] ROR2000 is a replacement kit containing RS14, CB1, and two o-rings.
[4] ROR2050 is a replacement kit containing R200, CB1, RS14, and two o-rings.
[5] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Facility : Reynosa, Mexico
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In |
||||||
| Pentair FPS-10[Pb] | Floplus 10 | (1) | 5 | Cyst Reduction | ||
| Pentair FPS-10BB[Pb] | Floplus 10BB | (1) | 10 | Cyst Reduction | ||
| Pentair FPS-20[Pb] | Floplus 20 | (1) | 10 | Cyst Reduction | ||
| Pentair FPS-20BB[Pb] | Floplus 20BB | (1) | 25 | Cyst Reduction | ||
| Pentair LR-1500[Pb] | LR-FB10 | 1500(1) | 2.5 | Lead Reduction | ||
| Pentair LR-BB50[Pb] | LR-FB20BB | 40000(1) | 10 | Cyst Reduction Lead Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
| Pentair Residential Filtration, LLC | |
| 13845 Bishops Drive | |
| Suite 200 | |
| Brookfield, WI 53005 | |
| United States | |
| 800-279-9404 | |
| 262-238-4400 |
Facility : Jiangsu Province, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Pentair GRO-2550 | GS10-RO P5 EPM-10 GRO-50EN |
10.09 | Cyst Reduction TDS Reduction |
|||
| Pentair GRO-2575 | GRO-75EN | 13.96 | TDS Reduction | |||
| Pentair GRO-350B | FDF1-RC GRO50-RC F1GC-RC |
14.96 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| Pentair GRO-475B | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-475BP | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
94.38 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-575B | FDF1-RC GRO75-RC F2B2-RC2 F1GC-RC F2B1-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair RO-2550 | TLC-50 P5 EPM-10 GS-10RO |
15.04 | Arsenic (Pentavalent)<=50 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] ROR2000 is a replacement kit containing RS14, CB1, and two o-rings.
[2] ROR2050 is a replacement kit containing R200, CB1, RS14, and two o-rings.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Membrane Elements[3] |
||||||
| Pentair TLC-100[4] | ||||||
| Pentair TLC-50[4] | ||||||
| Pentair TLC-50F[4] | ||||||
|
  [3] Conforms to material requirements only. Membranes require a 24 hour flushing and
conditioning procedure.
[4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
and Selenium. The test data results may be transferred to other manufacturer's systems,
if the systems meet the requirements.
|
||||||
|
COMPONENTS: Membrane Elements, Encapsulated[4] [5] |
||||||
| Pentair GRO-50EN | ||||||
| Pentair GRO-75EN | ||||||
|
  [4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
(Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
and Selenium. The test data results may be transferred to other manufacturer's systems,
if the systems meet the requirements.
[5] Conforms to material and structural integrity requirements only. Membranes require a 24
hour flushing and conditioning procedure.
|
||||||
NOTE: These components do not bear the NSF Mark. Evidence of Certification will appear on the
manufacturer's literature and packaging.
CSA Standard B483.1
Drinking Water Treatment Systems
Drinking Water Treatment Systems
| Pentair Residential Filtration, LLC | |
| 13845 Bishops Drive | |
| Suite 200 | |
| Brookfield, WI 53005 | |
| United States | |
| 800-279-9404 | |
| 262-238-4400 |
Facility : Jiangsu Province, China
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Pentair F2000-B2B | F2B2-RC2 | 675(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Nominal Particulate Reduction, Class I Lead Reduction Taste and Odor Reduction |
||
| Pentair F3000-B2B | F2B2-RC2 | 675(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Nominal Particulate Reduction, Class I Lead Reduction Taste and Odor Reduction |
||
| Pentair GRO-350B[1] [Pb] | FDF1-RC | 750 | .75 | Chlorine Reduction Taste and Odor Reduction |
||
| Pentair GRO-475B[1] [Pb] | FDF1-RC F1B1-RC |
750(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Lead Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
| Pentair GRO-475BP[1] | FDF1-RC F1B1-RC |
750(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Lead Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
| Pentair GRO-575B[1] [Pb] | FDF1-RC F2B2-RC2 F2B1-RC |
675(1) | .6 | Atrazine Reduction Chlorine Reduction Cyst Reduction Lead Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[1] Model is a reverse osmosis system and is also Certified to NSF/ANSI 58.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Filter Housings[2] |
||||||
| Pentair 158006 | ||||||
| Pentair 158125 | ||||||
| Pentair 158125WM | ||||||
| Pentair 158196 | ||||||
| Pentair 158739 | ||||||
| Pentair 158739WM | ||||||
|
  [2] Conforms to material and structural integrity requirements only. |
||||||
[3] OmniFilter OT32
Facility : Reynosa, Mexico
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In [Pb] |
||||||
| Pentair LR-1500 | LR-FB10 | 1500(1) | 2.5 | Chlorine Reduction Taste and Odor Reduction Lead Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
COMPONENTS: Filter Housings[2] |
||||||
| Pentair 150067 | ||||||
| Pentair 150069 | ||||||
| Pentair 150071 | ||||||
| Pentair 150164 | ||||||
| Pentair 150166 | ||||||
| Pentair 150233[Pb] | ||||||
| Pentair 150234[Pb] | ||||||
| Pentair 150237[Pb] | ||||||
| Pentair 150238[Pb] | ||||||
| Pentair 150437 | ||||||
| Pentair 158205 | ||||||
| Pentair R50067[Pb] | ||||||
| Pentair R50069[Pb] | ||||||
| Pentair R50071-75[Pb] | ||||||
|
  [2] Conforms to material and structural integrity requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Facility : Dover, NH
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Replacement Element: Plumbed-In |
||||||
| Pentair Floplus 10[6] [Pb] | N/A | (1) | 5 | Cyst Reduction | ||
| Pentair Floplus 20[7] [Pb] | N/A | (1) | 10 | Cyst Reduction | ||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[3] Pentair LR-BB50
[4] OmniFilter PB35
[5] OmniFilter PB55
[6] Pentair FPS-10
[7] Pentair FPS-20
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
[2] Pentair LR-BB25
Facility : Reynosa, Mexico
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In |
||||||
| Pentair FPS-10[Pb] | Floplus 10 | (1) | 5 | Cyst Reduction | ||
| Pentair FPS-20[Pb] | Floplus 20 | (1) | 10 | Cyst Reduction | ||
| Pentair LR-BB50[Pb] | LR-FB20BB | 40000(1) | 10 | Cyst Reduction Lead Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Facility : Jiangsu Province, China
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap[Pb] |
||||||
| Pentair GRO-2550 | GS10-RO P5 EPM-10 GRO-50EN |
10.09 | Cyst Reduction TDS Reduction |
|||
| Pentair GRO-350B | FDF1-RC GRO50-RC F1GC-RC |
14.96 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction Nitrate/Nitrite Reduction |
|||
| Pentair GRO-475B | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-475BP | FDF1-RC GRO75-RC F1B1-RC F1GC-RC |
94.38 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair GRO-575B | FDF1-RC GRO75-RC F2B2-RC2 F1GC-RC F2B1-RC |
21.08 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction Turbidity Reduction TDS Reduction |
|||
| Pentair RO-2550 | EPM-10 GS-10RO P5 TLC-50 |
15.04 | Arsenic (Pentavalent)<=50 ppb Reduction Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Fluoride Reduction Lead Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  [Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
Number of matching Manufacturers is 4
Number of matching Products is 187
Processing time was 1 seconds