NSF Product and Service Listings

These NSF Official Listings are current as of Monday, October 19, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?TradeName=Whirlpool&hdModlStd=ModlStd&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects


 
Water Channel Partners 
2805 Dodd Road
Suite 300 
Eagan, MN 55121 
United States 
800-869-2837

Facility : # 1 India

 
           

COMPONENTS: Filter Cartridges[1] [G]
Whirlpool WHA2BF5  
Whirlpool WHA2FF5  
Whirlpool WHA4BF5  
Whirlpool WHA4FF5  

   
[1] Conforms to material safety only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : # 2 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Point-of-Entry[1] [Pb] [POE]
Whirlpool WHELJ1 N/A 570,000 6   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHESFC N/A 570,000 6   Chlorine Reduction
Taste and Odor Reduction

   
[1] Product also complies with NSF/ANSI Std 372.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.


Facility : # 3 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
Whirlpool WHARSS5 WHARSF5 750(1) 0.5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Whirlpool WPINL30[Pb] NA 2500 0.5   Chlorine Reduction
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plumbed-In to Separate Tap [Pb]
Whirlpool WHADUS5 WHEEDF7 270 .5   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHAMBS5 WHEMBF 350(1) .75   Chlorine Reduction
Taste and Odor Reduction
Nominal Particulate Reduction, Class I
Whirlpool WHAPSRO[4] WHEERFS 3850 .5   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHAROS5[4] WHEERF
WHEERM
3850 .5   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHEMB40 WHEMBF5 350(1) .75   Chlorine Reduction
Taste and Odor Reduction
Nominal Particulate Reduction, Class I
Whirlpool WHER25[4] WHEERF5 3850 .5   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHEUFF WHEURF 2000(1) 2   Chlorine Reduction
Taste and Odor Reduction
Nominal Particulate Reduction, Class I

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[4] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.
[5] As of 12/06/2022.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : West Haven, CT

 
           

COMPONENTS: Filter Cartridges[1] [G]
Whirlpool WHA2FF5  
Whirlpool WHA4FF5  

   
[1] Conforms to material safety only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


NSF/ANSI 44
Cation Exchange Water Softeners



 
Water Channel Partners 
2805 Dodd Road
Suite 300 
Eagan, MN 55121 
United States 
800-869-2837

Facility : # 2 USA

             

COMPONENTS: Valves, Ball[Pb] [POE]
Whirlpool WHECSV4        

   
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.

Point-of-Entry [1] [Pb] [POE]
Whirlpool WHEC46[2] 12.5   Efficiency Rated[ER]
Hardness Reduction[HR]
   
Whirlpool WHES18[2] 7   Efficiency Rated[ER]
Hardness Reduction[HR]
   
Whirlpool WHES30[2] 7.6   Hardness Reduction[HR]
Efficiency Rated[ER]
   
Whirlpool WHES33[2] 8   Hardness Reduction[HR]
Efficiency Rated[ER]
   
Whirlpool WHES40[2] 7.6   Hardness Reduction[HR]
Efficiency Rated[ER]
   
Whirlpool WHES44[2] 8.2   Hardness Reduction[HR]
Efficiency Rated[ER]
   
Whirlpool WHES48[2] 12   Hardness Reduction[HR]
Efficiency Rated[ER]
   
Whirlpool WHESFC[2] 8   Hardness Reduction[HR]
Efficiency Rated[ER]
   

   
[1] Product also complies with NSF/ANSI 372.
[1] Product also complies with NSF/ANSI 372.
[2] Product evaluated and determined to comply with efficiency rating requirements defined
    by California state laws.
[ER] Softener Efficiency indicates that the softener achieves a minimum of 3,350 grains of
     hardness removed per pound of regenerant salt (477 grams of hardness removed per
     kilogram of regenerant salt), and also that it uses 5 gallons or less of regenerant
     water per 1,000 grains of hardness removed (18.9 liters or less of regenerant water per
     64.8 grams of hardness removed).
[HR] Hardness Reduction indicates that the published capacity ratings for reducing hardness
     have been verified.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.


Facility : # 3 USA

             

COMPONENTS: Valves, Ball[Pb] [POE]
Whirlpool WHECSV4        

   
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[POE] Point of Entry - Product conforms to NSF/ANSI/CAN 61 health effects requirements.


NSF/ANSI 53
Drinking Water Treatment Units - Health Effects



 
Water Channel Partners 
2805 Dodd Road
Suite 300 
Eagan, MN 55121 
United States 
800-869-2837

Facility : # 3 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
Whirlpool WHARSS5 WHARSF5 750(1) .5   Cyst Reduction
Lead Reduction
Atrazine Reduction
Lindane Reduction
Turbidity Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plumbed-In to Separate Tap [Pb]
Whirlpool WHADUS5 WHEEDF7 270(1) .5   Cyst Reduction
Lead Reduction
MTBE Reduction
VOC Reduction **
Whirlpool WHAMBS5 WHEMBF 350(1) .75   Lead Reduction
Atrazine Reduction
Lindane Reduction
Cyst Reduction
Whirlpool WHEMB40 WHEMBF5 350(1) .75   Lead Reduction
Atrazine Reduction
Lindane Reduction
Cyst Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] As of 12/06/2022.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



 
Water Channel Partners 
2805 Dodd Road
Suite 300 
Eagan, MN 55121 
United States 
800-869-2837

Facility : # 3 USA

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap [1] [Pb]
Whirlpool WHAPSRO WHEERF
WHEERM
  14.76   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Nitrate/Nitrite Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Whirlpool WHAROS5 WHEERF
WHEERM
  14.76   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Nitrate/Nitrite Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Whirlpool WHER25 WHEERF
WHEERM
  14.76   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Nitrate/Nitrite Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Model has a post filter that is also Certified to NSF/ANSI Standard 42.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.

NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants



 
Water Channel Partners 
2805 Dodd Road
Suite 300 
Eagan, MN 55121 
United States 
800-869-2837

Facility : # 3 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In[Pb]
Whirlpool WHARSS5 WHARSF5 750 .5   Microplastics Reduction

   
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plumbed-In to Separate Tap [Pb]
Whirlpool WHAMBS5 WHEMBF 350(1) .75   Microplastics Reduction
Whirlpool WHEMB40 WHEMBF5 350(1) .75   Microplastics Reduction
Whirlpool WHEUFF WHEURF 2000 2   Microplastics Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


CSA Standard B483.1
Drinking Water Treatment Systems



 
Water Channel Partners 
2805 Dodd Road
Suite 300 
Eagan, MN 55121 
United States 
800-869-2837

Facility : # 3 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
Whirlpool WPINL30[Pb] NA 2500 0.5   Chlorine Reduction
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plumbed-In to Separate Tap [Pb]
Whirlpool WHADUS5 WHEEDF7 270 .5   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHAROS5[2] WHEERF
WHEERM
3850 .5   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHER25[2] WHEERF5 3850 .5   Chlorine Reduction
Taste and Odor Reduction
Whirlpool WHEUFF WHEURF 2000(1) 2   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim
Whirlpool WHADUS5 WHEEDF7 270(1) .5   Cyst Reduction
Lead Reduction
MTBE Reduction
VOC Reduction **

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                
  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap [1] [Pb]
Whirlpool WHAROS5 WHEERF
WHEERM
  14.76   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Nitrate/Nitrite Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Whirlpool WHER25 WHEERF
WHEERM
  14.76   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Nitrate/Nitrite Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Model has a post filter that is also Certified to NSF/ANSI Standard 42.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Number of matching Manufacturers is 6
Number of matching Products is 46
Processing time was 0 seconds