NSF Product and Service Listings

These NSF Official Listings are current as of Tuesday, December 3, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?TradeName=bW60%2D1812%2D75&hdModlStd=ModlStd&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



 
FilmTec Corporation 
5400 Dewey Hill Road
Edina, MN 55439 
United States 
952-897-4269
Visit this company's website

Facility : # 2 USA

             

COMPONENTS: Membrane Elements[2]
BW60-1812-75[Pb]    
BW60-1812-75 (11018585)[7] [Pb]    
BW60-1812-75 (GMID 99017671)[7] [Pb]    

   
[2] Conforms to material requirements only.  Membrane requires a 24 hour flushing and
    conditioning prodecure.
[6] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
    (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228, Selenium,
    Turbidity, and TDS.  The test data results may be transferred to other manufacturer's
    systems, if the systems meet the requirements contained on the document entitled, "Data
    Transfer Procedure for Devices using Filmtec Reverse Osmosis", dated 12/19/2011.  This
    document is available from FilmTec.
[7] BW60-1812-75 (11018585) and BW60-1812-75 (GMID 99017671) has been tested for the
    reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),
    Copper, Fluoride, Lead, Radium 226/228, Selenium,Turbidity, and TDS.  The test data
    results may be transferred to other manufacturer's systems, if the systems meet the
    requirements contained on the document entitled, "DataTransfer Procedure for Devices
    using Filmtec Reverse Osmosis", dated 08/13/2010.  This document is available from
    FilmTec.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
MCM Co., Ltd. 
486, Jingwang-ro, Iwol-myeon
Jincheon-gun, Chungcheongbukdo 365-842 
Korea, Republic of 
82 43 531 7021

Facility : Chungcheongbukdo, Republic of Korea

             

COMPONENTS: Membrane Elements
BW60-1812-75[2]    

   
[2] Conforms to material requirements only. Membrane requires a 24 hour flushing and
    conditioning procedure.
[3] TW30-1812-50, TW30-1812-75 have been tested for the reduction of Arsenic, Barium,
    Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium
    226/228, Selenium, Turbidity, and TDS.  The test data results may be transferred to
    other manufacturer's systems, if the systems meet the requirements contained on the
    document entitled "Transfer of Performance Claims for MCM Co., Ltd. Reverse Osmosis
    Elements", dated 10/10/2013.  This document is available from MCM Co., Ltd.  A data
    transfer has been accepted for the reduction of Arsenic, Barium, Cadmium, Chromium
    (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228, Selenium,
    Turbidity, and TDS.
[4] Model Trade Names which end in numerals from 0-120 are associated with a data transfer
    protocol. See manufacturer for more information.
    A data transfer has been accepted for the reduction of Arsenic, Barium, Cadmium,
    Chromium (Hexavalent), Chromium (Trivalent), Copper, Fluoride, Lead, Radium 226/228,
    Selenium, Turbidity, and TDS.
[5] The models are not claiming TDS reduction.
    

[6] Conforms to material requirements only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


 
Royal Green Su Aritma Sistemleri San Dis Tic. Ltd. Sti 
Yayalar Mah. Atasever Cd. No:42
Pendik, 34909 Istanbul 
Turkey 
90 216 444 18 22
Visit this company's website

Facility : Istanbul, Turkey

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Royal Green Lux Plus RG-BW60-1812-75   21.22   TDS Reduction
Royal Green Picasso RG-BW60-1812-75   21.22   TDS Reduction
Royal Green Softlime RG-BW60-1812-75   21.22   TDS Reduction


Number of matching Manufacturers is 3
Number of matching Products is 7
Processing time was 0 seconds