NSF Product and Service Listings

These NSF Official Listings are current as of Wednesday, April 23, 2014 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=169&Company=21200&


NSF/ANSI 169
Special Purpose Food Equipment and Devices



 
Hartell Pumps-Milton Roy Co. 
8 Post Office Square
Acton, MA 01720 
United States 
978-635-4956
Visit this company's website

Facility : Acton, MA


Evaluated under Provisions of NSF Standard 12 - Automatic Ice Making Equipment

COMPONENTS:

Plastic Pump
  DI-3RC-1
  DI-3RC-1A
  DI-4RC-4
  DI-4RC-4A
  DI-6RC-4
  GBB-00208-FF-B
  GBB-00208-B
  GTT-00206-FF-B
  GTT-00204-B
  GTT-209-FF-B
  516-1012-01
  516-1012-02
  GBR-00208
  GTR-00204

General Purpose Pump
  GPPS-BBCC-EFG[2]
  GPPS-5SC-1
  GPPS-5SC-4
  GPPA-BBCC-EFG[1]
 
[1] GPP   - Identifies the pump series
    A     - Identifies motor style within series
    Blank - Can (3.3) motor style
    U     - Unit bearing motor
    C     - C-Frame
    BB    - 1-20 - Identifies model number within series
    CC    - Two Letter Customer Identification
    E     - 1-10 - Identifies motor voltage and frequency
               1     115vac    60 Hz
               2     230vac    60 Hz
               3     230vac    50 Hz
               4     230vac    50/60 Hz
               5-10  Open identifiers
    F     - Letter A - Z
            When used distinguishes between nearly identical pumps with only minor 
            variations (i.e. wire length, electrical termination, orientation of 
            discharge, etc.)
            Blank - Base pump (Noryl plastic)
    G     - Underwriters Laboratory code
            Blank - recognized component
    UL    - Listed
          * May or may not contain a prefix that identifies the version:
              No prefix - Jobber
              Prefix A  - OEM
[2] GPPS  - Identifies the pump series
    Blank - Can (3.3) motor style
    U     - Unit bearing motor
    C     - C-Frame
    BB    - 1-20 - Identifies model number within series
    CC    - Two letter customer identification
    E     - 1-10 - Identifies motor voltage and frequency
               1     115vac  60 Hz
               2     230vac  60 Hz
               3     230vac  50 Hz
               4     230vac  50/60 Hz
               5-10  Open Identifiers
       F  - Letter A-Z
            When used distinguishes between nearly identical pumps with only minor
            variations (i.e. wire length, electrical termination, orientation of 
            discharge, etc.)
            Blank - Base Pump (Noryl plastic)
       G  - Underwriters Laboratory code
            Blank - Recognized component
       UL - Listed
          * May or may not contain a prefix that indentifies the version:
              No prefix - Jobber
              Prefix A  - OEM
    

Carbonated Water Pump
  CP-7F-1
  CP-7NES-2
  CP-7R-12HE
  CP-17R-2B
  CP-17H-2B
  CP-7F-2B
  CP-7MCI-2
  CP-7LJ-1
  CP-17R-4
  CP-17-MCI-1
  CP-7H-2
  CP-7R-1A
  CP-7LJ-2
  CP-17LJ-1
  CP-7AS-1
  CP-7R-2B
  CP-17R-1A
  CP-17LJ-4
  CP-7MCI-1
  CP-SAM-1
  CP-17MCI-4
  CP-17H-1
  CP-17R-1B
  CP-17R-4B

Potable Water Pumps CP SERIES[3]
  CP-AB-CD
 
[3] CP - Identifies the Pump Series as "CP"
    A  - Number code that specifies housing material, plumbing connections type & motor RPM
         1500 RPM  3000 RPM
             3         10  - Copper housing with 1/2" NPTM connections (housing P/N: 300070)
             4         12  - Copper housing with 3/8" NPTF connections (housing P/N: 650007)
             5         14  - Copper housing with 5/8" flare fitting connections (housing
    P/N:
                             300072)
             7         17  - Ryton housing with stainless steel pinned adapter for 3/8" NPTF
    
                             connections (housing P/N: 200321)
             8         18  - Copper housing with 1/2" sweat connections (housing P/N:
    300091)
             9         19  - Special configurations (housing P/N: 620114)
    B  - Letter code (0 to 4 characters in length) that identifies customer
    C  - Code that identifies motor voltage and frequency
           1    - 115 VAC, 60 Hz                
           2    - 230 VAC, 60 Hz              
           3    - 115 VAC, 50/60 Hz
           4    - 230 VAC, 50/60 Hz
           12DC - 12 VDC, brush style motor
           24DC - 24 VDC, brush style motor
           12HE - 12 VDC, brushless style motor
           DCL  - 12 VDC, brush style motor
           DCH  - 24 VDC, brush style motor
           HEL  - 12 VDC, brushless style motor
           HEH  - 12 VDC, brushless style motor
    D  - Letter code (0 to 3 characters in length) that distinguishes between nearly
         identical pumps with minor variations
         (variations within this code are limited to wiring length and termination type,
         housing orientation, etc. This code does not affect materials of construction)
    E  - Letter code (0 to 1 characters in length) that states listed with alternate
         agencies/certifiers
         U - Underwriters Laboratory

Potable Water Pumps MD SERIES[4]
  MD-ABC-DEF
 
[4] MD - Identifies the pump series as "MD"
    A  - Number code that specifies housing material, plumbing connections type & motor RPM
         1500 RPM  3000 RPM
             3         10  - Copper housing with 1/2" NPTM connections (housing P/N: 300070)
             4         12  - Copper housing with 3/8" NPTF connections (housing P/N: 650007)
             5         14  - Copper housing with 5/8" flare fitting connections 
                             (housing P/N: 300072)
             7         17  - Ryton housing with stainless steel pinned adapter for 3/8" NPTF
                             connections (housing P/N: 200321)
             8         18  - Copper housing with 1/2" sweat connections (housing P/N:
    300091)
             9         19  - Special configurations (housing P/N: 620114)           
    B  - Letter Code (0 to 4 characters in length) that identifies customer
    C  - Code that identifies motor voltage & frequency
           1    - 115 VAC, 60 Hz
           2    - 230 VAC, 60 Hz
           3    - 115 VAC, 50/60 Hz
           4    - 230 VAC, 50/60 Hz
           12DC - 12 VDC, brush style motor
           24DC - 24 VDC, brush style motor
           12HE - 12 VDC, brushless style motor
           DCL  - 12 VDC, brush style motor
           DCH  - 24 VDC, brush style motor
           HEL  - 12 VDC, brushless style motor
           HEH  - 12 VDC, brushless style motor
    D  - Letter code (0 to 3 characters in length) that distinguishes between nearly
         identical pumps with minor variations
         (variations within this code are limited to wiring length and termination type,
         housing orientation, etc. This code does not affect materials of construction)
    E  - Letter code (0 to 1 characters in length) that states listed with alternate
         agencies/certifiers
         U  - Underwriters Laboratory


Number of matching Manufacturers is 1
Number of matching Products is 45