NSF Product and Service Listings

These NSF Official Listings are current as of Wednesday, December 19, 2018 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=169&Company=41040&


NSF/ANSI 169
Special Purpose Food Equipment and Devices



 
ODE SRL Società Unipersonale 
Via Borgofrancone, 18
23823 Colico 
Italy 
39 03 419 30570

Facility : Colico, Italy


COMPONENTS:

Brass Special Solenoid Valves Series[1] [2] [Pb]
  (16)(3)(4)(5)(6)-(7)T3
  G(11)(16)(12)(3)(4)(13)(3)(4)-(7)T3
  G(11)(16)(12)(3)(4)-(7)T3
 
[1] (1)  Body type full description, one, two or three characters
    (2)  Fittings size or type, one or two characters
    (3)  Fixed core type, one or two letter
    (4)  1, 4, 6, 8 are Copper Ring and plunger type
    (5)  One character indicating sealing material
    (6)  Diameter of orifice (10e - 1mm), two or three digits
    (7)  Possible Further Description, one or two characters
    (8)  Number of elements 
    (9)  Inlet side and type: one character
    (10) Module decription, from two to six characters
    (11) Release number (one character)
    (12) Number of valve with first type of armature tube, one character
    (13) Number of valve with second type of armature tube, one character
    (15) Type of armature tube, one character, optional
    (16) Project ID, four characters: 4622, 4767, 5125, 5329, 5765, 5850, 5983, 6061, 5716
    or 5718
[2] Models are acceptable for use in contact with coffee, tea and water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Brass Standard Solenoid Valves Series[1] [2] [Pb]
  21(15)(1)(2)(3)(4)(5)(6)-(7)T3
  31(15)(1)(2)(3)(4)(5)(6)-(7)T3
 
[1] (1)  Body type full description, one, two or three characters
    (2)  Fittings size or type, one or two characters
    (3)  Fixed core type, one or two letter
    (4)  1, 4, 6, 8 are Copper Ring and plunger type
    (5)  One character indicating sealing material
    (6)  Diameter of orifice (10e - 1mm), two or three digits
    (7)  Possible Further Description, one or two characters
    (8)  Number of elements 
    (9)  Inlet side and type: one character
    (10) Module decription, from two to six characters
    (11) Release number (one character)
    (12) Number of valve with first type of armature tube, one character
    (13) Number of valve with second type of armature tube, one character
    (15) Type of armature tube, one character, optional
    (16) Project ID, four characters: 4622, 4767, 5125, 5329, 5765, 5850, 5983, 6061, 5716
    or 5718
[2] Models are acceptable for use in contact with coffee, tea and water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Plastic Modular Sets Series[1]
  2(8)M(9)(10)(11)-T0
  3(8)M(9)(10)(11)-T0
 
[1] (1)  Body type full description, one, two or three characters
    (2)  Fittings size or type, one or two characters
    (3)  Fixed core type, one or two letter
    (4)  1, 4, 6, 8 are Copper Ring and plunger type
    (5)  One character indicating sealing material
    (6)  Diameter of orifice (10e - 1mm), two or three digits
    (7)  Possible Further Description, one or two characters
    (8)  Number of elements 
    (9)  Inlet side and type: one character
    (10) Module decription, from two to six characters
    (11) Release number (one character)
    (12) Number of valve with first type of armature tube, one character
    (13) Number of valve with second type of armature tube, one character
    (15) Type of armature tube, one character, optional
    (16) Project ID, four characters: 4622, 4767, 5125, 5329, 5765, 5850, 5983, 6061, 5716
    or 5718

Plastic Solenoid Valves Series[1]
  216A(1)(2)(3)(4)(5)(6)-(7)T0
  216J(1)(2)(3)(4)(5)(6)-(7)T0
  21A(1)(2)(3)(4)(5)(6)-(7)T0
  21J(1)(2)(3)(4)(5)(6)-(7)T0
  316A(1)(2)(3)(4)(5)(6)-(7)T0
  316J(1)(2)(3)(4)(5)(6)-(7)T0
  31A(1)(2)(3)(4)(5)(6)-(7)T0
  31J(1)(2)(3)(4)(5)(6)-(7)T0
 
[1] (1)  Body type full description, one, two or three characters
    (2)  Fittings size or type, one or two characters
    (3)  Fixed core type, one or two letter
    (4)  1, 4, 6, 8 are Copper Ring and plunger type
    (5)  One character indicating sealing material
    (6)  Diameter of orifice (10e - 1mm), two or three digits
    (7)  Possible Further Description, one or two characters
    (8)  Number of elements 
    (9)  Inlet side and type: one character
    (10) Module decription, from two to six characters
    (11) Release number (one character)
    (12) Number of valve with first type of armature tube, one character
    (13) Number of valve with second type of armature tube, one character
    (15) Type of armature tube, one character, optional
    (16) Project ID, four characters: 4622, 4767, 5125, 5329, 5765, 5850, 5983, 6061, 5716
    or 5718

Plated Brass Solenoid Valves Series[1]
  21A(1)(2)(3)(4)(5)(6)-(7)T1
  21A(1)(2)(3)(4)(5)(6)-(7)T2
  21H(1)(2)(3)(4)(5)(6)-(7)T1
  21H(1)(2)(3)(4)(5)(6)-(7)T2
  21J(1)(2)(3)(4)(5)(6)-(7)T1
  21J(1)(2)(3)(4)(5)(6)-(7)T2
  21T(1)(2)(3)(4)(5)(6)-(7)T1
  21T(1)(2)(3)(4)(5)(6)-(7)T2
  21W(1)(2)(3)(4)(5)(6)-(7)T1
  21W(1)(2)(3)(4)(5)(6)-(7)T2
  31A(1)(2)(3)(4)(5)(6)-(7)T1
  31A(1)(2)(3)(4)(5)(6)-(7)T2
  31J(1)(2)(3)(4)(5)(6)-(7)T1
  31J(1)(2)(3)(4)(5)(6)-(7)T2
 
[1] (1)  Body type full description, one, two or three characters
    (2)  Fittings size or type, one or two characters
    (3)  Fixed core type, one or two letter
    (4)  1, 4, 6, 8 are Copper Ring and plunger type
    (5)  One character indicating sealing material
    (6)  Diameter of orifice (10e - 1mm), two or three digits
    (7)  Possible Further Description, one or two characters
    (8)  Number of elements 
    (9)  Inlet side and type: one character
    (10) Module decription, from two to six characters
    (11) Release number (one character)
    (12) Number of valve with first type of armature tube, one character
    (13) Number of valve with second type of armature tube, one character
    (15) Type of armature tube, one character, optional
    (16) Project ID, four characters: 4622, 4767, 5125, 5329, 5765, 5850, 5983, 6061, 5716
    or 5718

Rotary Pump PR Series[3] [Pb]
  PR(1)(2)(3)(4)(5)(6)(7)-T0[4]
 
[3] Models are Certified for water contact only
[4] (1) 3 digit for flow rate
    (2) 1 character for body material. "p" means pps material
    (3) 1 character for sealing material
    (4) 1 digit (number or character) for connection dimension
    (5) 1 digit for connection type (gas/npt/push in…)
    (6) 2 digit (numbers) for pressure calibration
    (7) Optional 2 digit suffix indicating customer-specific code
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Solenoid Valve Series D62[3] [5] [6] [7] [8]
  21D62KRS50-(2)
  21D62KRS90-(2)
  21D62RRS50-(2)
  21D62RRS90-(2)
  R21D62KRS50-(2)
  R21D62KRS90-(2)
  R21D62RRS50-(2)
  R21D62RRS90-(2)
 
[3] Models are Certified for water contact only
[5] Valves are NSF Certified from serial number 00/011174
[6] (1) Number of elements within the block
    (2) 1-8 digits, indicating options for diameter, usable length, lip
        seal, or customer specific requests
[7] Models with R prefix are without coil
[8] Model numbers may or may not be followed by suffix -4723', indicating valves with bottom
    body and side outlet.

Solenoid Valve Series D72[3] [6] [7] [8] [9]
  21D72KRS50-(2)
  21D72KRS90-(2)
  21D72RRS50-(2)
  21D72RRS90-(2)
  R21D72KRS50-(2)
  R21D72KRS90-(2)
  R21D72RRS50-(2)
  R21D72RRS90-(2)
 
[3] Models are Certified for water contact only
[6] (1) Number of elements within the block
    (2) 1-8 digits, indicating options for diameter, usable length, lip
        seal, or customer specific requests
[7] Models with R prefix are without coil
[8] Model numbers may or may not be followed by suffix -4723', indicating valves with bottom
    body and side outlet.
[9] Valves are NSF Certified from serial number 04/0002495

Solenoid Valve Series K62[3] [5] [6] [7] [8]
  2(1)K62KRS50-(2)
  2(1)K62KRS90-(2)
  2(1)K62RRS50-(2)
  2(1)K62RRS90-(2)
  R2(1)K62KRS50-(2)
  R2(1)K62KRS90-(2)
  R2(1)K62RRS50-(2)
  R2(1)K62RRS90-(2)
 
[3] Models are Certified for water contact only
[5] Valves are NSF Certified from serial number 00/011174
[6] (1) Number of elements within the block
    (2) 1-8 digits, indicating options for diameter, usable length, lip
        seal, or customer specific requests
[7] Models with R prefix are without coil
[8] Model numbers may or may not be followed by suffix -4723', indicating valves with bottom
    body and side outlet.

Solenoid Valve Series K72[3] [6] [7] [8] [9]
  2(1)K72KRS50-(2)
  2(1)K72KRS90-(2)
  2(1)K72RRS50-(2)
  2(1)K72RRS90-(2)
  R2(1)K72KRS50-(2)
  R2(1)K72KRS90-(2)
  R2(1)K72RRS50-(2)
  R2(1)K72RRS90-(2)
 
[3] Models are Certified for water contact only
[6] (1) Number of elements within the block
    (2) 1-8 digits, indicating options for diameter, usable length, lip
        seal, or customer specific requests
[7] Models with R prefix are without coil
[8] Model numbers may or may not be followed by suffix -4723', indicating valves with bottom
    body and side outlet.
[9] Valves are NSF Certified from serial number 04/0002495

Solenoid Valve Series SB[3] [6]
  21SBGS4E30-(2)
  21SBGS4E50-(2)
 
[3] Models are Certified for water contact only
[6] (1) Number of elements within the block
    (2) 1-8 digits, indicating options for diameter, usable length, lip
        seal, or customer specific requests

Stainless Steel Solenoid Valves Series[1]
  21J(1)(2)(3)(4)(5)(6)-(7)T4
  21L(1)(2)(3)(4)(5)(6)-(7)T4
  21X(1)(2)(3)(4)(5)(6)-(7)T4
  31J(1)(2)(3)(4)(5)(6)-(7)T4
  31L(1)(2)(3)(4)(5)(6)-(7)T4
 
[1] (1)  Body type full description, one, two or three characters
    (2)  Fittings size or type, one or two characters
    (3)  Fixed core type, one or two letter
    (4)  1, 4, 6, 8 are Copper Ring and plunger type
    (5)  One character indicating sealing material
    (6)  Diameter of orifice (10e - 1mm), two or three digits
    (7)  Possible Further Description, one or two characters
    (8)  Number of elements 
    (9)  Inlet side and type: one character
    (10) Module decription, from two to six characters
    (11) Release number (one character)
    (12) Number of valve with first type of armature tube, one character
    (13) Number of valve with second type of armature tube, one character
    (15) Type of armature tube, one character, optional
    (16) Project ID, four characters: 4622, 4767, 5125, 5329, 5765, 5850, 5983, 6061, 5716
    or 5718

Totally Separation Valve - 21KL and 31KL Series[10]
  21KL(1)(2)KR(3)(4)-(5)T0
  31KL(1)(2)KR(3)(4)-(5)T0
 
[10] (1) Fluidific Function			
         A - Normally Open			
         C - Normally Closed			
         D - Diverter			
         S - Pressure Selector			
     (2) Fitting Type and Size			
         F1 - G 1/8 Female			
         F2 - G 1/4 Female			
         M1 - G 1/8 Male			
         M2 - G 1/4 Male			
         M3 - M 15 Male for pipe diameter 4			
         M4 - M 15 Male for pipe diameter 6			
         M5 - M 15 Male for pipe diameter 8			
         J3 - pipe diameter 3, with ogive			
         L9 - Straight joint diameter 9			
         P1 - push in connection diameter 4			
         P2 - push in connection diameter 6			
         P3 - push in connection diameter 8			
         P4 - hose holding connection for pipe diameter 10
     (3) Sealing Material			
         S - Silicone			
         V - VKM			
     (4) Orifice Diameter 10e-1 mm			
         2 digits indicating diameter size			
     (5) Customer Code			
         2 digits indicating customer code

Totally Separation Valve - 21KP and 31KP Series[10]
  21KP(1)(2)KR(3)(4)-(5)T0
  31KP(1)(2)KR(3)(4)-(5)T0
 
[10] (1) Fluidific Function			
         A - Normally Open			
         C - Normally Closed			
         D - Diverter			
         S - Pressure Selector			
     (2) Fitting Type and Size			
         F1 - G 1/8 Female			
         F2 - G 1/4 Female			
         M1 - G 1/8 Male			
         M2 - G 1/4 Male			
         M3 - M 15 Male for pipe diameter 4			
         M4 - M 15 Male for pipe diameter 6			
         M5 - M 15 Male for pipe diameter 8			
         J3 - pipe diameter 3, with ogive			
         L9 - Straight joint diameter 9			
         P1 - push in connection diameter 4			
         P2 - push in connection diameter 6			
         P3 - push in connection diameter 8			
         P4 - hose holding connection for pipe diameter 10
     (3) Sealing Material			
         S - Silicone			
         V - VKM			
     (4) Orifice Diameter 10e-1 mm			
         2 digits indicating diameter size			
     (5) Customer Code			
         2 digits indicating customer code

Totally Separation Valve - 21KU and 31KU Series[10]
  21KU(1)(2)KR(3)(4)-(5)T0
  31KU(1)(2)KR(3)(4)-(5)T0
 
[10] (1) Fluidific Function			
         A - Normally Open			
         C - Normally Closed			
         D - Diverter			
         S - Pressure Selector			
     (2) Fitting Type and Size			
         F1 - G 1/8 Female			
         F2 - G 1/4 Female			
         M1 - G 1/8 Male			
         M2 - G 1/4 Male			
         M3 - M 15 Male for pipe diameter 4			
         M4 - M 15 Male for pipe diameter 6			
         M5 - M 15 Male for pipe diameter 8			
         J3 - pipe diameter 3, with ogive			
         L9 - Straight joint diameter 9			
         P1 - push in connection diameter 4			
         P2 - push in connection diameter 6			
         P3 - push in connection diameter 8			
         P4 - hose holding connection for pipe diameter 10
     (3) Sealing Material			
         S - Silicone			
         V - VKM			
     (4) Orifice Diameter 10e-1 mm			
         2 digits indicating diameter size			
     (5) Customer Code			
         2 digits indicating customer code


Number of matching Manufacturers is 1
Number of matching Products is 75
Processing time was 0 seconds