ABB Installation Products Inc. 
860 Ridgelake Boulevard
Memphis, TN 38120 
United States 
901-252-5000

Facility : Portland, TN


COMPONENTS:

Wall Offset for Splash Zone
  SC-WO-1/2
  SC-WO-3/8


Facility : Dorval, Quebec, Canada


LIGHTING FIXTURE FOR SPLASH/NON FOOD ZONE APPLICATIONS

EMERGI-LITE BRAND[1]

EF39 Series - Remote Unit
  (Canadian) EF39(1)(2)(3)-(4)[2]
  (US) EF39(1)(2)-(3)[3]
 
[2] (1) Number of heads: blank - 1 lamp, D - 2 lamp
    (2) Lamp type: M - MR16
    (3) Color: Blank - White, or A to Z for other colors
    (4) Voltage/wattage:
        6VXXW                - 6V, max 20W
        12VXXW               - 12V, max 20W
        24VXXW               - 12V, max 20W
        120VXXW              - 120V, max 20W
        L to L99 or LA to LZ - LED Lamp 6V, 12V, 24V or 120V, Max 6W
[3] (1) Number of Lamps: blank - 1 lamp, D - 2 lamp
    (2) Lamp/wattage:
        LA to LZ - LED Lamp 6V, 12V or 24V, Max 6W
        MA to MZ - MR16 lamp 6V, 12V or 24V Max 20W
    (3) Color: Blank - AA to ZZ

EN Series Pictogram Sign
  EN(1)(2)(3)(4)(5)[27]
 
[27] (1) Faces:    
         1 - Single face   
         2 - Double face   
     (2) Arrow Configuration:     
         Blank - Standard   
         U9    - Arrow Up   
         D9    - Arrow Down   
         U4    - Arrow Up 45º   
         D4    - Arrow Down 45º   
     (3) Body color:  A to Z   
     (4) Voltage:   
         I        - 120-347 VAC self-powered   
         ID       - 120-347 VAC self-powered w/diagnostics   
         ID2      – 120/2777 VAC self-powered w/diagnostics   
         U        - Universal 120-347 VAC, 6-24vdc   
         U00      - Universal 120-347 VAC   
         U36      - Universal 120-347 VAC, 36vdc   
         U48      - Universal 120-347 VAC, 48vdc   
         U120     - Universal 120-347 VAC, 120vdc   
         EM120-2W - 2-Wires 120VAC, 120Vdc   
         NEX      - Nexus interface wired 120/347Vac   
         NEXRF    - Nexus interface wireless 120/347Vac   
     (5) Options:   
         Blank - No Option   
         CW    - Cold weather

ENC Series Pictogram Combo Unit
  ENC(1)(2)(3)(4)(5)/(6)[26]
 
[26] (1) Faces:    
         1 - Single face   
         2 - Double face   
     (2) Arrow Configuration:     
         Blank - Standard   
         U9    - Arrow Up   
         D9    - Arrow Down   
         U4    - Arrow Up 45º   
         D4    - Arrow Down 45º     
     (3) Housing/faceplate color: A to Z    
     (4) Battery Type & Power:    
         6N36  - 6V-36W, Nickel-Cadmium   
         12N60 - 12V-60W, Nickel-Cadmium   
     (5) Lamps/wattage:    
         Blank    – No lamp      
         LA to LZ - LED Lamp 6V or 12V Max 6W   
         MA to MZ - MR16 lamp 6V or 12V Max 12W   
     (6) Options:   
         Blank – 120/347 VAC Advanced diagnostics non audible   
         -2    - 120/2777 VAC   
         D3    - Time Delay 15 minutes   
         U     - Advanced diagnostics audible   
         NEX   - Nexus interface wired   
         NEXRF - Nexus interface wireless   
         CW    - Cold weather

LPEX60-NEMA-4X Series Combo Unit
  LPEX60(1)(2)-(3)-(4)(5)/(6)(7)[4]
 
[4] (1) Faces: 2 - Single face, 3 - Double face
    (2) Housing/faceplate color: AA to ZZ 
    (3) Voltage: 
        Blank - For CW1, CW2 or CW3, 
        2     - 120/277V, 
        3     - 120/347V
    (4) Powerpack: N3 - 6V-36W, N6A - 12V-60W
    (5) Options:
        Blank - Advanced diagnostics non audible
        CW    - Cold weather120/277V or 120/347V
        CW1   - Cold weather 120V
        CW2   - Cold weather 277V
        CW3   - Cold weather 347V
        G     - Green letters
        U     - Advanced diagnostics audible
        NEX   - Nexus interface wired
        NEXRF - Nexus interface wireless
    (6) Number of heads: Blank - No heads, 2  - 2 heads
    (7) Lamps/wattage: 
        LA to LZ - LED Lamp 6V or 12V Max 6W
        MA to MZ - MR16 lamp 6V or 12V Max 12W

LPEX600 Series Exit Sign
  LPEX60(1)(2)(3)(4)(5)[5]
 
[5] (1) Faces: 2 - Single face, 3 - Double face
    (2) Body color:  AA to ZZ
    (3) Voltage:
        EM120-2W  - 120VAC, 120Vdc,
        EM120-2WW - 120VAC, 120Vdc (White LED)
        ID        - 120-347 VAC self powered w/diagnostics,
        ID2       – 120/2777 VAC self-powered w/diagnostics
        ID3       – 120/3477 VAC self-powered w/diagnostics
        U         - Univeral 120-347 VAC, 6-48vdc
        UW        - Univeral 120-347 VAC, 6-24vdc (White LED)
        NEX       - Nexus interface wired 120-347VAC
        NEX2      - Nexus interface wired 120/277VAC (White LED)
        NEX3      - Nexus interface wired 120/347Vac (White LED)
        NEXRF2    - Nexus interface wireless 120/277Vac (White LED)
        NEXRF3    - Nexus interface wireless 120/347Vac (White LED)
    (4) Options:
        CW - Cold weather
        G  - Green letters
    (5) Cabinet: 
        4X - Nema 4X

NXM Series Unit Equipment
  (1)(2)(3)(4)(5)/(6)(7)(8)[6]
 
[6] (1) 06NXM - 6V Unit
        12NXM - 12V Unit
    (2) Color: Blank - Factory white, B - Black, G - Silver Gray or A to Z
    (3) Capacity: 36 - 6V-36W, 72 - 12V-72W, 108 - 12V-108W
    (4) AC voltage: Blank - 120/347vac, 2 - 277vac
    (5) Charger: 
        Blank - Autodiagnostic, 
        NEX   - Nexus interface wired
        NEXRF - Nexus interface wireless
    (6) Options: 
        Blank                - No options, 
        CW1                  - Cold weather 120vac, 
        CW3                  - Cold weather 347vac (available in 6V only),
        D1, D2, D3, D4 or D5 – 5, 10, 15, 20 or 30 minutes time delay
    (7) Number of heads: 2 - Two heads
    (8) Lamps:
        LA to LZ - LED Lamp 6V or 12V Max 6W 
        MA to MZ - MR16 lamp 6V or 12V Max 20W

SVX Series Combo Unit
  (1)SVX(2)(3)(4)(5)(6)(7)(8)(9)[7]
 
[7] (1) Housing/face color: AA to ZZ
    (2) Capacity: 12N - 6V-12W, 24N - 12V-24W
    (3) Faces: 1 - Single face, 2- Double face
    (4) Letter color: G - Green,  R - Red
    (5) Diagnostics: 
        Blank - Standard 
        D     - Advanced Diagnostics - non audible 
        DA    - Advanced diagnostics – audible
        NEX   - Nexus interface wired
        NEXRF - Nexus interface wireless
    (6) Housing: 4X - NEMA 4X
    (7) Number of Heads: Blank - no heads, 2 - Two heads
    (8) Lamp wattage:
        LA to LZ - LED Lamp 6V or 12V Max 6W
        MA to MZ - MR16 lamp 6V, 12V or 24V Max 20W
    (9) Options:
        CW4 - Cold weather (120/277V, available in single face only)
        CW1 - Cold weather (120V, available in single face only)
        CW2 - Cold weather (277V, available in single face only)
        FA  - Flasher (fire alarm activated)
        FB  - Flasher/Buzzer
        FL  - Flasher (AC power failure)

Survive-All SVX Series Exit Sign
  (1)(2)-(3)(4)-(5)(6)(7)[8]
 
[8] (1) Housing/face color: AA to ZZ
    (2) Series: SVX - AC only, SVXN - Self powered nickel-cadmium battery
    (3) Faces: 1 - Single face, 2 - Double face
    (4) Letter color: G - Green letters, R - Red letters
    (5) Diagnostics:
        Blank   - Standard
        D       - Diagnostics
        NEX     - Nexus interface wired (SVXN only)
        NEXRF   - Nexus interface wireless (SVXN only)
    (6) Housing: 4X - NEMA 4X
    (7) Options:
        2CKT  - Dual Circuit (SVX only)
        Blank - AC only
        CW    - Cold weather (available in single face, 6V-12W only)
        FA    - Flasher (fire alarm activated)
        FL    - Flasher (AC power failure)
        FZ    - Flasher/buzzer (AC power failure - not available with 
        "AD" option)
        W     - White LED
        DC    - 6-48 Vdc

Survive-All Series Unit Equipment
  (1)(2)-(3)(4)-(5)(6)[9]
 
[9] (1) Color: Blank - White, or A to Z for other colors
    (2) Series:
        12SV24M - 12V-24W lead calcium
        12SV24N - 12V-24W nickel cadmium
        12SV36M - 12V-36W lead calcium
        12SV40N - 12V-40W nickel cadmium
        12SV54M - 12V-54W lead calcium
        12SV60H - 12V-40W Nickel metal hydride
        SV18M   - 6V-18W lead calcium
    (3) Number of heads: 2  - Two heads
    (4) Lamps: 
        LA to LZ - LED Lamp 6V or 12V Max 6W 
        MA to MZ - MR16 lamp 6V or 12V Max 20W
    (5) Charger: 
        D     - Autodiagnostic, 
        DA    - Autodiagnostic audible,
        NEX   - Nexus interface wired
        NEXRF - Nexus interface wireless
    (6) Options: 
        Blank                - No options, 
        CW4                  - Cold weather (only available
        with 12SV24M & 12SV36M, not with NEX)
        D1, D2, D3, D4 or D5 – 5, 10, 15, 20 or 30 minutes time delay

[1] NSF Certified production beginning with date code 49-99 (49 - week, 99 - year).

LIGHTALARMS BRAND[1]

ELF650 Series - Remote Unit
  ELF650(1)/(2)-(3)(4)[10]
 
[10] (1) Number of Heads: Blank - Single NEMA 4X, D - Double NEMA 4X
     (2) Lamps:
         LD1 to LD99              - LED lamp 6V, 12V or 24V, max 6W
         M1 to M99 or MH1 to MH99 - MR16 lamp 6V, 12V or 24V, max 20W
     (3) Color: A to Z
     (4) Voltage: 6 - 6V, 12 - 12V, 24 - 24V

Severe Series Unit Equipment
  (1)(2)-(3)(4)/(5)(6)[11]
 
[11] (1) Number of Heads: 2 - Two heads
     (2) Series
         VG1    - 6V-18W lead calcium
         V12G1  - 12V-24W lead calcium
         V12N1  - 12V-24W nickel cadmium
         V12G2  - 12V-36W lead calcium
         V12G3  - 12V-54W lead calcium
         V12H1  - 12V-40W nickel metal hydride
         V12N2  - 12V-40W nickel cadmium  
     (3) Lamps: 
         LD1 to LD99           - LED Lamp 6V or 12V Max 6W 
         M1 or MH1 to M99 MH99 - MR16 lamp 6V or 12V Max 20W    
     (4) Color: A to Z
     (5) Charger: 
         D     - Autodiagnostic 
         DA    - Autodiagnostic audible
         NEX   - Nexus interface wired
         NEXRF - Nexus interface wireless
     (6) Options: 
         Blank                - No options, 
         CW4                  - Cold weather (only available with V12G1 & V12G2, not with 
         NEX)
         T1, T2, T3, T4 or T5 – 5, 10, 15, 20 or 30 minutes time delay

Severe XV Series Exit Sign
  (1)(2)-(3)(4)/(5)(6)(7)[12]
 
[12] (1) Housing/Face Color: AA to ZZ
     (2) Series: XV - AC Only, XVE - Self powered nickel cadmium battery
     (3) Faces: 1 - Single face, 2 - Double face
     (4) Letter color: G - Green letters, R - Red letters
     (5) Diagnostics: 
         Blank - Standard, 
         D     - Diagnostics, 
         NEX   - Nexus interface wired (XVE only)
         NEXRF - Nexus interface wireless (XVE only)
     (6) Housing: 4X - NEMA 4X
     (7) Options:
         Blank - AC only
         1     - Flasher (AC power failure)
         2     - Dual Circuit (XV only)
         CW    - Cold Weather (available in single face, 6V-12W only)
         F     - Flasher (fire alarm activated)
         FB    - Flasher/buzzer (AC power failure - not available with
              "AD" option)
         W     - White LED
         DC    - 6-48 Vdc or 6-24 Vdc

XV Series Combo Unit
  (1)XV(2)(3)(4)(5)(6)/(7)(8)(9)[13]
 
[13] (1) Housing/face color AA to ZZ
     (2) Remote capacity: 12E - 6V-12W, 24E - 12V-24W
     (3) Faces: 1 - Single face, 2 - Double face
     (4) Letter color: G - Green letters, R - Red letters
     (5) Diagnostics: D  - Improved diagnostics – non-audible (standard),
         AD    - Improved diagnostics - audible
         NEX   - Nexus interface wired
         NEXRF - Nexus interface wireless
     (6) Housing: 4X - NEMA 4X
     (7) Number of heads: 0 - No heads, 2 - Two heads
     (8) Lamp/wattage: 
         LD1 to LD99 indicates LED lamp 6V or 12V max 6W
         M1 to M99 indicates MR16 lamp 6V or 12V max 12W
     (9) Options:
         CW4 - Cold weather (120/277V, available in single face only)
         CW1 - Cold weather (120V, available in single face only)
         CW2 - Cold weather (277V, available in single face only)
         FAF - Flasher (fire alarm activated)
         FB  - Flasher/buzzer
         FL  - Flasher (AC power failure)

[1] NSF Certified production beginning with date code 49-99 (49 - week, 99 - year).

LUMACELL BRAND[1]

3LER3000 Series Combo Unit
  (1)(2)(3)(4)(5)(6)(7)[14]
 
[14] (1) Series: 3LER3 - 6V-36W, NEMA 4X, 5LER3 - 12V-60W, NEMA 4X
     (2) Faces: 500 - Single face, 600 - Double face
     (3) Number of heads: Blank - No heads, 2 - 2 heads
     (4) Lamp/wattage:
         LD1 to LD99 - LED Lamp 6V or 12V, max 6W
         MA to MZ    - MR16 Lamp 6V or 12V, max 12W         
     (5) Housing/face color AA to ZZ
     (6) Voltage: 
         Blank - For CW1, CW2 or CW3, 
         ZC    - 120/277VAC, 
         ZD    - 120/347VAC
     (7) Options:
         Blank - Advanced diagnostics non audible
         AT    - Advanced diagnostics audible
         CW    - Cold weather 120/277V or 120/347V
         CW1   - Cold weather 120V
         CW2   - Cold weather 277V
         CW3   - Cold weather 347V
         GN    - Green letters
         NEX   - Nexus interface wired
         NEXRF - Nexus interface wireless

LER3000 Series Exit Sign
  LER3(1)(2)(3)(4)(5)[15]
 
[15] (1) Faces: 500 - Single face, 600 - Double face
     (2) Housing/face color AA to ZZ
     (3) Voltage: 
         Blank      - Universal 120-347 VAC, 6-48vdc, 
         W          - Universal 120-347 VAC, 6-24vdc (White LED)
         SPD        - 120-347 VAC self powered w/diagnostics,
         SPD2       – 120/277 VAC self powered w/diagnostics (White LED)
         SPD3       – 120/347 VAC self powered w/diagnostics (White LED) 
         120VACDC2  - 120VAC, 120vdc,
         120VACDC2W - 120VAC, 120vdc (White LED) 
         Nex        - Nexus interface wired 120-347VAC
         NEX2       - Nexus interface wired 120/277VAC (White LED)
         NEX3       - Nexus interface wired 120/347VAC (White LED)
         NEXRF2     - Nexus interface wireless 120/277VAC (White LED)
         NEXRF3     - Nexus interface wireless 120/347VAC (White LED)
     (4) Options: 
         GN - Green letters, 
         CW - Cold weather
     (5) Cabinet: 4X - NEMA 4X

LN Series Pictogram Sign
  LN(1)(2)(3)(4)(5)[25]
 
[25] (1) Faces:    
         1 - Single face   
         2 - Double face   
     (2) Arrow Configuration:   
         Blank - Standard   
         U9    - Arrow Up   
         D9    - Arrow Down   
         U4    - Arrow Up 45º   
         D4    - Arrow Down 45º   
     (3) Body color:  A to Z   
     (4) Voltage:   
         S     - 120-347 VAC self-powered   
         SD    - 120-347 VAC self-powered w/diagnostics   
         SD2   – 120/2777 VAC self-powered w/diagnostics   
         U     - Universal 120-347 VAC, 6-24vdc   
         U00   - Universal 120-347 VAC   
         U36   - Universal 120-347 VAC, 36vdc   
         U48   - Universal 120-347 VAC, 48vdc   
         U120  - Universal 120-347 VAC, 120vdc   
         2120  - 2-Wires 120 VAC, 120vdc   
         NEX   - Nexus interface wired 120/347Vac   
         NEXRF - Nexus interface wireless 120/347Vac   
     (5) Options:   
         Blank - No Option   
         CW    - Cold weather

LNC Series Pictogram Combo Unit
  LNC(1)(2)(3)(4)(5)(6)(7)[24]
 
[24] (1) Faces:    
         1 - Single face   
         2 - Double face   
     (2) Arrow Configuration:    
         Blank - Standard   
         U9    - Arrow Up   
         D9    - Arrow Down   
         U4    - Arrow Up 45º   
         D4    - Arrow Down 45º   
     (3) Housing/face color: A to Z   
     (4) Battery Type & Power:    
         6N36  - 6V-36W, Nickel-Cadmium   
         12N60 - 12V-60W, Nickel-Cadmium   
     (5) Lamps/wattage:    
         Blank – No lamp            
         LD1 to LD99 - LED Lamp 6V or 12V Max 6W   
         MA to MZ    - MR16 lamp 6V or 12V Max 12W   
     (6) Voltage:   
         Blank – 120/347VAC   
         ZC    – 120/277VAC   
     (7) Options:   
         Blank - Advanced diagnostics non audible   
         AT    - Advanced diagnostics audible   
         T3    - Time Delay 15 minutes   
         NEX   - Nexus interface wired   
         NEXRF - Nexus interface wireless
         CW    - Cold weather

MQM-NX Series - Remote Unit
  MQM(1)NX(2)(3)[16]
 
[16] (1) Number of heads: 1 - Single NEMA 4X, 2 - Double NEMA 4X
     (2) Lamp type/wattage:
         LD1 to LD99 - LED Lamp 6V, 12V, 24V or 120V, max 6W
         6VXXW       - MR16 Lamp 6V Max 20W
         12VXXW      - MR16 Lamp 12V Max 20W
         24VXXW      - MR16 Lamp 12V Max 20W
         120VXXW     - MR16 Lamp 120V Max 20W         
     (3) Color: A to Z

RG-NX Series Unit Equipment
  RG(1)NX(2)(3)(4)(5)(6)(7)(8)[17]
 
[17] (1) Voltage: Blank - 6V, 12 - 12V
     (2) Capacity: 36 - 6V-36W, 72 - 12V-72W, 108 - 12V-108W
     (3) Number of heads: 2 - Two heads
     (4) Lamps:
         LD1 to LD99 - LED Lamp 6V or 12V, max 6W
         M1W to M99W - MR16 Lamp 6V or 12V, max 20W
     (5) Color: A to Z
     (6) AC voltage: Blank - 120/347vac, ZC - 277vac
     (7) Charger: 
         Blank - Autodiagnostic 
         NEX   - Nexus interface wired
         NEXRF - Nexus interface wireless     
     (8) Options:
         Blank                - No options
         CW1                  - Cold Weather 120vac
         CW3                  - Cold Weather 347vac (available in 6V only)
         T1, T2, T3, T4 or T5 – 5, 10, 15, 20 or 30 minutes time delay

[1] NSF Certified production beginning with date code 49-99 (49 - week, 99 - year).

READY-LITE BRAND[1]

LDX Series Unit Equipment
  LDX(1)-(2)(3)(4)(5)(6)(7)(8)(9)[18]
 
[18] (1) Voltage: 6 - 6V, 12 - 12V
     (2) Capacity: 36 - 6V-36W, 72 - 12V-72W, 108- 12V-108W
     (3) Cabinet: NM - NEMA 4X
     (4) Number of heads: 2 - Two heads
     (5) Lamps:
         LD1 to LD99                     - Indicates LED lamp 6V or 12V, Max 6W
         RM1 to RM99 maybe suffixed by H - Indicates MR16 lamp 6V or 12V, 
         Max 20W
         6/XX   - Indicates MR16 lamp 6V, Max 20W
         12/XX  - Indicates MR16 lamp 12V, Max 20W
         24/XX  - Indicates MR16 lamp 12V, Max 20W
         120/XX - Indicates MR16 lamp 120V, Max 20W
     (6) Color: Blank - Factory white, or AA to ZZ
     (7) AC voltage: Blank - 120/347vac, U277 - 277vac
     (8) Charger: 
         Blank - Autodiagnostic 
         NEX   - Nexus interface wired
         NEXRF - Nexus interface wireless
     (9) Options:
         Blank                - No options
         CW1                  - Cold weather 120vac
         CW3                  - Cold weather 347vac (available in 6V only)
         D1, D2, D3, D4 or D5 – 5, 10, 15, 20 or 30 minutes time delay

N-TUF Series Combo Unit
  (1)(2)(3)(4)(5)(6)(7)[19]
 
[19] (1) Series: N12M60 - 12V-60W, NM36 - 6V-36W
     (2) Number of heads: Blank - No heads, 2 - 2 heads
     (3) Lamp/wattage: 
         LD1 to LD99 - LED lamp 6V or 12V, Max 6W
         MA to MZ    - MR16 lamp 6V or 12V, Max 12W
     (4) Faces: TUF1 - Single face, TUF2 - Double face
     (5) Housing/face color AA to ZZ:
     (6) Voltage: 
         Blank - For CW1, CW2 or CW3, 
         U277  - 120/277VAC, 
         U347  - 120/347VAC
     (7) Options:
         Blank - Advanced diagnostics non audible
         AD    - Advanced diagnostics audible
         CW    - Cold weather 120/277V or 120/347V
         CW1   - Cold weather 120V
         CW2   - Cold weather 277V
         CW3   - Cold weather 347V        
         G     - Green letters
         NEX   - Nexus Interface
         NEXRF - Nexus interface wireless

NM Series - Remote Unit
  NM(1)(2)-(3)(4)[20]
 
[20] (1) Lamp type: M - MR16
     (2) Number of heads: 1 - One, 2 - Two
     (3) Voltage/wattage:
         LD1 to LD99 - Indicates LED lamp 6V, 12V, 24V or 120V,
         Max 6W
     (4) Color: Blank - Factory white, BK - Black, GY – Gray

RN Series Pictogram Sign
  RN(1)(2)(3)(4)(5)[23]
 
[23] (1) Faces:   
         1 - Single face   
         2 - Double face 
     (2) Arrow Configuration:     
         Blank - Standard   
         U9    - Arrow Up   
         D9    - Arrow Down   
         U4    - Arrow Up 45º   
         D4    - Arrow Down 45º   
     (3) Body color:  A to Z   
     (4) Voltage:   
         SP    - 120-347 VAC self-powered   
         SPD   - 120-347 VAC self-powered w/diagnostics   
         SPD2  – 120/2777 VAC self-powered w/diagnostics   
         U     - Universal 120-347 VAC, 6-24vdc   
         U00   - Universal 120-347 VAC   
         U36   - Universal 120-347 VAC, 36vdc   
         U48   - Universal 120-347 VAC, 48vdc   
         U120  - Universal 120-347 VAC, 120vdc   
         2120  - 2-Wires 120 VAC, 120vdc   
         NEX   - Nexus interface wired 120/347Vac   
         NEXRF - Nexus interface wireless 120/347Vac   
     (5) Options:   
         Blank - No Option   
         CW    - Cold weather

RNC Series Pictogram Combo Unit
  RNC(1)(2)(3)(4)(5)(6)(7)[22]
 
[22] (1) Faces:    
         1 - Single face   
         2 - Double face   
     (2) Arrow Configuration:    
         Blank - Standard   
         U9    - Arrow Up   
         D9    - Arrow Down   
         U4    - Arrow Up 45º   
         D4    - Arrow Down 45º   
     (3) Housing/face color: A to Z   
     (4) Battery Type & Power:    
         6N36  - 6V-36W, Nickel-Cadmium   
         12N60 - 12V-60W, Nickel-Cadmium   
     (5) Lamps/wattage:    
         Blank       – No lamp            
         LD1 to LD99 - LED Lamp 6V or 12V Max 6W   
         MA to MZ    - MR16 lamp 6V or 12V Max 12W   
     (6) Voltage:   
         Blank – 120/347VAC   
         U2    – 120/277VAC   
     (7) Options:   
         Blank - Auto diagnostics non audible   
         AD    - Auto diagnostics audible   
         D3    - Time Delay 15 minutes   
         NEX   - Nexus interface wired   
         NEXRF - Nexus interface wireless   
         CW    - Cold weather

TUF Series Exit Sign
  TUF(1)(2)(3)(4)(5)(6)[21]
 
[21] (1) Faces: 1 - Single face, 2 - Double face
     (2) AC voltage: 
         Blank - 120VAC (For L120-2W and L120-2WW only), 
         U     - Universal 120-347 VAC
         2     - Universal 120/277 VAC (White LED)
         3     - Universal 120/347 VAC (White LED)
     (3) Housing/face color AA to ZZ
     (4) DC Voltage: 
         DC       - 6-48 vdc,
         DCW      – 6-24 vdc (White LED)
         W        – Universal 6-24 vdc (White LED)
         SPD      - 120-347VAC self power/diagnostics,
         SPDW     - 120-347VAC self power/diagnostics (White LED)
         L120-2W  - 120vdc,
         L120-2WW - 120vdc (White LED)
         NEX      - Nexus interface wired 
         NEXW     - Nexus interface wired (White LED)
         NEXRFW   - Nexus interface wireless (White LED)
     (5) Options:
         CW - Cold weather
         G  - Green letters
     (6) Cabinet: 4X - NEMA 4X

[1] NSF Certified production beginning with date code 49-99 (49 - week, 99 - year).


Facility : Zhejiang, China


Stainless Steel While in Use Enclosure
  SSE

COMPONENTS:

Ball Valve[1]
  FG-DA 3/8
 
[1] Interior surfaces are food zone, exterior surfaces are splash zone.

Drain Valve[1]
  DBV - 1/4
 
[1] Interior surfaces are food zone, exterior surfaces are splash zone.


Facility : Uster, Switzerland


COMPONENTS:

Polyamide Conduits PMA OXC Series[1]
  JFBDG-12C01
  JFBDG-17C01
  JFBDG-23C01
  JFBDG-29C01
  JFBDG-36C01
  JFBDG-48C01
 
[1] Approved for food zone non-contact.

Polyamide Fittings PMA OXC Series[2]
  JKBH-M162
  JKBH-M202
  JKBH-M207
  JKBH-M253
  JKBH-M257
  JKBH-M323
  JKBH-M329
  JKBH-M406
  JKBH-M409
  JKBH-M506
  JKBH-M508
  JKBH-M638
  JKNH-M162
  JKNH-M202
  JKNH-M207
  JKNH-M253
  JKNH-M257
  JKNH-M323
  JKNH-M329
  JKNH-M406
  JKNH-M409
  JKNH-M506
  JKNH-M508
  JKNH-M638
 
[2] Approved for use in splash and non-food zone.

Stainless Steel Fittings PMA OXC Series[1]
  JENQ-M162-10
  JENQ-M207-10
  JENQ-M253-11
  JENQ-M329-13
  JENQ-M406-13
  JENQ-M508-14
 
[1] Approved for food zone non-contact.


Number of matching Manufacturers is 1