NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 1, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=169&Company=C0144789&
NSF/ANSI 169
Special Purpose Food Equipment and Devices
Special Purpose Food Equipment and Devices
| AVS Römer GmbH & Co. KG | |
| Werk Grafenau | |
| Reismühle 3 | |
| 94481 Grafenau | |
| Germany | |
| 49 817 992 610 | |
| Visit this company's website |
Facility : Grafenau, Germany
|
COMPONENTS: |
|
|
External Gear Pump EGP Series[1] [Pb] |
|
| EGP(1)-X4(2)(3)-P4(4)A-(5)(6)(7)(6)(8)-(9)-(10) | |
[1] (1) One number to identify rinsing concept: 1, 2, 3…
(2) One character to localise body connection: S, V, U
(3) One character to identify connection sealing type: O, D, F
(4) Three numbers to identify flow rate: 050, 060, 080, 110
(5) One character and/or one number to identify connection material: 0, P3, X4
(6) One character to describe connection type: E, R, D, G, T, F
(7) 2 digits number to describe connection size: 18, 44, 66, 64, 88, 86
(8) Two character to identify sealing material and type: FF, PF, PZ
(9) Up to 5 possible digits to describe electrical customization
(10) Optional S (XXX) numbering of customer specific version.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Flowcontrol and Check Valve from PPSU[2] [Pb] |
|
| AFO-9(2)-P3(9)-(3)-(3)(8)-(4)-S(10) | |
| FFO-9(2)P3-(3)-(3)-(3)(8)-(4)-(5)-S(10) | |
| MFV-9(2)-P3(9)-(3)-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
| RFO-9(2)-P3(9)-(3)-(3)(8)-(4)-S(10) | |
| SMF-9(2)P3-(3)-(3)(8)-(4)-(7)-S(10) | |
| SVK(1)-9(2)-P3(9)-(3)-(3)(8)-(4)-S(10) | |
| UDV-9(2)P3-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
| VNR(1)-9(2)-P3(9)-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
| VRN(1)-9(2)-P3(9)-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
[2] (1) 1-2 digits indicate a special version, e.g spring position
(2) 2 digits indicate fitting type
(3) 1-4 digits indicate push-in connector size; multiple entries are not
applicable for the same size
(4) Up to 8 digits indicate the thread size and type, stem connector, hosetail
or bayonet; omitted if only push-in connection
(5) 3-4 digits indicate throttle
(6) 3 digits indicate opening pressure; not applicable at 0.1 bar
(7) Up to 5 digits indicate the mesh size and material
(8) Sealing material:
FF - FPM
FR - FPM
FT - FPM
PF - EPDM
QF - VMQ
QFF - FPM + VMQ
QPF - EPDM + VMQ
QFT - FPM + VMQ
QPT - EPDM + VMQ
(9) 2 digits indicate nominal diameter
(10) Optional S (+1-2 digits) indicate a specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Flowcontrol and Check Valve from Stainless Steel[3] [Pb] |
|
| VNR(1)-(2)(3)-X4(4)-(5)-(5)(6)-(7)-(8)-(9) | |
| VRN-(2)(3)-X4(4)-(5)-(5)(6)-(7)-(8)-(9) | |
[3] (1) optional 1 digit indicates special valve type
(2) 1: push-on fitting; 9: push-in fitting
(3) 2 digits indicate fitting type
(4) 2 digits indicate nominal diameter, e.g. DN4 (40)
(5) 1-4 digits indicate push-in/on connector size;
multiple entries are not applicable for the same size
(6) Sealing material: FF, PF, PZ, QF, QFF, QPF, QPZ
(7) optional up to 8 digits indicate connection size and type, e.g. thread, stem
connector
(8) 3 digits indicate opening pressure; not applicable at 0.1 bar
(9) optional S(+1-2 digits) indicate a specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Flowcontrol and check valves from PVDF[4] [5] [Pb] |
|
| TTV-958-V(1)-(2)(3)-(4) | |
[4] (1) 2 digits indicating nominal diameter: DN0,5 (05) DN1 (10) DN1,5 (15) DN2
(20), DN2,5 (25) DN3 (30), DN3,5 (35) DN4 (40) DN4,5 (45) DN5 (50)
(2) Digits indicating plug connection diameter, between 4 and 8 and 1/4"
(3) O-ring material:
FF - FKM black
FR - FKM red
PF - HITEC EPDM
PZ - EPDM
QF - Silicone
QFF - FKM black + silicone
QFR - FKM red + silicone
QPF - Hitec EPDM + silicone
QPZ - EPDM + Silicone
(4) Optional: S (X) numbering of customer specific version, where X ranges from
01 to 999
[5] For use in contact with coffee, tea and water only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Measurement and control - Electronic flow control valve[6] [Pb] |
|
| EFC-(I)-(1)(2)(3)(J)-(4)-(4)(5)-(K)-(6) | |
[6] (1) Up to 2 digits indicate series (1 - Push-On, 9 - Push-In, FL - sub-base)
(2) 2 digits indicate fitting type and optional sub-base type
(3) Body Material P3, V
(4) 1-4 digits indicate stem connector, hose tail, push-in connector size; multiple
entries are not applicable for the same size
(5) Sealing Material FF, FR, PF, PZ, QF
(6) Optional 2 digits indicate cable length incl. supply connection or S (+1-3 digits)
indicate a specific version
(7) Up to 2 digits indicate variant vs. undefined digits for customer specific
variant
(A) Up to 3 digits indicate sensor size and sleeve material
(B) 3-4 digits indicate measuring range start
(C) 3 digits indicate measuring range end
(D) Up to 5 digits indicate output signal, e.g. U05/I
(E) 2 digits indicate supply voltage
(F) 3 digits indicate default or vacuum type incl. pressure nominal, e.g. V04
(G) Sensor housing material X01, X04 – not applicable for ceramic housing
(H) Sensor type, e.g. PT100 , NTC10, …
(I) 2-3 digits indicate type of motor, type of electronic and/or customer specific
variant
(J) 2 digits indicate nominal diameter; e.g. DN0,5 (05) or DN5 (50)
(K) Up to 5 digits indicate control signal
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Measurement and control - Plug-in Sensors[7] [Pb] |
|
| BPS-(1)(2)-(3)-(3)(4)-(5)(6)-(11) | |
| XLS-(1)(2)-(3)-(3)(4)-(5)(6)-(7)-(9)-(10)-(11) | |
| XTL-(1)(2)-(3)-(3)(4)-(5)(6)-(7)-(8)-(9)-(10)-(11) | |
| XTS-(1)(2)-(3)-(3)(4)-(5)(6)-(7)-(8)-(9)-(10)-(11) | |
[7] (1) Optional 3 digits indicate fitting type
(2) Optional 2-4 digits indicate the material: P3 (PPSU), P5 (PEEK), X4 (1.4404), X5
(1.4305)
(3) 1-4 digits indicate push-in connector size; multiple entries are not applicable for
the
same size
(4) Optional 1-2 digits indicate the sealing material
FF = FKM
PF = EPDM
QF = VMQ
(5) Optional up to 8 digits indicate the thread size and type
(6) Optional 1-3 digits indicate the thread material (stainless steel)
(7) 2-3 digits indicate the sensor material (stainless steel)
(8) 2-8 digits indicate the type of sensor
(9) 2-6 digits indicate the sleeve length
(10) 2-4 digits indicate the cable length
(11) Optional S (+1-3 digits) indicate a specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Measurement and control - Temperature sensor[6] [Pb] |
|
| ITS-(1)(2)(3)-(4)-(4)(5)-(G)-(H)-(6) | |
| ITS-(7)-(1)(2)(3)-(4)-(4)(5)-(G)-(H)-(6) | |
[6] (1) Up to 2 digits indicate series (1 - Push-On, 9 - Push-In, FL - sub-base)
(2) 2 digits indicate fitting type and optional sub-base type
(3) Body Material P3, V
(4) 1-4 digits indicate stem connector, hose tail, push-in connector size; multiple
entries are not applicable for the same size
(5) Sealing Material FF, FR, PF, PZ, QF
(6) Optional 2 digits indicate cable length incl. supply connection or S (+1-3 digits)
indicate a specific version
(7) Up to 2 digits indicate variant vs. undefined digits for customer specific
variant
(A) Up to 3 digits indicate sensor size and sleeve material
(B) 3-4 digits indicate measuring range start
(C) 3 digits indicate measuring range end
(D) Up to 5 digits indicate output signal, e.g. U05/I
(E) 2 digits indicate supply voltage
(F) 3 digits indicate default or vacuum type incl. pressure nominal, e.g. V04
(G) Sensor housing material X01, X04 – not applicable for ceramic housing
(H) Sensor type, e.g. PT100 , NTC10, …
(I) 2-3 digits indicate type of motor, type of electronic and/or customer specific
variant
(J) 2 digits indicate nominal diameter; e.g. DN0,5 (05) or DN5 (50)
(K) Up to 5 digits indicate control signal
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Measurement and control - conductivity sensor[6] [Pb] |
|
| ICS-(1)(2)(3)-(4)-(4)(5)-(B)-(C)-(D)-(6) | |
| ICS-(7)-(1)(2)(3)-(4)-(4)(5)-(B)-(C)-(D)-(6) | |
| XCS-(7)-(1)(2)(3)-(A)-(4)-(4)(5)-(B)-(C)-(D)-(6) | |
[6] (1) Up to 2 digits indicate series (1 - Push-On, 9 - Push-In, FL - sub-base)
(2) 2 digits indicate fitting type and optional sub-base type
(3) Body Material P3, V
(4) 1-4 digits indicate stem connector, hose tail, push-in connector size; multiple
entries are not applicable for the same size
(5) Sealing Material FF, FR, PF, PZ, QF
(6) Optional 2 digits indicate cable length incl. supply connection or S (+1-3 digits)
indicate a specific version
(7) Up to 2 digits indicate variant vs. undefined digits for customer specific
variant
(A) Up to 3 digits indicate sensor size and sleeve material
(B) 3-4 digits indicate measuring range start
(C) 3 digits indicate measuring range end
(D) Up to 5 digits indicate output signal, e.g. U05/I
(E) 2 digits indicate supply voltage
(F) 3 digits indicate default or vacuum type incl. pressure nominal, e.g. V04
(G) Sensor housing material X01, X04 – not applicable for ceramic housing
(H) Sensor type, e.g. PT100 , NTC10, …
(I) 2-3 digits indicate type of motor, type of electronic and/or customer specific
variant
(J) 2 digits indicate nominal diameter; e.g. DN0,5 (05) or DN5 (50)
(K) Up to 5 digits indicate control signal
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Measurement and control -Pressure sensor[6] [Pb] |
|
| IPS-(7)-V(E)-(1)(2)(3)-(4)-(4)(5)-(F)-(6) | |
| IPS-V(E)-(1)(2)(3)-(4)-(4)(5)-(F)-(6) | |
[6] (1) Up to 2 digits indicate series (1 - Push-On, 9 - Push-In, FL - sub-base)
(2) 2 digits indicate fitting type and optional sub-base type
(3) Body Material P3, V
(4) 1-4 digits indicate stem connector, hose tail, push-in connector size; multiple
entries are not applicable for the same size
(5) Sealing Material FF, FR, PF, PZ, QF
(6) Optional 2 digits indicate cable length incl. supply connection or S (+1-3 digits)
indicate a specific version
(7) Up to 2 digits indicate variant vs. undefined digits for customer specific
variant
(A) Up to 3 digits indicate sensor size and sleeve material
(B) 3-4 digits indicate measuring range start
(C) 3 digits indicate measuring range end
(D) Up to 5 digits indicate output signal, e.g. U05/I
(E) 2 digits indicate supply voltage
(F) 3 digits indicate default or vacuum type incl. pressure nominal, e.g. V04
(G) Sensor housing material X01, X04 – not applicable for ceramic housing
(H) Sensor type, e.g. PT100 , NTC10, …
(I) 2-3 digits indicate type of motor, type of electronic and/or customer specific
variant
(J) 2 digits indicate nominal diameter; e.g. DN0,5 (05) or DN5 (50)
(K) Up to 5 digits indicate control signal
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Push-In and Push-On Fittings and Fittings Accessories from Metal[8] [Pb] |
|
| 121(B)-(3)(M)-(2)(A)-S(X) | |
| 130(B)-(3)(M)-(2)(A)-S(X) | |
| 141(B)-(3)(M)-(2)-S(X) | |
| 142(B)-(3)(M)-(2)-S(X) | |
| 150(B)-(3)(M)-(2)-S(X) | |
| 151(B)-(3)(M)-(2)(A)-S(X) | |
| 154(B)-(3)(M)-S(X) | |
| 155(B)-(3)(M)-S(X) | |
| 202(B)-(2)(A)-(2)-S(X) | |
| 250(B)-(2)(A)-S(X) | |
| 251(B)-(2)-(2)(A)-S(X) | |
| 252(B)-(2)(A)-(2)-S(X) | |
| 253(B)-(2)(A)-(2)-S(X) | |
| 254(B)-(2)-S(X) | |
| 255(B)-(2)-(2)-S(X) | |
| 260(B)-(1)-(2)(A)-S(X) | |
| 262(B)-(2)(A)-S(X) | |
| 904(B)-D(1)-D(1)-S(X) | |
| 908(B)-(1)(A)-(2)-S(X) | |
| 909(B)-(1)(A)-(2)-S(X) | |
| 911(B)-(1)(A)-D(1)-S(X) | |
| 912(B)-(1)-(1)(A)-D(1)-S(X) | |
| 921(B)-(1)-(1)(A)-(2)-S(X) | |
| 922(B)-(1)-(1)(A)-(2)-S(X) | |
| 930(B)-(1)(A)-(2)-S(X) | |
| 941(B)-(1)-(1)-(A)-(2)-S(X) | |
| 945(B)-(1)(A)-(2)-S(X) | |
| 946(B)-(1)(A)-(2)-S(X) | |
| 947(B)-(1)(A)-D(1)-S(X) | |
| 949(B)-(1)(A)-(2)-S(X) | |
| 950(B)-(1)(A)-(2)-S(X) | |
| 951(B)-(1)(A)-(2)-S(X) | |
| 954(B)-(1)-(1)-(1)(A)-S(X) | |
| 955(B)-(1)-(1)(A)-S(X) | |
| 958(B)-(1)-(1)(A)-S(X) | |
| 959(B)-(1)-(1)(A)-S(X) | |
| 971(B)-D(1)-S(X) | |
| 973(B)-(1)(A)-(C)-(D)-S(X) | |
| 973MB-(1)(A)-(C)-(D)-S(X) | |
| 975(B)-(1)(A)-(C)-(D)-S(X) | |
| 975MB-(1)(A)-(C)-(D)-S(X) | |
| 976(B)-(1)(A)-S(X) | |
| 979(B)-(1)(A)-(2)-S(X) | |
| 982(B)-(1)-(1)-(1)(A)-S(X) | |
| 992(B)-(1)-(1)(A)-(2)-S(X) | |
[8] (1) 1-4 digits indicate stem connector, hose tail or push-in connector size;
multiple entries are not applicable for the same size
(2) Up to 8 digits indicate the thread size and type
(3) 3-7 digits indicate Rapid connection
(A) Optional sealing material: FF, FT = FPM; PF = EPDM; QF = VMQ
(B) Body: X4, X44, X4M, X44M = 1.4404; X5, X54= 1.5305
(C) 1-2 digits indicate release button material
(D) Release button colour
(M) Appendix in case of union nut made of brass (no food contact)
S(X) Optional: indicates customer specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Push-in-Fittings from PK[9] [Pb] |
|
| 908PK-(1)(3)-(2)-(4) | |
| 911PK-(1)(3)-D(1)-(4) | |
| 912PK-(1)-(1)(3)-D(1)-(4) | |
| 921PK-(1)-(1)(3)-(2)-(4) | |
| 922PK-(1)-(1)(3)-(2)-(4) | |
| 923PK-(1)-(1)(3)-(2)-(4) | |
| 930PK-(1)(3)-(2)-(4) | |
| 930PK-(1)(3)-(2)-(4) | |
| 946PK-(1)(3)-(2)-(4) | |
| 951PK-(1)(3)-(2)-(4) | |
| 954PK-(1)-(1)-(1)(3)-(4) | |
| 955PK-(1)-(1)(3)-(4) | |
| 958PK-(1)-(1)(3)-(4) | |
| 970PK-(1)-(1)(3)-(2)-(4) | |
| 979PK-(1)(3)-(2)-(4) | |
| 982PK-(1)-(1)-(1)(3)-(4) | |
| 992PK-(1)-(1)(3)-(2)-(4) | |
| 993PK-(1)-(1)(3)-(2)-(4) | |
[9] (1) 1-3 digits indicate stem connector, hose tail or push-in connector size; multiple
entries are not applicable for the same size
(2) Up to 10 digits indicate the thread size, type and material
(3) Sealing material: FT - FKM, PT - EPDM
(4) Optional: S followed by digits/numbers, indicates customer specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Push-in-Fittings from PPSU [10] [Pb] |
|
| 240P3-(1)-(3)(2)-(4) | |
| 272P3-(1)(2)-(3)-(4) | |
| 904P3-D(1)-D(1)-(4) | |
| 905P3-(1)(2)-(1)-(4) | |
| 907P3-D(1)-(1)-(4) | |
| 911P3-(1)(2)-D(1)-(4) | |
| 912P3-(1)-(1)(2)-D(1)-(4) | |
| 913P3-(1)-(1)(2)-D(1)-(4) | |
| 915P3-D(1)-D(1)-(4) | |
| 916P3-D(1)-D(1)-D(1)-(4) | |
| 921P3-(1)-(1)(2)-(3)-(4) | |
| 922P3-(1)-(1)(2)-(3)-(4) | |
| 923P3-(1)-(1)(2)-(3)-(4) | |
| 930P3-(1)(2)-(3)-(4) | |
| 947P3-(1)(2)-D(1)-(4) | |
| 951P3-(1)(2)-(3)-(4) | |
| 953P3-(1)(2)-(3)-(4) | |
| 954P3-(1)-(1)-(1)(2)-(4) | |
| 955P3-(1)-(1)(2)-(4) | |
| 958P3-(1)-(1)(2)-(4) | |
| 959P3-(1)-(1)(2)-(4) | |
| 960P3-(1)-(1)-(1)-(1)(2)-(4) | |
| 962P3-(1)-(1)-(1)-(1)-(1)-(1)-(1)(2)-(5)-(6)-(4) | |
| 970P3-(1)-(1)(2)-(3)-(4) | |
| 971P3-D(1)-(4) | |
| 979P3-(1)(2)-(3)-(4) | |
| 982P3-(1)-(1)-(1)(2)-(4) | |
| 984P3-(1)-(1)-(1)-(1)-(1)(2)-(4)[10] | |
| 985P3-(1)-(1)-(1)-(1)-(1)(2)-(4) | |
| 992P3-(1)-(1)(2)-(3)-(4) | |
| 993P3-(1)-(1)(2)-(3)-(4) | |
| ZLV-P3/(1)-(1)(2)-D(1)-(4) | |
[10] (1) 1-4 digits indicate stem connector, hose tail, push-in connector size or number of
inlets/outlets
(2) Sealing material: FF, FR, FT, PF, PT, PZ, QF
(3) Up to 8 digits indicate the thread size and type
(4) Optional S (+1-3 digits) indicate a specific version
(5) 1 digit indicate connection type
(6) optional 1 digit indicate installation type
[10] (1) 1-4 digits indicate stem connector, hose tail, push-in connector size or number of
inlets/outlets
(2) Sealing material: FF, FR, FT, PF, PT, PZ, QF
(3) Up to 8 digits indicate the thread size and type
(4) Optional S (+1-3 digits) indicate a specific version
(5) 1 digit indicate connection type
(6) optional 1 digit indicate installation type
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Push-in-Fittings from PVDF[11] [Pb] |
|
| 911V-(1)(3)-D(1)-(4) | |
| 912V-(1)-(1)(3)-D(1)-(4) | |
| 921V-(1)-(1)(3)-(2)-(4) | |
| 922V-(1)-(1)(3)-(2)-(4) | |
| 923V-(1)-(1)(3)-(2)-(4) | |
| 930V-(1)(3)-(2)-(4) | |
| 945V-(1)(3)-(2)-(4) | |
| 954V-(1)-(1)-(1)(3)-(4) | |
| 955V-(1)-(1)(3)-(4) | |
| 958V-(1)-(1)(3)-(4) | |
| 959V-(1)-(1)(3)-(4) | |
| 961V-(1)(3)-(2)-(4) | |
| 970V-(1)-(1)(3)-(2)-(4) | |
| 971V-D(1)-(4) | |
| 972V-(1)(3)-(4) | |
| 979V-(1)(3)-(2)-(4) | |
| 982V-(1)-(1)-(1)(3)-(4) | |
| 984V-(1)-(1)-(1)-(1)-(1)(3)-(4) | |
| 992V-(1)-(1)(3)-(2)-(4) | |
| 993V-(1)-(1)(3)-(2)-(4) | |
[11] (1)1-3 digits indicate stem connector, hose tail or push-in connector size multiple
entries are not applicable for the same size
(2) Up to 8 digits indicate the thread size and type
(3) Sealing material: FF, FR, PF, PZ, QF
(4) Optional S (+1-3 digits) indicate a specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Push-in-Fittings from Stainless Steel[12] [Pb] |
|
| 121(B)-(3)(M)-(2)(A)-S(X) | |
| 130(B)-(3)(M)-(2)(A)-S(X) | |
| 141(B)-(3)(M)-(2)-S(X) | |
| 142(B)-(3)(M)-(2)-S(X) | |
| 150(B)-(3)(M)-(2)-S(X) | |
| 151(B)-(3)(M)-(2)(A)-S(X) | |
| 154(B)-(3)(M)-S(X) | |
| 155(B)-(3)(M)-S(X) | |
| 202(B)-(2)(A)-(2)-S(X) | |
| 250(B)-(2)(A)-S(X) | |
| 251(B)-(2)-(2)(A)-S(X) | |
| 252(B)-(2)(A)-(2)-S(X) | |
| 253(B)-(2)(A)-(2)-S(X) | |
| 254(B)-(2)-S(X) | |
| 255(B)-(2)-(2)-S(X) | |
| 260(B)-(1)-(2)(A)-S(X) | |
| 262(B)-(2)(A)-S(X) | |
| 904(B)-D(1)-D(1)-S(X) | |
| 907(B)-D(1)-(1)-S(X) | |
| 908(B)-(1)(A)-(2)-S(X) | |
| 909(B)-(1)(A)-(2)-S(X) | |
| 911(B)-(1)(A)-D(1)-S(X) | |
| 912(B)-(1)-(1)(A)-D(1)-S(X) | |
| 921(B)-(1)-(1)(A)-(2)-S(X) | |
| 922(B)-(1)-(1)(A)-(2)-S(X) | |
| 930(B)-(1)(A)-(2)-S(X) | |
| 941(B)-(1)-(1)-(A)-(2)-S(X) | |
| 945(B)-(1)(A)-(2)-S(X) | |
| 946(B)-(1)(A)-(2)-S(X) | |
| 947(B)-(1)(A)-D(1)-S(X) | |
| 949(B)-(1)(A)-(2)-S(X) | |
| 950(B)-(1)(A)-(2)-S(X) | |
| 951(B)-(1)(A)-(2)-S(X) | |
| 954(B)-(1)-(1)-(1)(A)-S(X) | |
| 955(B)-(1)-(1)(A)-S(X) | |
| 958(B)-(1)-(1)(A)-S(X) | |
| 959(B)-(1)-(1)(A)-S(X) | |
| 971(B)-D(1)-S(X) | |
| 973(B)-(1)(A)-(C)-(D)-S(X) | |
| 973MB-(1)(A)-(C)-(D)-S(X) | |
| 975(B)-(1)(A)-(C)-(D)-S(X) | |
| 975MB-(1)(A)-(C)-(D)-S(X) | |
| 976(B)-(1)(A)-S(X) | |
| 979(B)-(1)(A)-(2)-S(X) | |
| 982(B)-(1)-(1)-(1)(A)-S(X) | |
| 992(B)-(1)-(1)(A)-(2)-S(X) | |
[12] (1) 1-4 digits indicate stem connector, hose tail or push-in connector size;
multiple entries are not applicable for the same size
(2) Up to 8 digits indicate the thread size and type
(3) 3-7 digits indicate Rapid connection
(A) Optional sealing material
FF, FT - FPM
PF - EPDM
QF - VMQ
(B) Body - X4, X44, X4M, X44M - 1.4404; X5, X54 - 1.4305
(C) 1-2 digits indicate release button material
(D) Release button colour
(M) Appendix in case of union nut made of brass (no food contact)
S(X) Optional - Indicates customer specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Solenoid valves - EAV and FPV series[13] [Pb] |
|
| EAV-(1)(2)(12)-(3)(4)-(5)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
| EAV-711(2)-(3)(4)-(5)-(5)(6)(7)(8)-(9)-(10)[14] | |
| EAV-811(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[14] | |
| EAV-S(11)(2)(12)-(3)(4)-(5)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
| EAV-S7(13)1-(2)-(3)(4)-(5)-(5)(6)(7)(8)-(9)-(10)[14] | |
| EAV-S8(13)1-(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[14] | |
| EAV-S90(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[16] | |
| EAV-S91(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[14] | |
| FPV-(1)(2)(12)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
| FPV-S(11)(2)(12)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
[13] (1) 3 digits indicate the series and version.
(2) Optional 2-4 digits indicate the material: X4, X4M, X44M = 1.4404; X5 = 1.4305; P3 =
PPSU.
(3) 1 digit indicates the function.
(4) 2 digits indicate the nominal diameter.
(5) 1-3 digits indicate the connection; multiple entries are not applicable for the same
size. All connections are certified.
(6) 2 digits indicate the sealing material: PF = EPDM; FF = FPM.
(7) Optional 1 digit indicates the hexagonal plunger.
(8) Optional S (+1-2 digits) indicate a specific version that does not impact
certification.
(9) Optional 4-5 digits indicate the voltage and current.
(10) 2-3 digits indicate the solenoid coil; 00 = partial solenoid valve without solenoid
coil.
(11) 2-3 digits indicate a specific version that does not impact certification.
(12) Optional / + 1-2 digits indicate a battery version.
(13) digit 1-99 indicates specific version that does not impact certification
[14] Only acceptable for use in contact with non-carbonated, potable water under constant
service pressure.
[16] For use in contact with coffee, tea and water only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Solenoid valves - ETV and ELV[15] [Pb] |
|
| ELV-(1)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
| ELV-2S(8)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
| ELV-S(8)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
| ETV-(1)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
| ETV-2S(8)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
| ETV-S(8)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
[15] (1) 3 digits indicate the series and version
(2) 1 digit indicates the function
(3) 2 digits indicate the nominal diameter
(4) 1-3 digits indicate the connection type and size or flange version; multiple
entries are not applicable for the same size
(5) 2 digits indicate the sealing material
(6) 5-6 digits indicate the voltage and current
(7) 2 digits indicate the solenoid coil
(8) 2-3 digits indicate a specific version
(9) Optional 4-5 digits indicate a battery version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Ultrasonic Flow Sensor - Measurement and Control[17] [Pb] |
|
| IFS-(1)-994P3-(2)-(3)(4)-(5)-(6)-(7)/(8)-(9) | |
[17] (1) 1-2 digits indicate version
(2) 1-2 digits indicate calibrated medium
(3) 1-3 digits indicate connection size
(4) 2 digits indicate sealing material: FF, FT - FPM; PF, PT, PZ - EPDM; QF - VMQ
(5) 1-4 digits indicate start of measuring range
(6) 1-5 digits indicate end of measuring range
(7) 3-5 digits indicate analog output signal analog / digital
(8) 1-5 digits indicate digital output signal analog / digital
(9) Optional S (+ 1-3 digits) indicate a specific version
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
Number of matching Manufacturers is 1
Number of matching Products is 203
Processing time was 0 seconds