NSF Product and Service Listings

These NSF Official Listings are current as of Sunday, December 08, 2019 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Lead_Content/Listings.asp?Standard=372%2DADD&Company=11390&


NSF/ANSI 372
Drinking Water System Components - Lead Content



 
Ames Fire & Waterworks, a Watts Regulator Co. 
1485 Tanforan Avenue
Woodland, CA 95776 
United States 
530-666-2493

Facility : Woodland, CA


Backflow Preventers [LL]
   2000SS-(X) 2.5" - 12"[1]
   4000SS-(X) 2.5" - 10"[1]
   Colt [LFC300-X]-YY-ZZ-WW-TT 2.5" - 10"[3]
   Colt [LFC500-X]-YY-ZZ-WW-TT 2.5" - 10"[3]
   LF3000SS-(X) 2.5" - 12"[1]
   LF5000SS-(X) 2.5" - 6"[1]
   Maxim [LFM300-X]-YY-ZZ-WW-TT 2.5" - 10"[3]
   Maxim [LFM500-X]-YY-ZZ-WW-TT 2.5" - 10"[3]

[1] Sizes: 2.5" - 12"
    
    Suffixes:
    DNRS - Domestic Non Rising Stem Gate
    DOSY - Domestic Observable Stem and Yoke Gate
    NRS  - Non Rising Stem Gate
    OSY  - Observable stem and yoke gate
    CFM is the output of the water meter in cubic feet per minute
    GPM is the output of the water meter in gallons per minute
    
[3] X - Valve pattern
        Blank - Straight
        N - N pattern
        Z - Z pattern
    YY - Backflow shutoff designation where 2 per units may be mixed like NRS x PIV 
         BFG  - Butterfly valve
         DNRS - Domestic non-rising stem gate
         DOSY - Domestic outside stem and yoke gate
         DPIV - Domestic post indicator gate
         NRS  - Non-rising stem gate
         OSY  - Outside stem and yoke gate
         PIV  - Post indicator gate
         QT   - Quarter turn ball valve
    ZZ - Inlet and outlet connections
         Blank - Flange by flange
         FxG - Flange by groove
         GxF - Groove by flange
         GxG - Groove by groove
    WW - By-pass meter option 
         C  - Cubic feet per minute
         G  - Gallons per minute
         LM - Less meter
    TT - Strainer options
         Blank - No strainer
         S     - 77F-DI-FDA-125 strainer
         S-SS  - Stainless strainer 8000-F
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Strainer[LL]
   10" 7002 2CO FLGxFLG
   10" 7002 2CO GRVxGRV
   10" 8000-F
   10" 8000-G
   12" 8000-F
   12" 8000-G
   2 1/2" 8000-F
   2 1/2" 8000-G
   3" 7001 1CO FLGxFLG
   3" 7001 1CO GRVxGRV
   3" 7002 2CO FLGxFLG
   3" 7002 2CO GRVxGRV
   3" 8000-F
   3" 8000-G
   4" 7001 1CO FLGxFLG
   4" 7001 1CO GRVxGRV
   4" 7002 2CO FLGxFLG
   4" 7002 2CO GRVxGRV
   4" 8000-F
   4" 8000-G
   5" 8000-F
   5" 8000-G
   6" 7001 1CO FLGxFLG
   6" 7001 1CO GRVxGRV
   6" 7002 2CO FLGxFLG
   6" 7002 2CO GRVxGRV
   6" 8000-F
   6" 8000-G
   8" 7001 1CO FLGxFLG
   8" 7001 1CO GRVxGRV
   8" 7002 2CO FLGxFLG
   8" 7002 2CO GRVxGRV
   8" 8000-F
   8" 8000-G

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Valves [LL]
   Classic Automatic Control Valve 1.5" - 16"[2]
   Mustang Automatic Control Valve 1.5" - 16"[2]
   Star Automatic Control Valve 1.5" - 16"[2]

[2] The following accessories are approved for use with the above valve: 263SS Pressure
    Reducing Control, F53 Flow Limiter, F51 Micro Switch, Stainless Swing Check Valve, F27
    Altitude Control Pilot, F60 Strainer Assembly, F50 Position Indicator, CP-16 Stainless
    Steel Relief Pilot, CP-15 Stainless Steel Relief Pilot, PV20SS Relief Pilot, F22
    Stainless Steel Accelerator, CP-14 Rate of Flow, F51 SI Scale Indicator, and F10-13
    Float Pilot.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Number of matching Manufacturers is 1
Number of matching Products is 45
Processing time was 0 seconds