NSF/ANSI 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities



 
ProMinent GmbH 
Im Schuhmachergewann 5-11
69123 Heidelberg 
Germany 
49 6221 842 0
Visit this company's website

Facility : Blovice, Czech Republic

Ultraviolet Light Process Equipment
Trade Designation Maximum
Flow Rate
(gpm)
Disinfection End Use

UV Generators[1] [2]
Dulcodes 1x0,65 S[3] [4] 75 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x1 A[3] [4] 245 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x1 S[3] [4] 225 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x2 A[3] [4] 418 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x2 S [3] [4] 392 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x230 LP[5] [6] 141 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x3 A[3] [4] 794 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x3 S[3] [4] 779 Supplemental Pool or Spa/Hot Tub
Dulcodes 1x350 LP[5] [6] 198 Supplemental Pool or Spa/Hot Tub
Dulcodes 2x2 A[3] [4] 1059 Supplemental Pool or Spa/Hot Tub
Dulcodes 2x2 S[3] [4] 1057 Supplemental Pool or Spa/Hot Tub
Dulcodes 2x3 A[3] [4] 1588 Supplemental Pool or Spa/Hot Tub
Dulcodes 2x3 S[3] [4] 1453 Supplemental Pool or Spa/Hot Tub
Dulcodes 2x350 LP[5] [6] 458 Supplemental Pool or Spa/Hot Tub
Dulcodes 3x230 LP[5] [6] 387 Supplemental Pool or Spa/Hot Tub
Dulcodes 3x3 A[3] [4] 2382 Supplemental Pool or Spa/Hot Tub
Dulcodes 3x3 S [3] [4] 2202 Supplemental Pool or Spa/Hot Tub
Dulcodes 3x350 LP[5] [6] 809 Supplemental Pool or Spa/Hot Tub

[1] This product has not been Certified by NSF to the requirements of the National
    Electrical Code or electrical product safety standards.
[2] Product has met the requirements of NSF/ANSI 50, Annex H.1: Disinfection Efficacy for
    the >= 3 log reduction of Enterococcus faecium [ATCC #6569] and Pseudomonas aeruginosa
    [ATCC #27313]. This product is intended for supplemental disinfection and should be used
    with registered or approved disinfection chemicals to impart residual concentrations in
    accordance with state and local regulations. This product has not been evaluated to the
    cryptosporidium inactivation requirements of NSF/ANSI 50.
[3] Dulcodes Series A UV systems have electronic ballast(s) and variable power supply.
    Dulcodes Series S UV systems have electromagnetic ballast(s).
[4] UV systems are medium pressure UV lamp type with metal reactor vessel and either manual
    wiper or automated wiper cleaning system.
[5] Dulcodes Series LP UV systems have electronic ballast.
[6] UV systems are Low pressure UV lamp type with a manual cleaning system.