ANSI/APSP 16 (ASME/ANSI A112.19.8)
Suction Fittings for Use in Swimming Pools, Wading Pools,
Spas, Hot Tubs and Whirlpool Bathtub Appliances



 
A.S.A. Mfg. Inc. 
14879 Southwest 111th Street
Dunnellon, FL 34432 
United States 
352-465-0236
Visit this company's website

Facility : Dunnellon, FL
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

Sumps[1] [2]
N/A FPK-50-809[3] N/A N/A
N/A FPK-50-812-4[4] N/A N/A
N/A FPK-50-812-18-6[5] N/A N/A
N/A FPK-50-818-6[6] N/A N/A
N/A FPK-50-818-24-8[7] N/A N/A
N/A FPK-50-824-10[8] N/A N/A

[1] This sump complies with the Figure 2 Sump Dimensional requirements of ASME
    A112.19.8a-2008.
[2] This sump complies with the dimensional requirements of ASTM-D2466.
[3] 9" x 9" x 12" with 3" outlet
[4] 12" x 12" x 12" with 4" outlet
[5] 12" x 12" x 18" with 6" outlet
[6] 18" x 18" x 20" with 6" outlet
[7] 18" x 18" x 24" with 8" outlet
[8] 24" x 24" x 30" with 10" outlet


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Carvin Pool Equipment Inc. 
4000 Casavant Boulevard
Saint Hyacinthe, QC J2S 9E3 
Canada 
866-979-4501 
450-250-4500

Facility : Saint Hyacinthe, Québec, Canada
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

8" Round Suction Outlet Cover[1] [2]
      
43102409 MO215-AV Wall and Floor 82
43102409 MOL215-AV Wall and Floor 82
43102409 MD-G2-AV Wall and Floor 82
43102409 MD-L2-AV Wall and Floor 82
43102409 MD-G15-AV Wall and Floor 82
43102409 MD-L15-AV Wall and Floor 82

[1] Certified to ANSI/APSP-16 and NSF/ANSI Standard 50.
[2] NSF Listed unit is white.




 
Current Systems, Inc. 
1645 Donlon Street
Suite 104 
Ventura, CA 93003 
United States 
866-372-8886 
805-482-1091
Visit this company's website

Facility : Ventura, CA
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

18" x 23" Suction Outlet Cover[1] [2] [3]
      
CSI 1823 RF 125 Floor 175

[1] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50
[2] NSF Listed unit is white.
[3] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a Registered Design Professional and installed per
    the manufacturer's instructions.

20" x 44" Suction Outlet Cover[1] [2] [3]
      
CSI 2044 RF 127 Floor 2032
CSI 2044 RF 127 Wall 2032

[1] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50
[2] NSF Listed unit is white.
[3] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a Registered Design Professional and installed per
    the manufacturer's instructions.

Riverflow System[1] [2] [4]
      
RFS 200 RFS 125 Floor 2440
RFS 200 RFS 125 Wall 2440

[1] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50
[2] NSF Listed unit is white.
[4] Certified for use with Riverflow Axial Flow Pump CF104.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Eureka Manufacturing Co., Inc. 
P.O. Box 1473
Bismarck, ND 58502 
United States 
800-472-1712 
701-223-7930
Visit this company's website

Facility : Eureka, SD
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

24" x 24" Suction Outlet Cover[1] [2]
      
DSF24x24 Field Fabricated - Figure 2 Floor 555

[1] Certified to ASME A112.19.8a-2008.
[2] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of Figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a registered design professional and installed per
    the manufacturer's instructions.

30" x 36" Suction Outlet Cover[1] [2]
      
DSF30x36 Field Fabricated - Figure 2 Floor 2080
DSF30x36 Field Fabricated - Figure 2 Wall 2056

[1] Certified to ASME A112.19.8a-2008.
[2] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of Figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a registered design professional and installed per
    the manufacturer's instructions.

30" x 48" Suction Outlet Cover[1] [2]
      
DSF30x48[6] Field Fabricated - Figure 2 Wall 2398
      
DSR30x48[4] Field Fabricated - Figure 2 Floor 2494
      
DSR30x48[5] Field Fabricated - Figure 2 Floor 3162
      
DSR30x48[3] Field Fabricated - Figure 2 Floor 1630
      
DSF30x48[6] Field Fabricated - Figure 2 Floor 3589

[1] Certified to ASME A112.19.8a-2008.
[2] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of Figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a registered design professional and installed per
    the manufacturer's instructions.
[3] Tested with a 12" x 36" sump.
[4] Tested with a 18" x 36" sump.
[5] Tested with a 24" x 36" sump.
[6] Tested with a 24" x 42" sump.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Hayward Industries, Inc. 
620 Division Street
Elizabeth, NJ 07207 
United States 
908-351-5400
Visit this company's website

Facility : Pomona, CA
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

8" Round Suction Outlet Cover[1]
      
WG1048E[2] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Floor 125.6
WG1048E[2] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Wall 72
      
WG1048EW[3] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Wall and Floor 72

[1] Certified to ASME A112.19.8-2007 and NSF/ANSI Standard 50.
[2] NSF Listed units are black, dark gray, gray, and white.
[3] NSF Listed units are black, gray, and white.

9" x 9" Suction Outlet Cover[4] [5]
      
WG1031B SP1062A1 Floor 89.1
WG1031B SP1062A1 Wall and Floor 84

[4] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[5] NSF Listed unit is white.

12" X 12" Suction Outlet Cover[1] [5] [6] [7]
      
WG1032B Field Fabricated - Figure 2 Floor 180
WG1032B Field Fabricated - Figure 2 Wall 112

[1] Certified to ASME A112.19.8-2007 and NSF/ANSI Standard 50.
[5] NSF Listed unit is white.
[6] Only the drain cover has been Certified by NSF International to ASME A112.19.8-2007 and
    NSF/ANSI Standard 50.  The drain cover was evaluated to the requirements of the standard
    with the sump stated above.  The sump is not Certified under this specific Listing. 
    Installers of the drain cover should ensure the sump and fasteners meet the requirements
    of ASME A112.19.8 and the sump has dimensions equivalent to the test sump stated above.
[7] Per ASME A112.19.8-2007, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacturer's instructions.

18" x 18" Suction Outlet Cover[4] [5] [6] [7]
      
WG1033B Field Fabricated - Figure 2 Floor 485
WG1033B Field Fabricated - Figure 2 Wall 485

[4] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[5] NSF Listed unit is white.
[6] Only the drain cover has been Certified by NSF International to ASME A112.19.8-2007 and
    NSF/ANSI Standard 50.  The drain cover was evaluated to the requirements of the standard
    with the sump stated above.  The sump is not Certified under this specific Listing. 
    Installers of the drain cover should ensure the sump and fasteners meet the requirements
    of ASME A112.19.8 and the sump has dimensions equivalent to the test sump stated above.
[7] Per ASME A112.19.8-2007, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacturer's instructions.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.

Facility : Clemmons, NC
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

8" Round Suction Outlet Cover[1]
      
WG1048E[2] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Floor 125.6
WG1048E[2] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Wall 72
      
WG1048E1[3] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Floor 125.6
      
WG1048EW[4] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Wall and Floor 72

[1] Certified to ASME A112.19.8-2007 and NSF/ANSI Standard 50.
[2] NSF Listed units are black, dark gray, gray, and white.
[3] NSF Listed unit is white.
[4] NSF Listed units are black, gray, and white.

9" x 9" Suction Outlet Cover[3] [5]
      
WG1031B SP1062A1 Floor 89.1
WG1031B SP1062A1 Wall and Floor 84

[3] NSF Listed unit is white.
[5] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.

12" X 12" Suction Outlet Cover[1] [3] [6] [7]
      
WG1032B Field Fabricated - Figure 2 Floor 180
WG1032B Field Fabricated - Figure 2 Wall 112

[1] Certified to ASME A112.19.8-2007 and NSF/ANSI Standard 50.
[3] NSF Listed unit is white.
[6] Only the drain cover has been Certified by NSF International to ASME A112.19.8-2007 and
    NSF/ANSI Standard 50.  The drain cover was evaluated to the requirements of the standard
    with the sump stated above.  The sump is not Certified under this specific Listing. 
    Installers of the drain cover should ensure the sump and fasteners meet the requirements
    of ASME A112.19.8 and the sump has dimensions equivalent to the test sump stated above.
[7] Per ASME A112.19.8-2007, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacturer's instructions.

18" X 18" Suction Outlet Cover[3] [5] [6] [7]
      
WG1033B Field Fabricated - Figure 2 Floor 485
WG1033B Field Fabricated - Figure 2 Wall 485

[3] NSF Listed unit is white.
[5] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[6] Only the drain cover has been Certified by NSF International to ASME A112.19.8-2007 and
    NSF/ANSI Standard 50.  The drain cover was evaluated to the requirements of the standard
    with the sump stated above.  The sump is not Certified under this specific Listing. 
    Installers of the drain cover should ensure the sump and fasteners meet the requirements
    of ASME A112.19.8 and the sump has dimensions equivalent to the test sump stated above.
[7] Per ASME A112.19.8-2007, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacturer's instructions.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.

Facility : Jiangsu Province, China
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

8" Round Suction Outlet Cover[1]
      
WG1048E[2] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Floor 125.6
WG1048E[2] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Wall 72
      
WG1048EW[3] SP1048A
SP1049A
SP1051A
SP1052A
SP1053A
SP1054A
SP1153A
SP1154A
SP1154AS
WG1048A
WG1049A
WG1051A
WG1052A
WG1053A
WG1054A
Wall and Floor 72

[1] Certified to ASME A112.19.8-2007 and NSF/ANSI Standard 50.
[2] NSF Listed units are black, dark gray, gray, and white.
[3] NSF Listed units are black, gray, and white.

9" x 9" Suction Outlet Cover[4] [5]
      
WG1031B SP1062A1 Floor 89.1
WG1031B SP1062A1 Wall and Floor 84

[4] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[5] NSF Listed unit is white.

12" x 12" Suction Outlet Cover[1] [5] [6] [7]
      
WG1032B Field Fabricated - Figure 2 Floor 180
WG1032B Field Fabricated - Figure 2 Wall 112

[1] Certified to ASME A112.19.8-2007 and NSF/ANSI Standard 50.
[5] NSF Listed unit is white.
[6] Only the drain cover has been Certified by NSF International to ASME A112.19.8-2007 and
    NSF/ANSI Standard 50.  The drain cover was evaluated to the requirements of the standard
    with the sump stated above.  The sump is not Certified under this specific Listing. 
    Installers of the drain cover should ensure the sump and fasteners meet the requirements
    of ASME A112.19.8 and the sump has dimensions equivalent to the test sump stated above.
[7] Per ASME A112.19.8-2007, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacturer's instructions.

18" x 18" Suction Outlet Cover[4] [5] [6] [7]
      
WG1033B Field Fabricated - Figure 2 Wall 485
WG1033B Field Fabricated - Figure 2 Floor 485

[4] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[5] NSF Listed unit is white.
[6] Only the drain cover has been Certified by NSF International to ASME A112.19.8-2007 and
    NSF/ANSI Standard 50.  The drain cover was evaluated to the requirements of the standard
    with the sump stated above.  The sump is not Certified under this specific Listing. 
    Installers of the drain cover should ensure the sump and fasteners meet the requirements
    of ASME A112.19.8 and the sump has dimensions equivalent to the test sump stated above.
[7] Per ASME A112.19.8-2007, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacturer's instructions.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Lawson Aquatics, Inc. 
6 Jefferson Drive
Coventry, RI 02816 
United States 
401-821-2200
Visit this company's website

Facility : GuangDong Province, China
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

6"[1] [2] [3]
      
MLD-SG-06 MLD-SG-06 Floor 44
MLD-SG-06 MLD-SG-06 Wall 49

[1] Certified to ASME A112.19.8a-2008.
[2] NSF Listed units black and white.
[3] Suction cover and grate Certified to NSF 50.

9" x 9"[1] [2] [3]
      
MLD-SG-0909 Super Sump™ Floor 261
MLD-SG-0909 Super Sump™ Wall 248
      
MLD-FGD-0909[4] Field Fabricated - Figure 2 Floor 261
MLD-FGD-0909[4] Field Fabricated - Figure 2 Wall 248

[1] Certified to ASME A112.19.8a-2008.
[2] NSF Listed units black and white.
[3] Suction cover and grate Certified to NSF 50.
[4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME
    A112.19.-2008). The flow rating for the drain cover is approved for use over a field
    fabricated main drain sump that meets the requirements of Figure 2 and the stipulations
    of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008).

12" x 12"[1] [2] [3]
      
MLD-SG-1212 Super Sump™ Floor 400
MLD-SG-1212 Super Sump™ Wall 340
      
MLD-FGD-1212[4] Field Fabricated - Figure 2 Floor 365
MLD-FGD-1212[4] Field Fabricated - Figure 2 Wall 365

[1] Certified to ASME A112.19.8a-2008.
[2] NSF Listed units black and white.
[3] Suction cover and grate Certified to NSF 50.
[4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME
    A112.19.-2008). The flow rating for the drain cover is approved for use over a field
    fabricated main drain sump that meets the requirements of Figure 2 and the stipulations
    of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008).

18" x 18"[1] [2] [3]
      
MLD-SG-1818 Super Sump™ Floor 816
MLD-SG-1818 Super Sump™ Wall 712
      
MLD-FGD-1818[4] Field Fabricated - Figure 2 Floor 816
MLD-FGD-1818[4] Field Fabricated - Figure 2 Wall 712

[1] Certified to ASME A112.19.8a-2008.
[2] NSF Listed units black and white.
[3] Suction cover and grate Certified to NSF 50.
[4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME
    A112.19.-2008). The flow rating for the drain cover is approved for use over a field
    fabricated main drain sump that meets the requirements of Figure 2 and the stipulations
    of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008).

18" x 36"[1] [2] [3]
      
FI-SG-1836[4] [5] FI-SG-1836 Floor 2080
FI-SG-1836[4] [5] FI-SG-1836 Wall 1496
      
FI-SG-1836[5] Field Fabricated - Figure 2 Floor 2401
      
MLD-FG-1836 Field Fabricated - Figure 2 Floor 2401

[1] Certified to ASME A112.19.8a-2008.
[2] NSF Listed units black and white.
[3] Suction cover and grate Certified to NSF 50.
[4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME
    A112.19.-2008). The flow rating for the drain cover is approved for use over a field
    fabricated main drain sump that meets the requirements of Figure 2 and the stipulations
    of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008).
[5] Prefabricated fiberglass sump with 10" connection.

18" x 54"[1] [2] [3]
      
FI-SG-1854[5] Field Fabricated - Figure 2 Floor 4269
      
MLD-FG-1854 Field Fabricated - Figure 2 Floor 4269

[1] Certified to ASME A112.19.8a-2008.
[2] NSF Listed units black and white.
[3] Suction cover and grate Certified to NSF 50.
[5] Prefabricated fiberglass sump with 10" connection.

18" x 72"[1] [2] [3]
      
FI-SG-1872[5] Field Fabricated - Figure 2 Floor 4518
      
MLD-FG-1872 Field Fabricated - Figure 2 Floor 4518

[1] Certified to ASME A112.19.8a-2008.
[2] NSF Listed units black and white.
[3] Suction cover and grate Certified to NSF 50.
[5] Prefabricated fiberglass sump with 10" connection.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Master Spas, Inc. 
6927 Lincoln Parkway
Fort Wayne, IN 46804 
United States 
800-860-7727 
260-436-9100
Visit this company's website

Facility : Fort Wayne, IN
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

Swim Spa Propulsion System[1] [2]
      
X804490 WAVE Wall [3]
      
X717900 WAVE Wall [3]
      
X804490 WAVE XP Wall [3]
      
X717900 WAVE XP Wall [3]
      
X804490 WAVE XP PRO Wall [3]
      
X717900 WAVE XP PRO Wall [3]

[1] Certified to APSP-16-2011.
[2] Motor controller frequency cannot exceed 68 Hz. The product was tested as a complete
    system (Master Spas, Inc. Wave, Wave XP, and Wave XP PRO), along with the manufacturer
    supplied motor, submerged suction outlet cover (Master Spas P/N X804490) and propeller
    (Master Spas P/N X400125 and X400820). This product is not NSF Certified as an
    individual submerged suction fitting.
[3] A flow rating for the intake grates was not established due to the open design of the
    intake grates and because the Master Spas submerged suction outlet covers were tested as
    part of a Master Spas Swim Spa. The max allowable motor drive frequency of 68 Hz for the
    7.5 horsepower, 1750 rpm motor has been measured for the propulsion fittings in use with
    the Swim Spa. This rating only applies with the standard motor, and the user controls
    must be capped to prevent running at a higher speed.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Neptune-Benson, LLC 
6 Jefferson Drive
Coventry, RI 02816 
United States 
401-821-2200
Visit this company's website

Facility : Coventry, RI
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

30" x 30" Suction Outlet Cover[1] [4] [5]
      
AEGIS[2] [3] Field Fabricated-FG2 Floor 1432
AEGIS[2] [3] Field Fabricated-FG2 Wall 1120
      
AEGIS[6] 242424SSMD-AE-8 Floor 1432
AEGIS[6] 242424SSMD-AE-8 Wall 1120
      
AEGIS[7] Reference Footnote [7] Floor 1504

[1] Certified to ASME A112.19.8a-2008.
[2] Per ASME A112.19.8a-2008, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened and secured according to the drain cover and the sump
    manufacturer's instructions.
[3] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of the figure 2 in the ASME A112.19.8a-2008 Standard for Sunction Fittings,
    providing the sump is qualified by a Registered Design professional and installed per
    the manufacturer's instructions.
[4] NSF Listed units have a white cover.
[5] For single and multiple drain use.
[6] The sumps are stainless steel.
[7] Drain cover tested with a centrally located in floor 12 inch diameter pipe (No Sump).
    Testing qualifies use with 12 inch diameter pipe or smaller.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Paddock Pool Equipment Co, Inc. 
Paddock Parkway
P.O. Box 11676 
Rock Hill, SC 29731 
United States 
803-324-1111
Visit this company's website

Facility : Rock Hill, SC
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

Suction Fitting for Multiple Drain Use Only[1] [2] [3] [4]
      
2020PCDC 1414ESMD Floor 1200
      
2020PCGO[5] 2040ESMD Floor 1960
2020PCGO[5] 2040ESMD Wall 1960
      
2040PCGO[5] 2040ESMD Floor 1960
2040PCGO[5] 2040ESMD Wall 1960
      
2424PCDC 1818ESMD Floor 1420
2424PCDC 1818ESMD Wall 1420
      
2424PCFC 1818ESMD Floor 915
2424PCFC 1818ESMD Wall 915
      
2448PCFC[6] 2448ESMD Floor 3500
2448PCFC[6] 2448ESMD Wall 3000

[1] For multiple drain use only.
[2] Per ASME A112.19.8a-2008, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that Standard shall be permitted when specified and
    designed by a registered design professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacturer's instructions.
[3] For use with 8-32x1/4" Pan Head Phillips # 2 316L SS.
[4] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[5] Utilizes two (2) 2020PCGO suction fittings.
[6] Utilizes two (2) 2424PCFC suction fittings.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Praher Plastics Canada Ltd. 
101 Saunders Road
Barrie, ON L4M 6E7 
Canada 
705-725-1100

Facility : Barrie, Ontario, Canada
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

10" x 10" Submerged Suction Outlet Cover[1] [2] [3]
      
FG10VG Field Fabricated-FG2 Floor 108
FG10VG Field Fabricated-FG2 Wall 108

[1] Certified to ASME A112.19.8b-2009.
[2] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of figure 2 in the ASME A112.19.8B-2009 Standard for Suction Fittings,
    providing the sump is qualified by a Registered Design Professional and installed per
    the manufacturer's instructions.
[3] NSF Listed unit is white.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Shasta Industries DBA A&A Manufacturing 
3750 West Indian School Road
Phoenix, AZ 85019 
United States 
602-859-6567
Visit this company's website

Facility : Phoenix, AZ
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

10" Round Suction Outlet Cover[1] [2] [3] [4]
      
790 Field Fabricated
Sta-Rite 86104000
Floor 93

[1] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[2] NSF Listed units are black (560690, 561385, 564308), blue (560702, 561393, 564316), gold
    (560711, 561406, 564324), grey (560729, 561414, 564332), light grey (560737), and white
    (560745, 561422, 564341).
[3] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a Registered Design Professional and installed per
    the manufacturer's instructions.
[4] Uses the pebble top cover and ribbed sump.

Channel Drain[1] [7] [8]
      
571444[4] [5] Sump included Floor 237
571444[4] [5] Sump included Wall and Floor 167.2
      
571461[4] [5] Sump included Floor 237
571461[4] [5] Sump included Wall and Floor 167.2
      
571452[4] [5] Sump included Floor 237
571452[4] [5] Sump included Wall and Floor 167.2
      
571495[4] [5] Sump included Floor 237
571495[4] [5] Sump included Wall and Floor 167.2
      
571487[4] [5] Sump included Floor 237
571487[4] [5] Sump included Wall and Floor 167.2
      
571479[4] [5] Sump included Floor 237
571479[4] [5] Sump included Wall and Floor 167.2
      
571508[4] [6] Sump included Floor 237
571508[4] [6] Sump included Wall and Floor 184
      
571524[4] [6] Sump included Floor 237
571524[4] [6] Times New Roman Wall and Floor 184
      
571576[4] [6] Sump included Floor 237
571576[4] [6] Sump included Wall and Floor 184
      
571559[4] [6] Sump included Floor 237
571559[4] [6] Sump included Wall and Floor 184
      
571541[4] [6] Sump included Floor 237
571541[4] [6] Sump included Wall and Floor 184
      
571532 Sump included Floor 237
      
571532[4] [6] Sump included Wall and Floor 184
      
552921[5] Sump included Floor 237
552921[5] Sump included Wall and Floor 167.2
      
552930[5] Sump included Floor 237
552930[5] Sump included Wall and Floor 167.2
      
554581[5] [9] Sump included Floor 237
554581[5] [9] Sump included Wall and Floor 167.2
      
554599[5] [9] Sump included Floor 237
554599[5] [9] Sump included Wall and Floor 167.2
      
556316[5] Sump included Floor 237
556316[5] Sump included Wall and Floor 167.2
      
556324[6] Sump included Floor 237
556324[6] Sump included Wall and Floor 184
      
556332[5] Sump included Floor 237
556332[5] Sump included Wall and Floor 167.2
      
556341[6] Sump included Floor 237
556341[6] Sump included Wall and Floor 184
      
556367[6] Sump included Floor 237
556367[6] Sump included Wall and Floor 184
      
556375[6] [9] Sump included Floor 237
556375[6] [9] Sump included Wall and Floor 184
      
556383[6] Sump included Floor 237
556383[6] Sump included Wall and Floor 184
      
556391[6] [9] Sump included Floor 237
556391[6] [9] Sump included Wall and Floor 184
      
556404[6] Sump included Floor 237
556404[6] Sump included Wall and Floor 184
      
556412[6] [9] Sump included Floor 237
556412[6] [9] Sump included Wall and Floor 184
      
556421[5] Sump included Floor 237
556421[5] Sump included Wall and Floor 167.2
      
556439[5] [9] Sump included Floor 237
556439[5] [9] Sump included Wall and Floor 167.2
      
556442[6] Sump included Floor 237
556442[6] Sump included Wall and Floor 184
      
556445[6] [9] Sump included Floor 237
556445[6] [9] Sump included Wall and Floor 184
      
556447[6] Sump included Floor 237
556447[6] Sump included Wall and Floor 184
      
556448[5] Sump included Floor 237
556448[5] Sump included Wall and Floor 167.2
      
556451[5] [9] Sump included Floor 237
556451[5] [9] Sump included Wall and Floor 167.2
      
556455[6] Sump included Floor 237
556455[6] Sump included Wall and Floor 184
      
556463[5] Sump included Floor 237
556463[5] Sump included Wall and Floor 167.2
      
556471[5] [9] Sump included Floor 237
556471[5] [9] Sump included Wall and Floor 167.2
      
558320[5] Sump included Floor 237
558320[5] Sump included Wall and Floor 167.2
      
558338[5] Sump included Floor 237
558338[5] Sump included Wall and Floor 167.2
      
558346[5] Sump included Floor 237
558346[5] Sump included Wall and Floor 167.2
      
558354[5] Sump included Floor 237
558354[5] Sump included Wall and Floor 237
      
558362[6] Sump included Floor 237
558362[6] Sump included Wall and Floor 184
      
558371[6] Sump included Floor 237
558371[6] Sump included Wall and Floor 184
      
558389[6] Sump included Floor 237
558389[6] Sump included Wall and Floor 184
      
558397[6] Sump included Floor 237
558397[6] Sump included Wall and Floor 184
      
558434[6] Sump included Floor 237
558434[6] Sump included Wall and Floor 184
      
558442[6] [9] Sump included Floor 237
558442[6] [9] Sump included Wall and Floor 184
      
558451[5] Sump included Floor 237
558451[5] Sump included Wall and Floor 167.2
      
558469[5] [9] Sump included Floor 237
558469[5] [9] Sump included Wall and Floor 167.2

[1] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[4] Uses the pebble top cover and ribbed sump.
[5] 3" connection single drain.
[6] 3" connection dual drain.
[7] Model numbers specify Certified colors: black, blue, dark gray, gold, light gray, or
    white.
[8] Certified for Pool and Spa use.
[9] Uses the ribbed sump.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
SwimEx, Inc. 
390 Airport Road
Fall River, MA 02720 
United States 
800-877-7946 
508-646-1600

Facility : Fall River, MA
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

SwimEx Stainless Steel Cover[1] [2] [3] [4]
      
70157 - 55" x 19" SwimEx Paddlewheel System Wall N/A
      
71196 - 53" x 39" SwimEx Paddlewheel System Wall N/A
      
72028 - 55" x 29" SwimEx Paddlewheel System Wall N/A

[1] Certified to ASME A112.19.8a-2008.
[2] This submerged suction outlet cover is Certified for use only in a SwimEx Paddlewheel
    System with the following models: 
    Commercial Models  - SX400OT, SX470T, SX500OT, SX500T,  SX600T, SX700T, SX800T, ASX900T,
    
                         and SX1000T
    Residential Models - SX400OS, SX480S, SX500OS, SX500S, SX6000S, and SX10000S
[3] Motor controller frequency can not exceed 44.42 Hz for models utilizing the 7.5 hp pump.
[4] A flow rate was not established since the SwimEx submerged suction outlet covers were
    tested as part of a SwimEx Paddlewheel System and are for use only with a SwimEx
    Paddlewheel System.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Triodyne Safety Systems LLC 
3054 North Lake Terrace
Glenview, IL 60026 
United States 
847-677-4730
Visit this company's website

Facility : Machesney Park, IL
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

Main Drain Cover
      
TSS-2800 Anti-Hair Snare Plus[1] [2] [3] [4] Sta-Rite 8" Round WC 73-1P Floor 68.8

[1] Only the drain cover has been Certified by NSF International to ASME A112.19.8-2007 and
    NSF/ANSI Standard 50.  The drain cover was evaluated to the requirements of the standard
    with the sump stated above.  The sump is not Certified under this specific Listing. 
    Installers of the drain cover should ensure the sump and fasteners meet the requirements
    of ASME A112.19.8 and the sump has dimensions equivalent to the test sump stated above.
[2] Per ASME A112.19.8-2007, the use of the suction fitting with a field fabricated sump
    built in accordance with Figure 2 of that standard shall be permitted when specified and
    designed by a Registered Design Professional.  Installers should also ensure that the
    drain cover is installed, fastened, and secured according to the drain cover and the
    sump manufacterer's instructions.
[3] NSF Listed unit is white.
[4] Testing assembly included use of ADP 2000 collar.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Waterway Plastics 
2200 East Sturgis Road
Oxnard, CA 93030 
United States 
805-981-0262

Facility : Oxnard, CA
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

10" Ultra Retro Suction Outlet[1] [3]
      
640-212X V 642-3190[4] Floor 224
640-212X V 642-3190[4] Wall 192
      
640-213X V 642-3180[5] Floor 224
640-213X V 642-3180[5] Wall 192
      
640-214X V 642-3180[5] Floor 224
640-214X V 642-3180[5] Wall 192

[1] Certified to ASME A112.19.8a-2008
[3] X indicates color code.  0 is the code for the color white.  NSF Listed unit is white.
[4] Adapter plate model number 642-3190 is used for new applications.
[5] Adapter plate model number 642-3180 is used for retrofit applications.

24" x 24"[1] [2] [3]
      
640-476X V Field Fabricated - Figure 2 Floor 2035

[1] Certified to ASME A112.19.8a-2008
[2] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a Registered Design Professional and installed per
    the manufacturer's instructions
[3] X indicates color code.  0 is the code for the color white.  NSF Listed unit is white.

8" Round Ultra Suction Outlet[1] [3]
      
640-81xx V 672-2430 (concrete pools) Floor 110
640-81xx V 672-2430 (vinyl pools) Floor 110
640-81xx V 672-2430 (concrete pools) Wall 92
640-81xx V 672-2430 (vinyl pools) Wall 92

[1] Certified to ASME A112.19.8a-2008
[3] X indicates color code.  0 is the code for the color white.  NSF Listed unit is white.

Clover Leaf[1] [3]
      
640-100X V 642-1020 Floor 840
640-100X V 642-1020 Wall 508

[1] Certified to ASME A112.19.8a-2008
[3] X indicates color code.  0 is the code for the color white.  NSF Listed unit is white.

Diamond Strip Drain Submerged Suction Outlet[1] [3]
      
640-134X V 642-1300 (vinyl liner pools) Center Piped Sump
642-1320 (concrete pools) Center Piped Sump
Floor 280
640-134X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Floor 320
640-134X V 642-1300 (vinyl liner pools) Center Piped Sump
642-1320 (concrete pools) Center Piped Sump
Wall 216
640-134X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Wall 216
      
640-135X V 642-1300 (vinyl liner pools) Center Piped Sump
642-1320 (concrete pools) Center Piped Sump
Floor 280
640-135X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Floor 320
640-135X V 642-1300 (vinyl liner pools) Center Piped Sump
642-1320 (concrete pools) Center Piped Sump
Wall 216
640-135X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Wall 216
      
640-136X V 642-1300 (vinyl liner pools) Center Piped Sump
642-1320 (concrete pools) Center Piped Sump
Floor 280
640-136X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Floor 320
640-136X V 642-1320 (concrete pools) Center Piped Sump
642-1300 (vinyl liner pools) Center Piped Sump
Wall 216
640-136X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Wall 216
      
640-137X V 642-1300 (vinyl liner pools) Center Piped Sump
642-1320 (concrete pools) Center Piped Sump
Floor 280
640-137X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Floor 320
640-137X V 642-1300 (vinyl liner pools) Center Piped Sump
642-1320 (concrete pools) Center Piped Sump
Wall 216
640-137X V 642-1300 (vinyl liner pools) Two Outer Piped Sump
642-1320 (concrete pools) Two Outer Piped Sump
Wall 216

[1] Certified to ASME A112.19.8a-2008
[3] X indicates color code.  0 is the code for the color white.  NSF Listed unit is white.

Ultra Strip Drain Submerged Suction Outlet Model[1] [3]
      
640-132X V 642-1320 (concrete pools) Center Piped Sump Floor 288
640-132X V 642-1320 (concrete pools) Two Outer Piped Sump Floor 352
640-132X V 642-1320 (concrete pools) Center Piped Sump Wall 232
640-132X V 642-1320 (concrete pools) Two Outer Piped Sump Wall 296
      
640-130X V 642-1300 (vinyl liner pools) Center Piped Sump Floor 288
640-130X V 642-1300 (vinyl liner pools) Two Outer Piped Sump Floor 352
640-130X V 642-1300 (vinyl liner pools) Center Piped Sump Wall 232
640-130X V 642-1300 (vinyl liner pools) Two Outer Piped Sump Wall 296

[1] Certified to ASME A112.19.8a-2008
[3] X indicates color code.  0 is the code for the color white.  NSF Listed unit is white.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Wellness Marketing Corporation, DBA Endless Pools 
1601 Dutton Mill Road
Aston, PA 19014 
United States 
800-732-8660 
610-497-8676
Visit this company's website

Facility : Aston, PA
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

Endless Pools Stainless Steel Cover[1]
      
#18-59 18" x 59"[2] [3] [6] Dual Propulsion/Elite Endless Pools/Spa System Wall N/A
      
#29-19 29" x 19"[2] [4] [5] Endless Pools, Inc. Fastlane® System Wall N/A
      
125020 18" X 54"[7] [11] Venturi Endless Pool With and Without Treadmill Wall [12]
      
EP 311460 59.5" x 13"[7] [8] [9] [10] 7' Endless Pools/Spa System Part #138186 Wall N/A
      
EP 311530 71.5" x 13"[7] [8] [9] [10] 8' Endless Pools/Spa System Part #138187 Wall N/A
      
EP 311560 83.5" x 13"[7] [8] [9] [10] 9' Endless Pools/Spa System Part #138188 Wall N/A
      
EP 311590 95.5" x 13"[7] [8] [9] [10] 10' Endless Pools/Spa System Part #138189 Wall N/A

[1] A flow rate was not established since the Endless pools submerged suction outlet covers
    were tested as part of (Original Endless Pools/Spa System and the Performance Endless
    Pools/Spa System, Dual Propulsion/Elite Endless Pools/Spa System, and Endless Pools,
    Inc. Fastlane® System).
[2] Certified to ASME A112.19.8b-2009.
[3] This submerged suction outlet cover is Certified for use only in Endless Pools/Spa
    System Dual Propulsion/Elite Endless Pools/Spa System.
[4] This submerged suction outlet cover is Certified for use only in Endless Pools, Inc.
    Fastlane® System.
[5] Maximum allowable hydraulic power unit drive flow rate of 4.8 gpm on the Fastlane model.
[6] Maximum allowable hydraulic power unit drive flow rate of 10.24 gpm single 7.5 HP power
    unit on the Elite model.
[7] Certified to ANSI/APSP 16-2011 ASME A112.19.8a-2008.
[8] This submerged suction outlet cover is Certified for use only in an Original Endless
    Pools/Spa System and the Performance Endless Pools/Spa System.
[9] The maximum allowable hydraulic power unit drive flow rate submerged suction outlet
    cover is 5.12 gpm when installed in an Original Endless Pools/Spa System.
[10] The Maximum allowable hydraulic power unit drive flow rate submerged suction outlet
     cover is 6.4 gpm when installed in a Performance Endless Pools/Spa System.
[11] This submerged suction outlet cover is certified for use in a Venturi Endless Pool With
     and Without Treadmill.
[12] Maximum flow rate of 306 gpm without treadmill and 304 gpm with treadmill.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.


 
Whitten Products Division 
Hydrotech Systems, Ltd.
One Aquatic Center 
P.O. Box 648 
Cohoes, NY 12047 
United States 
518-783-0038
Visit this company's website

Facility : Cohoes, NY
Suction Fitting Model Sump Model or Field Type Orientation (Wall and/or Floor) Design Flow Rate (GPM)

24" X 24" Suction Outlet Cover
      
ADG2424MD[1] [2] 242424SB Floor 1390

[1] Certified to ASME A112.19.8a-2008 and NSF/ANSI Standard 50.
[2] This cover is approved for use over a field fabricated main drain sump that meets the
    requirements of figure 2 in the ASME A112.19.8a-2008 Standard for Suction Fittings,
    providing the sump is qualified by a Registered Design Professional and installed per
    the manufacturer's instructions.


NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
      A112.19.8b-2009 which have been withdrawn.

Number of matching Manufacturers is 16
Number of matching Products is 245
Processing time was 1 seconds