NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects



 
Brenntag Great Lakes LLC 
4420 North Harley Davidson Avenue
Wauwatosa, WI 53225 
United States 
262-252-3550
Visit this company's website

Facility : Chicago, IL


Ammonium Hydroxide
Trade Designation Product Function Max Use
Aqua Ammonia Chloramination 5mg/L
Aqua Ammonia 15 deg Chloramination 5mg/L
Aqua Ammonia 19.5% Chloramination 5mg/L
Aqua Ammonia 26 Degree Chloramination 5mg/L
Aqua Ammonia 8-10 Chloramination 5mg/L

Ferric Sulfate
Trade Designation Product Function Max Use
Ferric Sulfate 50% Coagulation & Flocculation 600mg/L
Ferric Sulfate 60% Coagulation & Flocculation 600mg/L

Phosphoric Acid
Trade Designation Product Function Max Use
Phosphoric Acid 75% Corrosion & Scale Control
pH Adjustment
13mg/L
Phosphoric Acid 85% Corrosion & Scale Control
pH Adjustment
12mg/L

Sodium Bisulfite[1]
Trade Designation Product Function Max Use
Sodium Bisulfite 40% Dechlorinator & Antioxidant 46mg/L
Sodium Bisulfite Solution Dechlorinator & Antioxidant 46mg/L

[1] This product contains sulfite.
    Sulfites have been known to cause potentially lethal allergic reactions in sulfite-sensitive individuals.
    The maximum recommended allowable residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).


Facility : Des Moines, IA


Phosphoric Acid
Trade Designation Product Function Max Use
Phosphoric Acid 75% Corrosion & Scale Control
pH Adjustment
13mg/L
Phosphoric Acid 85% Corrosion & Scale Control
pH Adjustment
12mg/L

Sodium Hydroxide
Trade Designation Product Function Max Use
Caustic Soda 20% Corrosion & Scale Control
pH Adjustment
250mg/L
Caustic Soda 25% Corrosion & Scale Control
pH Adjustment
200mg/L
Caustic Soda 30% Corrosion & Scale Control
pH Adjustment
166mg/L
Caustic Soda 50% Corrosion & Scale Control
pH Adjustment
100mg/L

Sodium Hypochlorite[HY]
Trade Designation Product Function Max Use
GenOx-Pro 125 Disinfection & Oxidation 35mg/L
Sodium Hypochlorite 12.5% Disinfection & Oxidation 35mg/L

[HY] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
     dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
     finished drinking water to ensure compliance to all applicable regulations. Also,
     reference the AWWA B300 (Hypochlorites) standard's Recommendations for the Handling and
     Storage of Hypochlorite Solutions appendix for information on preservation techniques
     for hypochlorite bleach in transit and storage.


Facility : St. Paul, MN


Miscellaneous Treatment Chemical
Trade Designation Product Function Max Use
PBTC Reverse Osmosis Antiscalant 20mg/L

Sodium Bisulfite[1]
Trade Designation Product Function Max Use
Sodium Bisulfite 40% Dechlorinator & Antioxidant 46mg/L
Sodium Bisulfite Solution Dechlorinator & Antioxidant 46mg/L

[1] This product contains sulfite.
   Sulfites have been known to cause potentially lethal allergic reactions in sulfite-sensitive individuals.
   The maximum recommended allowable residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).


Facility : Toledo, OH


Ammonium Hydroxide
Trade Designation Product Function Max Use
Aqua Ammonia Chloramination 5mg/L
Aqua Ammonia 15 deg Chloramination 5mg/L
Aqua Ammonia 19.5% Chloramination 5mg/L
Aqua Ammonia 26 Degree Chloramination 5mg/L
Aqua Ammonia 8-10 Chloramination 5mg/L

Blended Phosphates
Trade Designation Product Function Max Use
AquaPure 3610 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3619 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3627 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3628 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3637 Sequestering
Corrosion & Scale Control
25mg/L
AquaPure 3646 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3655 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3664 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3672 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3673 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3682 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3691 Corrosion & Scale Control
Sequestering
25mg/L

Ferric Chloride
Trade Designation Product Function Max Use
Ferric Chloride 37-42% Coagulation & Flocculation 250mg/L
Ferric Chloride Liquid 38-42% Coagulation & Flocculation 250mg/L

Ferric Sulfate
Trade Designation Product Function Max Use
Ferric Sulfate 50% Coagulation & Flocculation 600mg/L
Ferric Sulfate 60% Coagulation & Flocculation 600mg/L

Fluorosilicic Acid
Trade Designation Product Function Max Use
Hydrofluorosilicic Acid 23% Fluoridation 5mg/L

Hydrochloric Acid
Trade Designation Product Function Max Use
Hydrochloric Acid 20 Degree Baume Corrosion & Scale Control
pH Adjustment
40mg/L

Hydrogen Peroxide[HP]
Trade Designation Product Function Max Use
Hydrogen Peroxide 30% Oxidant 3.4mg/L
Hydrogen Peroxide 32% Oxidant 3.3mg/L
Hydrogen Peroxide 34% Oxidant 3mg/L
Hydrogen Peroxide 34.5% Oxidant 3mg/L
Hydrogen Peroxide 35% Oxidant 3mg/L
Hydrogen Peroxide 50% Oxidant 2.1mg/L
Hydrogen Peroxide 7% Tech Grade Oxidant 4.7mg/L

[HP] Use of this product shall be followed by chlorination to remove levels of hydrogen
     peroxide.  Chlorine residuals shall not exceed 4 mg/L, the EPA's proposed maximum
     residual level.

Monosodium Orthophosphate
Trade Designation Product Function Max Use
AquaPure 3601 Corrosion & Scale Control
Sequestering
25mg/L

Phosphoric Acid
Trade Designation Product Function Max Use
Phosphoric Acid 75% Corrosion & Scale Control
pH Adjustment
13mg/L
Phosphoric Acid 85% Corrosion & Scale Control
pH Adjustment
12mg/L

Sodium Bisulfite[1]
Trade Designation Product Function Max Use
Sodium Bisulfite 40% Dechlorinator & Antioxidant 46mg/L
Sodium Bisulfite Solution Dechlorinator & Antioxidant 46mg/L

[1] This product contains sulfite.
    Sulfites have been known to cause potentially lelthal allergic reactions in sulfite-sensitive individuals.
    The maximum recommended allowable residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).

Sodium Hydroxide
Trade Designation Product Function Max Use
Caustic Soda 20% Corrosion & Scale Control
pH Adjustment
250mg/L
Caustic Soda 25% Corrosion & Scale Control
pH Adjustment
200mg/L
Caustic Soda 30% Corrosion & Scale Control
pH Adjustment
166mg/L
Caustic Soda 50% Corrosion & Scale Control
pH Adjustment
100mg/L

Sodium Hypochlorite[HY]
Trade Designation Product Function Max Use
GenOx-Pro 125 Disinfection & Oxidation 84mg/L
Sodium Hypochlorite 12.5% Disinfection & Oxidation 84mg/L

[HY] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
     dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
     finished drinking water to ensure compliance to all applicable regulations. Also,
     reference the AWWA B300 (Hypochlorites) standard's Recommendations for the Handling and
     Storage of Hypochlorite Solutions appendix for information on preservation techniques
     for hypochlorite bleach in transit and storage.

Sodium Permanganate[PO]
Trade Designation Product Function Max Use
Sodium Permanganate 10% Oxidant 248mg/L
Sodium Permanganate 15% Oxidant 235mg/L
Sodium Permanganate 20% Oxidant 224mg/L
Sodium Permanganate Solution Oxidant 224mg/L

[PO] The finished drinking water shall be monitored to ensure that levels of manganese

     do not exceed 0.05 mg/L.

Sodium Polyphosphates, Glassy
Trade Designation Product Function Max Use
Sodium Hexametaphosphate 35% Corrosion & Scale Control
Sequestering
23mg/L

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Facility : Menomonee Falls, WI


Ammonium Hydroxide
Trade Designation Product Function Max Use
Aqua Ammonia Chloramination 5mg/L
Aqua Ammonia 15 deg Chloramination 5mg/L
Aqua Ammonia 19.5% Chloramination 5mg/L
Aqua Ammonia 26 Degree Chloramination 5mg/L
Aqua Ammonia 8-10 Chloramination 5mg/L

Blended Phosphates
Trade Designation Product Function Max Use
AquaPure 3610 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3619 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3627 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3628 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3637 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3646 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3655 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3664 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3672 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3673 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3682 Corrosion & Scale Control
Sequestering
25mg/L
AquaPure 3691 Corrosion & Scale Control
Sequestering
25mg/L

Citric Acid[1] [2]
Trade Designation Product Function Max Use
Citric Acid 50% Liquid Membrane Cleaner
Well Cleaning Aid
NA
Citric Acid 50% Solution Membrane Cleaner
Well Cleaning Aid
NA
Citric Acid Solution Membrane Cleaner
Well Cleaning Aid
NA

[1] This product is designed to be used off-line and flushed out prior to using the system
    for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
    of the product have been removed before placing into service.

Hydrogen Peroxide[HP]
Trade Designation Product Function Max Use
Hydrogen Peroxide 30% Oxidant 3.4mg/L
Hydrogen Peroxide 32% Oxidant 3.3mg/L
Hydrogen Peroxide 34% Oxidant 3mg/L
Hydrogen Peroxide 34.5% Oxidant 3mg/L
Hydrogen Peroxide 35% Oxidant 3mg/L
Hydrogen Peroxide 50% Oxidant 2.1mg/L
Hydrogen Peroxide 7% Tech Grade Oxidant 4.7mg/L

[HP] Use of this product shall be followed by chlorination to remove levels of hydrogen
     peroxide.  Chlorine residuals shall not exceed 4 mg/L, the EPA's proposed maximum
     residual level.

Monosodium Orthophosphate
Trade Designation Product Function Max Use
AquaPure 3601 Corrosion & Scale Control 25mg/L

Sodium Permanganate[PO]
Trade Designation Product Function Max Use
Sodium Permanganate 10% Oxidant 248mg/L
Sodium Permanganate 15% Oxidant 235mg/L
Sodium Permanganate 20% Oxidant 224mg/L
Sodium Permanganate Solution Oxidant 224mg/L

[PO] The finished drinking water shall be monitored to ensure that levels of manganese

     do not exceed 0.05 mg/L.

Sodium Polyphosphates, Glassy
Trade Designation Product Function Max Use
Sodium Hexametaphosphate 35% Corrosion & Scale Control
Sequestering
23mg/L

Zinc Orthophosphate[ZN]
Trade Designation Product Function Max Use
LAC-1001 S Corrosion & Scale Control 25mg/L
LAC-101-S Corrosion & Scale Control 20mg/L
LAC-301-S Corrosion & Scale Control 25mg/L
LAC-501 C Corrosion & Scale Control 25mg/L
LAC-501 S Corrosion & Scale Control 25mg/L

[ZN] Based on an evaluation of health effects data, the level of zinc in the finished
     drinking water shall not exceed 2.0 mg/L.