NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| Kurita America Inc. | |
| 6600 94th Avenue North | |
| Minneapolis, MN 55445 | |
| United States | |
| 866-663-7632 | |
| 763-689-3636 | |
| Visit this company's website |
Facility : CB USA
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| ROC 50 N[1] | Membrane Cleaner | NA |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Treatment Applications |
||
| Trade Designation | Product Function | Max Use |
| AvistaVitec™ 8200 | Reverse Osmosis Antiscalant | 7mg/L |
| Avista™ 200 | Reverse Osmosis Antiscalant | 7mg/L |
| Avista™ VT 8200 | Reverse Osmosis Antiscalant | 7mg/L |
| Kuriverter™ AC-427[3] | Dechlorination | 8mg/L |
| VItec™ SI410 | Reverse Osmosis Antiscalant | 3mg/L |
| VItec™1500 | Reverse Osmosis Antiscalant | 9mg/L |
| VItec™1600 | Reverse Osmosis Antiscalant | 20mg/L |
| Vitec 7400 | Reverse Osmosis Antiscalant | 15mg/L |
| Vitec™ 1000 | Reverse Osmosis Antiscalant | 26mg/L |
| Vitec™ 3000 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 3025 | Reverse Osmosis Antiscalant | 25mg/L |
| Vitec™ 4002 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 8200 | Reverse Osmosis Antiscalant | 7mg/L |
[3] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| Antichlor™ 30[3] | Dechlorination | 15mg/L |
| Biotrol 409[4] | Reverse Osmosis Membrane Biocide | 30mg/L |
| RO 510N | Reverse Osmosis Antiscalant | 15mg/L |
| Vitec 4000 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 1000 | Reverse Osmosis Antiscalant | 26mg/L |
| Vitec™ 1400 | Reverse Osmosis Antiscalant | 30mg/L |
| Vitec™ 5100 | Reverse Osmosis Antiscalant | 13mg/L |
| Vitec™ 7000 | Reverse Osmosis Antiscalant | 7mg/L |
[3] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
[4] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products should be
monitored in the finished drinking water to ensure compliance to all applicable
regulations.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ L0381[1] [2] | Membrane Cleaner | NA |
| AvistaClean™ L1181[2] | Membrane Cleaner | NA |
| AvistaClean™ L1211 | Membrane Cleaner | NA |
| AvistaClean™ L1221[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L112 | Membrane Cleaner | NA |
| Avista™ RC L211[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L212[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L403[1] [2] | Membrane Cleaner | NA |
| Avista™ RC L811[2] | Membrane Cleaner | NA |
| Avista™177[1] [2] | Membrane Cleaner | NA |
| Avista™181[1] [2] | Membrane Cleaner | NA |
| ROC 20 N[1] [2] | Membrane Cleaner | NA |
| RoClean™ L102[1] [2] | Membrane Cleaner | NA |
| RoClean™ L112 | Membrane Cleaner | NA |
| RoClean™ L211[1] [2] | Membrane Cleaner | NA |
| RoClean™ L212[1] [2] | Membrane Cleaner | NA |
| RoClean™ L403[1] [2] | Membrane Cleaner | NA |
| RoClean™ L811[2] | Membrane Cleaner | NA |
[1] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Polymer Blends[PY] |
||
| Trade Designation | Product Function | Max Use |
| RoQuest™ 4000 | Coagulation & Flocculation | 142mg/L |
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Sodium Bisulfite |
||
| Trade Designation | Product Function | Max Use |
| Dechlor 104 | Dechlorinator & Antioxidant | 40mg/L |
Facility : FW USA
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ P0327 | Membrane Cleaner | NA |
| AvistaClean™ P1219 | Membrane Cleaner | NA |
| AvistaClean™ P611 | Membrane Cleaner | NA |
| AvistaClean™MF 3000 | Membrane Cleaner | NA |
| Avista™ 127 | Membrane Cleaner | NA |
| Avista™ 146 | Membrane Cleaner | NA |
| Avista™ 192 | Membrane Cleaner | NA |
| Avista™ 199 | Membrane Cleaner | NA |
| Avista™ RC P111 | Membrane Cleaner | NA |
| Avista™ RC P112 | Membrane Cleaner | NA |
| Avista™ RC P192 | Membrane Cleaner | NA |
| Avista™ RC P303 | Membrane Cleaner | NA |
| Avista™ RC P611 | Membrane Cleaner | NA |
| Avista™ RC P903 | Membrane Cleaner | NA |
| RoClean™ P111 | Membrane Cleaner | NA |
| RoClean™ P112 | Membrane Cleaner | NA |
| RoClean™ P192 | Membrane Cleaner | NA |
| RoClean™ P303 | Membrane Cleaner | NA |
| RoClean™ P611 | Membrane Cleaner | NA |
| RoClean™ P903 | Membrane Cleaner | NA |
|
Miscellaneous Treatment Applications |
||
| Trade Designation | Product Function | Max Use |
| AvistaVitec™ 8200 | Reverse Osmosis Antiscalant | 7mg/L |
| Avista™ 200 | Reverse Osmosis Antiscalant | 7mg/L |
| Avista™ VT 8200 | Reverse Osmosis Antiscalant | 7mg/L |
| Kuriverter™ AC-427 | Dechlorination | 8mg/L |
| VItec™ SI410 | Reverse Osmosis Antiscalant | 3mg/L |
| VItec™1500 | Reverse Osmosis Antiscalant | 9mg/L |
| VItec™1600 | Reverse Osmosis Antiscalant | 20mg/L |
| Vitec 7400 | Reverse Osmosis Antiscalant | 15mg/L |
| Vitec™ 1000 | Reverse Osmosis Antiscalant | 26mg/L |
| Vitec™ 3000 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 3025 | Reverse Osmosis Antiscalant | 25mg/L |
| Vitec™ 4002 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 6400 | Reverse Osmosis Antiscalant | 20mg/L |
| Vitec™ 6500 | Reverse Osmosis Antiscalant | 20mg/L |
| Vitec™ 8200 | Reverse Osmosis Antiscalant | 7mg/L |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| Antichlor™ 30 | Dechlorination | 15mg/L |
| AvistaRQ™ 6000 | Coagulation & Flocculation | 289mg/L |
| Avista™ RQ3000 | Coagulation & Flocculation | 100mg/L |
| Biotrol 409 | Reverse Osmosis Membrane Biocide | 30mg/L |
| RO 510N | Reverse Osmosis Antiscalant | 15mg/L |
| RoQuest™ 3000 | Coagulation & Flocculation | 100mg/L |
| RoQuest™ 6000 | Coagulation & Flocculation | 289mg/L |
| Vitec 4000 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 1400 | Reverse Osmosis Antiscalant | 30mg/L |
| Vitec™ 5100 | Reverse Osmosis Antiscalant | 13mg/L |
| Vitec™ 7000 | Reverse Osmosis Antiscalant | 7mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ L0381 | Membrane Cleaner | NA |
| AvistaClean™ L1181 | Membrane Cleaner | NA |
| AvistaClean™ L1211 | Membrane Cleaner | NA |
| AvistaClean™ L1221 | Membrane Cleaner | NA |
| Avista™ RC L112 | Membrane Cleaner | NA |
| Avista™ RC L211 | Membrane Cleaner | NA |
| Avista™ RC L212 | Membrane Cleaner | NA |
| Avista™ RC L403 | Membrane Cleaner | NA |
| Avista™ RC L811 | Membrane Cleaner | NA |
| Avista™177 | Membrane Cleaner | NA |
| Avista™181 | Membrane Cleaner | NA |
| Kuriverter™ IK-110M | Membrane Cleaner | NA |
| ROC 20 N | Membrane Cleaner | NA |
| ROC 50 N | Membrane Cleaner | NA |
| RoClean™ L102 | Membrane Cleaner | NA |
| RoClean™ L112 | Membrane Cleaner | NA |
| RoClean™ L211 | Membrane Cleaner | NA |
| RoClean™ L212 | Membrane Cleaner | NA |
| RoClean™ L403 | Membrane Cleaner | NA |
| RoClean™ L612 | Membrane Cleaner | NA |
| RoClean™ L811 | Membrane Cleaner | NA |
| RoClean™ L904 | Membrane Cleaner | NA |
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| 8333 Coagulant Aid | Coagulation & Flocculation | 250mg/L |
| Kurifloc 2805 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends |
||
| Trade Designation | Product Function | Max Use |
| RoQuest™ 4000 | Coagulation & Flocculation | 142mg/L |
|
Sodium Bisulfite |
||
| Trade Designation | Product Function | Max Use |
| Dechlor 104 | Dechlorinator & Antioxidant | 40mg/L |
|
Sodium Tripolyphosphate |
||
| Trade Designation | Product Function | Max Use |
| 932 Water Conditioner | Corrosion & Scale Control | 13mg/L |
Facility : SHK, USA
|
Miscellaneous Chemical Products[1] |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ P0327 | Membrane Cleaner | NA |
| AvistaClean™ P1219 | Membrane Cleaner | NA |
| AvistaClean™ P611 | Membrane Cleaner | NA |
| AvistaClean™MF 3000 | Membrane Cleaner | NA |
| Avista™ 127 | Membrane Cleaner | NA |
| Avista™ 146 | Membrane Cleaner | NA |
| Avista™ 192 | Membrane Cleaner | NA |
| Avista™ 199 | Membrane Cleaner | NA |
| Avista™ RC P111 | Membrane Cleaner | NA |
| Avista™ RC P112 | Membrane Cleaner | NA |
| Avista™ RC P192 | Membrane Cleaner | NA |
| Avista™ RC P303 | Membrane Cleaner | NA |
| Avista™ RC P611 | Membrane Cleaner | NA |
| Avista™ RC P903 | Membrane Cleaner | NA |
| RoClean™ P111 | Membrane Cleaner | NA |
| RoClean™ P112 | Membrane Cleaner | NA |
| RoClean™ P192 | Membrane Cleaner | NA |
| RoClean™ P303 | Membrane Cleaner | NA |
| RoClean™ P611 | Membrane Cleaner | NA |
| RoClean™ P903 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Treatment Applications |
||
| Trade Designation | Product Function | Max Use |
| AvistaVitec™ 8200 | Reverse Osmosis Antiscalant | 7mg/L |
| Avista™ 200 | Reverse Osmosis Antiscalant | 7mg/L |
| Avista™ VT 8200 | Reverse Osmosis Antiscalant | 7mg/L |
| Kuriverter™ AC-427[2] | Dechlorination | 8mg/L |
| VItec™ SI410 | Reverse Osmosis Antiscalant | 3mg/L |
| VItec™1500 | Reverse Osmosis Antiscalant | 9mg/L |
| VItec™1600 | Reverse Osmosis Antiscalant | 20mg/L |
| Vitec 7400 | Reverse Osmosis Antiscalant | 15mg/L |
| Vitec™ 1000 | Reverse Osmosis Antiscalant | 26mg/L |
| Vitec™ 3000 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 3025 | Reverse Osmosis Antiscalant | 25mg/L |
| Vitec™ 4002 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 6400 | Reverse Osmosis Antiscalant | 20mg/L |
| Vitec™ 6500 | Reverse Osmosis Antiscalant | 20mg/L |
| Vitec™ 8200 | Reverse Osmosis Antiscalant | 7mg/L |
[2] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| 8898 Antiscalant | Reverse Osmosis Antiscalant | 40mg/L |
| Antichlor™ 30[2] | Dechlorination | 15mg/L |
| AvistaRQ™ 6000 | Coagulation & Flocculation | 289mg/L |
| Avista™ RQ3000 | Coagulation & Flocculation | 100mg/L |
| Biotrol 409[4] | Reverse Osmosis Membrane Biocide | 30mg/L |
| RO 510N | Reverse Osmosis Antiscalant | 15mg/L |
| RO 8898 | Reverse Osmosis Antiscalant | 40mg/L |
| RoQuest™ 3000 | Coagulation & Flocculation | 100mg/L |
| RoQuest™ 6000 | Coagulation & Flocculation | 289mg/L |
| Vitec 4000 | Reverse Osmosis Antiscalant | 7mg/L |
| Vitec™ 1400 | Reverse Osmosis Antiscalant | 30mg/L |
| Vitec™ 5100 | Reverse Osmosis Antiscalant | 13mg/L |
| Vitec™ 7000 | Reverse Osmosis Antiscalant | 7mg/L |
[2] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
[4] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products should be
monitored in the finished drinking water to ensure compliance to all applicable
regulations.
|
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AvistaClean™ L0381[1] | Membrane Cleaner | NA |
| AvistaClean™ L1181[1] [3] | Membrane Cleaner | NA |
| AvistaClean™ L1211 NA | Membrane Cleaner | NA |
| AvistaClean™ L1221[1] [3] | Membrane Cleaner | NA |
| Avista™ RC L112 | Membrane Cleaner | NA |
| Avista™ RC L211[1] [3] | Membrane Cleaner | NA |
| Avista™ RC L212[1] [3] | Membrane Cleaner | NA |
| Avista™ RC L403[1] | Membrane Cleaner | NA |
| Avista™ RC L811[1] [3] | Membrane Cleaner | NA |
| Avista™177[1] | Membrane Cleaner | NA |
| Avista™181[1] | Membrane Cleaner | NA |
| ROC 20 N[1] | Membrane Cleaner | NA |
| ROC 50 N[1] | Membrane Cleaner | NA |
| RoClean™ L102[1] [3] | Membrane Cleaner | NA |
| RoClean™ L112 | Membrane Cleaner | NA |
| RoClean™ L211[1] [3] | Membrane Cleaner | NA |
| RoClean™ L212[1] [3] | Membrane Cleaner | NA |
| RoClean™ L403[1] | Membrane Cleaner | NA |
| RoClean™ L612 | Membrane Cleaner | NA |
| RoClean™ L811[1] [3] | Membrane Cleaner | NA |
| RoClean™ L904[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Poly (Diallyldimethylammonium Chloride)(pDADMAC) |
||
| Trade Designation | Product Function | Max Use |
| 8294 Coagulant | Coagulation & Flocculation | 25mg/L |
| Kurifloc 2912 | Coagulation & Flocculation | 25mg/L |
|
Polyacrylamide[PC] |
||
| Trade Designation | Product Function | Max Use |
| 8221 Flocculant | Coagulation & Flocculation | 1mg/L |
| Kurifloc 4330 | Coagulation & Flocculation | 1mg/L |
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| 8333 Coagulant Aid | Coagulation & Flocculation | 250mg/L |
| Kurifloc 2805 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[PY] |
||
| Trade Designation | Product Function | Max Use |
| RoQuest™ 4000 | Coagulation & Flocculation | 142mg/L |
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Sodium Bisulfite[2] |
||
| Trade Designation | Product Function | Max Use |
| Dechlor 104 | Dechlorinator & Antioxidant | 40mg/L |
[2] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
|
Sodium Polyphosphates, Glassy |
||
| Trade Designation | Product Function | Max Use |
| 921 | Corrosion & Scale Control | 12mg/L |
|
Sodium Tripolyphosphate |
||
| Trade Designation | Product Function | Max Use |
| 932 Water Conditioner | Corrosion & Scale Control | 13mg/L |
Number of matching Manufacturers is 1
Number of matching Products is 194