NSF Product and Service Listings
These NSF Official Listings are current as of Sunday, November 2, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=C0483018&Standard=060&
NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| AmeriChemm, LLC | |
| 2913 Highway 71 North | |
| Mena, AR 71953 | |
| United States | |
| 479-394-1692 |
Facility : # 10 USA
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| ACC-120 | Coagulation & Flocculation | 250mg/L |
| ACC-3500 | Coagulation & Flocculation | 250mg/L |
| ACC-8399 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Aluminum Sulfate[AL] |
||
| Trade Designation | Product Function | Max Use |
| ACC-3000 | Coagulation & Flocculation | 400mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Blended Coagulation Chemicals[AL] |
||
| Trade Designation | Product Function | Max Use |
| ACC-8727 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Blended Phosphates |
||
| Trade Designation | Product Function | Max Use |
| Ameri LC-200 | Corrosion & Scale Control | 23mg/L |
| Ameri LC-203 | Corrosion & Scale Control | 18mg/L |
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| ACC-120 | Coagulation & Flocculation | 250mg/L |
| ACC-3500 | Coagulation & Flocculation | 250mg/L |
| ACC-8399 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| 50% Caustic Soda | Corrosion & Scale Control pH Adjustment |
100mg/L |
|
Sodium Hypochlorite[HY] |
||
| Trade Designation | Product Function | Max Use |
| Sodium Hypochlorite 10% | Disinfection & Oxidation | 80mg/L |
| Sodium Hypochlorite 12.5% | Disinfection & Oxidation | 64mg/L |
[HY] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations. Also,
reference the AWWA B300 (Hypochlorites) standard's Recommendations for the Handling and
Storage of Hypochlorite Solutions appendix for information on preservation techniques
for hypochlorite bleach in transit and storage.
|
||
Number of matching Manufacturers is 1
Number of matching Products is 13