NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, October 3, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
14403436 Canada Inc. 
Unit 1-146 West Beaver Creek Road
Richmond Hill, ON L4B 1C2 
Canada 
86 755 8418 3343


Facility : # 1 China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Water Meters
Rhino Water valve (RH-WV2021) 3/4" D. HOT MLTPL
Water Valve model no. (RH-WV1INCH) 1 " D. HOT MLTPL



 
3M / Electrical Markets Division 
3M Center, Building 201-2C-11
St. Paul, MN 55144 
United States 
651-736-9030
Visit this company's website


Facility : Angleton, TX

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 11G[1] >= 1/2" D. HOT PEC
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 4G[1] >= 1/2" D. HOT PEC
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 8G[1] >= 1/2" D. HOT PEC
ScotchKote 134[4] >= 1/2"[5] D. HOT PEC
Scotchkote 206N[2] >= 4" D. HOT PEC
Scotchkote 206N Extra LG[2] >= 4" D. HOT PEC
Scotchkote 206N Fluid Bed[2] >= 4" D. HOT PEC
Scotchkote 206N Long Gel[2] >= 4" D. HOT PEC

[1] Colors: Dark Green
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum thinner: None
    Final Cure Time and Temperature: 6233W 4G: 30-45 seconds at 450°F; 6233W 8G: 60-90
    seconds at 450°F; 6233W 11G: 90-120 seconds at 450°F
    Special Comments: Preheat part to 425° - 488° F before application of powder.
[2] Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 60
    Final Cure Time and Temperature: 206N: 10 minutes at 400°F; 206N Extra LG: 16 minutes at
    400°F; 206N Fluid Bed: 10 minutes at 400°F; 206N Long Gel: 10 minutes at 400°F
[4] Number of Coats: 1
    Sequence of Coats: N/A
    Maximum Field Use Dry Film Thickness (in mils): 60
    Maximum Thinner: None
    Final Cure Time and Temperature: 25 minutes at 425° F
[5] Certified for a maximum surface area to volume ratio of 122.1 sq. in./L for pump end use.

Coatings - Pipe
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 11G[1] >= 1/2" D. HOT PEC
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 4G[1] >= 1/2" D. HOT PEC
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 8G[1] >= 1/2" D. HOT PEC
ScotchKote 134[4] >= 1/2"[5] D. HOT PEC
Scotchkote 206N[2] >= 4" D. HOT PEC
Scotchkote 206N Extra LG[2] >= 4" D. HOT PEC
Scotchkote 206N Fluid Bed[2] >= 4" D. HOT PEC
Scotchkote 206N Long Gel[2] >= 4" D. HOT PEC

[1] Colors: Dark Green
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum thinner: None
    Final Cure Time and Temperature: 6233W 4G: 30-45 seconds at 450°F; 6233W 8G: 60-90
    seconds at 450°F; 6233W 11G: 90-120 seconds at 450°F
    Special Comments: Preheat part to 425° - 488° F before application of powder.
[2] Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 60
    Final Cure Time and Temperature: 206N: 10 minutes at 400°F; 206N Extra LG: 16 minutes at
    400°F; 206N Fluid Bed: 10 minutes at 400°F; 206N Long Gel: 10 minutes at 400°F
[4] Number of Coats: 1
    Sequence of Coats: N/A
    Maximum Field Use Dry Film Thickness (in mils): 60
    Maximum Thinner: None
    Final Cure Time and Temperature: 25 minutes at 425° F
[5] Certified for a maximum surface area to volume ratio of 122.1 sq. in./L for pump end use.

Coatings - Pump
ScotchKote 134[4] [5] D. HOT PEC
Scotchkote 206N[2] [3] >= 2" D. HOT PEC
Scotchkote 206N Extra LG[2] [3] >= 2" D. HOT PEC
Scotchkote 206N Fluid Bed[2] [3] >= 2" D. HOT PEC
Scotchkote 206N Long Gel[2] [3] >= 2" D. HOT PEC

[2] Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 60
    Final Cure Time and Temperature: 206N: 10 minutes at 400°F; 206N Extra LG: 16 minutes at
    400°F; 206N Fluid Bed: 10 minutes at 400°F; 206N Long Gel: 10 minutes at 400°F
[3] Certified for a maximum surface area to volume ratio of 122.1 sq. in./L. for pump end
    use.
[4] Number of Coats: 1
    Sequence of Coats: N/A
    Maximum Field Use Dry Film Thickness (in mils): 60
    Maximum Thinner: None
    Final Cure Time and Temperature: 25 minutes at 425° F
[5] Certified for a maximum surface area to volume ratio of 122.1 sq. in./L for pump end use.

Coatings - Tank
ScotchKote 134[4] >= 5 gal. D. HOT PEC
Scotchkote 206N[2] >= 5 gal. D. HOT PEC
Scotchkote 206N Extra LG[2] >= 5 gal. D. HOT PEC
Scotchkote 206N Fluid Bed[2] >= 5 gal. D. HOT PEC
Scotchkote 206N Long Gel[2] >= 5 gal. D. HOT PEC

[2] Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 60
    Final Cure Time and Temperature: 206N: 10 minutes at 400°F; 206N Extra LG: 16 minutes at
    400°F; 206N Fluid Bed: 10 minutes at 400°F; 206N Long Gel: 10 minutes at 400°F
[4] Number of Coats: 1
    Sequence of Coats: N/A
    Maximum Field Use Dry Film Thickness (in mils): 60
    Maximum Thinner: None
    Final Cure Time and Temperature: 25 minutes at 425° F

Coatings - Valve
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 11G[1] >= 1/2" D. HOT PEC
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 4G[1] >= 1/2" D. HOT PEC
3M Scotchkote Fusion Bonded Epoxy Coating 6233W 8G[1] >= 1/2" D. HOT PEC
ScotchKote 134[4] >= 1/2"[5] D. HOT PEC
Scotchkote 206N[2] >= 2" D. HOT PEC
Scotchkote 206N Extra LG[2] >= 2" D. HOT PEC
Scotchkote 206N Fluid Bed[2] >= 2" D. HOT PEC
Scotchkote 206N Long Gel[2] >= 2" D. HOT PEC

[1] Colors: Dark Green
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum thinner: None
    Final Cure Time and Temperature: 6233W 4G: 30-45 seconds at 450°F; 6233W 8G: 60-90
    seconds at 450°F; 6233W 11G: 90-120 seconds at 450°F
    Special Comments: Preheat part to 425° - 488° F before application of powder.
[2] Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 60
    Final Cure Time and Temperature: 206N: 10 minutes at 400°F; 206N Extra LG: 16 minutes at
    400°F; 206N Fluid Bed: 10 minutes at 400°F; 206N Long Gel: 10 minutes at 400°F
[4] Number of Coats: 1
    Sequence of Coats: N/A
    Maximum Field Use Dry Film Thickness (in mils): 60
    Maximum Thinner: None
    Final Cure Time and Temperature: 25 minutes at 425° F
[5] Certified for a maximum surface area to volume ratio of 122.1 sq. in./L for pump end use.



 
3R Valve, LLC 
29299 Madison Road
Echo, OR 97826 
United States 
541-376-8107
Visit this company's website


Facility : Echo, OR

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Valves [G]
ASR (Aqua System Recovery) Valve[1] 5" - 14" CLD 23 MLTPL

[1] Certified for use in municipal wells in conjunction with a submersible pump. Not
    Certified for residential use.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
4 Sealing Italia SRL 
Vicolo Stretto 2
25030 Rudiano, Brescia 
Italy 
39 391 348 5439
Visit this company's website


Facility : 4 Sealing - Brescia

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Gasket/Sealing Materials
EXX50 [1] C. HOT EPDM
EXX60 [1] C. HOT EPDM
EXX70 [1] C. HOT EPDM
EXX90 [1] C. HOT EPDM
NXX50[2] [1] C. HOT NBR
NXX60[2] [1] C. HOT NBR
NXX70[2] [1] C. HOT NBR
NXX90[2] [1] C. HOT NBR

[1] Certified for a maximum surface area to volume ratio of 2.0 square inches/L.
[2] This product has also been evaluated for use in Mechanical Plumbing Device applications
    with a maximum use restriction of 0.8 square inches/L.

O-Rings
EXX50 [1] C. HOT EPDM
EXX60 [1] C. HOT EPDM
EXX70 [1] C. HOT EPDM
EXX90 [1] C. HOT EPDM
NXX50[2] [1] C. HOT NBR
NXX60[2] [1] C. HOT NBR
NXX70[2] [1] C. HOT NBR
NXX90[2] [1] C. HOT NBR

[1] Certified for a maximum surface area to volume ratio of 2.0 square inches/L.
[2] This product has also been evaluated for use in Mechanical Plumbing Device applications
    with a maximum use restriction of 0.8 square inches/L.



5Elem Hi-Tech Corporation 
No.16, Jiangqin Road
Economic Development Zone 
Jiangyan, Jiangsu 225500 
China 
86 523 8881 5055 
Visit this company's website


Facility : Jiangsu, China

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Pipe
Nordiliner 3/4"-3.5" & 4.5"-12" CLD 23 PUR



 
A. O. Smith Enterprises Ltd. 
768 Erie Street
P.O. Box 310 
Stratford, ON N5A 6T3 
Canada 
519-271-5800


Facility : Stratford, Ontario, Canada

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Pressurized Water Storage Tanks[1] [G]
A O Smith (LPT Prefix) 119 gal. CLD 23 MLTPL
A O Smith ProMax (PM Prefix) 14 - 119 gal. CLD 23 MLTPL
A Y McDonald (16 Prefix) 119 gal. CLD 23 MLTPL
Altamira Pro X/XL 20 - 119 gal. CLD 23 MLTPL
American Water Heater (APT Prefix) 14 - 119 gal. CLD 23 MLTPL
Driller Services (DST/DSI Prefix) >= 65 gal. CLD 23 MLTPL
Global Pump (GPE Prefix) >= 85 gal. CLD 23 MLTPL
Gould Pumps Hydro Pro Water Systems Tanks (V Prefix and MP or PST Suffix) 14 - 20 gal. CLD 23 MLTPL
Gould Pumps Hydro Pro Water Systems Tanks (V Prefix) 14 - 119 gal. CLD 23 MLTPL
PermaTank (SBD/SBDT Prefix) >= 86 gal. CLD 23 MLTPL
Pump Pro (PP Prefix and MP or PST Suffix) 14 - 20 gal. CLD 23 MLTPL
Pump Pro (PP Prefix) >= 14 gal. CLD 23 MLTPL
Reliance (PMD Prefix) 119 gal. CLD 23 MLTPL
State (MPT Prefix & SSB Prefix) >= 85 gal. CLD 23 MLTPL
Trident (TD Prefix and MP or PST Suffix) 14 - 20 gal. CLD 23 MLTPL
Trident Ultra (TDU Prefix and MP or PST Suffix ) >= 14 gal. CLD 23 MLTPL
Trident Ultra (TDU and TD Prefix) >= 14 gal. CLD 23 MLTPL
Xylem CentriPro T Water Sytem Tanks 14 - 119 gal. CLD 23 MLTPL
Xylem CentriPro TP Water Systems Tanks 14 - 119 gal. CLD 23 MLTPL
Xylem Hydro Pro Water System Tanks (V Prefix) 14 - 119 gal. CLD 23 MLTPL
Xylem Hydro Pro Water System Tanks (V prefix and MP or PST suffix) 14 - 20 gal. CLD 23 MLTPL

[1] Product also complies with NSF/ANSI 372.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Thermal Expansion Tanks[1] [G]
Bell and Gossett (Prefix PT)[2] 14 - 86 gal. D. HOT MLTPL

[1] Product also complies with NSF/ANSI 372.
[2] Suffixes:
    blank 
    B   - Buried 
    EX  - Base extension 
    MP  - Mounted pump 
    P   - Pipe mounted 
    PST - Pump system tank
    S
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
A. W. Chesterton Co. 
860 Salem Street
Groveland, MA 01834 
United States 
978-469-6446


Facility : Groveland, MA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Miscellaneous Process Devices/Components[1]
150 Non-Split Cartridge Seal[G] [2] D. HOT MLTPL
1510 Non-Split Cartridge Seal[G] [2] D. HOT MLTPL
155 Non-Split Cartridge Seal[G] [2] D. HOT MLTPL
1725A[3] [G] D. HOT PTFE
180 Non-Split Cartridge Seal[G] [2] D. HOT MLTPL
1810 Non-Split Cartridge Seal[G] [2] D. HOT MLTPL
442 Split Mechanical Seal[G] [2] D. HOT MLTPL
442C Split Mechanical Seal[G] [2] D. HOT MLTPL
S10 Non-Split Cartridge Seal[G] [2] D. HOT MLTPL
Single Non-Split Cartridge Seals[G] [2] D. HOT MLTPL
Spare Part Kit (SPK)[G] [2] D. HOT MLTPL

[1] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[2] Certified for mechanical seals for use with pump shafts ranging from 1" - 12" in
    diameter.  Certified for equivalent metric sizes.
[3] Certified for use as a packing material in pumps with shaft diameters >= 0.625".
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings
ARC S1 PW BLU[1] >= 1/2" CLD 23 EPOXY
ARC S1 PW HB WH[2] >= 18" CLD 23 EPOXY
ARC S1 PW WH[1] >= 1/2" CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume
[2] Colors: White
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): 240 (80 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume. Minimum mil thickness is 1
    coat at 80 mils.

Coatings - Pump
ARC S1 PW BLU[1] >= 1/2" CLD 23 EPOXY
ARC S1 PW WH[1] >= 1/2" CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume

Coatings - Pipe
ARC S1 PW BLU[1] >= 1/2" CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume
[2] Colors: White
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): 240 (80 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume. Minimum mil thickness is 1
    coat at 80 mils.

Coatings - Valve
ARC S1 PW WH[1] >= 1/2" CLD 23 EPOXY
ARC S1 PW BLU[1] >= 1/2" CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume

Coatings - Pipe
ARC S1 PW HB WH[2] >= 18" CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume
[2] Colors: White
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): 240 (80 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume. Minimum mil thickness is 1
    coat at 80 mils.

Coatings - Tank
ARC S1 PW HB WH[2] >= 1,500 gal. CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume
[2] Colors: White
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): 240 (80 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume. Minimum mil thickness is 1
    coat at 80 mils.

Coatings - Pipe
ARC S1 PW WH[1] >= 1/2" CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume
[2] Colors: White
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): 240 (80 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume. Minimum mil thickness is 1
    coat at 80 mils.

Coatings - Tank
ARC S1 PW BLU[1] >= 1,500 gal. CLD 23 EPOXY
ARC S1 PW WH[1] >= 1,500 gal. CLD 23 EPOXY

[1] Colors: Blue, White
    Number of coats: 3
    Maximum field use dry film thickness (in mils): 45 (15 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume
[2] Colors: White
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): 240 (80 mils/coat)
    Recoat cure time and temperature: 6 hours at 77°F
    Final cure time and temperature: 7 days at 77°F
    Special Comments: Mix ratio of Part A:B is 2:1 by volume. Minimum mil thickness is 1
    coat at 80 mils.



 
A. W. Chesterton Co. 
860 Salem Street
Groveland, MA 01834 
United States 
978-469-6446
Visit this company's website


Facility : # 1 USA

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Patching Materials
ARC 5ES [1] C. HOT EPOXY

[1] The exposed surface area of each sealant in a household distribution system
    should not exceed 1.3 sq. cm/L or .2 sq. in/L.



 
A.O. Smith Su Teknolojileri A.S. 
Ikitelli O.S.B.Mh.Marmara D Blok Sk.
No:2-3, Küçükçekmece-Ikitelli 
34303 Istanbul 
Türkiye 
90 212 444 1646
Visit this company's website


Facility : # 3 China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Reverse Osmosis Element[1] [2] [3]
BW-4040 4" x 40" CLD 23 MLTPL
BW-8040 8" x 40" CLD 23 MLTPL
ULP-4021 4" x 21" CLD 23 MLTPL
ULP-4040 4" x 40" CLD 23 MLTPL
ULP-4040HR 4" x 40" CLD 23 MLTPL
ULP-4040MR 4" x 40" CLD 23 MLTPL
ULP-8040 8" x 40" CLD 23 MLTPL

[1] Size is expressed as Diameter x length.
[2] BW-8040 and ULP-8040 models are Certified for a minimum daily flow of 10000 gallons.
    BW-4040 model is Certified for a minimum daily flow of 2400 gallons.
    ULP-4040 model is Certified for a minimum daily flow of 2600 gallons.
    ULP-4040MR model is Certified for a minimum daily flow of 2200 gallons.
    ULP-4040HR model is Certified for a minimum daily flow of 1800 gallons.
    ULP-4021 model is Certified for a minimum daily flow of 950 gallons.
[3] Models require the following flushing procedure:
    BW-4040, ULP-4040, ULP-4040MR, ULP-4040HR and ULP-4021 require a 4 gpm flush for 24
    hours using tap water.
    BW-8040 and ULP-8040 require a 15 gpm flush for 24 hours using tap water.



 
A.R. Thomson Group 
3420 189th Street
Surrey, BC V3Z 1A7 
Canada 
604-507-6050
Visit this company's website


Facility : # 1 Canada

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Gasket/Sealing Materials
Thomson 4500 >= 3" CLD 23 EPDM
Thomson MultiPac 6000 [1] C. HOT OTHER
Thomson MultiPac 6000 [2] CLD 23 OTHER

[1] Certified for a maximum surface area to volume ratio of 0.3 sq. in./L when used at
    Commercial Hot (82°C) temperature.
[2] Certified for a maximum surface area to volume ratio of 0.8 sq. in./L when used at Cold
    (23°C) temperature.



 
A.R. Thomson Group Inc. 
3420 189th Street
Surrey, BC V32 1A7 
Canada 
604-507-6050
Visit this company's website


Facility : # 1 Canada

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Gasket/Sealing Materials
Thomson Multipac-6000 [1] C. HOT OTHER
Thomson Multipac-6000 [2] CLD 23 OTHER

[1] Certified for a maximum surface area to volume ratio of 0.3 sq. in./L when used at
    Commercial Hot (82°C) temperature.
[2] Certified for a maximum surface area to volume ratio of 0.8 sq. in./L when used at Cold
    (23°C) temperature.



 
A.T. Gomma Guarnizioni Industriali S.R.L. 
Via Mearolo, 3/D
24060 Foresto Sparso 
Italy 
39 035 930 254
Visit this company's website


Facility : Foresto Sparso, Italy

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Gasket/Sealing Materials[1] [G]
EX70LC (EPDM 70 PEROX) [2] C. HOT EPDM

[1] This product has also been evaluated for use in Mechanical Plumbing Device applications
    with a maximum use restriction of 2.0 square inches/L.
[2] Certified for a maximum surface area to volume ration of 2.0 square inches/L.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

O-Rings[1] [G]
EX70LC (EPDM 70 PEROX) [2] C. HOT EPDM

[1] This product has also been evaluated for use in Mechanical Plumbing Device applications
    with a maximum use restriction of 2.0 square inches/L.
[2] Certified for a maximum surface area to volume ration of 2.0 square inches/L.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
A.T.P. Avanzate Tecnologie Plastiche SRL 
Via dell'Industria, 3
76121 Barletta (BT) 
Italy 
39 08 835 33167
Visit this company's website


Facility : Barletta (BT), Italy

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Service Saddles[1] [G]
TORO 25 63 mm - 250 mm D. HOT MLTPL

[1] Saddle PN25
    SDL 6320 (63 x 20 mm)
    SDL 6325 (63 x 25 mm)
    SDL 6332 (63 x 32 mm)
    SDL 7520 (75 x 20 mm)
    SDL 7525 (75 x 25 mm)
    SDL 7532 (75 x 32 mm)
    SDL 9025 (90 x 25 mm)
    SDL 9032 (90 x 32 mm)
    SDL 9040 (90 x 40 mm)
    SDL 11032 (110 x 32 mm)
    SDL 11040 (110 x 40 mm)
    SDL 11050 (110 x 50 mm)
    SDL 12540 (125 x 40 mm)
    SDL 12550 (125 x 50 mm)
    SDL 12563 (125 x 63 mm)
    SDL 16040 (160 x 40 mm)
    SDL 16050 (160 x 50 mm)
    SDL 16063 (160 x 63 mm)
    SDL 20050 (200 x 50 mm)
    SDL 20063 (200 x 63 mm)
    SDL 20075 (200 x 75 mm)
    SDL 20090 (200 x 90 mm)
    SDL 25063 (250 x 63 mm)
    SDL 25075 (250 x 75 mm)
    SDL 25090 (250 x 90 mm)
    SDL 250110 (250 x 110 mm)
       
    Threaded Saddle PN25
    SDF 6320 (63 mm x 1/2")
    SDF 6325 (63 mm x 3/4")
    SDF 7520 (75 mm x 1/2")
    SDF 7525 (75 mm x 3/4")
    SDF 9020 (90 mm x 1/2")
    SDF 9025 (90 mm x 3/4")
    SDF 11020 (110 mm x 1/2")
    SDF 11025 (110 mm x 3/4")
    SDF 11032 (110 mm x 1")
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings[1] [2] [G]
TORO 25 20 mm - 250 mm D. HOT PP

[1] Configurations include:
        
    Swan Neck PN20
    SOP 20 A20 (20 x 20 mm)
    SOP 25 A20 (25 x 25 mm)
    SOP 32 A20 (32 x 32 mm)
         
    Swan Neck Female - Female PN25
    SFF 2020 (20 x 20 mm)
    SFF 2525 (25 x 25 mm)
      
    Swan Neck Short Female - Female PN25
    SFC 2020 (20 x 20 mm)
    SFC 2525 (25 x 25 mm) 
       
    Socket PN25
    MAN 20 (20 x 20 mm)
    MAN 25 (25 x 25 mm)
    MAN 32 (32 x 32 mm)
    MAN 40 (40 x 40 mm)
    MAN 50 (50 x 50 mm)
    MAN 63 (63 x 63 mm)
    MAN 75 (75 x 75 mm)
    MAN 90 (90 x 90 mm)
    MAN 110 (110 x 110 mm)
    MAN 125 (125 x 125 mm)
    MAN 160 (160 x 160 mm)
    
    90° Elbow PN25
    CUV 20 (20 x 20 mm)
    CUV 25 (25 x 25 mm)
    CUV 32 (32 x 32 mm)
    CUV 40 (40 x 40 mm)
    CUV 50 (50 x 50 mm)
    CUV 63 (63 x 63 mm)
    CUV 75 (75 x 75 mm)
    CUV 90 (90 x 90 mm)
    CUV 110 (110 x 110 mm)
    CUV 125 (125 x 125 mm)
    CUV 160 (160 x 160 mm)
    CUV 160 T (160 x 160 mm)
    CUV 200 T (200 x 200 mm)
    CUV 250 T (250 x 250 mm)
        
    45° Elbow PN25
    CUQ 20 (20 x 20 mm)
    CUQ 25 (25 x 25 mm)
    CUQ 32 (32 x 32 mm)
    CUQ 40 (40 x 40 mm)
    CUQ 50 (50 x 50 mm)
    CUQ 63 (63 x 63 mm)
    CUQ 75 (75 x 75 mm)
    CUQ 90 (90 x 90 mm)
    CUQ 110 (110 x 110 mm)
    CUQ125 (125 x 125 mm)
    CUQ 160 (160 x 160 mm)
    CUQ 160 T (160 x 160 mm)
    CUQ 200 T (200 x 200 mm)
    CUQ 250 T (250 x 250 mm)
      
    90° Elbow M/F PN25
    CMF 20 (20 x 20 mm)
    CMF 25 (25 x 25 mm)
      
    Reduced 90° Elbow PN25
    CUR 2520 (25 x 20 mm)
    CUR 3220 (32 x 20 mm)
    CUR 3225 (32 x 25 mm)
      
    Reducing Bush M/F PN25
    RDZ 2520 (25 x 20 mm)
    RDZ 3220 (32 x 20 mm)
    RDZ 3225 (32 x 25 mm)
    RDZ 4020 (40 x 20 mm)
    RDZ 4025 (40 x 25 mm)
    RDZ 4032 (40 x 32 mm)
    RDZ 5020 (50 x 20 mm)
    RDZ 5025 (50 x 25 mm)
    RDZ 5032 (50 x 32 mm)
    RDZ 5040 (50 x 40 mm)
    RDZ 6320 (63 x 20 mm)
    RDZ 6325 (63 x 25 mm)
    RDZ 6332 (63 x 32 mm)
    RDZ 6340 (63 x 40 mm)
    RDZ 6350 (63 x 50 mm)
       
    Reducing Bush F/F PN25
    RDF 2520 (25 x 20 mm)
    RDF 3220 (32 x 20 mm)
    RDF 3225 (32 x 25 mm)
    RDF 4020 (40 x 20 mm)
    RDF 4025 (40 x 25 mm)
    RDF 4032 (40 x 32 mm)
    RDF 5020 (50 x 20 mm)
    RDF 5025 (50 x 25 mm)
    RDF 5032 (50 x 32 mm)
    RDF 5040 (50 x 40 mm)
    RDF 6320 (63 x 20 mm)
    RDF 6325 (63 x 25 mm)
    RDF 6332 (63 x 32 mm)
    RDF 6340 (63 x 40 mm)
    RDF 6350 (63 x 50 mm)
    RDF 7540 (75 x 40 mm)
    RDF 7550 (75 x 50 mm)
    RDF 7563 (75 x 63 mm)
    RDF 9050 (90 x 50 mm)
    RDF 9063 (90 x 63 mm)
    RDF 9075 (90 x 75 mm)
    RDF 11063 (110 x 63 mm)
    RDF 11075 (110 x 75 mm)
    RDF 11090 (110 x 90 mm)
    RDF 125110 (125 x 110 mm)
    RDF 160110 (160 x 110 mm)
    RDF 160125 (160 x 125 mm)
    RDT 200 160 (200 x 160 mm)
    RDT 250 200 (250 x 200 mm)
    RDT 250 160 (250 x 160 mm)
    
    Cap PN25
    TAC 20 (20 mm)
    TAC 25 (25 mm)
    TAC 32 (32 mm)
    TAC 40 (40 mm)
    TAC 50 (50 mm)
    TAC 63 (63 mm)
    TAC 75 (75 mm)
    TAC 90 (90 mm)
    TAC 110 (110 mm)
    TAC 125 (125 mm)
    TAC 160 T (160 mm)
    TAC 200 T (200 mm)
    TAC 250 T (250 mm)
       
    Tee PN25
    TEN 20 (20 x 20 x 20 mm)
    TEN 25 (25 x 25 x 25 mm)
    TEN 32 (32 x 32 x 32 mm)
    TEN 40 (40 x 40 x 40 mm)
    TEN 50 (50 x 50 x 50 mm)
    TEN 63 (63 x 63 x 63 mm)
    TEN 75 (75 x 75 x 75 mm)
    TEN 90 (90 x 90 x 90 mm)
    TEN 110 (110 x 110 x 110 mm)
    TEN 125 (125 x 125 x 125 mm)
    TEN 160 (160 x 160 x 160 mm)
    TEN 160 T (160 x 160 x 160 mm)
    TEN 200 T (200 x 200 x 200 mm)
    TEN 250 T (250 x 250 x 250 mm)
    
    Reducing Tee PN25
    TER 2520 (25 x 20 x 25 mm)
    TER 2521 (25 x 20 x 20 mm)
    TER 3220 (32 x 20 x 32 mm)
    TER 3225 (32 x 25 x 32 mm)
    TER 4020 (40 x 20 x 40 mm)
    TER 4025 (40 x 25 x 40 mm)
    TER 4032 (40 x 32 x 40 mm)
    TER 5020 (50 x 20 x 50 mm)
    TER 5025 (50 x 25 x 50 mm)
    TER 5032 (50 x 32 x 50 mm)
    TER 5040 (50 x 40 x 50 mm)
    TER 6320 (63 x 20 x 63 mm)
    TER 6325 (63 x 25 x 63 mm)
    TER 6332 (63 x 32 x 63 mm)
    TER 6340 (63 x 40 x 63 mm)
    TER 6350 (63 x 50 x 63 mm)
    TER 7540 (75 x 40 x 75 mm)
    TER 7550 (75 x 50 x 75 mm)
    TER 7563 (75 x 63 x 75 mm)
    TER 9050 (90 x 50 x 90 mm)
    TER 9063 (90 x 63 x 90 mm)
    TER 9075 (90 x 75 x 90 mm)
    TER 11063 (110 x 63 x 110 mm)
    TER 11075 (110 x 75 x 110 mm)
    TER 11090 (110 x 90 x 110 mm)
    TER 125110 (125 x 110 x 125 mm)
    TER 160110 (160 x 110 x 160 mm)
       
    Cross PN25
    TEQ 20 (20 x 20 x 20 x 20 mm)
        
    Union PN10
    UNI 2020 (20 x 20 mm)
    UNI 2525 (25 x 25 mm)
    UNI 3232 (32 x 32mm)
    UNI 4040 (40 x 40 mm)
    UNI 5050 (50 x 50 mm)
    UNI 6363 (63 x 63 mm)
[2] Stub End
    CTL 32 (32 mm)
    CTL 40 (40 mm)
    CTL 50 (50 mm)
    CTL 63 (63 mm)
    CTL 75 (75 mm)
    CTL 90 (90 mm)
    CTL 110 (110 mm)
    CTL 125 (125 mm)
    CTL 160 (160 mm)
    CTL 160 T (160 mm)
    CTL 200 T (200 mm)
    CTL 250 T (250 mm)
       
    Electrofusion Socket
    MAE 63 (63 x 63 mm)
    MAE 75 (75 x 75 mm)
    MAE 90 (90 x 90 mm)
    MAE 110 (110 x 110 mm)
    MAE 125 (125 x 125 mm)
    MAE 160 (160 x 160 mm)
    MAE 200 (200 x 200 mm)
    MAE 250 (250 x 250 mm)
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings, Non-Repeating[3] [G]
TORO 25 20 mm - 110 mm D. HOT PP

[3] Configurations include:
        
    Male Adapter Threaded Female PN25
    GFF 3220 (32 mm x 1/2")
        
    90° Threaded Elbow PN25 - Female
    CFF 2020 (20 mm x 1/2")
    CFF 2025 (20 mm x 3/4")
    CFF 2520 (25 mm x 1/2")
    CFF 2525 (25 mm x 3/4")
    CFF 3225 (32 mm x 3/4")
    CFF 3232 (32 mm x 1")
        
    90° Threaded Elbow PN25 - Male
    CFM 2020 (20 mm x 1/2")
    CFM 2025 (20 mm x 3/4")
    CFM 2520 (25 mm x 1/2")
    CFM 2525 (25 mm x 3/4")
    CFM 3225 (32 mm x 3/4")
    CFM 3232 (32 mm x 1")
        
    90° Long Threaded Elbow PN25 - Female
    CFL 2020 (20 mm x 1/2")
    CFL 2520 (25 mm x 1/2")
       
    90° Threaded Elbow with Bracket PN25 - Female
    FFS 2020 (20mm x 1/2")
    FFS 2520 (25 mm x 1/2")
    
    90° Threaded Elbow with Bracket PN25 - Male
    FMS 2020 (20 mm x 1/2")
    FMS 2520 (25 mm x 1/2")
       
    90° Threaded Elbow PN25 - Female with Male
    CCF 2020 (20 mm x 1/2")
       
    90° Threaded Elbow PN25 - Male with Male
    CCM 2020 (20 mm x 1/2")
        
    Threaded Tee PN25 - Female
    TEF 2020 (20 mm x 1/2" x 20 mm)
    TEF 2025 (20 mm x 3/4" x 20 mm)
    TEF 2520 (25 mm x 1/2" x 25 mm)
    TEF 2525 (25 mm x 3/4" x 25 mm)
    TEF 3225 (32 mm x 3/4" x 32 mm)
    TEF 3232 (32 mm x 1" x 32 mm)
       
    Threaded Tee PN25 - Male
    TEM 2020 (20 mm x 1/2" x 20 mm)
    TEM 2025 (20 mm x 3/4" x 20 mm)
    TEM 2520 (25 mm x 1/2" x 25 mm)
    TEM 2525 (25 mm x 3/4" x 25 mm)
    TEM 3225 (32 mm x 3/4" x 32 mm)
    TEM 3232 (32 mm x 1" x 32 mm)
    
    Threaded Coupling PN25 - Female
    RFF 2020 (20 mm x 1/2")
    RFF 2025 (20 mm x 3/4")
    RFF 2520 (25 mm x 1/2")
    RFF 2525 (25 mm x 3/4")
    RFF 3225 (32 mm x 3/4")
    RFF 3232 (32 mm x 1")
    RFF 4040 (40 mm x 1-1/4")
    RFF 5050 (50 mm x 1-1/2")
    RFF 6363 (63 mm x 2")
    RFF 7575 (75 mm x 2-1/2")
    RFF 9090 (90 mm x 3")
    RFF 110110 (110 mm x 4")
    
    Threaded Coupling PN25 - Male
    RFM 2020 (20 mm x 1/2")
    RFM 2025 (20 mm x 3/4")
    RFM 2520 (25 mm x 1/2")
    RFM 2525 (25 mm x 3/4")
    
    Fixed Wall Assembly Group
    GVF 2020 (20 mm x 1/2")
    GVF 2520 (25 mm x 1/2")
        
    Brass Adapter PN25 - Female
    GGF 2020 (20 mm x 1/2")
    GGF 2525 (25 mm x 3/4")
    GGF 3232 (32 mm x 1")
    GGF 4040 (40 mm x 1-1/4")
    GGF 5050 (50 mm x 1-1/2")
    GGF 6363 (63 mm x 2")
       
    Brass Adapter PN25 - Male
    GGM 2020 (20 mm x 1/2")
    GGM 2525 (25 mm x 3/4")
    GGM 3232 (32 mm x 1")
    GGM 4040 (40 mm x 1-1/")
    GGM 5050 (50 mm x 1-1/2")
    GGM 6363 (63 mm x 2")
    RFM 3225 (32 mm x 3/4")
    RFM 3232 (32 mm x 1")
    RFM 4040 (40 mm x 1-1/4")
    RFM 5050 (50 mm x 1-1/2")
    RFM 6363 (63 mm x 2")
    RFM 7575 (75 mm x 2-1/2")
    RFM 9090 (90 mm x 3")
    RFM 110110 (110 mm x 4")
       
    Wall Assembly Group
    GVS 2020 (1/2" x 1/2")
        
    Wall Assembly Group with Template
    GVD 2020 (20 mm x 1/2")
    GVD 2520 (25 mm x 1/2")
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe[4] [G]
TORO 25 20 mm - 250 mm D. HOT PP

[4] Pipe models include:
    
    FIBER Pipe
    TUB 20 SDR6 F
    TUB 25 SDR6 F
    
    FIBER EVO Pipe
    TUB 32 SDR9 FE
    TUB 40 SDR9 FE
    TUB 50 SDR9 FE
    TUB 63 SDR9 FE
    TUB 75 SDR9 FE
    TUB 90 SDR9 FE
    TUB 110 SDR9 FE
    TUB 125 SDR9 FE
    TUB 160 SDR9 FE
    TUB 200 SDR9 FE
    TUB 250 SDR9 FE
    TUB 20 SDR7.4 FE
    TUB 25 SDR7.4 FE
    TUB 32 SDR7.4 FE
    TUB 40 SDR7.4 FE
    TUB 50 SDR7.4 FE
    TUB 63 SDR7.4 FE
    TUB 75 SDR7.4 FE
    TUB 90 SDR7.4 FE
    TUB 110 SDR7.4 FE
    TUB 125 SDR7.4 FE
    TUB 160 SDR7.4 FE
    TUB 200 SDR7.4 FE
    TUB 250 SDR7.4 FE
    TUB 32 SDR11 FE
    TUB 40 SDR11 FE
    TUB 50 SDR11 FE
    TUB 63 SDR11 FE
    TUB 75 SDR11 FE
    TUB 90 SDR11 FE
    TUB 110 SDR11 FE
    TUB 125 SDR11 FE
    TUB 160 SDR11 FE
    TUB 200 SDR11 FE
    TUB 250 SDR11 FE
    TUB 160 SDR17 FE
    TUB 200 SDR17 FE
    TUB 250 SDR17 FE
      
    PPR Pipe
    TUB X A10 - PN10 - SDR11/S5 (20 – 63 mm)
    TUB X A16 - PN16 - SDR7.4/S3.2 (20 – 63 mm)
    TUB X A20 - PN20 - SDR6/S2.5 (20 – 63 mm)
      
    EvO Pipe
    TUB X A10 E - PN10 - SDR17/S8 (75 – 250 mm)
    TUB X A16 E - PN16 - SDR11/S5 (75 – 250 mm)
    TUB X A20 E - PN20 - SDR7.4/S3.2 (75 – 160 mm)
    TUB X A20 E - PN20 - SDR9/S4 (200 – 250 mm)
    TUB X A25 E - PN25 - SDR6/S2.5 (20 – 160 mm)
      
    X corresponds to the size in mm.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
A.U.K. Müller GmbH & Co. KG 
Dresdener Str. 162
D-40595 Düsseldorf 
Germany 
49 21 173 910
Visit this company's website


Facility : Düsseldorf, Germany

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Solenoid Valves[G]
10.009.115 Solenoid 3/4" C. HOT MLTPL
10.009.126 Solenoid 3/4" C. HOT MLTPL
62.005.115 Solenoid 3/4" C. HOT MLTPL
62.005.126 Solenoid 3/4" C. HOT MLTPL
62.005.815 Solenoid 3/4" C. HOT MLTPL
62.005.826 Solenoid 3/4" C. HOT MLTPL
62.007.115 Solenoid 3/4" C. HOT MLTPL
62.007.126 Solenoid 3/4" C. HOT MLTPL
62.009.115 Solenoid 3/4" C. HOT MLTPL
62.009.126 Solenoid 3/4" C. HOT MLTPL

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Valves[G]
52.009.100 3/4" C. HOT MLTPL
52.009.200 3/4" C. HOT MLTPL

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Mechanical Plumbing Devices

Trade Designation      

Faucet Cartridges[G] [Q]
50.005.800      
50.005.801      
50.005.811      
50.007.801      
50.007.811      
50.009.101      
50.009.801      
50.009.811      
51.005.101 Cartridge Valve      
51.005.101 Cartridge Valve      
T01 50.009.800      
T02 50.009.800      

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

Solenoid Valves[G]
50.005.102 Cartridge Valve[Q]      
50.005.126 bistable 2/2-way solenoid valve[2]      

[2] This product does not require a Q statistic. It is made from material or materials that
    do not require lead analysis when reviewed per NSF/ANSI/CAN Standard 61, Section 3.3.
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Valves[G] [Q]
50.005.100 Cartridge Valve      
50.005.850      
50.007.101      
50.007.806 Solenoid Cartridge Valve[1]      
51.005.100      
51.005.125      

[1] Certified for models that include: 
    G 1/2 male threads 
    G 3/8 male threaded with G 3/8 female threads 
    G 3/8 male threaded with G 1/2 female threads 
    Model with sockets for customer provided fitting adapters.

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings [G]
CF-13 2MFC[1] 3/4" x 3/4" x 3/4" D. HOT MLTPL
CF-13 2MFO[1] 1/2" x ¾" x ¾" x ¾" D. HOT MLTPL
CF-17 2MFC[1] 3/4" C. HOT MLTPL
CF-17 2MFO[1] 3/4" C. HOT MLTPL
CF-17 3MFC[1] 3/4" C. HOT MLTPL
CF-17 3MFO[1] 3/4" C. HOT MLTPL
CF-17 C (cross piece)[1] 3/4" C. HOT MLTPL
CF-17 L (L-piece)[1] 3/4" C. HOT MLTPL
CF-17 T (T-piece)[1] 3/4" C. HOT MLTPL
CF-H G Connector 3/4"x1/8"-3/4"x1/4" C. HOT MLTPL
CF-H L 90 deg Elbow Connector 3/4" x 1/2" C. HOT MLTPL
CF-H S Straight Connector 3/4"x3/8"-3/4"x1/2" C. HOT MLTPL

[1] MFC - are models with capped outlets
    MFO - are models without capped outlets
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
A.W. Cook Cement Products, Inc. 
242 Amy Industrial Lane
Hoschton, GA 30548 
United States 
706-654-3677


Facility : Hoschton, GA

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings[1]
Cemtec Silatec PW >= 6" CLD 23 CMNT

[1] Coating Notes:
    Color: Gray
    Number of Coats: 2 - 4
    Maximum Field Use Dry Thickness (in mils): 2000 mils
    Recoat Cure Time and Temperature: 1 hour at 75°F
    Final Cure Time/Temperature: 7 days @ 75°F
    Special Comments: Mix ratio is 4 quarts of water to one 60 lb bag of Cemtec Silatec PW. 
    Ensure proper surface preparation guidelines are followed prior to installation.

Coatings - Pipe[1]
Cemtec Silatec PW >= 48" CLD 23 CMNT

[1] Coating Notes:
    Color: Gray
    Number of Coats: 2 - 4
    Maximum Field Use Dry Thickness (in mils): 2000 mils
    Recoat Cure Time and Temperature: 1 hour at 75°F
    Final Cure Time/Temperature: 7 days @ 75°F
    Special Comments: Mix ratio is 4 quarts of water to one 60 lb bag of Cemtec Silatec PW. 
    Ensure proper surface preparation guidelines are followed prior to installation.

Coatings - Tank[1]
Cemtec Silatec PW >= 10,000 gal. CLD 23 CMNT

[1] Coating Notes:
    Color: Gray
    Number of Coats: 2 - 4
    Maximum Field Use Dry Thickness (in mils): 2000 mils
    Recoat Cure Time and Temperature: 1 hour at 75°F
    Final Cure Time/Temperature: 7 days @ 75°F
    Special Comments: Mix ratio is 4 quarts of water to one 60 lb bag of Cemtec Silatec PW. 
    Ensure proper surface preparation guidelines are followed prior to installation.



 
A.Y. McDonald Manufacturing 
4800 Chavenelle Road
Dubuque, IA 52001 
United States 
563-583-7311


Facility : Santa Fe Springs, CA

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings
Copper Alloy Press-Connect Pressure Fittings 1/8" - 2 C. HOT BRASS

[1] Certified for the following configurations:
    90º Elbow Drop Ear PXF 1/2" x 3/8" - 1" x 1"
    90º Elbow Brass PXF 1/2" X 3/8" - 2" x 2"
    90º Elbow HI Ear PXF 1/2"
    Elbow Double Drop PXPXF 1/2" - 3/4"
    Union PxP 1/2" - 2"
    Union PxF 1/2" - 2"
    Union PxM 1/2" - 2"
    Vent Elbow PXPXF 1/2" x 1/2" x 1/8" - 3/4" x 3/4" x 1/8"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Facility : Kyunggi-Do, Republic of Korea

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings[1] [G]
Copper Press-connect Pressure Fittings 1/2" - 4" C. HOT MLTPL

[1] Certified for the following configurations:
    90º Elbow PXP 1/2" - 4"
    90º Elbow FtgXP 1/2" - 4"
    Short Turn 90° Elbow PXP 1/2" - 4"
    Short Turn 90° Elbow FtgXP 1/2" - 4"
    45º Elbow PXP 1/2" - 4"
    45º Elbow FtgXP 1/2" - 4"
    Short Turn 45° Elbow PXP 1/2" - 4"
    Short Turn 45° Elbow FtgXP 1/2" - 4"
    Cap 1/2" - 4"
    Adapter PXF 1/2" - 4"
    Adapter PxM 1/2" - 4"
    Roll Stop Coupling PXP 1/2" - 4"
    No Stop Coupling PXP 1/2" - 4"
    With Stop Coupling 1/2" - 4"
    Reducing Coupling PXP 3/4" x 1/2" - 4" x 3"
    Reducing Coupling FtgXP 3/4" x 1/2" - 4" x 3"
    Tee PXPXP 1/2" - 4"
    Crossover PXP 1/2" - 3/4"
    Crossover FtgXP 1/2" - 3/4"
    Extended Coupling PXP 1/2" - 2"
    Adapter Ftg x F 1/2" - 2"
    Adapter Ftg x M 1/2" - 2"
    90° ELBOW P x F 1/2" - 2"
    90° ELBOW P x M 1/2" - 2"
    90° EXTENDED STREET ELBOW P x Ftg 3/4"
    TEE P x P x F 1/2" - 4"
    Adapter Flange P x Flange (4BOLT) 1/2" - 4"
    Adapter Flange P x Flange (8BOLT) 2 1/2" - 4"
    MANIFOLDS P x P 1" x 1/2" - 1" x 3/4"
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
AAG - All American Gasket 
291 Howard St.
Brockton, MA 02302 
United States 
508-588-7500


Facility : Brockton, MA

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Gasket/Sealing Materials[1] [G]
EP61 [2] C. HOT EPDM

[1] This product has also been evaluated for use in Mechanical Plumbing Device applications
    with a maximum use restriction of 0.2 square inches/L.
[2] Certified for a maximum surface area to volume ratio of 2.0 square inches/L.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

O-Rings[1] [G]
EP61 [2] C. HOT EPDM

[1] This product has also been evaluated for use in Mechanical Plumbing Device applications
    with a maximum use restriction of 0.2 square inches/L.
[2] Certified for a maximum surface area to volume ratio of 2.0 square inches/L.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Aalberts Integrated Piping Systems Americas, Inc. DBA Conbraco Industries, Inc. 
1418 South Pearl Street
Pageland, SC 29728 
United States 
704-841-6000


Facility : # 1 China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Valves[1] [2] [G]
215L YY SSP8TAX 2" - 48" CLD 23 MLTPL
215LYYBBB8TAX 2" - 48" CLD 23 MLTPL
215LYYJJJ8TAX 2" - 48" CLD 23 MLTPL
215LYYKKK8TAX 2" - 48" CLD 23 MLTPL
215LYYSSS8TAX 2" - 48" CLD 23 MLTPL
215W YY SSP8TAX 2" - 48" CLD 23 MLTPL
215WYYBBB8TAX 2" - 48" CLD 23 MLTPL
215WYYJJJ8TAX 2" - 48" CLD 23 MLTPL
215WYYKKK8TAX 2" - 48" CLD 23 MLTPL
215WYYSSS8TAX 2" - 48" CLD 23 MLTPL
230L YY SSP8TAX 2" - 48" CLD 23 MLTPL
230LYYBBB8TAX 2" - 48" CLD 23 MLTPL
230LYYJJJ8TAX 2" - 48" CLD 23 MLTPL
230LYYKKK8TAX 2" - 48" CLD 23 MLTPL
230LYYSSS8TAX 2" - 48" CLD 23 MLTPL
230W YY SSP8TAX 2" - 48" CLD 23 MLTPL
230WYYBBB8TAX 2" - 48" CLD 23 MLTPL
230WYYJJJ8TAX 2" - 48" CLD 23 MLTPL
230WYYKKK8TAX 2" - 48" CLD 23 MLTPL
230WYYSSS8TAX 2" - 48" CLD 23 MLTPL

[1] Certified for equivalent metric sizes.
[2] YY - 02 through 48
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
ABB Ltd. 
Oldends Lane
Stonehouse, Glos 
GL10 3TA 
United Kingdom 
44 14 5382 6661


Facility : Warminster, PA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Water Meters[1] [G]
AquaMaster FEF[1] >= 250 mm CLD 23 MLTPL
AquaMaster FER[1] 40 mm - 600 mm CLD 23 MLTPL
AquaMaster FEW[2] 40 mm - 2400 mm CLD 23 MLTPL
FEW XYZ.F[2] 40 mm - 2400 mm CLD 23 MLTPL
FEW XYZ.R[1] 40 mm - 600 mm CLD 23 MLTPL
ProcessMaster FEW XYZ[2] 40 mm - 2400 mm CLD 23 MLTPL
WaterMaster FEF[1] >= 250 mm CLD 23 MLTPL
WaterMaster FER[1] 40 mm - 600 mm CLD 23 MLTPL
WaterMaster FEW[2] 40 mm - 2400 mm CLD 23 MLTPL

[1] For all meters:
    X - Type of electronics
        4 - AquaMaster
        5 - WaterMaster
    Y - Tier of Electronics
        1 - Standard Electronics
        3 - Advanced Electronics
        5 - Premium Electronics
    Z - Type of mounting
        1 - Integral with transmitter
        2 - Remote with transmitter (Sensor + Transmitter)
        8 - Sensor only
    Type of bore and liner
    F - FEF/Full bore/Rubber liner
    R - FER/Reduced bore/Rubber liner
    
[1] For all meters:
    X - Type of electronics
        4 - AquaMaster
        5 - WaterMaster
    Y - Tier of Electronics
        1 - Standard Electronics
        3 - Advanced Electronics
        5 - Premium Electronics
    Z - Type of mounting
        1 - Integral with transmitter
        2 - Remote with transmitter (Sensor + Transmitter)
        8 - Sensor only
    Type of bore and liner
    F - FEF/Full bore/Rubber liner
    R - FER/Reduced bore/Rubber liner
    
[2] For all meters:
    X - Type of electronics
        4 - AquaMaster
        5 - WaterMaster
        6 - ProcessMaster
    Y - Tier of Electronics
        1 - Standard Electronics
        2 - Enhanced Electronic
        3 - Advanced Electronics
        5 - Premium Electronics
    Z - Type of mounting
        1 - Integral with transmitter
        2 - Remote with transmitter (Sensor + Transmitter)
        8 - Sensor only
    Type of bore and liner
    F - FEF/Full bore/Rubber liner
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


Facility : Shanghai, China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Water Meters[1] [G]
Aquamaster FEW 40 mm - 2400 mm CLD 23 MLTPL
FEW XYZ.F 40 mm - 2400 mm CLD 23 MLTPL
ProcessMaster FEW XYZ 40 mm - 2400 mm CLD 23 MLTPL
WaterMaster FEW 40 mm - 2400 mm CLD 23 MLTPL

[1] For all meters:
    X - Type of electronics	
        4 - AquaMaster	
        5 - WaterMaster
        6 - ProcessMaster		
    Y - Tier of Electronics	
        1 - Standard Electronics
        2 - Enhanced Electronic
        3 - Advanced Electronics	
        5 - Premium Electronics	
    Z - Type of mounting	
        1 - Integral with transmitter
        2 - Remote with transmitter (Sensor + Transmitter)
        8 - Sensor only	
    Type of bore and liner	
        F - FEF/Full bore/Rubber liner
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


Facility : Glos, United Kingdom

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Switches/Sensors
FEA121 - AquaProbe (with WaterMaster transmitter) 1" - 1.5" D. HOT MLTPL
FEA181 - AquaProbe (probe only) 1" - 1.5" D. HOT MLTPL
FEA221 - AquaProbe (with AquaMaster3 transmitter) 1" - 1.5" D. HOT MLTPL
FEA281 - AquaProbe (Flow sensor only) 1" - 1.5" D. HOT MLTPL
FEW xyz.A[1] 1" - 1.5" D. HOT MLTPL

[1] FEW XYZ A
    X - Type of electronics
        4 - AquaMaster
        5 - WaterMaster
    Y - Tier of Electronics
        1 - Standard Electronics
        3 - Advanced Electronics
        5 - Premium Electronics
    Z - Type of mounting
        1 - Integral with transmitter
        2 - Remote with transmitter (Sensor + Transmitter)
        8 - Sensor only

Water Meters [G]
AquaMaster FEF[4] >= 250 mm CLD 23 MLTPL
AquaMaster FER[4] 40 mm - 600 mm CLD 23 MLTPL
AquaMaster FEV[3] 40 mm - 200 mm CLD 23 MLTPL
AquaMaster FEW[2] 40 mm - 2400 mm CLD 23 MLTPL
FEW XYZ.F[2] 40 mm - 2400 mm CLD 23 MLTPL
FEW XYZ.R[4] 40 mm - 600 mm CLD 23 MLTPL
FEW XYZ.V[3] 40 mm - 200 mm CLD 23 MLTPL
ProcessMaster FEW XYZ[2] 40 mm - 2400 mm CLD 23 MLTPL
WaterMaster FEF[4] >= 250 mm CLD 23 MLTPL
WaterMaster FER[4] 40 mm - 600 mm CLD 23 MLTPL
WaterMaster FEV[3] 40 mm - 200 mm CLD 23 MLTPL
WaterMaster FEW[2] 40 mm - 2400 mm CLD 23 MLTPL

[2] For all meters:
    X - Type of electronics
        4 - AquaMaster
        5 - WaterMaster
        6 - ProcessMaster
    Y - Tier of Electronics
        1 - Standard Electronics
        2 - Enhanced Electronic
        3 - Advanced Electronics
        5 - Premium Electronics
    Z - Type of mounting
        1 - Integral with transmitter
        2 - Remote with transmitter (Sensor + Transmitter)
        8 - Sensor only
    Type of bore and liner:
    F - FEF/Full bore/Rubber liner
[3] For all meters:
        X - Type of electronics
            4 - AquaMaster
            5 - WaterMaster
        Y - Tier of Electronics
            1 - Standard Electronics
            3 - Advanced Electronics
            5 - Premium Electronics
        Z - Type of mounting
              1 - Integral with transmitter			
            2 - Remote with transmitter (Sensor + Transmitter)			
            8 – Sensor Only			
    
    Type of bore and liner:
    V – FEV/Optimized bore/PP liner
[4] For all meters:
        X - Type of electronics
            4 - AquaMaster
            5 - WaterMaster
        Y - Tier of Electronics
            1 - Standard Electronics
            3 - Advanced Electronics
            5 - Premium Electronics
        Z - Type of mounting
            1 - Integral with transmitter
            2 - Remote with transmitter (Sensor + Transmitter)
            8 – Sensor Only
    
        Type of bore and liner:
        F - FEF/Full bore/Rubber liner
        R - FER/Reduced bore/Rubber liner
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
ABB S.p.A. 
Via Luigi Vaccani, 4
22016 Ossuccio, Como 
Italy 
39 03 445 8111
Visit this company's website


Facility : Warminster, PA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Transmitters/Gauges[G]
266DSH Differential Pressure Transmitter 142 x 142 x 210 mm C. HOT MLTPL
266HSH Gauge Pressure Transmitter 142 x 91 x 215 mm C. HOT MLTPL
266NSH Absolute Pressure Transmitter 142 x 91 x 215 mm C. HOT MLTPL

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Abbott Rubber Company, Inc. 
1311 Meachum Rd.
Itasca, IL 60143 
United States 
800-852-1855 
847-952-1800
Visit this company's website


Facility : # 1 Canada

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

PVC Hose[1] [G]
T12 Series 1/8" - 2" CLD 23 FPVC

[1] This product has been evaluated for use in Piping (Section 4) applications: 
    			
    Diameter:	Length:			
    1/8" - 5/16"	No Restriction			
    3/8"    270"			
    7/16"   230"			
    1/2"    200"			
    9/16"   180"			
    5/8"    160" 			
    11/16"  145" 			
    3/4"    135" 			
    13/16" - 2" 	No Restriction
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

PVC Tubing[1] [G]
T10 Series 1/8" - 2" CLD 23 FPVC

[1] This product has been evaluated for use in Piping (Section 4) applications: 
    			
    Diameter:	Length:			
    1/8" - 5/16"	No Restriction			
    3/8"    270"			
    7/16"   230"			
    1/2"    200"			
    9/16"   180"			
    5/8"    160" 			
    11/16"  145" 			
    3/4"    135" 			
    13/16" - 2" 	No Restriction
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
ABN Pipe Systems S.L.U. 
Estrada Baños de Arteixo, 28
A Coruña 15008 
Spain 
34 650 720 82
Visit this company's website


Facility : Medina del Campo, Valladolid, Spain

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings[1] [G]
ABN//INSTAL FITTING RD 16 mm - 400 mm C. HOT PP

[1] Configurations (mm) include:
    Reducing Tee (Unequal Tee)
    20-16-20 D1TR020016020
    25-20-20 D1TR025020020
    25-20-25 D1TR025020025
    32-25-25 D1TR032020032
    32-20-32 D1TR032025025
    32-25-32 D1TR032025032
    40-20-40 D1TR040020040
    40-25-40 D1TR040025040
    40-32-40 D1TR040032040
    50-25-50 D1TR050025050
    50-32-50 D1TR050032050
    50-40-50 D1TR050040050
    63-25-63 D1TR063025063
    63-32-63 D1TR063032063
    63-40-63 D1TR063040063
    63-50-63 D1TR063050063
    75-32-75 D1TR075032075
    75-40-75 D1TR075040075
    75-50-75 D1TR075050075
    75-63-75 D1TR075063075
    90-50-90 D1TR090050090
    90-63-90 D1TR090063090
    90-75-90 D1TR090075090
    110-63-110 D1TR110063110
    110-75-110 D1TR110075110
    110-90-110 D1TR110090110
    45° Elbow
    16 D1C0160450000
    20 D1C0200450000
    25 D1C0250450000
    32 D1C0320450000
    40 D1C0400450000
    50 D1C0500450000
    63 D1C0630450000
    75 D1C0750450000
    90 D1C0900450000
    110 D1C1100450000
    125 D1C1250450000
    160 D1C1600450000
    90° Elbow
    16 D1C0160900000
    20 D1C0200900000
    25 D1C0250900000
    32 D1C0320900000
    40 D1C0400900000
    50 D1C0500900000
    63 D1C0630900000
    75 D1C0750900000
    90 D1C0900900000
    110 D1C1100900000
    125 D1C1250900000
    160 D1C1600900000
    Socket
    16 D1M0160000000
    20 D1M0200000000
    25 D1M0250000000
    32 D1M0320000000
    40 D1M0400000000
    50 D1M0500000000
    63 D1M0630000000
    75 D1M0750000000
    90 D1M0900000000
    110 D1M1100000000
    125 D1M1250000000
    160 D1M1600000000
    Equal Tee
    16 D1T0160000000
    20 D1T0200000000
    25 D1T0250000000
    32 D1T0320000000
    40 D1T0400000000
    50 D1T0500000000
    63 D1T0630000000
    75 D1T0750000000
    90 D1T0900000000
    110 D1T1100000000
    125 D1T1250000000
    160 D1T1600000000
    End Cap
    16 D1TA016000000
    20 D1TA020000000
    25 D1TA025000000
    32 D1TA032000000
    40 D1TA040000000
    50 D1TA050000000
    63 D1TA063000000
    75 D1TA075000000
    90 D1TA090000000
    110 D1TA110000000
    125 D1TA125000000
    160 D1TA160000000
    Flange Adaptor
    40 D1P0400000000
    50 D1P0500000000
    63 D1P0630000000
    75 D1P0750000000
    90 D1P0900000000
    110 D1P1100000000
    125 D1P1250000000
    160 D1P1600000000
    Reducer
    20-16 D1R0200160000
    25-20 D1R0250200000
    32-20 D1R0320200000
    32-25 D1R0320250000
    40-25 D1R0400250000
    40-32 D1R0400320000
    50-32 D1R0500320000
    50-40 D1R0500400000
    63-25 D1R0630250000
    63-32 D1R0630320000
    63-40 D1R0630400000
    63-50 D1R0630500000
    75-40 D1R0750400000
    75-50 D1R0750500000
    75-63 D1R0750630000
    90-63 D1R0900630000
    90-75 D1R0900750000
    110-63 D1R1100630000
    110-75 D1R1100750000
    110-90 D1R1100900000
    125-110 D1R1251100000
    160-110 D1R1601100000
    160-125 D1R1601250000
    Cross
    32 D1CRU03200000
    40 D1CRU04000000
    Reducing Cross
    50-32 D1CRUR0500320
    63-32 D1CRUR0630320
    63-40 D1CRUR0630400
    75-32 D1CRUR0750320
    75-40 D1CRUR0750400
    75-50 D1CRUR0750500
    90-50 D1CRUR0900500
    End Cap SDR11
    160 D5TAIS5160000
    200 D5TAIS5200000
    250 D5TAIS5250000
    315 D5TAIS5315000
    End Cap SDR17
    160 D5TAIS8160000
    200 D5TAIS8200000
    250 D5TAIS8250000
    315 D5TAIS8315000
    Flange Adaptor SDR11
    160 D5PIS51600000
    200 D5PIS52000000
    250 D5PIS52500000
    315 D5PIS53150000
    400 D5PIS54000000
    Flange Adaptor SDR17
    160 D5PIS81600000
    200 D5PIS82000000
    250 D5PIS82500000
    315 D5PIS83150000
    400 D5PIS84000000
    Cross over fittings
    20 D1S0200200000
    25 D1S0250200000
    32 D1S0320200000
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings, Non-Repeating[2] [G]
ABN//INSTAL FITTING RD 16 mm - 110 mm C. HOT PP

[2] Configurations (mm) include:
    Backplate 90° Elbow
    16-1/2" D2CP016012000
    20-1/2" D2CP020012000
    25-1/2" D2CP025012000
    Female Threaded Tee
    16-1/2" D2TRH01601200
    20-1/2" D2TRH02001200
    25-1/2" D2TRH02501200
    25-3/4" D2TRH02503400
    32-1/2" D2TRH03201200
    32-3/4" D2TRH03203400
    32-1" D2TRH03200100
    50-1/2" D2TRH05012000
    63-1/2" D2TRH06312000
    Female Hex. Threaded Adaptor
    32-1" D2ERHTE032001
    40-1 1/4" D2ERHTE040114
    50-1 1/2" D2ERHTE050112
    63-2" D2ERHTE063002
    75-2 1/2" D2ERHTE075212
    90-3" D2ERHTE090003
    110-4" D2ERHTE110004
    Male Hex. Threaded Adaptor
    32-1" D2ERMTE032001
    40-1 1/4" D2ERMTE040114
    50-1 1/2" D2ERMTE050112
    63-2" D2ERMTE063002
    75-2 1/2" D2ERMTE075212
    90-3" D2ERMTE090003
    110-4" D2ERMTE110004
    90° Elbow Female Threaded
    16-1/2" D2CRH01601290
    20-1/2" D2CRH02001290
    25-1/2" D2CRH02501290
    25-3/4" D2CRH02503490
    32-3/4" D2CRH03203490
    32-1" D2CRH03200190
    90° Elbow Male Threaded
    20-1/2" D2CRM02001290
    20-3/4" D2CRM02003490
    25-1/2" D2CRM02501290
    25-3/4" D2CRM02503490
    32-3/4" D2CRM03203490
    32-1" D2CRM03200190
    Adaptor Female Threaded
    16-1/2" D2ERH01601200
    20-1/2" D2ERH02001200
    25-1/2" D2ERH02501200
    25-3/4" D2ERH02503400
    32-3/4" D2ERH03203400
    Adaptor Male Threaded
    16-1/2" D2ERM01601200
    20-1/2" D2ERM02001200
    20-3/4" D2ERM02003400
    25-1/2" D2ERM02501200
    25-3/4" D2ERM02503400
    32-3/4" D2ERM03203400
    Adaptor Union Female Threaded
    20-1/2" D2TURH0200120
    25-3/4" D2TURH0250340
    32-1" D2TURH0320001
    40-1 1/4" D2TURH0401140
    50-1 1/2" D2TURH0501120
    63-2" D2TURH0630200
    75-2 1/2" D2TURH0750212
    90-3" D2TURH0900003
    110-4" D2TURH1100004
    Adaptor Union Male Threaded
    20-1/2" D2TURM0200120
    25-3/4" D2TURM0250340
    32-1" D2TURM0320001
    40-1 1/4" D2TURM0401140
    50-1 1/2" D2TURM0501120
    63-2" D2TURM0630002
    75-2 1/2" D2TURM0750212
    90-3" D2TURM0900003
    110-4" D2TURM1100004
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe[G]
ABN//INSTAL CT FASER RD 20 mm - 500 mm C. HOT PP

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Service Saddles[3] [G]
ABN//INSTAL FITTING RD 20 x 50-63 x 315 mm C. HOT PP

[3] Welding Saddles - Male (saddle connection x pipe size)
    20-50 D5IDM02005000
    20-63 D5IDM02006300
    20-75 D5IDM02007500
    20-90 D5IDM02009000
    20-110 D5IDM02011000
    20-125 D5IDM02012500
    20-160 D5IDM02016000
    20-200 D5IDM02020000
    25-50 D5IDM02505000
    25-63 D5IDM02506300
    25-75 D5IDM02507500
    25-90 D5IDM02509000
    25-110 D5IDM02511000
    25-125 D5IDM02512500
    25-160 D5IDM02516000
    25-200 D5IDM02520000
    32-50 D5IDM03205000
    32-63 D5IDM03206300
    32-75 D5IDM03207500
    32-90 D5IDM03209000
    32-110 D5IDM03211000
    32-125 D5IDM03212500
    32-160 D5IDM03216000
    32-200 D5IDM03220000
    40-90 D5IDM04009000
    40-110 D5IDM04011000
    40-125 D5IDM04012500
    40-160 D5IDM04016000
    40-200 D5IDM04020000
    40-250 D5IDM04025000
    40-315 D5IDM04031500
    50-90 D5IDM05009000
    50-110 D5IDM05011000
    50-125 D5IDM05012500
    50-160 D5IDM05016000
    50-200 D5IDM05020000
    50-250 D5IDM05025000
    50-135 D5IDM05031500
    63-125 D5IDM06312500
    63-160 D5IDM06316000
    63-200 D5IDM06320000
    63-250 D5IDM06325000
    63-315 D5IDM06331500
    
    Welding Saddles - Female (saddle connection x pipe size)
    20-50 D5IDH02005000
    20-63 D5IDH02006300
    20-75 D5IDH02007500
    20-90 D5IDH02009000
    20-110 D5IDH02011000
    20-125 D5IDH02012500
    20-160 D5IDH02016000
    20-200 D5IDH02020000
    25-50 D5IDH02505000
    25-63 D5IDH02506300
    25-75 D5IDH02507500
    25-90 D5IDH02509000
    25-110 D5IDH02511000
    25-125 D5IDH02512500
    25-160 D5IDH02516000
    25-200 D5IDH02520000
    32-90 D5IDH03209000
    32-110 D5IDH03211000
    32-125 D5IDH03212500
    32-160 D5IDH03216000
    32-200 D5IDH03220000
    40-90 D5IDH04009000
    40-110 D5IDH04011000
    40-125 D5IDH04012500
    40-160 D5IDH04016000
    40-200 D5IDH04020000
    40-250 D5IDH04025000
    40-315 D5IDH04031500
    50-110 D5IDH05011000
    50-125 D5IDH05012500
    50-160 D5IDH05016000
    50-200 D5IDH05020000
    50-250 D5IDH05025000
    50-315 D5IDH05031500
    50-160 D5IDM05016000
    50-200 D5IDM05020000
    50-250 D5IDM05025000
    50-315 D5IDM05031500
    63-110 D5IDM06311000
    63-125 D5IDM06312500
    63-160 D5IDM06316000
    63-200 D5IDM06320000
    63-250 D5IDM06325000
    63-315 D5IDM06331500
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Accella Polyurethane Systems, LLC DBA Carlisle Polyurethane Systems, 
Carlisle Roof Foam and Coatings
2500 Adie Road 
Maryland Heights, MO 63043 
United States 
770-528-9556
Visit this company's website


Facility : Rancho Cucamonga, CA

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Grouts[1]
Substratum [2] CLD 23 PUR
Substratum 2F [2] CLD 23 PUR
Substratum 2R [2] CLD 23 PUR
Substratum 3F [2] CLD 23 PUR
Substratum 3R [2] CLD 23 PUR
Substratum 4F [2] CLD 23 PUR
Substratum 4R [2] CLD 23 PUR
Substratum 4S [2] CLD 23 PUR
Substratum 5R [2] CLD 23 PUR
Substratum 6R [2] CLD 23 PUR
Substratum Geopolymer [2] CLD 23 PUR

[1] Certified for product with the following densities and reaction speeds:
    2 pounds per cubic foot (regular speed)
    2 pounds per cubic foot (fast speed)
    3 pounds per cubic foot (regular speed)
    3 pounds per cubic foot (fast speed)
    4 pounds per cubic foot (slow speed)
    4 pounds per cubic foot (regular speed)
    4 pounds per cubic foot (fast speed)
    5 pounds per cubic foot (regular speed)
    6 pounds per cubic foot (regular speed)
    
    Mix ratio is 1:1 (A:B) by volume or 8.1:6.9 (A:B) by weight.
    Minimum cure time is 60 minutes at ambient temperatures.
[2] Certified for a maximum surface area to volume ratio of 0.375 square inches per liter.



Facility : Chattanooga, TN

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Grouts[1]
Substratum [2] CLD 23 PUR
Substratum 2F [2] CLD 23 PUR
Substratum 2R [2] CLD 23 PUR
Substratum 3F [2] CLD 23 PUR
Substratum 3R [2] CLD 23 PUR
Substratum 4F [2] CLD 23 PUR
Substratum 4R [2] CLD 23 PUR
Substratum 4S [2] CLD 23 PUR
Substratum 5R [2] CLD 23 PUR
Substratum 6R [2] CLD 23 PUR
Substratum Geopolymer [2] CLD 23 PUR

[1] Certified for product with the following densities and reaction speeds:
    2 pounds per cubic foot (regular speed)
    2 pounds per cubic foot (fast speed)
    3 pounds per cubic foot (regular speed)
    3 pounds per cubic foot (fast speed)
    4 pounds per cubic foot (slow speed)
    4 pounds per cubic foot (regular speed)
    4 pounds per cubic foot (fast speed)
    5 pounds per cubic foot (regular speed)
    6 pounds per cubic foot (regular speed)
    
    Mix ratio is 1:1 (A:B) by volume or 8.1:6.9 (A:B) by weight.
    Minimum cure time is 60 minutes at ambient temperatures.
[2] Certified for a maximum surface area to volume ratio of 0.375 square inches per liter.



 
Accent Control Systems 
2101 Potshop Lane
Norristown, PA 19403 
United States 
610-630-7640


Facility : Ningbo, China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Water Meters[G]
GLF-062/GLF-062-R 5/8" x 1/2" CLD 23 MLTPL
GLF-075/GLF-075-R 5/8" x 3/4" CLD 23 MLTPL
GLF-100/GLF-100-R 3/4" x 1" CLD 23 MLTPL
GLF-100F/GLF-100F-R 1" CLD 23 MLTPL
GLF-150/GLF-150-R 1 1/2" CLD 23 MLTPL
GLF-200(F)/GLF-200-R(F) 2" CLD 23 MLTPL
GLF-200/GLF-200-R 2" CLD 23 MLTPL

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
ACCESS TRUCK PARTS 
2757 E Chambers Street
Phoenix, AZ 85040 
United States 
602-437-6948


Facility : Anhui, China

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Pumps [G]
101-XANN-YYG[1] 50x32 - 350x300 mm D. HOT MLTPL

[1] The variables in the trade name denote the following:
    "NN" refers to outlet size, ranging from 32 mm to 300 mm.
    "YY" refers to impeller diameter, ranging from 13 cm - 50 cm.
    "G" is an optional designation indicating High Speed.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Access-Able Technologies, Inc. 
1275 Bennett Drive #115
Longwood, FL 32750 
United States 
800-572-4894 
407-834-2999


Facility : # 1 USA

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Patching Materials [G]
Pow-R Stick Steel Hard Epoxy Putty (Copper Color) [1] [2] C. HOT EPOXY
Pow-R Stick Steel Hard Epoxy Putty (Grey Color) [1] [2] C. HOT EPOXY
Pow-R Stick Steel Hard Epoxy Putty (White Color) [1] [2] C. HOT EPOXY
STIC-O-STEEL POW-R Putty [1] [2] C. HOT EPOXY

[1] Certified for a maximum surface area to volume ratio of 0.3 sq. in./L in pipe or 1% of a
    20,000 gallon tank.
[2] To obtain the proper mix, use at least a 3/4" length, but no more than 1/3 of a full
    stick, of product which has been cut with a knife. Product must be mixed for 60-90
    seconds.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Accor Technology Inc. 
3310 South East 5th Street
East Wenatchee, WA 98802 
United States 
800-447-5848 
509-662-0608


Facility : East Wenatchee, WA

Mechanical Plumbing Devices

Trade Designation      

Connector Hoses

Riser Assemblies[1]
R-5CP(1)-7(2)      
R-5CS(1)-7(2)      
R-5LP(1)-5(2)      
R-5LS(1)-5(2)      
R-CP(1)-7(2)      
R-CS(1)-7(2)      
R-LP(1)-3(2)      
R-LP(1)-5(2)      
R-LS(1)-3(2)      
R-LS(1)-5(2)      
R2-IP(1)-2(2)      
R3-LP(1)-3(2)      
RCP45T12-7(2)      

[1] (1) Hose length
    (2) Packaging options (M, F, E, EL, CF, CM, PF, FM, XM, XF, XE, XL, XC, or R)

Supply Stops

Coupling w/ attached riser[1] [G]
PR30-LP(1)-3(2)      
PR30-SP(1)-3(2)      
PR50-CP(1)-7(2)      
PR50-CS(1)-7(2)      
PR50-LP(1)-3(2)      
PR50-LP(1)-5(2)      
PR50-LS(1)-3(2)      
PR50-LS(1)-5(2)      
PR50-P(1)-RK(2)      
PR50-S(1)-RK(2)      
PR50-SP(1)-5(2)      

[1] (1) Hose length
    (2) Packaging options (M, F, E, EL, CF, CM, PF, FM, XM, XF, XE, XL, XC, or R)
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Valve or Coupling[1] [G]
PC5-3(2)      
PC5S-3(2)      
PE5-3(2)      
PE5S-3(2)      
PO5-2(2)      
PO5-3(2)      
PO5-75(2)      
PO5-CAP(2)      
PR-30(2)      
PR-50(2)      
TH5-3(2)      

[1] (1) Hose length
    (2) Packaging options (M, F, E, EL, CF, CM, PF, FM, XM, XF, XE, XL, XC, or R)
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Valve w/ attached riser[1] [G]
PC5-CP(1)-7(2)      
PC5-CS(1)-7(2)      
PC5-LP(1)-5(2)      
PC5-LS(1)-5(2)      
PE5-CP(1)-7(2)      
PE5-CS(1)-7(2)      
PE5-LP(1)-5(2)      
PE5-LS(1)-5(2)      
PO5-CP(1)-7(2)      
PO5-CS(1)-7(2)      
PO5-IP(1)-2(2)      
PO5-LP(1)-3(2)      
PO5-LP(1)-5(2)      
PO5-LP4T15-5(2)      
PO5-LS(1)-3(2)      
PO5-LS(1)-5(2)      
PO5-LS4T15-5(2)      
PO5-P(1)-RK(2)      
PO5-P-PR30(2)      
PO5-S(1)-RK(2)      
PO5-S-PR30(2)      
PO5P10T10RK(2)      

[1] (1) Hose length
    (2) Packaging options (M, F, E, EL, CF, CM, PF, FM, XM, XF, XE, XL, XC, or R)
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
ACCOR Technology, Inc. 
3310 5th Street Southeast
East Wenatchee, WA 98802 
United States 
509-888-2233
Visit this company's website


Facility : East Wenatchee, WA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Miscellaneous Process Devices/Components[G]
PushOn 113A Accor Arrester 1/2" C. HOT MLTPL
PushOn 109A Accor Arrester 1/2" C. HOT MLTPL

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings [G]
PF50C XE[1] 1/2" C. HOT MLTPL
PF50E XE[1] 1/2" C. HOT MLTPL
PF50MT XE[2] 1/2" C. HOT MLTPL
PF50T XE[1] 1/2" C. HOT MLTPL
PF75C XE[1] 3/4" C. HOT MLTPL
PF75E XE[1] 3/4" C. HOT MLTPL
PF75T XE[1] 3/4" C. HOT MLTPL

[1] Configuration code breakdown: 
    P  – PushOn 
    F  – Fitting 
    50 - 1/2" 
    75 - 3/4" 
    M  – Manifold 
    T  – Tee 
    C  – Coupling 
    E  – Elbow 
    X  – Compatible with PEX pipe (as well as copper and CPVC) 
    E  – Bulk packaged (each)
[2] PF50MT XE – 1/2" PushOnManifold Tee Code: 
    P  – PushOn 
    F  – Fitting 
    50 – 1/2 inch 
    M  – Manifold 
    T  – Tee 
    X  – Compatible with PEX pipe (as well as copper and CPVC). 
    E  – Bulk packaged (each)
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
ACCUCAST Ltd. 
415 South 21ST Street
Waco, TX 76706 
United States 
254-756-3200
Visit this company's website


Facility : Shanxi, China

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings[1] [G]
Ductile Iron C110 Flanged Pipe Fittings 3" - 12" CLD 23 ASPH
Ductile Iron C153 Mechanical Joint Pipe Fittings 3" - 12" CLD 23 ASPH

[1] Certification does not include gaskets.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Accuflex Industrial Hose Ltd. 
760 Imperial Road North
Guelph, ON N1K 1Z3 
Canada 
519-836-5460
Visit this company's website


Facility : Guelph, Ontario, Canada

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Tubing/Hose[1] [G]
Bev-Flex® 172 1/4" - 1" CLD 23 PE
Bev-Seal® 176 1/4" - 1" CLD 23 PE
Bev-Seal® 228 1/4" - 1" CLD 23 PE
Bev-Seal® Ultra 175 3/16" - 1" CLD 23 PET
Bev-Seal® Ultra 235 3/16" - 1" CLD 23 PET
Bevlex® 170[2] 1/4" - 1" CLD 23 PE
Bevlex® 174 1/4" - 1" CLD 23 PE
Bevlex® 222 1/4" - 1" CLD 23 PE
Bevlex® 222YYY[3] 1/4" - 1" CLD 23 PE
Bevlex® 224 1/4" - 1" CLD 23 PE
Bevlex® Plus 180 3/16" - 1" CLD 23 PET
Kuri Tec® A3236 1/4" - 1" CLD 23 PE
Kuri Tec® A3246 1/4" - 1" CLD 23 PE

[1] Trade name may feature prefix "E" to denote product sold in Europe.
[2] Suffix denotes color for the outermost layer. Color codes are:
    BK - Black
    BL - Blue
    W  - White
    G  - Light Grey
    GR - Green
    DG - Dark Grey
    R  - Red
[3] YYY denotes color for the outermost layer. Color codes are:
    BLK  - Black
    BLU  - Blue
    DGRY - Dark Gray
    GRN  - Green
    LGRY - Light Gray 
    RED  - Red
    WHT  - White
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Ace Duraflo Systems, LLC 
3122 West Alpine Street
Santa Ana, CA 92704 
United States 
714-256-0220
Visit this company's website


Facility : # 1 USA

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Pipe - Immediate Return to Service
ePIPE FRS[1] [2] >= 1/2" C. HOT EPOXY

[1] Colors: Red
    Number of Coats: 1
    Maximum Field Use Dry Thickness (in mils): 4-500
    Final Cure Time/Temperature: 15 minutes in water at a service temperature of 23C and
    greater.
    Special Comments: Mix ratio of A:B is 2:1 by volume. Product shall be preconditioned to
    at least 95F prior to mixing. Induction time is at least 10 minutes. Cure with air at a
    minimum of 95F for at least 2 hours. Following the air cure, product cure shall continue
    in water at a service temperature of 23C and greater for 15 minutes with a flow rate of
    1 to 5 liters per minute prior to being placed into service.
[2] Certified for Immediate Return to Service. 



 
Ace Hardware Corporation 
2200 Kensington Ct
Oakbrook, IL 60523 
United States 
630-990-8686
Visit this company's website


Facility : Omaha, NE

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Sealants
ACE PIPE THREAD COMPOUND TFE PASTE >= 1/2" C. HOT SLT
Ace Pipe Thread Compound >= 1/2" C. HOT SLT



 
Ace Roto-Mold 
Division of Den Hartog Industries Inc.
4010 Hospers Drive South 
P.O. Box 425 
Hospers, IA 51238-0425 
United States 
800-342-3408 
712-752-8432
Visit this company's website


Facility : Hospers, IA

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Tanks[1]
ACTXXXX-LP Cistern Tank [2] CLD 23 MLTPL
ARM-VVVVV [2] CLD 23 MLTPL
AST-XXXX-1W Cistern Tank [2] CLD 23 MLTPL
CBXXXX-YY Batch Tank - Cone Bottom [2] CLD 23 MLTPL
CBXXXX-YY Cone Bottom - Industrial Top [2] CLD 23 MLTPL
CBXXXX-YYY Cone Bottom Tank [2] CLD 23 MLTPL
CBXXXXX-YYY Cone Bottom Tank [2] CLD 23 MLTPL
DWXXXX-120 Double Wall Vertical Tank [2] CLD 23 MLTPL
DWXXXX-YY Double Wall Vertical Tank [2] CLD 23 MLTPL
EOXXXX-YY Elliptical Tank - Offset Lid [2] CLD 23 MLTPL
FMXXXX-YYS Leg Tank [2] CLD 23 MLTPL
FMXXXX-YYY Leg Tank [2] CLD 23 MLTPL
FS01600 Sectional Tank 1600 gal. CLD 23 MLTPL
FS01610 Flat Bottom Leg Tank 1610 gal. CLD 23 MLTPL
FSXXXXX-YY Leg Tank [2] CLD 23 MLTPL
FSXXXXX-YYW Leg Tank [2] CLD 23 MLTPL
GVXXXX-86 Gusset Top Tank [2] CLD 23 MLTPL
GVXXXXX-142 Vertical Polyethylene Storage Tank [2] CLD 23 MLTPL
HEDXXXX-YY Elliptical Tank [2] CLD 23 MLTPL
HEXXXX-YY Elliptical Tank [2] CLD 23 MLTPL
HZXXXXX-YY Horizontal Tank [2] CLD 23 MLTPL
IBFDXX-SET Inductor Tank [2] CLD 23 MLTPL
INFD085 Full Drain Inductor 85 gal. CLD 23 MLTPL
INFDXXX-YY Inductor Tank [2] CLD 23 MLTPL
INXXXX-YYYY Inductor Tank [2] CLD 23 MLTPL
LPXXXX-HT Holding Tank [2] CLD 23 MLTPL
LPXXXX-RT Low Profile Tank [2] CLD 23 MLTPL
LPXXXX-RT Rectangle Tank [2] CLD 23 MLTPL
OCXXXX-YY Batch Tank - Cone Bottom - Open Top [2] CLD 23 MLTPL
OCXXXX-YY Cone Bottom Tank - Open Top [2] CLD 23 MLTPL
OP0210-40 Open Top 210 gal. CLD 23 MLTPL
OPXXXX-YY Batch Tank- Vertical - Open Top [2] CLD 23 MLTPL
PCOXXX-YYZ PCO tank [2] CLD 23 MLTPL
PUXXXX-YY Pickup Tank [2] CLD 23 MLTPL
SBXXXXX Spot Spray [2] CLD 23 MLTPL
SP-XXXX-QQ Applicator Tank [2] CLD 23 MLTPL
SP-XXXXQQ Applicator Tank [2] CLD 23 MLTPL
SP002.8-RT Rectangle Tank – Flat Bottom 2.8 gal. CLD 23 MLTPL
SPBMXX-SQ# Specialty Tank [2] CLD 23 MLTPL
SPBMXXXX-RT Specialty Tank [2] CLD 23 MLTPL
SPXXXX-RT Total Drain Rectangular Tank [2] CLD 23 MLTPL
SPXXXX-SQ# Specialty Tank [2] CLD 23 MLTPL
SPXXXX-UU Rectangle Tank [2] CLD 23 MLTPL
SPXXXX-UU Specialty Tank [2] CLD 23 MLTPL
SPXXXX-VM Applicator Tank [2] CLD 23 MLTPL
SPXXXXX-UU Utility Tank [2] CLD 23 MLTPL
SSPUXXXX-70 Pickup Tank [2] CLD 23 MLTPL
VTXXXX-YY Batch Tank- Vertical [2] CLD 23 MLTPL
VTXXXXX-YYY [2] CLD 23 MLTPL
VTXXXXX-YYYY Vertical Polyethylene Storage Tank [2] CLD 23 MLTPL
WOXXXX-VT Water Only Tank [2] CLD 23 MLTPL

[1] Certified for the following tank/component combinations:
    3/4" fittings/fitting gaskets shall only be used with tanks greater than or equal to 2.8
    gallons.
    1" fittings/fitting gaskets shall only be used with tanks greater than or equal to 3
    gallons.
    1-1/4" and 1-1/2" fittings/fitting gaskets shall only be used with tanks greater than or
    equal to 4 gallons.
    2" fittings/fitting gaskets shall only be used with tanks greater than or equal to 5
    gallons.
    3" fittings/fitting gaskets shall only be used with tanks greater than or equal to 95
    gallons.
    Siphon tubes shall only be used with tanks greater than or equal to 5 gallons.
[2] The trade names include product information represented by alphanumeric code, denoted as
    follows:										
    XXXX, XXXXX, XXXXXX: Tank volume in gallons (2.8 gallons and greater)										
    YY, YYY, YYYY diameter/width of tank in inches										
    QQ: Customer code										
    Z: Can be S (sump) or W (no sump)										
    UU: Can be RT (Rectangular Tank), SQ (Square Tank), 2P (2in lid), 5N (5 in lid), or any
    other two alphabetical code (customer code)										
    VVVVV: Part number										
    #: Lid size in inches.



 
ACL SRL 
Via G.Falcone, 6
20873 Cavenago Di Brianza 
Italy 
39 02 9501335


Facility : Cavenago Di Brianza, Italy

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Solenoid Valves[G]
D117CNM12/61/DC coil 3/8" CLD 23 MLTPL
E207CNM12/61/AC-DC coil 3/8" CLD 23 MLTPL
D207CNM12/61/DC coil 3/8" CLD 23 MLTPL
D107CNM12/61/DC coil 3/8" CLD 23 MLTPL
E107CM12/61/AC-DC coil 3/8" CLD 23 MLTPL
E107CNM12/61/AC-DC coil 3/8" CLD 23 MLTPL
D117CM12/61/DC coil 3/8" CLD 23 MLTPL
D107CM12/61/DC coil 3/8" CLD 23 MLTPL
E207CM12/61/AC-DC coil 3/8" CLD 23 MLTPL
D207CM12/61/DC coil 3/8" CLD 23 MLTPL
E107DNM12/61/AC-DC coil 1/2" CLD 23 MLTPL
E107DM12/61/AC-DC coil 1/2" CLD 23 MLTPL
D207DNM12/61/DC coil 1/2" CLD 23 MLTPL
D117DNM12/61/DC coil 1/2" CLD 23 MLTPL
D107DNM12/61/DC coil 1/2" CLD 23 MLTPL
E207DNM12/61/AC-DC coil 1/2" CLD 23 MLTPL
D107DM12/61/DC coil 1/2" CLD 23 MLTPL
D117DM12/61/DC coil 1/2" CLD 23 MLTPL
E207DM12/61/AC-DC coil 1/2" CLD 23 MLTPL
D207DM12/61/DC coil 1/2" CLD 23 MLTPL
D107ENM18/61/DC coil 3/4" CLD 23 MLTPL
D117ENM18/61/DC coil 3/4" CLD 23 MLTPL
D207ENM18/61/DC coil 3/4" CLD 23 MLTPL
E107EM18/61/AC-DC coil 3/4" CLD 23 MLTPL
E107ENM18/61/AC-DC coil 3/4" CLD 23 MLTPL
E207ENM18/61/AC-DC coil 3/4" CLD 23 MLTPL
D107EM18/61/DC coil 3/4" CLD 23 MLTPL
D117EM18/61/DC coil 3/4" CLD 23 MLTPL
E207EM18/61/AC-DC coil 3/4" CLD 23 MLTPL
D207EM18/61/DC coil 3/4" CLD 23 MLTPL
D207FNM25/61/DC coil 1" CLD 23 MLTPL
E207FNM25/61/AC-DC coil 1" CLD 23 MLTPL
E107FNM25/61/AC-DC coil 1" CLD 23 MLTPL
E107FM25/61/AC-DC coil 1" CLD 23 MLTPL
D107FNM25/61/DC coil 1" CLD 23 MLTPL
D117FNM25/61/DC coil 1" CLD 23 MLTPL
D107FM25/61/DC coil 1" CLD 23 MLTPL
D117FM25/61/DC coil 1" CLD 23 MLTPL
E207FM25/61/AC-DC coil 1" CLD 23 MLTPL
D207FM25/61/DC coil 1" CLD 23 MLTPL
D117GNM30/61/DC coil 1 1/4" CLD 23 MLTPL
D107GNM30/61/DC coil 1 1/4" CLD 23 MLTPL
E107GNM30/61/AC-DC coil 1 1/4" CLD 23 MLTPL
E107GM30/61/AC-DC coil 1 1/4" CLD 23 MLTPL
D207GNM30/61/DC coil 1 1/4" CLD 23 MLTPL
E207GNM30/61/AC-DC coil 1 1/4" CLD 23 MLTPL
D107GM30/61/DC coil 1 1/4" CLD 23 MLTPL
E107GM37/61/AC-DC coil 1 1/4" CLD 23 MLTPL
D107GM37/61/DC coil 1 1/4" CLD 23 MLTPL
D117GM30/61/DC coil 1 1/4" CLD 23 MLTPL
D117GM37/61/DC coil 1 1/4" CLD 23 MLTPL
E207GM30/61/AC-DC coil 1 1/4" CLD 23 MLTPL
D207GM30/61/DC coil 1 1/4" CLD 23 MLTPL
E207GM37/61/AC-DC coil 1 1/4" CLD 23 MLTPL
D107GNM37/61/DC coil 1 1/4" CLD 23 MLTPL
D117GNM37/61/DC coil 1 1/4" CLD 23 MLTPL
D207GM37/61/DC coil 1 1/4" CLD 23 MLTPL
D207GNM37/61/DC coil 1 1/4" CLD 23 MLTPL
E107GNM37/61/AC-DC coil 1 1/4" CLD 23 MLTPL
E207GNM37/61/AC-DC coil 1 1/4" CLD 23 MLTPL
E107HM37/61/AC-DC coil 1 1/2" CLD 23 MLTPL
D107HM37/61/DC coil 1 1/2" CLD 23 MLTPL
D117HM37/61/DC coil 1 1/2" CLD 23 MLTPL
E207HM37/61/AC-DC coil 1 1/2" CLD 23 MLTPL
D117HNM37/61/DC coil 1 1/2" CLD 23 MLTPL
E207HNM37/61/AC-DC coil 1 1/2" CLD 23 MLTPL
D207HM37/61/DC coil 1 1/2" CLD 23 MLTPL
E107HNM37/61/AC-DC coil 1 1/2" CLD 23 MLTPL
D107HNM37/61/DC coil 1 1/2" CLD 23 MLTPL
D207HNM37/61/DC coil 1 1/2" CLD 23 MLTPL
E107IM50/61/AC-DC coil 2" CLD 23 MLTPL
D107IM50/61/DC coil 2" CLD 23 MLTPL
D117IM50/61/DC coil 2" CLD 23 MLTPL
E207IM50/61/AC-DC coil 2" CLD 23 MLTPL
D107INM50/61/DC coil 2" CLD 23 MLTPL
E207INM50/61/AC-DC coil 2" CLD 23 MLTPL
D117INM50/61/DC coil 2" CLD 23 MLTPL
E107INM50/61/AC-DC coil 2" CLD 23 MLTPL
D207INM50/61/DC coil 2" CLD 23 MLTPL
D207IM50/61/DC coil 2" CLD 23 MLTPL
E107MNM75/61/AC-DC coil 2 1/2" CLD 23 MLTPL
D107MM75/61/DC coil 2 1/2" CLD 23 MLTPL
D107MNM75/61/DC coil 2 1/2" CLD 23 MLTPL
D207MNM75/61/DC coil 2 1/2" CLD 23 MLTPL
E207MNM75/61/AC-DC coil 2 1/2" CLD 23 MLTPL
D117MNM75/61/DC coil 2 1/2" CLD 23 MLTPL
E107MM75/61/AC-DC coil 3" CLD 23 MLTPL
E107RM75/61/AC-DC coil 3" CLD 23 MLTPL
D107RM75/61/DC coil 3" CLD 23 MLTPL
D117MM75/61/DC coil 3" CLD 23 MLTPL
D117RM75/61/DC coil 3" CLD 23 MLTPL
E207MM75/61/AC-DC coil 3" CLD 23 MLTPL
D207MM75/61/DC coil 3" CLD 23 MLTPL
E207RM75/61/AC-DC coil 3" CLD 23 MLTPL
E207RNM75/61/AC-DC coil 3" CLD 23 MLTPL
D207RNM75/61/DC coil 3" CLD 23 MLTPL
D207RM75/61/DC coil 3" CLD 23 MLTPL
E107RNM75/61/AC-DC coil 3" CLD 23 MLTPL
D117RNM75/61/DC coil 3" CLD 23 MLTPL
D107RNM75/61/DC coil 3" CLD 23 MLTPL

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Acme Chemicals Malaysia Sdn. Bhd. 
Lot 606, Persiaran Raja Lumu
Pandamaran Industrial Estate, Klang 
42000 Selangor 
Malaysia 
60 3 3175 6088
Visit this company's website


Facility : Selangor, Malaysia

Process Media

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Adsorption Media
ACM OPC 200 XZ[1] [2] CLD 23 ZEO
ACM OPC 200 XZB[1] [2] CLD 23 ZEO
ACM OPC 200Z[1] [2] CLD 23 ZEO

[1] Certification is based on a bed depth up to 65 cm with a minimum flow rate of 3.82 cubic
    meter per hour per sq. meter.
[2] Certified for mesh size 0.8 x 1.5 mm.

NOTE: Certified for water treatment plant applications.
      This product has not been evaluated for point of use applications.


 
ACPP Custom Plumbing Parts, ULC 
10037-96 Avenue
Westlock, AB T7P-2P9 
Canada 
780-349-6511


Facility : Westlock, Alberta, Canada

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Manifolds
Copper Manifolds [1] C. HOT CU

[1] The following part numbers, configurations and sizes are Certified.  All manifolds are
    72" long (unless otherwise noted) and may be cut to the desired length.
    
    Copper Manifolds with Copper Ports:
    
    Pipe run 1", 1 1/4", 1 1/2" or 2" with 24 1/2", 3/4", or 1" copper outlets on 3" CTRS.
    
    CC1005024 1 X 1/2 CU
    CC1255024 1 1/4 X 1/2 CU
    CC1251024 1 1/4 X 1 CU
    CC1505024 1 1/2 X 1/2 CU
    CC1501024 1 1/2 X 1 CU
    CC2005024 2 X 1/2 CU
    CC1007524 1 X 3/4 CU
    CC1257524 1 1/4 X 3/4 CU
    CC1507524 1 1/2 X 3/4 CU
    CC2007524 2 X 3/4 CU
    CC2001024 2 X 1 CU
    
    Pipe run 1", 1 1/4", 1 1/2" or 2" with 18 1/2", 3/4", or 1" copper outlets on 4" CTRS
    
    CC1005018 1 X 1/2 CU
    CC1255018 1 1/4 X 1/2 CU
    CC1505018 1 1/2 X 1/2 CU
    CC2005018 2 X 1/2 CU
    CC1007518 1 X 3/4 CU
    CC1257518 1 1/4 X 3/4 CU
    CC1507518 1 1/2 X 3/4 CU
    CC2007518 2 X 3/4 CU
    CC1251018 1 1/4 X 1 CU
    CC1501018 1 1/2 X 1 CU
    CC2001018 2 X 1 CU
    
    Pipe run 1", 1 1/4", 1 1/2" or 2" with 12 1/2", 3/4", or 1" copper outlets on 6" CTRS.
    
    CC1005012ER 1 X 1/2 CU
    CC1255012ER 1 1/4 X 1/2 CU
    CC1505012ER 1 1/2 X 1/2 CU
    CC2005012ER 2 X 1/2 CU
    CC1007512ER 1 X 3/4 CU
    CC1257512ER 1 1/4 X 3/4 CU
    CC1507512ER 1 1/2 X 3/4 CU
    CC2007512ER 2 X 3/4 CU
    CC1251012ER 1 1/4 X 1 CU
    CC1501012ER 1 1/2 X 1 CU
    CC2001012ER 2 X 1 CU
    
    Pipe run 62" long, 1" with 30 1/2" copper outlets on 2" CTRS.
    
    CC1005030 1 X 1/2 CU
    
    Compact Headers - Pipe run 1" with 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, or 12 1/2" copper
    outlets on 1 1/2" CTRS.
    
    CC1005002 1 X 1/2 CU
    CC1005003 1 X 1/2 CU
    CC1005004 1 X 1/2 CU
    CC1005005 1 X 1/2 CU
    CC1005006 1 X 1/2 CU
    CC1005007 1 X 1/2 CU
    CC1005008 1 X 1/2 CU
    CC1005009 1 X 1/2 CU
    CC1005010 1 X 1/2 CU
    CC1005011 1 X 1/2 CU
    CC1005012 1 X 1/2 CU
    
    Speedy Copper Headers - closed one end and reduced 3/4" female sweat the other end.
    
    SC1005002RC 1 X 1/2 CU
    SC1005003RC 1 X 1/2 CU
    SC1005004RC 1 X 1/2 CU
    SC1005005RC 1 X 1/2 CU
    SC1005006RC 1 X 1/2 CU
    SC1005007RC 1 X 1/2 CU
    SC1005008RC 1 X 1/2 CU
    SC1005009RC 1 X 1/2 CU
    SC1005010RC 1 X 1/2 CU
    SC1005011RC 1 X 1/2 CU
    SC1005012RC 1 X 1/2 CU
    
    Speedy Copper Headers - closed one end and 1" plain the other end.
    
    SC1005002PL 1 X 1/2 CU
    SC1005003PL 1 X 1/2 CU
    SC1005004PL 1 X 1/2 CU
    SC1005005PL 1 X 1/2 CU
    SC1005006PL 1 X 1/2 CU
    SC1005007PL 1 X 1/2 CU
    SC1005008PL 1 X 1/2 CU
    SC1005009PL 1 X 1/2 CU
    SC1005010PL 1 X 1/2 CU
    SC1005011PL 1 X 1/2 CU
    SC1005012PL 1 X 1/2 CU
    
    Copper Manifolds with PEX Valves:
    
    Type L Copper Manifold with a Lead Free PEX Valve
    1", 1 1/4", 1 1/2", and 2" Copper Headers with 1/2" Lead Free PEX Valves on 3" Center
    
    CX1005024V-LF 1" x 1/2" Copper outlets with a 1/2" Lead free PEX Valve
    CX1255024V-LF 1 1/4" x 1/2" Copper outlets with a 1/2" Lead free PEX Valve
    CX1505024V-LF 1 1/2" x 1/2" Copper outlets with a 1/2" Lead free PEX Valve
    CX2005024V-LF 2" x 1/2" Copper outlets with a 1/2" Lead free PEX Valve
    
    1" or 1 1/4" Copper Header with 2-12 1/2" Lead Free PEX Valves on 2" Centers
    CVP1005002-LF
    CVP1005003-LF
    CVP1005004-LF
    CVP1005005-LF
    CVP1005006-LF
    CVP1005007-LF
    CVP1005008-LF
    CVP1005009-LF
    CVP1005010-LF
    CVP1005011-LF
    CVP1005012-LF
    CVP1255002-LF
    CVP1255002-LF
    CVP1255003-LF
    CVP1255004-LF
    CVP1255005-LF
    CVP1255006-LF
    CVP1255007-LF
    CVP1255008-LF
    CVP1255009-LF
    CVP1255010-LF
    CVP1255011-LF
    CVP1255012-LF
    



 
Action Technology 
10610 State Highway 10
Clinton, IL 61727 
United States 
217-935-1066


Facility : Clinton, IL

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Tubing/Hose
AT Alpha PE Series .17" - .5" D. HOT PE



 
Activated Carbon Solutions Inc 
5757 West Century Boulevard
Suite700 
Los Angeles, CA 90045 
United States 
424-419-4009
Visit this company's website


Facility : # 1 India

Process Media

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Granular Activated Carbon[1]
WAC-1020 [3] CLD 23 GAC
WAC-1020 CAT [2] CLD 23 GAC
WAC-1020 WW [3] CLD 23 GAC
WAC-1030 [3] CLD 23 GAC
WAC-1030 CAT [2] CLD 23 GAC
WAC-1030 WW [3] CLD 23 GAC
WAC-1032 CAT [2] CLD 23 GAC
WAC-1220 [3] CLD 23 GAC
WAC-1220 CAT [2] CLD 23 GAC
WAC-1220 WW [3] CLD 23 GAC
WAC-1230 [3] CLD 23 GAC
WAC-1230 WW [3] CLD 23 GAC
WAC-1235 CAT [2] CLD 23 GAC
WAC-1240 [3] CLD 23 GAC
WAC-1240 WW [3] CLD 23 GAC
WAC-1830 CAT [2] CLD 23 GAC
WAC-1835 CAT [2] CLD 23 GAC
WAC-2050 CAT [2] CLD 23 GAC
WAC-3010 CAT [2] CLD 23 GAC
WAC-3014 CAT [2] CLD 23 GAC
WAC-3070 CAT [2] CLD 23 GAC
WAC-3080 CAT [2] CLD 23 GAC
WAC-4080 [3] CLD 23 GAC
WAC-4080 WW [3] CLD 23 GAC
WAC-410 CAT [2] CLD 23 GAC
WAC-610 CAT [2] CLD 23 GAC
WAC-616 CAT [2] CLD 23 GAC
WAC-816 [3] CLD 23 GAC
WAC-816 WW [3] CLD 23 GAC
WAC-820 [3] CLD 23 GAC
WAC-820 CAT [2] CLD 23 GAC
WAC-820 WW [3] CLD 23 GAC
WAC-830 [3] CLD 23 GAC
WAC-840 [3] CLD 23 GAC
WAC-840 CAT [2] CLD 23 GAC
WAC-840 WW [3] CLD 23 GAC

[1] The carbon source is coconut shell.
[2] Certified for mesh sizes: 4 x 10, 6 x 16, 8 x 20, 8 x 40, 10 x 20, 10 x 30, 10 x 32, 12
    x 20, 12 x 35, 12 x 40, 18 x 30, 18 x 35, 20 x 50, 30 x 70, 30 x 80, 30 x 100, 30 x 140.
[3] Certified for mesh sizes: 4 x 8, 4 x 10, 6 x 10, 6 x 12, 6 x 16, 8 x 16, 8 x 20, 8 x 40,
    8 x 30, 10 x 20, 10 x 30, 10 x 32, 12 x 20, 12 x 30, 12 x 35, 12 x 40, 14 x 35, 18 x 30,
    18 x 35, 18 x 40, 20 x 40, 20 x 50, 30 x 20, 30 x 60, 30 x 70, 30 x 80, 30 x 100, 30 x
    140, 35 x 60, 40 x 80, 40 x 100, 40 x 140, 50 x 100, 50 x 200, 60 x 140, 60 x 200, 60 x
    320, 80 x 200, 80 x 325, -100, -200, -325.

Powdered Activated Carbon[1]
WAC-200 [3] CLD 23 PAC
WAC-325 [3] CLD 23 PAC
WAC-5020 WW [3] CLD 23 PAC
WAC-8020 [3] CLD 23 PAC
WAC-8032 [3] CLD 23 PAC

[1] The carbon source is coconut shell.
[3] Certified for mesh sizes: 4 x 8, 4 x 10, 6 x 10, 6 x 12, 6 x 16, 8 x 16, 8 x 20, 8 x 40,
    8 x 30, 10 x 20, 10 x 30, 10 x 32, 12 x 20, 12 x 30, 12 x 35, 12 x 40, 14 x 35, 18 x 30,
    18 x 35, 18 x 40, 20 x 40, 20 x 50, 30 x 20, 30 x 60, 30 x 70, 30 x 80, 30 x 100, 30 x
    140, 35 x 60, 40 x 80, 40 x 100, 40 x 140, 50 x 100, 50 x 200, 60 x 140, 60 x 200, 60 x
    320, 80 x 200, 80 x 325, -100, -200, -325.

NOTE: Certified for water treatment plant applications.
      This product has not been evaluated for point of use applications.


 
Activcarb 
SF No. 270/ 1, Chinnaputhur
Dharapuram, Dist Tirupur 
Tamil Nadu 638657 
India 
91 999 4063307


Facility : Tamil Nadu, India

Process Media

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Granular Activated Carbon[1]
Acb100 [2] CLD 23 GAC
Acb40 [2] CLD 23 GAC
Acb45 [2] CLD 23 GAC
Acb50 [2] CLD 23 GAC
Acb55 [2] CLD 23 GAC
Acb60 [2] CLD 23 GAC
Acb65 [2] CLD 23 GAC
Acb70 [2] CLD 23 GAC
Acb75 [2] CLD 23 GAC
Acb80 [2] CLD 23 GAC
Acb85 [2] CLD 23 GAC
Acb90 [2] CLD 23 GAC
Acb95 [2] CLD 23 GAC

[1] The carbon source is coconut shell.
[2] Certified for the following mesh sizes: 3x6, 3x30, 6x8, 4x8, 6x12, 6x16, 8x16, 8x20,
    8x30, 12x30, 12x40, 14x25, 16x35, 16x40, 18x35, 18x40, 20x40, 20x50, 20x60, 20x70,
    30x50, 30x60, 30x70, 30x80, 35x60, 35x70 and 40x80.

Powdered Activated Carbon[1]
Acb1000 [3] CLD 23 PAC
Acb1050 [3] CLD 23 PAC
Acb1100 [3] CLD 23 PAC
Acb1150 [3] CLD 23 PAC
Acb1200 [3] CLD 23 PAC
Acb1250 [3] CLD 23 PAC
Acb1300 [3] CLD 23 PAC
Acb1350 [3] CLD 23 PAC
Acb1400 [3] CLD 23 PAC
Acb1450 [3] CLD 23 PAC
Acb1500 [3] CLD 23 PAC
Acb950 [3] CLD 23 PAC

[1] The carbon source is coconut shell.
[3] Certified for the following mesh sizes: 40x140, 50x140, 50x200, 80x140, 80x200, 80x325,
    100x325, -200 and -325.

NOTE: Certified for water treatment plant applications.
      This product has not been evaluated for point of use applications.


 
Active Char Products Pvt. Ltd. 
B No. 615, IDA
Binanipuram, Edayar 
Ernakulam, Kerala 683502 
India 
91 484 2556514
Visit this company's website


Facility : Ernakulam, Kerala, India

Process Media

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Granular Activated Carbon[1]
MF CARB CT 820 [2] CLD 23 GAC
MF CARB CT 1020 [2] CLD 23 GAC
MF CARB CT 1030 [2] CLD 23 GAC
MF CARB CT 1032 [2] CLD 23 GAC
MF CARB CT 1220 [2] CLD 23 GAC
MF CARB CT 1235 [2] CLD 23 GAC
MF CARB CT 1830 [2] CLD 23 GAC
MF CARB CT 1835 [2] CLD 23 GAC
MF CARB CT 2050 [2] CLD 23 GAC
MF CARB CT 3010 [2] CLD 23 GAC
MF CARB CT 3014 [2] CLD 23 GAC
MF CARB CT 3070 [2] CLD 23 GAC
MF CARB CT 3080 [2] CLD 23 GAC
MF CARB CT 410 [2] CLD 23 GAC
MF CARB CT 610 [2] CLD 23 GAC
MF CARB CT 616 [2] CLD 23 GAC
MF CARB CT 840 [2] CLD 23 GAC
MF CARB WT 1020 [3] CLD 23 GAC
MF CARB WT 1020 WW [3] CLD 23 GAC
MF CARB WT 1030 [3] CLD 23 GAC
MF CARB WT 1030 WW [3] CLD 23 GAC
MF CARB WT 1032 [3] CLD 23 GAC
MF CARB WT 1032 WW [3] CLD 23 GAC
MF CARB WT 1220 [3] CLD 23 GAC
MF CARB WT 1220 WW [3] CLD 23 GAC
MF CARB WT 1230 [3] CLD 23 GAC
MF CARB WT 1230 WW [3] CLD 23 GAC
MF CARB WT 1235 [3] CLD 23 GAC
MF CARB WT 1235 WW [3] CLD 23 GAC
MF CARB WT 1240 [3] CLD 23 GAC
MF CARB WT 1240 WW [3] CLD 23 GAC
MF CARB WT 1435 [3] CLD 23 GAC
MF CARB WT 1435 WW [3] CLD 23 GAC
MF CARB WT 1830 [3] CLD 23 GAC
MF CARB WT 1830 WW [3] CLD 23 GAC
MF CARB WT 1835 [3] CLD 23 GAC
MF CARB WT 1835 WW [3] CLD 23 GAC
MF CARB WT 1840 [3] CLD 23 GAC
MF CARB WT 1840 WW [3] CLD 23 GAC
MF CARB WT 2040 [3] CLD 23 GAC
MF CARB WT 2040 WW [3] CLD 23 GAC
MF CARB WT 2050 [3] CLD 23 GAC
MF CARB WT 2050 WW [3] CLD 23 GAC
MF CARB WT 3010 [3] CLD 23 GAC
MF CARB WT 3010 WW [3] CLD 23 GAC
MF CARB WT 3014 [3] CLD 23 GAC
MF CARB WT 3014 WW [3] CLD 23 GAC
MF CARB WT 3020 [3] CLD 23 GAC
MF CARB WT 3020 WW [3] CLD 23 GAC
MF CARB WT 3060 [3] CLD 23 GAC
MF CARB WT 3060 WW [3] CLD 23 GAC
MF CARB WT 3070 [3] CLD 23 GAC
MF CARB WT 3070 WW [3] CLD 23 GAC
MF CARB WT 3080 [3] CLD 23 GAC
MF CARB WT 3080 WW [3] CLD 23 GAC
MF CARB WT 3560 [3] CLD 23 GAC
MF CARB WT 3560 WW [3] CLD 23 GAC
MF CARB WT 4010 [3] CLD 23 GAC
MF CARB WT 4010 WW [3] CLD 23 GAC
MF CARB WT 4014 [3] CLD 23 GAC
MF CARB WT 4014 WW [3] CLD 23 GAC
MF CARB WT 4080 [3] CLD 23 GAC
MF CARB WT 4080 WW [3] CLD 23 GAC
MF CARB WT 410 [3] CLD 23 GAC
MF CARB WT 410 WW [3] CLD 23 GAC
MF CARB WT 48 [3] CLD 23 GAC
MF CARB WT 48 WW [3] CLD 23 GAC
MF CARB WT 5010 [3] CLD 23 GAC
MF CARB WT 5010 WW [3] CLD 23 GAC
MF CARB WT 610 [3] CLD 23 GAC
MF CARB WT 610 WW [3] CLD 23 GAC
MF CARB WT 612 [3] CLD 23 GAC
MF CARB WT 612 WW [3] CLD 23 GAC
MF CARB WT 616 [3] CLD 23 GAC
MF CARB WT 616 WW [3] CLD 23 GAC
MF CARB WT 816 [3] CLD 23 GAC
MF CARB WT 816 WW [3] CLD 23 GAC
MF CARB WT 820 [3] CLD 23 GAC
MF CARB WT 820 WW [3] CLD 23 GAC
MF CARB WT 830 WW [3] CLD 23 GAC
MF CARB WT 840 [3] CLD 23 GAC
MF CARB WT 840 WW [3] CLD 23 GAC
MF CARB WT B830 [3] CLD 23 GAC

[1] The carbon source is coconut shell.
[2] Certified for mesh sizes: 4 x 10, 6 x 16, 8 x 20, 8 x 40, 10 x 20, 10 x 30, 10 x 32, 12
    x 20, 12 x 35, 12 x 40, 18 x 30, 18 x 35, 20 x 50, 30 x 70, 30 x 80,
    30 x 100, 30 x 140.
[3] Certified for mesh sizes: 4 x 8, 4 x 10, 6 x 10, 6 x 12, 6 x 16, 8 x 16, 8 x 20, 8 x 40,
    8 x 30, 10 x 20, 10 x 30, 10 x 32, 12 x 20, 12 x 30, 12 x 35, 12 x 40, 14 x 35, 18 x 30,
    18 x 35, 18 x 40, 20 x 40, 20 x 50, 30 x 20, 30 x 60, 30 x 70, 30 x 80, 30 x 100, 30 x
    140, 35 x 60, 40 x 80, 40 x 100, 40 x 140, 50 x 100, 50 x 200, 60 x 140, 60 x 200, 60 x
    320, 80 x 200, 80 x 325, -100, -200, -325.

Powdered Activated Carbon[1]
MF CARB WT -200 [3] CLD 23 PAC
MF CARB WT -200 WW [3] CLD 23 PAC
MF CARB WT -325 [3] CLD 23 PAC
MF CARB WT -325 WW [3] CLD 23 PAC
MF CARB WT 5020 [3] CLD 23 PAC
MF CARB WT 5020 WW [3] CLD 23 PAC
MF CARB WT 6014 [3] CLD 23 PAC
MF CARB WT 6014 WW [3] CLD 23 PAC
MF CARB WT 6020 [3] CLD 23 PAC
MF CARB WT 6020 WW [3] CLD 23 PAC
MF CARB WT 6032 [3] CLD 23 PAC
MF CARB WT 6032 WW [3] CLD 23 PAC
MF CARB WT 8020 [3] CLD 23 PAC
MF CARB WT 8020 WW [3] CLD 23 PAC
MF CARB WT 8032 [3] CLD 23 PAC
MF CARB WT 8032 WW [3] CLD 23 PAC
MF CARB WT PAC [3] CLD 23 PAC
MF CARB WT PAC WW [3] CLD 23 PAC

[1] The carbon source is coconut shell.
[3] Certified for mesh sizes: 4 x 8, 4 x 10, 6 x 10, 6 x 12, 6 x 16, 8 x 16, 8 x 20, 8 x 40,
    8 x 30, 10 x 20, 10 x 30, 10 x 32, 12 x 20, 12 x 30, 12 x 35, 12 x 40, 14 x 35, 18 x 30,
    18 x 35, 18 x 40, 20 x 40, 20 x 50, 30 x 20, 30 x 60, 30 x 70, 30 x 80, 30 x 100, 30 x
    140, 35 x 60, 40 x 80, 40 x 100, 40 x 140, 50 x 100, 50 x 200, 60 x 140, 60 x 200, 60 x
    320, 80 x 200, 80 x 325, -100, -200, -325.

NOTE: Certified for water treatment plant applications.
      This product has not been evaluated for point of use applications.


 
Adam Carbons Ltd. 
264, Grandpass Road
Colombo 14 
Sri Lanka 
94 72 7434464
Visit this company's website


Facility : Giriulla, Sri Lanka

Process Media

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Granular Activated Carbon[1]
AC Virgin Granular [2] CLD 23 CARBON
AC Virgin Granular Acid Washed [2] CLD 23 CARBON
AC Virgin Granular Impregnated [2] CLD 23 CARBON

[1] The carbon source is coconut shell.
[2] Certified for the following mesh sizes: 4x8, 8x16, 8x30, 12x30, 12x40, 30x60, 30x80,
    40x80.

NOTE: Certified for water treatment plant applications.
      This product has not been evaluated for point of use applications.


 
AdEdge Technologies, Inc. 
5152 Belle Wood Court
Suites A 
Burford, GA 30518 
United States 
678-835-0052


Facility : Quincy, IL

Process Media

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Oxidative Media
AD26 [1] CLD 23 MNDOX

[1] Certified for the following mesh sizes: 8 x 20, 20 x 40.

NOTE: Certified for water treatment plant applications.
      This product has not been evaluated for point of use applications.


 
Adept Fluidyne Pvt. Ltd. 
Plot 4, S No. 17/1 - B, Kothrud
Industrial Estate, Pune 
Maharashtra 411 038 
India 
91 202 5464551
Visit this company's website


Facility : Pune, Maharashtra, India

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Water Meters
MagBP 6440 PP 25 mm - 500 mm CLD 23 MLTPL
MagFlow 6410 PP 25 mm - 500 mm CLD 23 MLTPL
MagFlow 6415 PP 25 mm - 500 mm CLD 23 MLTPL



 
Adhesive R&D, Inc. 
4603 Anderson Drive
Eau Claire, WI 54703 
United States 
715-832-4557
Visit this company's website


Facility : Eau Claire, WI

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Thread Compounds
DFM 555 [1] CLD 23 SLT
DFM 63 [1] CLD 23 SLT
DFM 64 [1] CLD 23 SLT
DFM 65 [1] CLD 23 SLT
DFM 66 [1] CLD 23 SLT
DFM 67 [1] CLD 23 SLT
DFM 68 [1] CLD 23 SLT
FMB64 [1] CLD 23 SLT
FMB65 [1] CLD 23 SLT
FMB66 [1] CLD 23 SLT
RubberMAX iPipe 70 [1] CLD 23 SLT
RubberMAX iPipe 71 [1] CLD 23 SLT
RubberMAX iPipe 72 [1] CLD 23 SLT
RubberMAX iPipe 73 [1] CLD 23 SLT

[1] Certified for a maximum of 18.5 joints per liter.



 
Adhesives Technology Corp. 
450 East Copans Road
Pompano Beach, FL 33064 
United States 
954-461-2335


Facility : # 2 Germany

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Adhesives
ULTRABOND ACRYL-8CC [1] D. HOT VE
ULTRABOND HYB-2CC [1] C. HOT PUR

[1] Certified for use as an anchoring adhesive for installing thread rods (less than or
    equal to 1.3 inches in diameter) in concrete or masonry for water treatment applications.

NOTE: Only products bearing the NSF Mark on the products, product packaging, and/or
      documentation shipped with the product are certified.


Adhesives Technology Corp. (ATC) 
450 East Copans Road
Pompano Beach, FL 33064 
United States 
800-892-1880 
Visit this company's website


Facility : # 1 Germany

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Adhesives
ULTRABOND 365CC 13.2 fl. oz. [1] C. HOT VE
ULTRABOND 365CC 19.8 fl. oz. [1] C. HOT VE

[1] Certified for use as an anchoring adhesive for installing threaded rods (less than or
    equal to 6 mm - 36 mm or 1/4" - 1-3/8" in diameter) in concrete for water treatment
    applications.



 
Adolf Würth GmbH & Co. KG 
Produktmanagement Chemie, Postfach
74650 Künzelsau 
Germany 
49 794 015 2007


Facility : # 1 Switzerland

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Adhesives
Würth® DOS Lagersicherung hochfest (0893 603) >= 1/2" C. HOT ADH
Würth® DOS Flächendicht orange (0893 574) >= 1/2" C. HOT ADH
Würth® DOS Klebfix EASY PEN (0893 090) >= 1/2" CLD 23 ADH
Würth® DOS Klebfix (0893 09) >= 1/2" CLD 23 ADH
Würth® DOS Schraubensicherung Hochfest >= 1/2" C. HOT ADH
Würth® DOS Schraubensicherung Mittelfest >= 1/2" C. HOT ADH
Würth Rohrdicht PLUS (0893 577 300) >= 1/2" C. HOT ADH

Sealants
Würth® DOS Flächendicht grün (0893 573) >= 1/2" C. HOT SLT

Thread Compounds
Würth® DOS Rohrdicht mit PTFE >= 1/2" C. HOT TC
Würth® DOS Rohrdicht[1] >= 1/2" C. HOT TC
Würth® DOS Schraubensicherung Hochfest >= 1/2" C. HOT TC

[1] Certification is based on a minimum cure of 72 hours at 75°F.



 
Adolf Würth GmbH & Co. KG 
Reinhold-Würth-Str. 12-16
74653 Künzelsau-Gaisbach 
Germany 
49 7940 15 0


Facility : # 2 Germany

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Adhesives
Atrion AVM TOP QUATTRO [1] D. HOT VE
WIT-PE 1000 [1] D. HOT EPOXY
WIT-PE 500 [1] D. HOT EPOXY
WIT-UH 300 [1] C. HOT PUR
WIT-VH 300 [1] C. HOT PUR
WIT-VM 250 [1] D. HOT VE
WIT-VM 300 [1] C. HOT PUR

[1] Certified for use as an anchoring adhesive for installing thread rods (less than or
    equal to 1.3 inches in diameter) in concrete or masonry for water treatment applications.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Adolf Würth GmbH & Co. KG 
Reinhold-Würth-Strasse 12-17
D-74650 Künzelsau, Baden-Wurttemberg 
Germany 
49 7940150
Visit this company's website


Facility : # 1 Germany

Joining and Sealing Materials

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Sealants[G]
SILICONE ACETATE, FOOD GRADE / ACETATSILIKON LEBENSMITTEL >= 1/2" CLD 23 SLT

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Advance Products & Systems 
108 Asset Avenue
Scott, LA 70583 
United States 
800-315-6009 
337-233-6116
Visit this company's website