NSF Product and Service Listings

These NSF Official Listings are current as of Sunday, January 20, 2019 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=03240&Standard=061&



NSF/ANSI 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings.


 
LifeLast, Inc. 
3813 Helios Way
Suite 190 
Pflugerville, TX 78660 
United States 
512.628.2112
Visit this company's website


Facility : # 1 USA

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings
DuraShield 210-61[1] >= 2" CLD 23 PUR
DuraShield 310-61[1] >= 2" CLD 23 PUR

[1] Colors: Almond, Black, Gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 250
    Final Cure Time and Temperature: 72 hours at 75°F
    Special Comments: Mix ratio of Part A:Part B of 210-61 is 2:1 by volume and mix ratio of
    Part A:Part B of 310-61 is 3:1 by volume. Minimum certified field use dry film thickness
    is 20 mils.

Coatings - Pipe
DuraShield 210-61[1] >= 8" CLD 23 PUR
DuraShield 310-61[1] >= 8" CLD 23 PUR

[1] Colors: Almond, Black, Gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 250
    Final Cure Time and Temperature: 72 hours at 75°F
    Special Comments: Mix ratio of Part A:Part B of 210-61 is 2:1 by volume and mix ratio of
    Part A:Part B of 310-61 is 3:1 by volume. Minimum certified field use dry film thickness
    is 20 mils.

Coatings - Tank
DuraShield 210-61[1] >= 50 gal. CLD 23 PUR
DuraShield 310-61[1] >= 50 gal. CLD 23 PUR

[1] Colors: Almond, Black, Gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 250
    Final Cure Time and Temperature: 72 hours at 75°F
    Special Comments: Mix ratio of Part A:Part B of 210-61 is 2:1 by volume and mix ratio of
    Part A:Part B of 310-61 is 3:1 by volume. Minimum certified field use dry film thickness
    is 20 mils.

Coatings - Valve
DuraShield 210-61[1] >= 2" CLD 23 PUR
DuraShield 310-61[1] >= 2" CLD 23 PUR

[1] Colors: Almond, Black, Gray
    Number of Coats: 1
    Maximum Field Use Dry Film Thickness (in mils): 250
    Final Cure Time and Temperature: 72 hours at 75°F
    Special Comments: Mix ratio of Part A:Part B of 210-61 is 2:1 by volume and mix ratio of
    Part A:Part B of 310-61 is 3:1 by volume. Minimum certified field use dry film thickness
    is 20 mils.