NSF Product and Service Listings
These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=0B750&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
DMT Co., Ltd. | |
27, Namdongdong-ro | |
77 Beon-gil | |
Namdong-gu, Incheon 405-821 | |
Korea, Republic of | |
82 32 812 7311 |
Facility : Incheon, Republic of Korea
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Valves[G] |
||||
ACHV 0404 | 1/4" x 1/4" | D. HOT | MLTPL | |
ACHV 0405 | 1/4" x 5/16" | D. HOT | MLTPL | |
ACHV 0505 | 5/16" x 5/16" | D. HOT | MLTPL | |
ACHV 0606 | 3/8" x 3/8" | D. HOT | MLTPL | |
ACHV 0606M | 6 mm x 6 mm | D. HOT | MLTPL | |
ACHV 0707 | 1/2" x 1/2" | D. HOT | MLTPL | |
ACHV 0808M | 8 mm x 8 mm | D. HOT | MLTPL | |
ACHV 1010M | 10 mm x 10 mm | D. HOT | MLTPL | |
ACHV 1212M | 12 mm x 12 mm | D. HOT | MLTPL | |
ADCHV 1515M | 15 mm x 15 mm | D. HOT | MLTPL | |
AMCHV 0402W | 1/4" x 1/8" | D. HOT | MLTPL | |
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Mechanical Plumbing Devices
Trade Designation | ||||
Faucet, Miscellaneous Faucet Components[1] [G] |
||||
ADMF 0404[Q] | ||||
ADMF 0505 | ||||
ADMF 0606 | ||||
ADMF 0606 M | ||||
ADMF 0707 | ||||
ADMF 0808 M | ||||
ADMF 1010 M | ||||
ADMF 1212 M | ||||
[Q] This product meets the reduced Q test statistic criteria of 0.5 µg for lead per Section 9.5.1.1 of NSF/ANSI/CAN 61. |
||||
[1] Trade names follow the convention ADMF XX XX where the first XX is the outer diameter of the inlet port , and the second XX is the outer diameter of the outlet port. Trade names followed by an M have ports measured in metric (size codes are 06 - 6mm, 08 - 8mm, 10 - 10mm, and 12 - 12mm), those without an M are measured in standard units: (size codes are 04 - 1/4in, 05 - 5/16in, 06 - 3/8in, and 07 - 1/2in). Assemblies with metric measurements have black bodies, while standard measurement assemblies have grey bodies. This product is a Filter Strainer. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||
Supply Stops[2] [G] |
||||
AHBC0807 | ||||
AHBC1007 | ||||
AHBC1009 | ||||
AHBC1507M | ||||
AHBC2107M | ||||
AHBC2109M | ||||
AHBC2207M | ||||
AHBC2209M | ||||
AHFA0404 | ||||
AHFA0604M | ||||
AHFA0606 | ||||
AHFA0607 | ||||
AHFA0706 | ||||
AHFA0707 | ||||
AHFA0806 | ||||
AHFA0807 | ||||
AHFA1006M | ||||
AHFA1007M | ||||
AHFA1206M | ||||
AHFA1207M | ||||
AHFA1506M | ||||
AHFA1507M | ||||
AHFA1606M | ||||
AHFA1607M | ||||
AHFAUC0607 | ||||
AHFAUC1007M | ||||
AHMC0404 | ||||
AHMC0604M | ||||
AHMC0606 | ||||
AHMC0707 | ||||
AHMC1006M | ||||
AHMC1207M | ||||
AHSV1515M | ||||
AHSV2115M | ||||
AHSV2215M | ||||
AHUC0404 | ||||
AHUC0606 | ||||
AHUC0606M | ||||
AHUC0707 | ||||
AHUC0806 | ||||
AHUC0807 | ||||
AHUC0808 | ||||
AHUC1010 | ||||
AHUC1010M | ||||
AHUC1212M | ||||
AHUC1510M | ||||
AHUC1512M | ||||
AHUC1515M | ||||
AHUC1610M | ||||
AHUC1616M | ||||
AHUC16M06 | ||||
AHUC16M07 | ||||
AHUC16M08 | ||||
AHUC2222M | ||||
AHUCS0606 | ||||
AHVEU0608 | ||||
AHVMCB1509M | ||||
AHWM0809 | ||||
ATHC1515M | ||||
ATWV080808 | ||||
ATWV121212M | ||||
ATWV161616M | ||||
[2] The M at the end or middle of the part number represents metric. The A at the beginning of each part number represents acetal. The A is followed by an abbreviation of the valve design. Metric size (mm or mm x in) valves are black; British size (in) valves are white. Valve design abbreviations: HMC - Hand valve male connector (NPTF threads) HUC - Hand valve union connector HUCS - Hand valve union connector, short handle HFA - Hand valve female adapter (NPTF threads) HFAUC - Hand valve female adapter (union connector) HVEU - Hand valve elbow union HWM - Hand valve washing M/C TWV - Three-way valve HBC - Hand barb connector HSV - Hand valve stop connector THC - Throttle hand valve connector [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||
Valves[3] [G] |
||||
ABCEU[XX][YY] Bulkhead Control Valve Elbow Union | ||||
ABCEU[XX][YY]M Bulkhead Control Valve Elbow Union | ||||
ABCFA[XX][YY] Bulkhead Control Valve Female Adapter | ||||
ABCFA[XX][YY]M Bulkhead Control Valve Female Adapter | ||||
ABCMC[XX][YY] Bulkhead Control Valve Male Connector | ||||
ABCMC[XX][YY]M Bulkhead Control Valve Male Connector | ||||
ABCUC[XX][YY] Bulkhead Control Valve Union Connector | ||||
ABCUC[XX][YY]M Bulkhead Control Valve Union Connector | ||||
ACEU[XX][YY] Control Valve Elbow Union | ||||
ACEU[XX][YY]M Control Valve Elbow Union | ||||
ACFA[XX][YY] Control Valve Female Adapter | ||||
ACFA[XX][YY]M Control Valve Female Adapter | ||||
ACMC[XX][YY] Control Valve Male Connector | ||||
ACMC[XX][YY]M Control Valve Male Connector | ||||
ACUC[XX][YY] Control Valve Union Connector[Q] | ||||
ACUC[XX][YY]M Control Valve Union Connector | ||||
[Q] This product meets the reduced Q test statistic criteria of 0.5 µg for lead per Section 9.5.1.1 of NSF/ANSI/CAN 61. |
||||
[3] [XX] & [YY] Specify Connection Size: 0404 - 1/4" x 1/4" 0606 - 3/8" x 3/8" 0604M - 6 mm x 1/4" 0606M - 6 mm x 6 mm 1006M - 10 mm x 3/8" 1010M - 10 mm x 10 mm [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Pipes and Related Products
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Fittings [G] |
||||
ABBC [XX][YY]M-B[3] [4] | 12mmx10" - 16mmx10"[5] | D. HOT | MLTPL | |
ABBC [XX][YY][Z][1] [2] | 5/8"x1/2"-7/8"x3/4" | D. HOT | MLTPL | |
ABFU [XX][YY][Z][1] [2] | 1/4" x 3/4" | D. HOT | MLTPL | |
ABTU[XX][YY][Z][1] [2] | 1/4" - 1/2" | D. HOT | MLTPL | |
ABU [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
ABU [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
ACIBEU [XX][YY][Z][1] [2] | 5/16" - 3/8" | D. HOT | MLTPL | |
ACIBUC [XX][YY][Z][1] [2] | 5/16 - 3/8 in | D. HOT | MLTPL | |
ACIMCBT [XX][YY][Z][1] [2] | 5/16" x 1/4" | D. HOT | MLTPL | |
ACIMCF [XX][YY][Z][1] [2] | 5/16"x¼"-5/16"x3/8" | D. HOT | MLTPL | |
ACIMCW [XX][YY][Z][1] [2] | 5/16"x9/16"-¿"x9/16" | D. HOT | MLTPL | |
ACR [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
ACR [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
AC[XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
AC[XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
ADA [XX][YY]M-B[3] [4] | 15mmx3/4"-16mmx3/4" | D. HOT | MLTPL | |
ADA [XX][YY][Z][1] [2] | 5/8" x 3/4" | D. HOT | MLTPL | |
ADEU [XX][YY][Z][1] [2] | 3/8" | D. HOT | MLTPL | |
AEL [XX][YY]M-B[3] [4] | 15mmx10"-28mmx22"[6] | D. HOT | MLTPL | |
AEL [XX][YY][Z][1] [2] | 3/8"x5/16"-1/2"x3/8" | D. HOT | MLTPL | |
AEU [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
AEU [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
AFA [XX][YY]M-B[3] [4] | 6mmx1/8" - 22mmx1" | D. HOT | MLTPL | |
AFA [XX][YY][Z][1] [2] | 1/4"x1/8"-3/8"x1/4" | D. HOT | MLTPL | |
AFAB [XX][YY]C[Z] | 1/4"-5/8" | D. HOT | MLTPL | |
AFAB [XX][YY]F[Z] | 5/16"-5/8" | D. HOT | MLTPL | |
AFAB [XX][YY]F[Z]-1 | 1/4"-3/4" | D. HOT | MLTPL | |
AFAB[XX][YY]FM[3] [4] | 6mmx3/4" - 12mmx5/8" | D. HOT | MLTPL | |
AFAB[XX][YY]F[Z][1] [2] | 1/4" - 5/8" | D. HOT | MLTPL | |
AFAN[XX][YY]FM[3] [4] | 6mm - 10mm | D. HOT | MLTPL | |
AFAN[XX][YY]F[Z] | 1/4" - 5/8" | D. HOT | MLTPL | |
AFAU [XX][YY] C [Z][1] [2] | ¼"x7/16" -3/8"x7/16" | D. HOT | MLTPL | |
AFAU [XX][YY]CM-B[3] [4] | 6mmx7/16"-10mmx7/16" | D. HOT | MLTPL | |
AFAUF [XX][YY] C [Z][1] [2] | ¼"x7/16"-3/8"x7/16" | D. HOT | MLTPL | |
AFAUF [XX][YY] V [Z][1] [2] | 1/4"x7/16"-3/8"x5/8" | D. HOT | MLTPL | |
AFAUF [XX][YY]CM-B[3] [4] | 6mmx7/16"-10mmx7/16" | D. HOT | MLTPL | |
AFAUF [XX][YY]VM-B[3] [4] | 6mmx7/16"-10mmx7/16" | D. HOT | MLTPL | |
AFAUN [XX][YY] V [Z][1] [2] | 3/8"x1/2"-1/2"x1/2" | D. HOT | MLTPL | |
AFAUN [XX][YY]VM-B[3] [4] | 8mmx1/2"-12mmx1/2" | D. HOT | MLTPL | |
AFC [XX][YY][Z][1] [2] | 1/4" | D. HOT | MLTPL | |
AFR [XX][YY][Z][1] [2] | 5/16" x 1/4" | D. HOT | MLTPL | |
AFWC [XX][YY]M-B[3] [4] | 22mm x 10mm | D. HOT | MLTPL | |
AHA [XX][YY]M-B[3] [4] | 22mm x 1" | D. HOT | MLTPL | |
AHA [XX][YY][Z][1] [2] | 7/8" x 1" | D. HOT | MLTPL | |
AKFA [XX][YY][Z][1] [2] | 1/4"x1/2"-3/8"x1/2" | D. HOT | MLTPL | |
AMC [XX][YY]M-B[3] [4] | 4mmx1/8"-12mmx1/2" | D. HOT | MLTPL | |
AMC [XX][YY][Z][1] [2] | 5/32"x1/8"-1/2"x1/2" | D. HOT | MLTPL | |
AMCB [XX][YY]M-B[3] [4] | 4mmx1/8"-12mmx1/2" | D. HOT | MLTPL | |
AMCB [XX][YY][Z][1] [2] | 5/32"x1/8"-1/2"x1/2" | D. HOT | MLTPL | |
AMCBB [XX][YY][Z][1] [2] | 3/8"x1/8"-3/8"x1/4" | D. HOT | MLTPL | |
AMCBT [XX][YY][Z][1] [2] | 5/32"x1/8"-1/2"x1/2" | D. HOT | MLTPL | |
AMCF [XX][YY][Z][1] [2] | 5/16"x5/16"-3/8"x½" | D. HOT | MLTPL | |
AMCW [XX][YY][Z][1] [2] | ¼"x9/16"-3/8"x9/16" | D. HOT | MLTPL | |
AME [XX][YY]M-B[3] [4] | 6mmx1/8"-12mmx1/2" | D. HOT | MLTPL | |
AME [XX][YY][Z][1] [2] | 3/16"x1/8"-1/2"x1/2" | D. HOT | MLTPL | |
AMTU [XX][YY][Z][1] [2] | 1/4" | D. HOT | MLTPL | |
AMTUR[XX][YY][Z][1] [2] | 1/4" - 3/8" | D. HOT | MLTPL | |
AOC [XX][YY]M-B[3] [4] | 10mmx6" - 12mmx8" | D. HOT | MLTPL | |
AOC [XX][YY][Z][1] [2] | 3/8"x1/4"-1/2"x5/16" | D. HOT | MLTPL | |
APBBC [XX][YY][Z][1] [2] | 1/4"x1/4"-3/8"x1/4" | D. HOT | MLTPL | |
APBEU [XX][YY]M-B[3] [4] | 8mm - 10mm | D. HOT | MLTPL | |
APBEU [XX][YY][Z][1] [2] | 5/16" - 3/8" | D. HOT | MLTPL | |
APBUC [XX][YY]M-B[3] [4] | 8mm - 10mm | D. HOT | MLTPL | |
APBUC [XX][YY][Z][1] [2] | 5/16" - 3/8" | D. HOT | MLTPL | |
APL [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
APL [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
APMCBT [XX][YY][Z][1] [2] | 5/16" x 1/4" | D. HOT | MLTPL | |
APMCF [XX][YY]M-B[3] [4] | 8mmx1/4" - 8mmx3/8" | D. HOT | MLTPL | |
APMCF [XX][YY][Z][1] [2] | 5/16"x¼"-5/16"x3/8" | D. HOT | MLTPL | |
APMCW [XX][YY]M-B[3] [4] | 8mmx9/16"-10mmx9/16" | D. HOT | MLTPL | |
APMCW [XX][YY][Z][1] [2] | 5/16"x9/16"-¿"x9/16" | D. HOT | MLTPL | |
APSEU [XX][YY][Z][1] [2] | 5/16" - 3/8" | D. HOT | MLTPL | |
APSFBU [XX][YY][Z][1] [2] | 5/16" | D. HOT | MLTPL | |
APSUC [XX][YY]M-B[3] [4] | 8mm - 10mm | D. HOT | MLTPL | |
APSUC [XX][YY][Z][1] [2] | 5/16" - 3/8" | D. HOT | MLTPL | |
ARD [XX][YY]M-B[3] [4] | 4mmx5" - 10mmx12" | D. HOT | MLTPL | |
ARD [XX][YY][Z][1] [2] | 5/32"x1/4"-3/8"x1/2" | D. HOT | MLTPL | |
ASA [XX][YY]M-B[3] [4] | 4mmx1/8" - 12mmx1/2" | D. HOT | MLTPL | |
ASA [XX][YY][Z][1] [2] | 5/32"x1/8"-1/2"x1/2" | D. HOT | MLTPL | |
ASAB [XX][YY]M-B[3] [4] | 4mmx1/8" - 10mmx1/4" | D. HOT | MLTPL | |
ASAB [XX][YY][Z][1] [2] | 3/8"x1/4"-1/2"x1/2" | D. HOT | MLTPL | |
ASABT [XX][YY][Z][1] [2] | 3/16"x1/8"-1/2"x1/2" | D. HOT | MLTPL | |
ASAW [XX][YY][Z][1] [2] | 5/16"x9/16"-¿"x9/16" | D. HOT | MLTPL | |
ASEU [XX][YY]M-B[3] [4] | 15"x1/2" - 16mmx3/4" | D. HOT | MLTPL | |
ASEU [XX][YY][Z][1] [2] | 5/8"x1/4"-7/8"x3/4" | D. HOT | MLTPL | |
ASSA [XX][YY]M-B[3] [4] | 15mm x 3/8" | D. HOT | MLTPL | |
ASTU[XX][YY][Z][1] [2] | 1/4" - 1/2" | D. HOT | MLTPL | |
ASUC [XX][YY]M-B[3] [4] | 15mmx1/2"-22mmx3/4" | D. HOT | MLTPL | |
ASUC [XX][YY][Z][1] [2] | 5/8"x1/2"-5/8"x3/4" | D. HOT | MLTPL | |
ASVA [XX][YY][Z][1] [2] | ¼"x9/16"-3/8"x9/16" | D. HOT | MLTPL | |
ATBC [XX][YY]M-B[3] [4] | 6mmx4" - 12mmx10"[7] | D. HOT | MLTPL | |
ATBC [XX][YY][Z][1] [2] | 1/4"x3/16"-1/2"x1/2" | D. HOT | MLTPL | |
ATC [XX][YY]M-B[3] [4] | 15mm - 28mm | D. HOT | MLTPL | |
ATEB [XX][YY][Z][1] [2] | 1/4"x1/4"-4/8"x5/16" | D. HOT | MLTPL | |
ATES [XX][YY]M-B[3] [4] | 6mm - 12mm | D. HOT | MLTPL | |
ATES [XX][YY][Z][1] [2] | 1/4" - 7/8" | D. HOT | MLTPL | |
ATEU [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
ATEU [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
ATHWD [XX][YY]M-B[3] [4] | 10mmx6" - 12mmx10" | D. HOT | MLTPL | |
ATHWD [XX][YY][Z][1] [2] | 3/8"x1/4"-1/2"x3/8" | D. HOT | MLTPL | |
ATTU [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
ATU [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
ATU [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
ATWD [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
ATWD [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
AUB [XX][YY]M-B[3] [4] | 6mm - 12mm | D. HOT | MLTPL | |
AUB [XX][YY][Z][1] [2] | 1/4" - 1/2" | D. HOT | MLTPL | |
AUC [XX][YY]M-B[3] [4] | 4mm - 12mm | D. HOT | MLTPL | |
AUC [XX][YY][Z][1] [2] | 5/32" - 1/2" | D. HOT | MLTPL | |
BPEU [XX][YY]-W[10] | 1/4" - 1/2" | D. HOT | MLTPL | |
BPUC [XX][YY]-W[10] | 1/4" - 1/2" | D. HOT | MLTPL | |
PEU [XX][YY]-W[10] | 1/4" - 1/2" | D. HOT | MLTPL | |
PFA [XX][YY]-W[10] | 1/4"x1/8"x3/8"x1/4" | D. HOT | MLTPL | |
PFAU [XX][YY]-W[10] | ¼"x7/16"x3/8"x7/16" | D. HOT | MLTPL | |
PMC [XX][YY]-W[10] | 1/4"X1/8"X3/8"X3/8" | C. HOT | MLTPL | |
PME [XX][YY]-W[10] | 1/4"x1/8"x3/8"x3/8" | C. HOT | MLTPL | |
PRD [XX][YY]-W[10] | 1/4"x3/8"x3/8"x1/2" | D. HOT | MLTPL | |
PSA [XX][YY]-W[10] | 1/4" - 1/2" | D. HOT | MLTPL | |
PTEU [XX][YY]-W[10] | 1/4" - 1/2" | D. HOT | MLTPL | |
PTU [XX][YY]-W[10] | 1/4" - 1/2" | D. HOT | MLTPL | |
PUC [XX][YY]-W[10] | 1/4" - 1/2" | D. HOT | MLTPL | |
[1] [XX] represents the inlet diameter size in inches, where [XX] may be any of the following: 01 (5/32") , 03 (3/16"), 04 (1/4"), 05 (5/16"), 06 (3/8"), or 07 (1/2"). For fittings without threads, [YY] represents the outlet diameter size in inches, where [YY] may be any of the following: 01 (5/32"), 03 (3/16"), 04 (1/4"), 05 (5/16"), 06 (3/8"), 07 (1/2"), 08 (5/8"), 09 (3/4"), 10 (7/8"), or 11 (1"). [WW] represents the outer diameter of the inlet in mm, 04 (4 mm) - 12 (12 mm). For fittings with threads, [YY] represents the threaded outlet size in inches, where [YY] may be any of the following: 01 (5/32"), 02 (1/8"), 03 (3/16"), 04 (1/4"), 05 (5/16"), 06 (3/8"), 07 (1/2"), 08 (5/8") , 09 (3/4"), 10 (7/8"), 11 (1"), 7/16 (7/16"), or 9/16 (9/16"). [Z] represents the color of the fitting body, where 'W' represents white and the absence of a letter represents gray. 'SW' represents a silicone o-ring with a white fitting body. For Half Cartridge, ACU [XX], ACP[XX], ACU[WW]M, and ACP[WW]M fittings are approved for a maximum use of 1 unit per liter. ALC [XX] and ALC [YY]M are locking clips and used with fitting products and tubing products. The locking clips are non-wetted. The [XX] refers to the outer diameter of the tube: 03(3/16"), 04(1/4"), 05(5/16"), 06(3/8"), 07(1/2"). 08(5/8"), 10(7/8") and the [YY] refers to the outer diameter of the tube: 05(5mm), 06(6mm), 08(8mm), 10(10mm), 12(12mm), 15(15mm), 16(16mm), 18(18mm), 22(22mm), 28(28mm). [2] Fitting configuration abbreviations: BBC - Barb connector BFU - Both female union, BSP thread BTU - Branch tee union BU - Bulkhead union C - Cap CIBEU - Clean elbow union (both (double) o-ring) CIBUC - Clean union connector (both (double) o-ring) CIMCBT - Clean male connector, BSPT thread CIMCF - Clean male connector, threaded cap CIMCW - Clean male connector, BSW thread CP - Half Cartridge (Injection process) CR - Cross CU - Half Cartridge (Ultrasonic wave process) DA - Drain adapter DEU - Dispensing elbow union EL - Enlarger EU - Elbow union FA - Femal adapter, NPTF-Standard type FAB - Female adapter , BSPP Thread FAN - Female adapter , NH Thread FAU - Female adapter, UNS thread FAUF - Female adapter, UNF thread FAUN - Female adapter, UN thread FC - Filter connector FR - Fitting reducer HA - Hub adapter KFA - Kitchen faucet adapter MC - Male connector MCB - Male connector, BSP thread MCBB - Male connector with Big O-ring MCBT - Male connector, BSPT thread MCF - Male connector, MFL thread (threaded cap) MCW - Male connector, BSW thread ME - Male elbow MTU - Male tee union (NPTF thread) MTUR - Male tee union OC - Offset connector PBBC - Power barb connector PBEU - Power elbow union (both (double) o-ring) PBUC - Power union connector (both (dobule) o-ring) PL - Plug PMCBT - Power male connector, BSPT thread PMCF - Power male connector, threaded cap PMCW - Power male connector, BSW thread PSEU - Power elbow union (single o-ring) PSFBU - Power flow bend union (single o-ring) PSUC - Power union connector (single o-ring) RD - Reducer SA - Stem adapter SAB - Stem adapter, BSP thread SABT - Stem adapter, BSPT thread SAW - Stem adapter, BSW thread SEU - Swivel elbow union STU - Stackable tee union SUC - Swivel union connector SVA - Stop valve adapter TBC - Tube barb connector TEB - Tube elbow barb connector TES - Tube end stop TEU - Tube elbow union THWD - Three-way divider TTU - Tee union (4 holes) TU - Tee union (3 holes) TWD - Two-way divider UB - U-Bend UC - Union connector [3] [XX] represents the outer diameter of the inlet in mm, where XX may be 04 (4 mm) - 28 (28 mm). [YY] represemts the outer diamter of outlet in mm for fittings without threads, where YY may be 04 (4 mm) - 28 (28 mm). [YY] represent the outer diameter of the threded outlet in inches for threaded fittings, where YY may be 02 (1/8"), 04 (1/4"), 06 (3/8"), 07 (1/2"), 08 (5/8"), 09 (3/4"), 11 (1"), 7/16 (7/16"), or 9/16 (9/16"). [4] Fitting configuration abbreviations: BBC - Barb connector BU - Bulkhead union C - Cap CR - Cross DA - Drain adapter EL - Enlarger EU - Elbow union FA - Female adapter, NPTF standard type FAB - Female adapter, BSPP Thread FAN - Female adapter, NH Thread FAU - Female adapter, UNS thread FAUF - Female adapter, UNF thread FAUN - Female adapter, UN thread FWC - Four way connector HA - Hub adapter MC - Male connector MCB - Male connector, BSP thread ME - Male elbow OC - Offset connector PBEU - Power elbow union (both (double) o-ring) PBUC - Power union connector (both (double) o-ring) PL - Plug PMCF - Power male connector, threaded cap PMCW - Power male connector, BSW thread PSUC - Power union connector (single o-ring) RD - Reducer SA - Stem adapter SAB - Stem adapter, BSP thread SEU - Swivel elbow union SSA - Stem-to-Stem adapter SUC - Swivel union connector TBC - Tube barb connector TC - Tank connector TES - Tube end stop THWD - Three-way divider TU - Tee union TWD - Two-way divider UB - U-Bend UC - Union connector [5] 15 mm x 1/2" - 22 mm x 3/4" [6] 15 mm x 1/2" - 18 mm x 1/2" [7] 15 mm x 3/8" - 15 mm x 1/2" [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. [10] [XX] represents the inlet diameter size in inches, where [XX] may be any of the following: 04 (1/4"), 05 (5/16"), 06 (3/8"), 07 (1/2"), 047 (1/4"), or 067 (3/8"). For fittings without threads, [YY] represents the outlet diameter size in inches, where [YY] may be any of the following: 04 (1/4"), 05 (5/16"), 06 (3/8"), or 07 (1/2"). For fittings with threads, [YY] represents the threaded outlet size in inches, where [YY] may be any of the following: 02 (1/8"), 03 (3/16"), 04 (1/4"), 05 (5/16"), 06 (3/8"), 07 (1/2"), or 16C (7/16" - 24"). |
||||
Fittings, Non-Repeating[1] [2] [G] |
||||
ACP [WW] M | 6 mm – 12 mm | D. HOT | MLTPL | |
ACP [XX] | 1/4" – 1/2" | D. HOT | MLTPL | |
ACU [WW] M | 4 mm – 5 mm | D. HOT | MLTPL | |
ACU [XX] | 5/32" – 3/16" | D. HOT | MLTPL | |
[1] [XX] represents the inlet diameter size in inches, where [XX] may be any of the following: 01 (5/32") , 03 (3/16"), 04 (1/4"), 05 (5/16"), 06 (3/8"), or 07 (1/2"). For fittings without threads, [YY] represents the outlet diameter size in inches, where [YY] may be any of the following: 01 (5/32"), 03 (3/16"), 04 (1/4"), 05 (5/16"), 06 (3/8"), 07 (1/2"), 08 (5/8"), 09 (3/4"), 10 (7/8"), or 11 (1"). [WW] represents the outer diameter of the inlet in mm, 04 (4 mm) - 12 (12 mm). For fittings with threads, [YY] represents the threaded outlet size in inches, where [YY] may be any of the following: 01 (5/32"), 02 (1/8"), 03 (3/16"), 04 (1/4"), 05 (5/16"), 06 (3/8"), 07 (1/2"), 08 (5/8") , 09 (3/4"), 10 (7/8"), 11 (1"), 7/16 (7/16"), or 9/16 (9/16"). [Z] represents the color of the fitting body, where 'W' represents white and the absence of a letter represents gray. 'SW' represents a silicone o-ring with a white fitting body. For Half Cartridge, ACU [XX], ACP[XX], ACU[WW]M, and ACP[WW]M fittings are approved for a maximum use of 1 unit per liter. ALC [XX] and ALC [YY]M are locking clips and used with fitting products and tubing products. The locking clips are non-wetted. The [XX] refers to the outer diameter of the tube: 03(3/16"), 04(1/4"), 05(5/16"), 06(3/8"), 07(1/2"). 08(5/8"), 10(7/8") and the [YY] refers to the outer diameter of the tube: 05(5mm), 06(6mm), 08(8mm), 10(10mm), 12(12mm), 15(15mm), 16(16mm), 18(18mm), 22(22mm), 28(28mm). [2] Fitting configuration abbreviations: BBC - Barb connector BFU - Both female union, BSP thread BTU - Branch tee union BU - Bulkhead union C - Cap CIBEU - Clean elbow union (both (double) o-ring) CIBUC - Clean union connector (both (double) o-ring) CIMCBT - Clean male connector, BSPT thread CIMCF - Clean male connector, threaded cap CIMCW - Clean male connector, BSW thread CP - Half Cartridge (Injection process) CR - Cross CU - Half Cartridge (Ultrasonic wave process) DA - Drain adapter DEU - Dispensing elbow union EL - Enlarger EU - Elbow union FA - Femal adapter, NPTF-Standard type FAB - Female adapter , BSPP Thread FAN - Female adapter , NH Thread FAU - Female adapter, UNS thread FAUF - Female adapter, UNF thread FAUN - Female adapter, UN thread FC - Filter connector FR - Fitting reducer HA - Hub adapter KFA - Kitchen faucet adapter MC - Male connector MCB - Male connector, BSP thread MCBB - Male connector with Big O-ring MCBT - Male connector, BSPT thread MCF - Male connector, MFL thread (threaded cap) MCW - Male connector, BSW thread ME - Male elbow MTU - Male tee union (NPTF thread) MTUR - Male tee union OC - Offset connector PBBC - Power barb connector PBEU - Power elbow union (both (double) o-ring) PBUC - Power union connector (both (dobule) o-ring) PL - Plug PMCBT - Power male connector, BSPT thread PMCF - Power male connector, threaded cap PMCW - Power male connector, BSW thread PSEU - Power elbow union (single o-ring) PSFBU - Power flow bend union (single o-ring) PSUC - Power union connector (single o-ring) RD - Reducer SA - Stem adapter SAB - Stem adapter, BSP thread SABT - Stem adapter, BSPT thread SAW - Stem adapter, BSW thread SEU - Swivel elbow union STU - Stackable tee union SUC - Swivel union connector SVA - Stop valve adapter TBC - Tube barb connector TEB - Tube elbow barb connector TES - Tube end stop TEU - Tube elbow union THWD - Three-way divider TTU - Tee union (4 holes) TU - Tee union (3 holes) TWD - Two-way divider UB - U-Bend UC - Union connector [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||
Tubing/Hose [G] |
||||
DPE-OD-CO-RL[8] | 4 mm - 15 mm | C. HOT | PE | |
DPE-RT04[9] | 1/4" | C. HOT | PERT | |
DPE-RT05[9] | 5/16" | C. HOT | PERT | |
DPE-RT06[9] | 3/8" | C. HOT | PERT | |
DPE-RT07[9] | 1/2" | C. HOT | PERT | |
[8] DPE - Trade name OD - Outer diameter 01 - 5/32" 03 - 3/16" 04 - 1/4" 05 - 5/16" 06 - 3/8" 07 - 1/2" 04M - 4mm 06M - 6mm 08M - 8mm 10M - 10mm 12M - 12mm 15M - 15mm CO - Color BK - Black BL - Blue GN - Green GR - Gray IBK - Black NA - Natural OR - Orange RE - Red WT - White YE - Yellow RL - Reel length (meters) 0100 - 100 m 0150 - 150 m 0200 - 200 m 0300 - 300 m 0400 - 400 m 0500 - 500 m 1000 - 1000 m 1500 - 1500 m Certified for the maximum length for each diameter: Outer diameter: Inner diameter: Length: 5/16" .187" 7.8 m 3/8" 1/4" 5.8 m 1/2" 3/8" 3.9 m 8mm 6mm 6.2 m 10mm 7mm 5.3 m 12mm 9mm 4.1 m 15mm 11.5mm 3.2 m [9] Certified for blue or white tubing. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 227
Processing time was 1 seconds