NSF Product and Service Listings

These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=11370&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
FIP - Formatura Iniezione Polimeri S.p.A. 
Pian di Parata
I-16015 Casella Genova 
Italy 
39 010 96211
Visit this company's website


Facility : Genova, Italy

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Switches/Sensors[1] [G]
FLS F3.05.YZ-FLOW SWITCH 1/2" - 24" CLD 23 MLTPL
FLS F3.0S.T.YZ-PADDLEWHEEL SENSOR 1/2" - 24" CLD 23 MLTPL
FLS F6.61.YZ-HOT-TAP MAGMETER 2" - 36" CLD 23 MLTPL
FLS F6.6X.YZ MAGMETER 1/2: - 24" CLD 23 MLTPL

[1] S  - mounting feature
         0 - standard paddlewheel sensor
         1 - paddlewheel sensor for compact mounting
    T  - Technology of electronic transmission
         H - hall effect
         C - coil
         P - push-pull
    X  - Flow functionality
         0 - bidirectional standard sized FLS F3.0 model
         3 - mono-directional
    YZ - Number indication materials (sensor & gasket)
         09, 10, 11, 12, 38, 40 - mono and bi directional magmeters
         01 - hot tap magmeter and high pressure paddlewheel sensor
         01 thru 24 - paddlewheel sensor
         01 thru 12 - flow switch, paddlewheel transmitter and paddlewheel sensor for
    compact mounting
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Transmitters/Gauges[1] [G]
FLS F6.30.YZ-PADDLEWHEEL TRANSMITTER 1/2" - 24" CLD 23 MLTPL

[1] S  - mounting feature
         0 - standard paddlewheel sensor
         1 - paddlewheel sensor for compact mounting
    T  - Technology of electronic transmission
         H - hall effect
         C - coil
         P - push-pull
    X  - Flow functionality
         0 - bidirectional standard sized FLS F3.0 model
         3 - mono-directional
    YZ - Number indication materials (sensor & gasket)
         09, 10, 11, 12, 38, 40 - mono and bi directional magmeters
         01 - hot tap magmeter and high pressure paddlewheel sensor
         01 thru 24 - paddlewheel sensor
         01 thru 12 - flow switch, paddlewheel transmitter and paddlewheel sensor for
    compact mounting
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Valves [G]
Dual Block VKR(X)(Y)(Z)[2] 3/8" - 2" C. HOT MLTPL
Dual Block VKR(X)(Y)(Z)[3] 3/8" - 2" CLD 23 MLTPL
DualBlock LKD(X)(Y)(Z)[3] 3/8" - 2" CLD 23 MLTPL
DualBlock LKD(X)(Y)(Z)[2] 3/8" - 2" C. HOT MLTPL
DualBlock TKD(X)(Y)(Z)[2] 3/8" - 2" C. HOT MLTPL
DualBlock TKD(X)(Y)(Z)[3] 3/8" - 2" CLD 23 MLTPL
DualBlock VKD(X)(Y)(Z)[2] 3/8" - 4" C. HOT MLTPL
DualBlock VKD(X)(Y)(Z)[3] 3/8" - 4" CLD 23 MLTPL
DualBlock VKD(X)(Y)(Z)/SHX[3] 3/8" - 2" CLD 23 MLTPL
DualBlock VKD(X)(Y)(Z)/SHX[2] 3/8" - 2" C. HOT MLTPL
Easyfit SXE(X)(Y)(Z)[3] 3/8" - 4" CLD 23 MLTPL
Easyfit SXE(X)(Y)(Z)[2] 3/8" - 4" C. HOT MLTPL
Easyfit VEE(X)(Y)(Z)[3] 3/8" - 4" CLD 23 MLTPL
Easyfit VXE(X)(Y)(Z)[2] 3/8" - 4" C. HOT MLTPL
Easyfit VXE(X)(Y)(Z)[3] 3/8" - 4" CLD 23 MLTPL
FE (X)(T)(Y) (Z) (W)[4] 40 mm - 400 mm CLD 23 MLTPL
FK (X)(T)(Y) (Z) (W)[5] 40 mm - 400 mm CLD 23 MLTPL
FK (X)(T)(Y) (Z) (W)[6] 40 mm - 400 mm C. HOT MLTPL
FX (X)(T)(Y) (Z) (W)[7] 40 mm - 400 mm CLD 23 MLTPL
FX (X)(T)(Y) (Z) (W)[7] 40 mm - 400 mm C. HOT MLTPL
VE(X)(Y)(Z)[3] 2 1/2" - 4" CLD 23 MLTPL
VX(X)(Y)(Z)[2] 2 1/2" - 4" C. HOT MLTPL
VX(X)(Y)(Z)[3] 2 1/2" - 4" CLD 23 MLTPL

[2] Certified for equivalent metric sizes.
    DualBlock TKD,LKD(X)(Y)(Z)
    X - End connection type
        IC AC NC FC IM DM FM OM OAM BM
    Y - Size
        Imperial (inches)
        012 034 038 100 112 114 200
        Metric (mm)
        016 020 025 032 040 050 063
    Z - O-ring type
        E - EPDM o-ring F - FPM o-ring
    DualBlock VKD(X)(Y)(Z)
    X - End Connection Type
        IC AC NC DC OC OAC FC IM DM FM OM OAM BM
    Y - Size
        Imperial (inches)
        012 034 038 100 112 114 200 212 300 400
        Metric (mm)
        016 020 025 032 040 050 063 075 090 110
    Z - O-ring type
        E - EPDM o-ring F - FPM o-ring
    /SHX - non-wetted stainless steel fasteners (optional)
    Easyfit VXE(X)(Y)(Z)
    X - End Connection Type
        IC AC NC FC
    Y - Size
        Imperial (inches)
        012 034 038 100 112 114 200 212 300 400
        Metric (mm)
        016 020 025 032 040 050 063 075 090 110
    Z - O-ring type
        E - EPDM o-ring F - FPM o-ring
    VX(X)(Y)(Z)
    X - End Connection Type
        IC AC NC FC
    Y - Size
        Imperial (inches)
        212 300 400
        Metric (mm)
        075 090 110
    Z - O-ring type
        E - EPDM o-ring F - FPM o-ring
    Easyfit SXE(X)(Y)(Z)
    X - End Connection Type
        IC, AC, NC, FC
    Y - Size 
        Imperial (inches)
        038 012 034 100 114 112 200 212 300 400
        Metric (mm)
        016 020 025 032 040 050 063 075 090 110
    Z - O-ring type
        E - EPDM F - FPM
    DualBlock VKR(X)(Y)(Z)
    X - End connection type
        IC DC LC FC AC NC JC GC OC OAC IM DM FM OM OAM BM
    Y - Size
        Imperial (inches)
        038 012 034 100 114 112 200
        Metric (mm)
        016 020 025 032 040 050 063
    Z - O-ring type
        E - EPDM o-ring F - FPM o-ring
    
    
[3] Certified for equivalent metric sizes.
    VE, VX
    X - End connection type
        IV FV LV AV NV JV GV
    Y - Size
        Imperial (inches)
        212 300 400
        Metric (mm)
        075 090 110 
    Z - O-ring type
        E - EPDM F - FPM
    VEE
    X - End Connection Type
        IV FV LV AV NV JV GV
    Y - Size 
        Imperial (inches)
        012 034 038 100 114 112 200 212 300 400
        Metric (mm)
        016 020 025 032 040 050 063 075 090 110
    Z - O-ring type
        E - EPDM F - FPM
    VKD
    X - End Connection Type
        IV FV LV AV NV JV GV/SHX IM DM FM OM OAM BM/SHX
    Y - Size
        Imperial (inches)
        038 012 034 100 114 112 200 212 300 400
        Metric (mm)
        016 020 025 032 040 050 063 075 090 110 
    Z - O-ring type
        E - EPDM F - FPM
    VXE
    X - End Connection Type
        IV DV FV LV AV NV JV GV
    Y - Size
        Imperial (inches)
        038 012 034 100 114 112 200 212 300 400
        Metric (mm)
        016 020 025 032 040 050 063 075 090 110
    Z - O-ring type
        E - EPDM F - FPM
    TKD, LKD
    X - End Connection Type
        AV DV FV GV IV JV LV NV IM DM FM BM OM OAM
    Y - Size
        Imperial (inches)
        038 012 034 100 114 112 200
        Metric (mm)
        016 020 025 032 040 050 063
    Z - O-ring type
        E - EPDM F - FPM
    SXE
    X - End Connection Type
        AV DV FV GV IV JV LV NV
    Y - Size Imperial (inches)
        038 012 034 100 114 112 200 212 300 400
        Metric (mm)
        016 020 025 032 040 050 063 075 090 110
    Z - O-ring type
        E - EPDM F - FPM
    VKR
    X - End connection type
        IV DV LV FV AV NV JV GV OV OAV IM DM FM OM OAM BM
    Y - Size
        Imperial (inches)
        038 012 034 100 114 112 200
        Metric (mm)
        016 020 025 032 040 050 063
    Z - O-ring type
        E - EPDM F - FPM
[4] FE (X)(T)(Y) (Z) (W)   
    X  - End connection type
    O  - Flanged ISO type
    OA - Flanged ANSI type
    T  - Disc Material PVC-U
    W  - Actuation type
         FM, LM, RM,CE, CP
    Y  - Size
         Metric (mm)
         050 063 075 090 110 140 160 225 280 315 355 400
         Imperial (inches)
         112, 200, 212 300 400 500 600 800 810 812 814 816
    Z  - Gasket type
    E  - EPDM
[5] FK (X)(T)(Y) (Z) (W)
    X   - End connection type
    O   - Flanged ISO type
    OA  - Flanged ANSI type
    OL  - Flanged lug ISO type
    OAL - Flanged lug ANSI type
    T   - Disc material PVC-U, PVC-C and PP-H
    W   - Actuation type
          FM, LM, RM, CE, CP
    Y   - Size
          Metric (mm)
          050 063 075 090 110 140 160 225 280 315 355 400
          Imperial (inches)
          112 200 212 300 400 500 600 800 810 812 814 816
    Z   - Gasket type
    E   - EPDM
[6] FK (X)(T)(Y) (Z) (W)
    X   - End connection type
    O   - Flanged ISO type
    OA  - Flanged ANSI type
    OL  - Flanged lug ISO type
    OAL - Flanged lug ANSI type
    T   - Disc Material PVC-C and PP-H
    W   - Actuation type
          FM, LM, RM,CE, CP
    Y   - Size
          Metric (mm)
          050 063 075 090 110 140 160 225 280 315 355 400
          Imperial (inches)
          112, 200, 212 300 400 500 600 800 810 812 814 816
    Z   - Gasket type
    E   - EPDM
[7] FX (X)(T)(Y) (Z) (W)
    X   - End connection type
    O   - Flanged ISO type
    OA  - Flanged ANSI type
    OL  - Flanged lug ISO type
    OAL - Flanged lug ANSI type
    W   - Actuation type
          FM, LM, RM,CE, CP
    Y   - Size
          Metric
          (mm) 050 063 075 090 110 140 160 225 280 315 355 400
          Imperial (inches)
          112,200,212 300 400 500 600 800 810 812 814 816
    Z   - Gasket type
    E   - EPDM
    T   - Disc Material PP-H
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Number of matching Manufacturers is 1
Number of matching Products is 28
Processing time was 0 seconds