NSF Product and Service Listings
These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=15490&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Akzo Nobel Coatings Inc. | |
P.O. Box 91629 | |
Cleveland, OH 44101 | |
United States | |
216-750-6475 |
Facility : Warsaw, IN
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Coatings - Pipe[1] |
||||
HA000Q INT 100 White Primer | >= 6" | CLD 23 | PEC | |
HL001QF Interpon 100 Duracoat Grey | >= 6" | CLD 23 | PEC | |
HM001QF INT100 16452 Tarsco Tan | >= 6" | CLD 23 | PEC | |
[1] Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 10 Final Cure Time and Temperature: 15 minutes at 350°F |
||||
Coatings - Tank[1] |
||||
HA000Q INT 100 White Primer | >= 4000 gal. | CLD 23 | PEC | |
HL001QF Interpon 100 Duracoat Grey | >= 4000 gal. | CLD 23 | PEC | |
HM001QF INT100 16452 Tarsco Tan | >= 4000 gal. | CLD 23 | PEC | |
[1] Number of Coats: 1-2 Maximum Field Use Dry Film Thickness (in mils): 10 Final Cure Time and Temperature: 15 minutes at 350°F |
Facility : Nashville, TN
Protective (Barrier) Materials
Water | Water | |||
Water Contact | Contact | Contact | ||
Trade Designation | Size Restriction | Temp | Material | |
Coatings - Fittings |
||||
HAF09R Resicoat R4-ES White[1] | >= 1" | D. HOT | PEC | |
HEF22R Resicoat R4-ES Yellow[1] | >= 1" | D. HOT | PEC | |
HGC17R Resicoat R4-FB Red[2] | >= 1" | D. HOT | PEC | |
HGF17R Resicoat R4-ES Rust[3] | >= 1" | D. HOT | PEC | |
HJ606R Resicoat R4-ES Blue[1] | >= 1" | D. HOT | PEC | |
HJC08R Resicoat R4-FB Blue[4] | >= 1" | D. HOT | PEC | |
HJF10R Resicoat R4-ES RAL5017 Blue[1] | >= 1" | D. HOT | PEC | |
HJF14R Resicoat R4-ES RAL5015 Blue[1] | >= 1" | D. HOT | PEC | |
HJF24R Resicoat R4-ES Blue[5] | >= 1" | D. HOT | PEC | |
HJF42R Resicoat R4-ES Blue[1] | >= 1" | D. HOT | PEC | |
HJF4BR Resicoat R4-ES Blue[1] | >= 1" | D. HOT | PEC | |
HJF99R Resicoat R4-ES RAL5009 Blue[1] | >= 1" | D. HOT | PEC | |
HKF47R Resicoat R4-ES Green[6] | >= 1" | D. HOT | PEC | |
HNF24R Resicoat R4-ES Black[3] | >= 1" | D. HOT | PEC | |
Resicoat R4-ES HGF38R[7] | >= 1" | D. HOT | PEC | |
[1] Colors: Blue, white, yellow Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Maximum Thinner: None Final Cure: 20 minutes at 428°F [2] Colors: Red Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Final Cure Time and Temperature: 20 minutes at 220°C Special Comments: Preheat at 200°C - 230°C [3] Colors: Black, rust Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Final Cure Time and Temperature: 20 minutes at 428°F [4] Colors: Blue Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Recoat Cure Time and Temperature: 20 minutes at 220°C Special Comments: Pre-heat at 200°C - 230°C [5] Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Final Cure Time and Temperature: 20 minutes at 428°F Special Comments: Self curing on 8 mm or heavier steel at 392°F - 428°F metal temperature. [6] Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 35 Final Cure Time and Temperature: 455°F metal temperature and post cured for 10 minutes at 455°F Special Comments: Metal plates are pre-heated to 455°F and sprayed while hot. Plates are then post cured for 10 minutes at 455°F. [7] Colors: Red brown Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Maximum Thinner: None Final Cure Time and Temperature: 20 minutes at 428ºF |
||||
Coatings - Pipe |
||||
AD139QF Interpon 100 Tank Tan[8] | >= 6" | CLD 23 | PEC | |
HA000Q Interpon 100 White Primer[9] | >= 1/2" | CLD 23 | PEC | |
HKF47R Resicoat R4-ES Green[6] | >= 1/2" | D. HOT | PEC | |
HL001QF Interpon 100 Duracoat Grey[9] | >= 1/2" | CLD 23 | PEC | |
[6] Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 35 Final Cure Time and Temperature: 455°F metal temperature and post cured for 10 minutes at 455°F Special Comments: Metal plates are pre-heated to 455°F and sprayed while hot. Plates are then post cured for 10 minutes at 455°F. [8] Number of Coats: 1 Maximum Field Use Dry Thickness: 10 mils Final Cure Time/Temperature: 10 minutes at 400°F [9] Colors: White, Grey Number of Coats: 1 Maximum field use dry film thickness (in mils): 10 Final cure time and temperature: 15 minutes at 350° F |
||||
Coatings - Tank |
||||
AD139QF Interpon 100 Tank Tan[8] | >= 4000 gal. | CLD 23 | PEC | |
HA000Q Interpon 100 White Primer[9] | >= 4000 gal. | CLD 23 | PEC | |
HL001QF Interpon 100 Duracoat Grey[9] | >= 4000 gal. | CLD 23 | PEC | |
[8] Number of Coats: 1 Maximum Field Use Dry Thickness: 10 mils Final Cure Time/Temperature: 10 minutes at 400°F [9] Colors: White, Grey Number of Coats: 1 Maximum field use dry film thickness (in mils): 10 Final cure time and temperature: 15 minutes at 350° F |
||||
Coatings - Valve |
||||
HAF09R Resicoat R4-ES White[1] | >= 1" | D. HOT | PEC | |
HEF22R Resicoat R4-ES Yellow[1] | >= 1" | D. HOT | PEC | |
HGC17R Resicoat R4-FB Red[2] | >= 1" | D. HOT | PEC | |
HGF17R Resicoat R4-ES Rust[3] | >= 1" | D. HOT | PEC | |
HJ606R Resicoat R4-ES Blue[1] | >= 1" | D. HOT | PEC | |
HJC08R Resicoat R4-FB Blue[4] | >= 1" | D. HOT | PEC | |
HJF10R Resicoat R4-ES RAL5017 Blue[1] | >= 1" | D. HOT | PEC | |
HJF14R Resicoat R4-ES RAL5015 Blue[1] | >= 1" | D. HOT | PEC | |
HJF24R Resicoat R4-ES Blue[5] | >= 1" | D. HOT | PEC | |
HJF42R Resicoat R4-ES Blue[1] | >= 1" | D. HOT | PEC | |
HJF4BR Resicoat R4-ES Blue[1] | >= 1" | D. HOT | PEC | |
HJF99R Resicoat R4-ES RAL5009 Blue[1] | >= 1" | D. HOT | PEC | |
HKF47R Resicoat R4-ES Green[6] | >= 1" | D. HOT | PEC | |
HNF24R Resicoat R4-ES Black[3] | >= 1" | D. HOT | PEC | |
Resicoat R4-ES HGF38R[7] | >= 1" | D. HOT | PEC | |
[1] Colors: Blue, white, yellow Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Maximum Thinner: None Final Cure: 20 minutes at 428°F [2] Colors: Red Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Final Cure Time and Temperature: 20 minutes at 220°C Special Comments: Preheat at 200°C - 230°C [3] Colors: Black, rust Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Final Cure Time and Temperature: 20 minutes at 428°F [4] Colors: Blue Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Recoat Cure Time and Temperature: 20 minutes at 220°C Special Comments: Pre-heat at 200°C - 230°C [5] Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Final Cure Time and Temperature: 20 minutes at 428°F Special Comments: Self curing on 8 mm or heavier steel at 392°F - 428°F metal temperature. [6] Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 35 Final Cure Time and Temperature: 455°F metal temperature and post cured for 10 minutes at 455°F Special Comments: Metal plates are pre-heated to 455°F and sprayed while hot. Plates are then post cured for 10 minutes at 455°F. [7] Colors: Red brown Number of Coats: 1 Maximum Field Use Dry Film Thickness (in mils): 20 Maximum Thinner: None Final Cure Time and Temperature: 20 minutes at 428ºF |
Number of matching Manufacturers is 1
Number of matching Products is 43
Processing time was 0 seconds