NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Enecon Corporation 
6 Platinum Court 
Medford, NY 11763 
United States 
800-436-3266 
516-349-0022


Facility : Medford, NY

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings
CHEMCLAD SC[1] [2] >= 6" CLD 23 EPOXY

[1] Colors: Gray, haze gray, white
    Number of Coats: 2 - 4
    Maximum Field Use Dry Film Thickness (in mils): 28 (7 mils per coat)
    Recoat Cure Time and Temperature: 24 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Mix ratio of Base:Activator is 3.29:1 by weight.
[2] Certification does not include Chemclad P4C.

Coatings - Pipe
CHEMCLAD SC[1] [2] >= 12" CLD 23 EPOXY

[1] Colors: Gray, haze gray, white
    Number of Coats: 2 - 4
    Maximum Field Use Dry Film Thickness (in mils): 28 (7 mils per coat)
    Recoat Cure Time and Temperature: 24 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Mix ratio of Base:Activator is 3.29:1 by weight.
[2] Certification does not include Chemclad P4C.

Coatings - Pump
CHEMCLAD SC[1] [2] >= 4" CLD 23 EPOXY

[1] Colors: Gray, haze gray, white
    Number of Coats: 2 - 4
    Maximum Field Use Dry Film Thickness (in mils): 28 (7 mils per coat)
    Recoat Cure Time and Temperature: 24 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Mix ratio of Base:Activator is 3.29:1 by weight.
[2] Certification does not include Chemclad P4C.

Coatings - Tank
CHEMCLAD SC[1] [2] >= 25 gal. CLD 23 EPOXY

[1] Colors: Gray, haze gray, white
    Number of Coats: 2 - 4
    Maximum Field Use Dry Film Thickness (in mils): 28 (7 mils per coat)
    Recoat Cure Time and Temperature: 24 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Mix ratio of Base:Activator is 3.29:1 by weight.
[2] Certification does not include Chemclad P4C.

Coatings - Valve
CHEMCLAD SC[1] [2] >= 6" CLD 23 EPOXY

[1] Colors: Gray, haze gray, white
    Number of Coats: 2 - 4
    Maximum Field Use Dry Film Thickness (in mils): 28 (7 mils per coat)
    Recoat Cure Time and Temperature: 24 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Mix ratio of Base:Activator is 3.29:1 by weight.
[2] Certification does not include Chemclad P4C.