NSF Product and Service Listings

These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=31270&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Flowserve Corporation 
5215 North O'Connor Boulevard
Suite 2300 
Irving, TX 75039 
United States 
972-443-6500


Facility : Taneytown, MD

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Pumps [G]
VPC-(v)(w)(x)(y)-(z)[2] [3] 6" - 52" CLD 23 MLTPL
VTP-(v)(w)(x)(y)-(z)[2] [3] 6" - 52" CLD 23 MLTPL
[W]LNEC[X] BB1 Axially Split, Single Stage Pump[1] 125 mm - 750 mm CLD 23 MLTPL
[W]LNE[X] BB1 Axially Split, Single Stage Pump[1] 125 mm - 750 mm CLD 23 MLTPL
[W]LNNA[X] BB1 Axially Split, Single Stage Pump[1] 200 mm - 1000 mm CLD 23 MLTPL
[W]LNNC[X] BB1 Axially Split, Single Stage Pump[1] 300 mm - 700 mm CLD 23 MLTPL
[W]LNN[X] BB1 Axially Split, Single Stage Pump[1] 200 mm - 1000 mm CLD 23 MLTPL
[Y]LN[Z] BB1 Axially Split, Single Stage Pump[1] 6" - 30" CLD 23 MLTPL

[1] [W] Represents the nominal discharge diameter in mm:
        LNN and LNNA pumps
        200, 250, 300, 350, 400, 500, 600, 700, 800, 900,or    1000
        LNE and LNEC pumps
        125, 200, 250, 300, 250, 400, 500, 600, 750
        LNNC pumps
        300, 600, or 700
    [X] Represents the nominal impeller diameter in mm:
        LNN and LNNA pumps:
        300, 325, 375, 400, 450, 475, 500, 525, 575, 600, 625, 650, 725, 750, 800, 875, 900,
         925, 950, 975, 1000, 1075, 1150, 1200, 1225, or 1250
        LNE and LNEC Pumps
        450, 550, 575, 675, 750, 850, 900, or 1050
        LNNC pumps
        475, 950, 975, or 1225
    [Y] Represents the nominal discharge diameter in inches and may be 6, 8, 10, 12, 14, 16,
         20, 24, or 30
    [Z] Represents the nominal impeller diameter in inches and may be 10, 12, 14, 18, 19,
    20,     23, 24, 26, 28, 29, 32, 40, or 41
    Only pumps with coated interiors are Certified.
[2] [v][w][x][y]-[z]
    v - Size of pump in inches (6-52)
    w - Impeller type (blank, C, E, S)
    x - Pump model (B, C, D, G, H, J, K , KX, L, M, N, P, Q, TM, X)
    y - Impeller design (F, H, L, M, X, Y, Z)
    z - Number of stages
[3] Certified for a minimum daily flow of 375,000 L.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Submersible Motors
Flowserve (Byron Jackson) Submersible Motors (Mechanical Sealed)[4] [G] 8" - 21" CLD 23 MLTPL

[4] Certified for a minimum daily flow of 150,000 L.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Submersible Pump - Pump/Motor Units [G]
SUBM - Submersible Pump [v][w][x][y]-[z][5] [6] 5" - 52" CLD 23 MLTPL

[5] Certified for a minimum daily flow of 150,000 L.  Pumps with bronze cases are not
    Certified.
[6] [v][w][x][y]-[z]
    v - Size of pump in inches (5"-52")
    w - Impeller type (blank, C, E)
    x - Pump model (B, G, H, HQ, J, K, KX, L, LQ, M, MQ, N, P, Q, TM)
    y - Impeller design (blank, F, H, L, M, X, Y, Z)
    z - Number of stages
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Submersible Pump Cable [G]
Flowserve (Byron Jackson) Submersible Cables [4] [7] CLD 23 MLTPL

[4] Certified for a minimum daily flow of 150,000 L.
[7] 600 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG, 250 MCM, 350 MCM, 500
    MCM
    5000 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



Facility : Hastings, NE

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Pumps[1] [2] [3] [G]
VPC-(v)(w)(x)(y)-(z) 6" - 52" CLD 23 MLTPL
VTP-(v)(w)(x)(y)-(z) 6" - 52" CLD 23 MLTPL

[1] [v][w][x][y]-[z]
    v - Size of pump in inches (6-52)
    w - Impeller type (blank, C, E, S)
    x - Pump model (B, C, D, G, H, J, K , KX, L, M, N, P, Q, TM, X)
    y - Impeller design (F, H, L, M, X, Y, Z)
    z - Number of stages
[2] Certified for a minimum daily flow of 375,000 L.
[3] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Submersible Pumps - Pump/Motor Units[3] [4] [5] [G]
SUBM - Submersible Pump [v][w][x][y]- [z] 5" - 52" CLD 23 MLTPL
Flowserve (Byron Jackson) Submersible Cables[7] [8] [6] CLD 23 MLTPL

[3] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[4] Certified for a minimum daily flow of 150,000 L. Pumps with bronze cases are not
    Certified.
[5] [v][w][x][y]-[z]
       v - Size of pump in inches (5"-52")
       w - Impeller type (blank, C, E)
       x - Pump model (B, G, H, HQ, J, K, KX, L, LQ, M, MQ, N, P, Q, TM)
       y - Impeller design (blank, F, H, L, M, X, Y, Z)
       z - Number of stages 
[6] Certified for a minimum daily flow of 150,000 L.
[7] 600 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG, 250 MCM, 350 MCM, 500
    MCM
[8] 5000 Volt: 1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 3/0 AWG, 4 AWG, 4/0 AWG
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



Facility : Chesapeake, VA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Pumps[1] [2] [G]
Chesapeake Mark 3 ANSI Overhung Pumps, [A]K[B]x[C][D]-[E][F][G][3] 1 1/2" x 1"-10" x 8" CLD 23 MLTPL
[X]LR[Y][S] BB1 Axially Split, Single Stage Pump[4] 2 1/2" - 12" CLD 23 MLTPL

[1] Certified for water end uses only. Certification not requested for chemical service.
[2] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[3] [A] Bearing frame size (group size in Flowserve terms)
        1, 2, or 3
    [B] Suction flange size (NB ANSI flange)
        1.5, 2, 3, 4, 6, 8, or 10
    [C] Discharge flange size (NB ANSI flange)
        1, 1.5, 2, 3, 4, 6, or 8
    [D] Special versions of Mark 3 products
        Blank or no letter - standard pump
        LF - Lo-Flo
    [E] Maximum size of impeller (inch nominal)
        4, 62 (6.2), 82 (8.2), 10, 13, 14, 16, or 17
    [F] Revised hydraulic marker
        () - Blank signifies no change to the original hydraulics of Mark 3 product
        A  - Significant hydraulic change
        H  - High Flow hydraulic design
        HH - High Head hydraulic design
    [G] Impeller Design
        RV - Reverse Vane impeller design
        OP - Open impeller design
[4] [S] Is an optional designation that identifies tounge and groove casing 
        rings fitted.  Only pumps with coated interiors are Certified.
    [X] Refers to the nominal discharge diameter in inches and may be 2.5, 
        3, 4, 5, 6, 8, 10 or 12.
    [Y] Refers to the nominal impeller diameter in inches and may be 9, 10, 
        11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 23, or 25.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Number of matching Manufacturers is 1
Number of matching Products is 17
Processing time was 0 seconds