NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Veolia Water Technologies & Solutions | |
3600 Horizon Boulevard | |
Trevose, PA 19053 | |
United States | |
888-898-6766 | |
215-942-3534 |
Facility : Westborough, MA
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Miscellaneous Process Devices/Components [G] |
||||
AR204 | [1] | CLD 23 | MLTPL | |
AR404 Coated Electrode | [2] | CLD 23 | MLTPL | |
AR908 | [1] | CLD 23 | MLTPL | |
CR64 | [1] | CLD 23 | MLTPL | |
CR67 | [1] | CLD 23 | MLTPL | |
EDR Spacer | [2] | CLD 23 | MLTPL | |
EDR Stack[3] | [4] | CLD 23 | MLTPL | |
Ionics V20 EDR Stack[3] | [5] | CLD 23 | MLTPL | |
MK IV-2 | [6] | CLD 23 | MLTPL | |
NFEDR AR908 coated electrode | [6] | CLD 23 | MLTPL | |
[1] AR204, CR64, CR67 and AR908 are certified for a minimum flow of 60,000 gallons per day when used in the EDR stack and 30,000 gallons per day when used in the Ionics V20 EDR Stack. [2] EDR Spacer and AR404 Coated Electrode are certified for a minimum flow of 30,000 gallons per day. [3] The EDR Stacks consist of an anion membrane (AR204 or AR908), cation membrane (CR67 or CR64) and intermembrane spacers (MK IV Spacer or EDR Spacer) and may contain a coated electrode (AR908 or AR404). Individual components are certified as replacement parts for the EDR Stack and the Ionics V20 EDR Stack. [4] EDR Stack is certified for a minimum flow of 60,000 gallons per day. [5] Ionics V20 EDR Stack is certified for a minimum flow of 30,000 gallons per day. [6] MK IV-2 and NFEDR AR908 Coated Electrode are certified for a minimum flow of 60,000 gallons per day. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Minnetonka, MN
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Filtration Devices/Components[1] [G] |
||||
Adv. Industrial Grade filter (AIG.Z) | 2 1/2" | CLD 23 | PP | |
Filterplex.Z (FP.Zs) | 2 1/2" | CLD 23 | PP | |
HYTREX - GX SERIES | 2 1/2" | CLD 23 | PP | |
HYTREX - RX SERIES | 2 3/4" | CLD 23 | PP | |
LD SERIES | 2 1/2" | CLD 23 | PP | |
MB01-10 | 2 1/2" | CLD 23 | PP | |
MB01-20 | 2 1/2" | CLD 23 | PP | |
MB05-10 | 2 1/2" | CLD 23 | PP | |
MB05-20 | 2 1/2" | CLD 23 | PP | |
MB10-10 | 2 1/2" | CLD 23 | PP | |
MB10-20 | 2 1/2" | CLD 23 | PP | |
MB25-10 | 2 1/2" | CLD 23 | PP | |
MB25-20 | 2 1/2" | CLD 23 | PP | |
P-MBC01-10 | 2 1/2" | CLD 23 | PP | |
P-MBC01-20 | 2 1/2" | CLD 23 | PP | |
PURTREX - PX SERIES | 2 1/2" | CLD 23 | PP | |
Purtrex Plus (PXP.Z) | 2 1/2" | CLD 23 | PP | |
Ro.Save.Z | 2 1/2" | CLD 23 | PP | |
SELEX - SX SERIES | 2 1/2" | CLD 23 | PP | |
SWRO.Z [MM-LL-XXX] | 2 1/2" | CLD 23 | PP | |
Wellpro.Z (WP) | 2 1/2" | CLD 23 | PP | |
Z.Core (Z.Core MM-LL-XXX) | 2 1/2" | CLD 23 | PP | |
Z.Plex Absolute.Za (Abs.Za MM-LL-XXX) | 2.6" | CLD 23 | PP | |
Z.Plex EDR.Z (EDR.Z MM-LL-XXX) | 2 1/2" | CLD 23 | PP | |
Z.Plex HF.EDR.Z (MM-LL-XXX) | 6 1/2"" | CLD 23 | PP | |
Z.Plex HF.RO.Zs (MM-LL-XXX) | 6 1/2" | CLD 23 | PP | |
Z.Plex Muni.Zs (Muni.Zs MM-LL-XXX) | 2 1/2" | CLD 23 | PP | |
Z.Plex ROsave.Zs (RO.Zs MM-LL-XXX) | 2 1/2" | CLD 23 | PP | |
[Z.Plex HF.Za (MM-LL-XXX)] | 6 1/2" | CLD 23 | PP | |
[Z.Plex HF.Zs (MM-LL-XXX)] | 6 1/2" | CLD 23 | PP | |
[1] Number shown in size is the outer diameter. MM: Micron rating 95 - 0.5 01 to 200 (Equals micron rating as indicated by number) LL: Length 10 - 70" XXX: End adapters and O-Rings/Gasket options The PX, GX, LD, SX, RX, RO.Save.Z, WellproZ (WP), Purtrex Plus (PXP.Z) and Adv Industrial Grade filter (AIG.Z) designations will generally follow the format XXYY-ZZ-AB. XX - Series type YY - Micron rating ZZ - Length AB - End Adapters and O-Rings/Gasket options Additional Suffixes: YKP - Single Santoprene gasket, Polypropylene spring YKLP - Single Santoprene gasket, Extended core, Polypropylene spring YYP - Two santoprene gaskets End adapter and O-rings are optional and a suffix may or may not appear. End 1 A - Open end w/ gasket E - 222 Adapter w/ O-Ring F - 226 Adapter w/ O-Ring L - Extended core X - Open end (no adapter) Y - 1 inch (2.54 cm) Open end gasket End 2 A - Open end w/gasket K - Self seal spring H - Fin S - Solid end T - 338 adapter w/O-ring X - Open end (no adapter) Y - 1 inch (2.54 cm) Open end Gasket O-Ring and Gasket Material B - Buna-N E - EPDM P - Santoprene S - Silicone V - Viton2 Viton is a registered trademark of DuPont Dow Elastomers. Certified for a minimum flow of 720 gallons/day/10" of filter. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||
Reverse Osmosis Element [2] [G] |
||||
AG-365 (3056666) | 8" | CLD 23 | MLTPL | |
AG-400 (3056667) | 8" | CLD 23 | MLTPL | |
AG-400, 34 (3056668) | 8" | CLD 23 | MLTPL | |
AG-440 (3056669) | 8" | CLD 23 | MLTPL | |
AG-90 (3056665) | 4" | CLD 23 | MLTPL | |
AG4040FM (3032513) | 4" | CLD 23 | MLTPL | |
AG8040F (3032515) | 8" | CLD 23 | MLTPL | |
AG8040F-400 (3032518) | 8" | CLD 23 | MLTPL | |
AG8040F-440 (3194307) | 8" | CLD 23 | MLTPL | |
AK-365 (3056679) | 8" | CLD 23 | MLTPL | |
AK-400 (3056680) | 8" | CLD 23 | MLTPL | |
AK-400, 34 (3156843) | 8" | CLD 23 | MLTPL | |
AK-440 (3056681) | 8" | CLD 23 | MLTPL | |
AK4040FM (3039082) | 4" | CLD 23 | MLTPL | |
AK4040FM (3039082) | 4" | CLD 23 | MLTPL | |
AK8040F (3039160) | 8" | CLD 23 | MLTPL | |
AK8040F-400 (3039161) | 8" | CLD 23 | MLTPL | |
AK8040F-440 (3194308) | 8" | CLD 23 | MLTPL | |
AP-400 (3134276) | 8" | CLD 23 | MLTPL | |
BEV-NF-400-FF (3158137) | 8" | CLD 23 | MLTPL | |
BEV-NF-440-FF (3158139) | 8" | CLD 23 | MLTPL | |
BEV-RO-400-CG (3158143) | 8" | CLD 23 | MLTPL | |
BEV-RO-400-FF (3158136) | 8" | CLD 23 | MLTPL | |
BEV-RO-440-CG (3158152) | 8" | CLD 23 | MLTPL | |
BEV-RO-440-FF (3158138) | 8" | CLD 23 | MLTPL | |
BEV-RO-CG (3205636) | 8" | CLD 23 | MLTPL | |
BEV-RO-LE-400-FF (3158150) | 8" | CLD 23 | MLTPL | |
BEV-RO-LE-440-FF (3158151) | 8" | CLD 23 | MLTPL | |
BEV-RO-LE-CG (3205637) | 8" | CLD 23 | MLTPL | |
BEV-RO-ULE-CG (3205638) | 8" | CLD 23 | MLTPL | |
CE8040F, (3097264) | 8" | CLD 23 | MLTPL | |
DK-440 (3154650) | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM EXL RO 8040 (1231723) | 8" | CLD 23 | MLTPL | |
DURATHERM HWS RO4040 (1228459) | 4" | CLD 23 | MLTPL | |
DURATHERM HWS RO4040HR (1263435) | 4" | CLD 23 | MLTPL | |
DURATHERM HWS RO8040 (1228481) | 8" | CLD 23 | MLTPL | |
DURATHERM HWS RO8040HR (1263599) | 8" | CLD 23 | MLTPL | |
DURATHERM STD RO4040 (1228197) | 4" | CLD 23 | MLTPL | |
DURATHERM STD RO8040 (1228225) | 8" | CLD 23 | MLTPL | |
Durafoul RO1 (3198543) | 8" x 40" | CLD 23 | MLTPL | |
MUNI-NF-400 (1242400) | 8" | CLD 23 | MLTPL | |
MUNI-RO-400-HR (3051521) | 8" | CLD 23 | MLTPL | |
MUNI-RO-400-HR-LE (3051113) | 8" | CLD 23 | MLTPL | |
MUNI-RO-400-LE-WT-FF (3044144) | 8" | CLD 23 | MLTPL | |
MUNI-RO-400-ULE (3147561) | 8" | CLD 23 | MLTPL | |
MUNI-RO-430-HR (3051522) | 8" | CLD 23 | MLTPL | |
MUNI-RO-430-HR-LE (3051114) | 8" | CLD 23 | MLTPL | |
OSMO-BEV-RO-CA-FF (3133706) | 8" | CLD 23 | MLTPL | |
OSMO-BEV-RO-CG-WT (1266767) | 8" | CLD 23 | MLTPL | |
OSMO-BEV-RO-FF (1233032) | 8" | CLD 23 | MLTPL | |
OSMO-BEV-RO-LE-FF-WT (3027042) | 8" | CLD 23 | MLTPL | |
OSMO-BEV-RO-ULE-CG-WT (3099336) | 8" | CLD 23 | MLTPL | |
OSMO-BEV-UF-FF (1233034) | 8" | CLD 23 | MLTPL | |
PT8040F30 (1229772) | 8" | CLD 23 | MLTPL | |
R&D, ELEMENT, OSMO-BEV-RO-ULE-CG-WT, AL[2] [3] | 8" x 40" | CLD 23 | MLTPL | |
[2] Elements with 4" diameter are Certified for a minimum flow of 7,078 liters/day. Elements with 8" diameter are Certified for a minimum flow of 29,602 liters/day. Certification is for the membrane elements only. Product requires a 2-hour conditioning flush to drain with de-ionized water at 12L/min before use. [2] Elements with 4" diameter are Certified for a minimum flow of 7,078 liters/day. Elements with 8" diameter are Certified for a minimum flow of 29,602 liters/day. Certification is for the membrane elements only. Product requires a 2-hour conditioning flush to drain with de-ionized water at 12L/min before use. [3] R&D, ELEMENT, OSMO-BEV-RO-ULE-CG-WT, AL model requires a 2-hour conditioning flush to drain with de-ionized water at 10 gpm before use. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or documentation shipped with the product are Certified.
Facility : Guelph, Ontario, Canada
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Miscellaneous Process Devices/Components [G] |
||||
EDR Stack | [1] | CLD 23 | MLTPL | |
Ionics V20 EDR Stack | [2] | CLD 23 | MLTPL | |
[1] Certified for a minimum flow of 60,000 gallons per day. [2] Ionics V20 EDR Stack is certified for a minimum flow of 30,000 gallons per day. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Wuxi New District, China
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Reverse Osmosis Element[1] [G] |
||||
AG-365 (3056666) | 8" x 40" | CLD 23 | MLTPL | |
AG-400 (3056667) | 8" x 40" | CLD 23 | MLTPL | |
AG-400, 34 (3056668) | 8" x 40" | CLD 23 | MLTPL | |
AG-90 (3056665) | 4" x 40" | CLD 23 | MLTPL | |
AG4040F LF WET (3056468) | 8" x 40" | CLD 23 | MLTPL | |
AG4040FM (3032513) | 4" x 40" | CLD 23 | MLTPL | |
AG8040F (3032515) | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-400 (3032518) | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-400 FR, 34 (3136931) | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-400 LF, 34 (3149711) | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-440 (3194307) | 8" x 40" | CLD 23 | MLTPL | |
AK-400 (3056680) | 8" x 40" | CLD 23 | MLTPL | |
AK4040FM (3039082) | 4" x 40" | CLD 23 | MLTPL | |
AK8040F (3039160) | 8" x 40" | CLD 23 | MLTPL | |
AK8040F-400 (3039161) | 8" x 40" | CLD 23 | MLTPL | |
AK8040F-440 (3194308) | 8" x 40" | CLD 23 | MLTPL | |
AL-400 (3193741) | 8" x 40" | CLD 23 | MLTPL | |
AL-440 (3193742) | 8" x 40" | CLD 23 | MLTPL | |
AL-90 (3193740) | 4" x 40" | CLD 23 | MLTPL | |
AP-400 (3134276 | 8" x 40" | CLD 23 | MLTPL | |
AP-90 (3063034) | 4" x 40" | CLD 23 | MLTPL | |
BEV-RO-CG (3205636) | 8" | CLD 23 | MLTPL | |
BEV-RO-LE-CG (3205637) | 8" | CLD 23 | MLTPL | |
BEV-RO-ULE-CG (3205638) | 8" | CLD 23 | MLTPL | |
DK-440 (3154650) | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM EXL RO 8040 (1231723) | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM HWS RO4040 (1228459) | 4" x 40" | CLD 23 | MLTPL | |
DURATHERM HWS RO4040HR (1263435) | 4" x 40" | CLD 23 | MLTPL | |
DURATHERM HWS RO8040 (1228481) | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM HWS RO8040HR (1263599) | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM STD RO4040 (1228197) | 4" x 40" | CLD 23 | MLTPL | |
DURATHERM STD RO8040 (1228225) | 8" x 40" | CLD 23 | MLTPL | |
Durafoul RO1 (3198543) | 8" x 40" | CLD 23 | MLTPL | |
Element, Industrial RO7 HP 8040F35 (31690180) | 8" x 40" | CLD 23 | MLTPL | |
HL4040FM (1207236) | 8" x 40" | CLD 23 | MLTPL | |
HL8040F-400 (1207240) | 8" x 40" | CLD 23 | MLTPL | |
HN4040FM (3205804) | 4" x 40" | CLD 23 | MLTPL | |
HN8040F-400 (3205802) | 8" x 40" | CLD 23 | MLTPL | |
HN8040F-440 (3205803) | 8" x 40" | CLD 23 | MLTPL | |
OSMO-BEV-RO-FF (1233032) | 8" x 40" | CLD 23 | MLTPL | |
OSMO-BEV-RO-ULE-CG-WT (3099336) | 8" x 40" | CLD 23 | MLTPL | |
[1] Elements with 4" diameter are certified for a minimum flow of 7,078 liters/day. Elements with 8" diameter are certified for a minimum flow of 29,602 liters/day. Certification is for the membrane elements only. Product requires a 2-hour conditioning flush to drain with potable water before use. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Bitterfeld-Wolfen, Germany
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Reverse Osmosis Element[1] [G] |
||||
AG-400 FR H[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-400 H[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-400 LE H[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-400 P[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-400 P FR[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-400 P FR, 34 (ASD)[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-400 P LE, 34 (ASD) | 8" x 40" | CLD 23 | MLTPL | |
AG-440 H[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-440 LE H[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-440 P[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-440 P LE[3] | 8" x 40" | CLD 23 | MLTPL | |
AG-85 P FR[2] | 3.9" x 40" | CLD 23 | MLTPL | |
AG-85 P LE[2] | 3.9" x 40" | CLD 23 | MLTPL | |
AG8040F-400[3] | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-400 FR[3] | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-400 LE[3] | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-440[3] | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-440 LE[3] | 8" x 40" | CLD 23 | MLTPL | |
AK-400 H[3] | 8" x 40" | CLD 23 | MLTPL | |
AK-400 P, 34 (ASD)[3] | 8" x 40" | CLD 23 | MLTPL | |
AK-440 H[3] | 8" x 40" | CLD 23 | MLTPL | |
AK-440 P[3] | 8" x 40" | CLD 23 | MLTPL | |
AK-85 P[2] | 3.9" x 40" | CLD 23 | MLTPL | |
AK8040F-400[3] | 8" x 40" | CLD 23 | MLTPL | |
AK8040F-440[3] | 8" x 40" | CLD 23 | MLTPL | |
[1] The Listed size is the element diameter x length. [2] 3.9 x 40 inch elements are certified for a minimum daily permeate flow of 4,163 L. [3] 8 x 40 inch elements are certified for a minimum daily permeate flow of 29,000 L. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NOTE: Only products bearing the NSF Mark are Certified.
Facility : Oroszlány, Hungary
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Reverse Osmosis Element [G] |
||||
AG-365 (3056666)[1] [2] | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-400 FR,34 (3136931)[4] | 8" x 40" | CLD 23 | MLTPL | |
AG-400 (3056667)[1] [2] | 8" x 40" | CLD 23 | MLTPL | |
AG-90 (3056665)[4] | 8" x 40" | CLD 23 | MLTPL | |
AG8040F (3032515)[4] | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-400 (3032518)[4] | 8" x 40" | CLD 23 | MLTPL | |
AG4040FM (3032513)[4] | 4" x 40" | CLD 23 | MLTPL | |
AK-400 (3056680)[1] [2] | 8" x 40" | CLD 23 | MLTPL | |
AK-400, 34 (3156843)[4] | 8" x 40" | CLD 23 | MLTPL | |
AK4040FM (3039082)[4] | 4" x 40" | CLD 23 | MLTPL | |
AK8040F (3039160)[4] | 8" x 40" | CLD 23 | MLTPL | |
AK8040F-400 (3039161)[4] | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM HWS RO8040 (1228481)[4] | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM HWS RO8040HR (1263599)[4] | 8" x 40" | CLD 23 | MLTPL | |
DURATHERM STD RO8040 (1228225)[4] | 8" x 40" | CLD 23 | MLTPL | |
[1] Certified for a minimum flow of 29,602 liters/day. [2] Product requires a 2-hour conditioning flush to drain with potable water before use. [4] Elements with 4" diameter are Certified for a minimum flow of 7,078 liters/day. Elements with 8" diameter are Certified for a minimum flow of 29,602 liters/day. Product requires a 2-hour conditioning flush to drain with de-ionized water as 12L/min before use. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||
Ultrafiltration Devices [G] |
||||
ZeeWeed 500S[5] | 27.7 cm x 178 cm | CLD 23 | MLTPL | |
ZeeWeed 500a UF[6] | NA | CLD 23 | MLTPL | |
ZeeWeed 500b UF[7] | NA | CLD 23 | MLTPL | |
ZeeWeed 500c UF[8] | NA | CLD 23 | MLTPL | |
ZeeWeed 500d UF[9] | NA | CLD 23 | MLTPL | |
ZeeWeed 1000V2 Module[10] | NA | CLD 23 | MLTPL | |
ZeeWeed 1000 V3[11] | NA | CLD 23 | MLTPL | |
ZeeWeed 1000 V4[11] | NA | CLD 23 | MLTPL | |
ZeeWeed 1500 Module | 7" x 70"[12] | CLD 23 | MLTPL | |
ZeeWeed 1500 RMS[13] [14] | NA | CLD 23 | MLTPL | |
ZW700B-450[15] [16] | 4.3" x 27.6"[12] | CLD 23 | MLTPL | |
ZW700B-4100[15] [16] | 4.3" x 47.2"[12] | CLD 23 | MLTPL | |
ZW700B-4150[15] [16] | 4.3" x 66.9"[12] | CLD 23 | MLTPL | |
ZW700B-6100[15] [16] | 5.5" x 49.3"[12] | CLD 23 | MLTPL | |
ZW700B-8060/X[15] [16] | 8" x 60"[12] | CLD 23 | MLTPL | |
ZW700B-9060[15] [16] | 9" x 60"[12] | CLD 23 | MLTPL | |
ZW700B-10060[15] [16] | 13" x 66"[12] | CLD 23 | MLTPL | |
ZW700B-RMS[17] [18] | 25 cm x 185 cm | CLD 23 | MLTPL | |
ZW1000- NGC Assembly[11] | 18" | CLD 23 | MLTPL | |
[5] Certified for a minimum daily flow of 5,000 liters per day. Flush for 2.5-5 gpm for 7.5 - 15 hours. [6] Certification based on minimum daily flow of 8,000 liters per module. [7] Certification based on minimum daily flow of 11,000 liters per module. [8] Certification based on minimum daily flow of 4,000 liters per module. [9] Certification based on minimum daily flow of 5,000 liters per day per module. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. [10] Certification based on minimum daily permeate flow of 12,000 liters per module. [11] Certification based on minimum daily flow when in operation of 12,000 liters per module. [12] Size is expressed as diameter x length. [13] Certification based on minimum daily flow of 25,000 liters per module. [14] Modules should be flushed for 30 minutes with tap water at 10 gallons per minute. [15] The ZW700B-450 model is Certified for a minimum daily flow of 3,180 L. The ZW700B-4100 model is Certified for a minimum daily flow of 6,960 L. The ZW700B-4150 model is Certified for a minimum daily flow of 10,800 L. The ZW700B-6100 model is Certified for a minimum daily flow of 14,400 L. The ZW700B-8060/X model is Certified for a minimum daily flow of 16,000 L. The ZW700B-9060 model is Certified for a minimum daily flow of 22,000 L. The ZW700B-10060 model is Certified for a minimum daily flow of 24,000 L. [16] Flush the models under the following conditions: ZW700B-450 for 30 minutes at a flow rate of 5,168 liters per minute using tap water. ZW700B-4100 for 30 minutes at a flow rate of 11,310 liters per minutes using tap water. ZW700B-4150 for 30 minutes at a flow rate of 17,550 liters per minutes using tap water. ZW700B-6100 for 30 minutes at a flow rate of 23,400 liters per minutes using tap water. ZW700B-8060/X for 75 minutes at a flow rate of 35-53 liters per minutes using tap water. ZW700B-9060 for 75 minutes at a flow rate of 35-53 liters per minutes using tap water. ZW700B-10060 for 60 minutes at a flow rate of 50-80 liters per minute using raw feed water. [17] ZW700B-RMS is certified to a minimum daily flow of 34,000 liters per day. [18] ZW700B-RMS is flushed for 80 minutes at a flow rate of 70-116 liters per minute using raw feed water. |
[3] Product requires a 2-hour conditioning flush to drain with de-ionized water at 12 L/min before use.
Facility : Hoskote, Bangalore, India
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Reverse Osmosis Element[1] [G] |
||||
AG8040F-400 LE (3160987) | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-440 (3194307) | 8" x 40" | CLD 23 | MLTPL | |
AG8040F-440 LE (3194309) | 8" x 40" | CLD 23 | MLTPL | |
AK8040F-440 (3194308) | 8" x 40" | CLD 23 | MLTPL | |
BEV-RO-CG (3205636) | 8" | CLD 23 | MLTPL | |
BEV-RO-LE-CG (3205637) | 8" | CLD 23 | MLTPL | |
BEV-RO-ULE-CG (3205638) | 8" | CLD 23 | MLTPL | |
ELEMENT, AG-365 - 3056666 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG-400 - 3056667 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG-400,34 - 3056668 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG-90 - 3056665 | 4" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG4040F, 34 - 3154063 | 4" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG4040FM - 3032513 | 4" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG4040TM- 3032514 | 4" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG8040F - 3032515 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG8040F 400FR, 34 HF - 3156629 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG8040F-400 - 3032518 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, AG8040F-400 FR,34 - 3136931 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, AK4040FM - 3039082 | 4" x 40" | CLD 23 | MLTPL | |
ELEMENT, AK4040TM- 3039149 | 4" x 40" | CLD 23 | MLTPL | |
ELEMENT, AK8040F-400 - 3039161 | 8" x 40" | CLD 23 | MLTPL | |
ELEMENT, MAPLE RO8040, 34 - 3185573 | 8" x 40" | CLD 23 | MLTPL | |
Element, AG-440 - 3056669 | 8" x 40" | CLD 23 | MLTPL | |
Element, AG8040F-400 LF, 34 - 3149711 | 8" x 40" | CLD 23 | MLTPL | |
Element, AK-365 - 3056679 | 8" x 40" | CLD 23 | MLTPL | |
Element, AK-400 - 3056680 | 8" x 40" | CLD 23 | MLTPL | |
Element, AK-400, 34 - 3156843 | 8" x 40" | CLD 23 | MLTPL | |
Element, AK-440 - 3056681 | 8" x 40" | CLD 23 | MLTPL | |
Element, AK8040F - 3039160 | 8" x 40" | CLD 23 | MLTPL | |
Element, AP-365 - 3056613 | 8" x 40" | CLD 23 | MLTPL | |
Element, AP-400 - 3134276 | 8" x 40" | CLD 23 | MLTPL | |
Element, AP-90 - 3063034 | 4" x 40" | CLD 23 | MLTPL | |
[1] Elements with 4" diameter are Certified for a minimum flow of 7,078 liters/day. Elements with 8" diameter are Certified for a minimum flow of 29,602 liters/day. The products require a 2-hour conditioning flush to drain with de-ionized water at 10 gpm before use. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Zeewolde, The Netherlands
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Ultrafiltration Devices[1] [2] [3] [G] |
||||
ZW700B-10060 | 13" x 66" | CLD 23 | MLTPL | |
ZW700B-10072 | 25 x 185 cm | CLD 23 | MLTPL | |
ZW700B-4100 | 4.3 x 47.2 in | CLD 23 | MLTPL | |
ZW700B-4150 | 4.3 x 66.9 in | CLD 23 | MLTPL | |
ZW700B-450 | 4.3 x 27.6 in | CLD 23 | MLTPL | |
ZW700B-6100 | 5.5 x 49.3 in | CLD 23 | MLTPL | |
ZW700B-8060/X | 8" x 60" | CLD 23 | MLTPL | |
ZW700B-9060 | 9" x 60" | CLD 23 | MLTPL | |
[1] Size is expressed as diameter x length. [2] The ZW700B-450 model is Certified for a minimum daily flow of 3,180 L. The ZW700B-4100 model is Certified for a minimum daily flow of 6,960 L. The ZW700B-4150 model is Certified for a minimum daily flow of 10,800 L. The ZW700B-6100 model is Certified for a minimum daily flow of 14,400 L. The ZW700B-8060/X model is Certified for a minimum daily flow of 16,000 L. The ZW700B-9060 model is Certified for a minimum daily flow of 22,000 L. The ZW700B-10060 model is Certified for a minimum daily flow of 24,000 L. The ZW700B-10072 model is certified to a minimum daily flow of 34,000 liters per day. [3] Flush the models under the following conditions: ZW700B-450 for 30 minutes at a flow rate of 5,168 liters per minute using tap water. ZW700B-4100 for 30 minutes at a flow rate of 11,310 liters per minutes using tap water. ZW700B-4150 for 30 minutes at a flow rate of 17,550 liters per minutes using tap water. ZW700B-6100 for 30 minutes at a flow rate of 23,400 liters per minutes using tap water. ZW700B-8060/X for 75 minutes at a flow rate of 35-53 liters per minutes using tap water. ZW700B-9060 for 75 minutes at a flow rate of 35-53 liters per minutes using tap water. ZW700B-10060 for 60 minutes at a flow rate of 50-80 liters per minute using raw feed water. ZW700B-10072 for 60 minutes at a flow rate of 70-115 liters per minute using raw feed water. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |