NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Aliaxis Deutschland GmbH 
Steinzeugstrasse 50
D-68222 Mannheim 
Germany 
49 621 486 1540


Facility : Mannheim, Germany

Pipes and Related Products

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fittings [G]
Frialen Couplers with removable stop MB 20 mm - 160 mm CLD 23 PE
Frialen Couplers with removable stop MBI[1] 1/2" - 6" CLD 23 PE
Frialen Elbow 90 1", 1 1/4", 2", 4" CLD 23 PE
Frialen End Cap 1", 1 1/4", 2", 4" CLD 23 PE
Frialen Electrofusion Reducers MR 32x16mm - 225x160mm CLD 23 PE
Frialen Electrofusion Reducers MRI[2] 1" x 1/2" - 2 x 1" CLD 23 PE
Frialen Frialen Coupler UBI Fittings[3] 8" - 30" CLD 23 PE
Frialen Slide-over couplers UB and UB-XL 20 mm - 1200 mm CLD 23 PE
Frialen Tee with Spigot Outlet 1", 1 1/4", 2", 4" CLD 23 PE

[1] MBI - MB is the FRIATEC identification for a coupler with a removable stop, I indicates
    inch size.
[2] MRI - MR is the FRIATEC identification for an e/f reducer, I indicates inch size.
[3] UBI - UB is the FRIATEC identification for a coupler without a stop, I indicates inch
    size.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Service Saddles [G]
Frialen Electrofusion Reducers MRI 3" x 2" - 6" x 4" CLD 23 MLTPL
FRIALEN® Valve Tapping Saddle VA 63mm - 225mm x 1 ¼"[4] CLD 23 MLTPL
Frialen® Valve Tapping Saddle VA-TL[5] 250mm - 560mm x 2"[4] CLD 23 MLTPL
Frialen® Valve Tapping Saddle VA 3" x 2" - 6" x 2"[4] CLD 23 MLTPL
FRIALEN® Valve Tapping Saddle VA-TL[5] 8"x2" - (10"-22")x2"[4] [6] CLD 23 MLTPL
Frialen® Spigot Saddles SA 63x32mm-225x160mm[4] CLD 23 MLTPL
FRIALEN® Spigot Saddles SA-TL[5] 8"x2" - (10"-22")x3"[4] [6] CLD 23 MLTPL
FRIALEN®-Repair and Reinforcing Saddles VVS 90mmx50mm-225mmx50mm[4] CLD 23 MLTPL
Frialen®-Repair and Reinforcing Saddles VVS 3" - 6"[4] CLD 23 MLTPL
FRIALEN®-Repair Saddle Top-Loading VSC-TL 250mm - 560mm x 50mm[4] CLD 23 MLTPL
Frialen®-Repair Saddle Top-Loading VSC-TL[5] 8x50 mm (10-22)x50mm[4] [6] CLD 23 MLTPL

[4] Size - The first number refers to the diameter of the host pipe and the second number
    refers to the diameter of the outlet.
[5] TL - FRIATEC pneumatic Top-Loading tool required.
[6] Dimensions given in brackets, e.g. SA-TL d(10-22) x 3:
    This saddle fitting can be fused on a main pipe of a size which is between and including
    10 to 22 inch. 3 inch indicates the size of the outlet. 
    The dimension indication "(xx-yy)" is only possible for saddles.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tapping Sleeves [G]
FRIALEN® Pressure Tapping Tees with extra long outlet spigot DAA 1 1/4"x1/2"-8"x2"[4] CLD 23 MLTPL
Frialen® Pressure Tapping Tees with extra long outlet spigot DAA-TL[5] (10"-16") x 2"[4] [6] CLD 23 MLTPL
Frialen® Pressure Tapping Tees with extra long outlet spigot DAA 40mmx20mm-225mmx63mm[4] CLD 23 MLTPL

[4] Size - The first number refers to the diameter of the host pipe and the second number
    refers to the diameter of the outlet.
[5] TL - FRIATEC pneumatic Top-Loading tool required.
[6] Dimensions given in brackets, e.g. SA-TL d(10-22) x 3:
    This saddle fitting can be fused on a main pipe of a size which is between and including
    10 to 22 inch. 3 inch indicates the size of the outlet. 
    The dimension indication "(xx-yy)" is only possible for saddles.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Number of matching Manufacturers is 1
Number of matching Products is 23