NSF Product and Service Listings

These NSF Official Listings are current as of Saturday, November 23, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=82070&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Poly Processing Company 
2201 Old Sterlington Road
Monroe, LA 71203 
United States 
800-523-9871 
318-343-7565
Visit this company's website


Facility : French Camp, CA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Chemical Storage Tanks
Chemical Storage Tanks[1] [2] >= 55 gal. CLD 23 MLTPL
Chemical Storage Tanks with OR-1000™ System[2] [3] >= 55 gal. CLD 23 MLTPL

[1] The Chemical Storage Tanks are Certified for use with the following media at the maximum
    concentration listed below. These products are evaluated by diluting the stored water
    treatment chemical to its maximum use level (MUL), as defined in NSF/ANSI/CAN 60. 
    Acetic Acid (80%)
    Aluminum Chlorohydrate (100%) Aluminum Sulfate (50%)
    Calcium Carbonate (100%)
    Calcium Chloride (30%)
    Chlorine Dioxide (38%)
    Citric Acid (100%)
    Copper Sulfate (25%)
    Ferric Chloride (50%)
    Ferric Sulfate (60%)
    Ferrous Chloride (37%)
    Ferrous Sulfate (30%)
    Hydrochloric Acid (37%)
    Hydrofluoric Acid (52%)
    Hydrofluorosilicic Acid (30%)
    Hydrogen Peroxide (10%)
    Liquid Ammonium Sulfate (45%)
    Magnesium Chloride (35%)
    Peracetic Acid (30%)
    Phosphoric Acid (75%)
    Poly Aluminum Chloride (100%)
    Polyorthophosphate (100%)
    Potassium Hydroxide (50%)
    Potassium Permanganate (4%)
    Sodium Aluminate (100%)
    Sodium Bisulfite (40%)
    Sodium Carbonate (85%)
    Sodium Chloride (26%)
    Sodium Chlorite (34%)
    Sodium Hydroxide (50%)
    Sodium Hypochlorite (<=15%)
    Sodium Permanganate (40%)
    Sodium Silicate (100%)
    Zinc Orthophosphate (100%)
[2] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[3] The OR-1000™ tanks are Certified for use with the following media at the maximum
    concentration listed below. These products are evaluated by diluting the stored water
    treatment chemical to its maximum use level (MUL), as defined in NSF/ANSI/CAN 60.
    Acetic Acid (80%)
    Aluminum Chlorohydrate (100%) 
    Aluminum Sulfate (50%) 
    Calcium Carbonate (100%) 
    Calcium Chloride (30%) 
    Chlorine Dioxide (38%) 
    Citric Acid (100%) 
    Copper Sulfate (25%) 
    Deionized Water (100%)*
    Ferric Chloride (50%) 
    Ferric Sulfate (60%) 
    Ferrous Chloride (37%) 
    Ferrous Sulfate (30%) 
    Hydrochloric Acid (37%) 
    Hydrofluoric Acid (52%) 
    Hydrofluorosilicic Acid (30%) 
    Liquid Ammonium Sulfate (45%) 
    Magnesium Chloride (35%) 
    Phosphoric Acid (75%) 
    Poly Aluminum Chloride (100%) 
    Polyorthophosphate (100%) 
    Potassium Hydroxide (50%) 
    Potassium Permanganate (4%)
    Sodium Aluminate (100%) 
    Sodium Bisulfite (40%) 
    Sodium Carbonate (85%) 
    Sodium Chloride (26%) 
    Sodium Chlorite (34%) 
    Sodium Hydroxide (50%) 
    Sodium Hypochlorite (0.8%) 
    Sodium Hypochlorite (15%) 
    Sodium Permanganate (40%) 
    Sodium Silicate (100%) 
    Sulfuric Acid (98%) 
    Zinc Orthophosphate (100%)
    * Certified for contact with DI water for the purpose of diluting drinking water
    treatment chemicals.


Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Tanks
Linear Potable Water Storage Tanks[1] [2] >= 55 gal. CLD 23 MLTPL

[1] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[2] Certified for black, green, and natural tanks.



Facility : Monroe, LA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Chemical Storage Tanks
Chemical Storage Tanks[1] [2] >= 55 gal. CLD 23 MLTPL
Chemical Storage Tanks with OR-1000™ System[2] [3] >= 55 gal. CLD 23 MLTPL

[1] The Chemical Storage Tanks are Certified for use with the following media at the maximum
    concentration listed below. These products are evaluated by diluting the stored water
    treatment chemical to its maximum use level (MUL), as defined in NSF/ANSI/CAN 60. 
    Acetic Acid (80%)
    Aluminum Chlorohydrate (100%) Aluminum Sulfate (50%)
    Calcium Carbonate (100%)
    Calcium Chloride (30%)
    Chlorine Dioxide (38%)
    Citric Acid (100%)
    Copper Sulfate (25%)
    Ferric Chloride (50%)
    Ferric Sulfate (60%)
    Ferrous Chloride (37%)
    Ferrous Sulfate (30%)
    Hydrochloric Acid (37%)
    Hydrofluoric Acid (52%)
    Hydrofluorosilicic Acid (30%)
    Hydrogen Peroxide (10%)
    Liquid Ammonium Sulfate (45%)
    Magnesium Chloride (35%)
    Peracetic Acid (30%)
    Phosphoric Acid (75%)
    Poly Aluminum Chloride (100%)
    Polyorthophosphate (100%)
    Potassium Hydroxide (50%)
    Potassium Permanganate (4%)
    Sodium Aluminate (100%)
    Sodium Bisulfite (40%)
    Sodium Carbonate (85%)
    Sodium Chloride (26%)
    Sodium Chlorite (34%)
    Sodium Hydroxide (50%)
    Sodium Hypochlorite (<=15%)
    Sodium Permanganate (40%)
    Sodium Silicate (100%)
    Zinc Orthophosphate (100%)
[2] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[3] The OR-1000™ tanks are Certified for use with the following media at the maximum
    concentration listed below. These products are evaluated by diluting the stored water
    treatment chemical to its maximum use level (MUL), as defined in NSF/ANSI/CAN 60.
    Acetic Acid (80%)
    Aluminum Chlorohydrate (100%) 
    Aluminum Sulfate (50%) 
    Calcium Carbonate (100%) 
    Calcium Chloride (30%) 
    Chlorine Dioxide (38%) 
    Citric Acid (100%) 
    Copper Sulfate (25%) 
    Deionized Water (100%)*
    Ferric Chloride (50%) 
    Ferric Sulfate (60%) 
    Ferrous Chloride (37%) 
    Ferrous Sulfate (30%) 
    Hydrochloric Acid (37%) 
    Hydrofluoric Acid (52%) 
    Hydrofluorosilicic Acid (30%) 
    Liquid Ammonium Sulfate (45%) 
    Magnesium Chloride (35%) 
    Phosphoric Acid (75%) 
    Poly Aluminum Chloride (100%) 
    Polyorthophosphate (100%) 
    Potassium Hydroxide (50%) 
    Potassium Permanganate (4%)
    Sodium Aluminate (100%) 
    Sodium Bisulfite (40%) 
    Sodium Carbonate (85%) 
    Sodium Chloride (26%) 
    Sodium Chlorite (34%) 
    Sodium Hydroxide (50%) 
    Sodium Hypochlorite (0.8%) 
    Sodium Hypochlorite (15%) 
    Sodium Permanganate (40%) 
    Sodium Silicate (100%) 
    Sulfuric Acid (98%) 
    Zinc Orthophosphate (100%)
    * Certified for contact with DI water for the purpose of diluting drinking water
    treatment chemicals.


Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Tanks
Linear Potable Water Storage Tanks[1] [2] >= 55 gal. CLD 23 MLTPL

[1] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[2] Certified for black, green, and natural tanks.



Facility : Winchester, VA

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Chemical Storage Tanks
Chemical Storage Tanks[1] [2] >= 55 gal. CLD 23 MLTPL
Chemical Storage Tanks with OR-1000™ System[2] [3] >= 55 gal. CLD 23 MLTPL

[1] The Chemical Storage Tanks are Certified for use with the following media at the maximum
    concentration listed below. These products are evaluated by diluting the stored water
    treatment chemical to its maximum use level (MUL), as defined in NSF/ANSI/CAN 60. 
    Acetic Acid (80%)
    Aluminum Chlorohydrate (100%) Aluminum Sulfate (50%)
    Calcium Carbonate (100%)
    Calcium Chloride (30%)
    Chlorine Dioxide (38%)
    Citric Acid (100%)
    Copper Sulfate (25%)
    Ferric Chloride (50%)
    Ferric Sulfate (60%)
    Ferrous Chloride (37%)
    Ferrous Sulfate (30%)
    Hydrochloric Acid (37%)
    Hydrofluoric Acid (52%)
    Hydrofluorosilicic Acid (30%)
    Hydrogen Peroxide (10%)
    Liquid Ammonium Sulfate (45%)
    Magnesium Chloride (35%)
    Peracetic Acid (30%)
    Phosphoric Acid (75%)
    Poly Aluminum Chloride (100%)
    Polyorthophosphate (100%)
    Potassium Hydroxide (50%)
    Potassium Permanganate (4%)
    Sodium Aluminate (100%)
    Sodium Bisulfite (40%)
    Sodium Carbonate (85%)
    Sodium Chloride (26%)
    Sodium Chlorite (34%)
    Sodium Hydroxide (50%)
    Sodium Hypochlorite (<=15%)
    Sodium Permanganate (40%)
    Sodium Silicate (100%)
    Zinc Orthophosphate (100%)
[2] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[3] The OR-1000™ tanks are Certified for use with the following media at the maximum
    concentration listed below. These products are evaluated by diluting the stored water
    treatment chemical to its maximum use level (MUL), as defined in NSF/ANSI/CAN 60.
    Acetic Acid (80%) 
    Aluminum Chlorohydrate (100%)
    Aluminum Sulfate (50%) 
    Calcium Carbonate (100%) 
    Calcium Chloride (30%) 
    Chlorine Dioxide (38%) 
    Citric Acid (100%) 
    Copper Sulfate (25%) 
    Deionized Water (100%)*
    Ferric Chloride (50%) 
    Ferric Sulfate (60%) 
    Ferrous Chloride (37%) 
    Ferrous Sulfate (30%) 
    Hydrochloric Acid (37%) 
    Hydrofluoric Acid (52%) 
    Hydrofluorosilicic Acid (30%) 
    Liquid Ammonium Sulfate (45%) 
    Magnesium Chloride (35%) 
    Phosphoric Acid (75%) 
    Poly Aluminum Chloride (100%) 
    Polyorthophosphate (100%) 
    Potassium Hydroxide (50%) 
    Potassium Permanganate (4%)
    Sodium Aluminate (100%) 
    Sodium Bisulfite (40%) 
    Sodium Carbonate (85%) 
    Sodium Chloride (26%) 
    Sodium Chlorite (34%) 
    Sodium Hydroxide (50%) 
    Sodium Hypochlorite (0.8%) 
    Sodium Hypochlorite (15%) 
    Sodium Permanganate (40%) 
    Sodium Silicate (100%) 
    Sulfuric Acid (98%) 
    Zinc Orthophosphate (100%)
    * Certified for contact with DI water for the purpose of diluting drinking water
    treatment chemicals.


Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Tanks
Linear Potable Water Storage Tanks[1] [2] >= 55 gal. CLD 23 MLTPL

[1] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[2] Certified for black, green, and natural tanks.


Number of matching Manufacturers is 1
Number of matching Products is 9
Processing time was 0 seconds