Sprayroq, Inc. 
4766 Grantswood Road
Suite 150 
Irondale, AL 35210 
United States 
800-634-0504 
205-957-0020


Facility : Irondale, AL

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Fittings
SprayShield Green 1[1] >= 30" CLD 23 PUR
SprayWall®[2] >= 6" CLD 23 PUR

[1] Colors: Light Green
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): maximum 80 mils/coat; not to exceed a
    total maximum DFT of 240 mils
    Maximum thinner: None
    Recoat cure time and temperature: 15 minutes at 72°F
    Final cure time and temperature: 72 hours at 72°F
    Special comments: Mix ratio of Part A to Part B is 1:1 by volume. Application is by
    plural component spray gun. Minimum thickness is 80 mils.
[2] Colors: Gold
    Number of coats; 1
    Maximum field use dry film thickness (in mils): 500
    Maximum thinner: None
    Final cure time and temperature: 72 hours at 72°F
    Special comments: Mix ratio of Part A to Part B is 0.65:1 by volume. Minimum thickness
    is 250 mils.

Coatings - Tank
SprayWall®[2] >= 1,500,000 gal CLD 23 PUR

[2] Colors: Gold
    Number of coats; 1
    Maximum field use dry film thickness (in mils): 500
    Maximum thinner: None
    Final cure time and temperature: 72 hours at 72°F
    Special comments: Mix ratio of Part A to Part B is 0.65:1 by volume. Minimum thickness
    is 250 mils.

Coatings - Valve
SprayShield Green 1[1] >= 30" CLD 23 PUR
SprayWall®[2] >= 4" CLD 23 PUR

[1] Colors: Light Green
    Number of coats: 1-3
    Maximum field use dry film thickness (in mils): maximum 80 mils/coat; not to exceed a
    total maximum DFT of 240 mils
    Maximum thinner: None
    Recoat cure time and temperature: 15 minutes at 72°F
    Final cure time and temperature: 72 hours at 72°F
    Special comments: Mix ratio of Part A to Part B is 1:1 by volume. Application is by
    plural component spray gun. Minimum thickness is 80 mils.
[2] Colors: Gold
    Number of coats; 1
    Maximum field use dry film thickness (in mils): 500
    Maximum thinner: None
    Final cure time and temperature: 72 hours at 72°F
    Special comments: Mix ratio of Part A to Part B is 0.65:1 by volume. Minimum thickness
    is 250 mils.