NSF Product and Service Listings
These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0028348&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Square D Company | |
8001 Knightdale Boulevard | |
Knightdale, NC 27545 | |
United States | |
888-778-2733 | |
919-266-3671 | |
Visit this company's website |
Facility : Apodaca, Nuevo Léon, Mexico
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Switches/Sensors |
||||
9013F(A)(B)(CC)(DDD)(E)[G] | [1] | CLD 23 | MLTPL | |
[1] The following configurations are Certified: (A) - Mechanism type R - Reverse action S - Standard adjustable differential T - Non-adjustable differential Y - Higher HP with adjustable differential (B) - Enclosure type G - NEMA1 General Purpose Electrical Enclosure W - NEMA3R Outdoor Electrical Enclosure (CC) - Fluid connection type 1 - 1/8" NPSF internal threads 2, 12, 22, 32, 42, 52, 62, 72, 82, 92 - 1/4" NPSF internal 4 - Narrow Differential 8, 18, 28, 38, 48, 58, 68, 78, 88, 98 - 1/4" Flare 9, 19, 29, 39, 49, 59, 89, 99 - 1/4" NPT internal 10 - 1/4" Bayonet, barbed (DDD) - Pressure Regulation J15 - J99 (E) - Form (Optional) BP - Box pack for consumer products CP - Clam pack for consumer products C16 - Standard pack of 16 devices per box. Applies for product with Forms T. C20 - Standard pack of 20 devices per box. Applies for product with Forms M1, M3, M4, M5, and product without Forms M1, M3, M4, M5, T. C40 - Standard pack of 40 devices per box. Applies for product with Forms M1, M3, M4, M5. C50 - Standard pack of 50 devices per box. Applies for product without Forms M1, M3, M4, M5, T. C400 - Standard pack of 400 devices per box. Applies for product without Forms M1, M3, M4, M5, T. H - One normally open - one normally closed contact. Applies to FRG-2 Pole. M1 - Maintained manual cut-out lever (Auto-off). Applies to FSG, FYG. M3 - Momentarily manual cut-in lever (Auto-start). Applies to FSG2-59 only. M4 - Low pressure cut-off (auto-start-off). Operates at approximately 10 psig below cut-in and will turn off the pump. Applies to FSG and FYG. M5 - Maintained manual cut-in lever (auto-on). Applies to FRG2-59 only P - Pulsation plug - Type 2 & 9 only. Applies to FRG, FSG, FYG Q8 - Plastic flange (max temp 120°F, max pressure 80 psi). Applies to FSG, FYG, FRG. Available only in types FGS2, FYG2, FRG2, FSG*2, FYG*2, FRG*2. Applies to 1/4" NPSF internal only. T - 1/2" conduit bushing - 1/2" long thread - on left. Applies to all Type F. U - Slip-on connectors (load side terminals only). Applies to FSG FYG. U2 - Slip-on connectors (line and load terminals). Applies to FSG and FYG. Z22 - Black cover. Applies to FSG, FYG. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NOTE: NSF has not conducted production control audits at this facility. Product Listing is based on type testing [ISO/TEC Guide 2: 1996(E/F/R) 14.5]
Number of matching Manufacturers is 1
Number of matching Products is 1
Processing time was 0 seconds