NSF Product and Service Listings

These NSF Official Listings are current as of Saturday, August 24, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0032037&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
AMERICAN Flow Control 
1501 North 31st Avenue
Birmingham, AL 35207 
United States 
800-326-8051 
205-325-7856
Visit this company's website


Facility : Conway, AR

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Valves[1] [2] [3] [G]
American Flow Control Series 2500 Resilient Wedge Gate Valve (25YY) NRS 14" - 30" CLD 23 MLTPL
American Flow Control Series 2500 Resilient Wedge Gate Valve (25YY) OS&Y 14" - 24" CLD 23 MLTPL
American Flow Control Series 2500-1 Resilient Wedge Gate Valve (25XX-1) NRS 2" - 12" CLD 23 MLTPL
American Flow Control Series 2500-1 Resilient Wedge Gate Valve (25XX-1) OS&Y 2" - 12" CLD 23 MLTPL
American Flow Control Series 3500 Resilient Wedge Gate Valve NRS 4" - 12" CLD 23 MLTPL
American Flow Control Series 3500 Resilient Wedge Gate Valve OSY 4" - 12" CLD 23 MLTPL

[1] XX and YY refer to the size in inches.
[2] Certified for use in distribution systems only.
[3] 2500 series valves are certified with the following optional connection types:
    (A)   - ALPHA
    (AX)  - ALPHA XL
    (F)   - Flanged (ANSI Class 125)
    (F2)  - Flanged (ANSI Class 250 with raised face)
    (F3)  - Flanged (PN16 with raised face)
    (F4)  - Flanged (PN16 with flat face)
    (FB)  - Flanged (ANSI Class 250 with flat face)
    (FX)  - Flex Ring
    (MJ)  - Mechanical Joint
    (PO)  - Push-on
    (PVC) – PVC
    (RF)  - Flanged (ANSI Class 150 with raised face)
    (S)   - Threaded (NPT)
    (TM)  - Tapping flanged by mechanical joint
    (TYT) – Tyton
    
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



Facility : South St. Paul, MN

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fire Hydrants[1] [G]
AMERICAN Waterous Pacer Fire Hydrant (Model W67-250) 5 1/4" CLD 23 MLTPL
AMERICAN Waterous Pacer Fire Hydrant (Model W67-350) 5 1/4" CLD 23 MLTPL
AMERICAN Waterous Pacer Fire Hydrant (Model WB67-250) 5 1/4" CLD 23 MLTPL
AMERICAN Waterous Pacer Fire Hydrant (Model WB67-350) 5 1/4" CLD 23 MLTPL
AMERICAN Waterous Trend Fire Hydrant (Model WB77-1) 4 3/4" CLD 23 MLTPL
Sequoia Wet Barrel Hydrant PH 6" CLD 23 MLTPL
Sequoia Wet Barrel Hydrant PPH/PHH 6" CLD 23 MLTPL

[1] Trend and Pacer models are certified with the following optional end connections:
     - 4 inch mechanical joint
     - 6 inch mechanical joint
     - 6 inch mechanical joint for Dallas, Texas
     - 6 inch Class B mechanical joint
     - 8 inch mechanical joint
     - 6 inch flanged
     - 6 inch flanged with 2 inch NPT pipe plugs
     - 6 inch Tyton 
     - 6 inch plain end
     - 6 inch PVC
     - 6 inch vertical entry
     - 6 inch vertical entry for Traverse City TVC5
     - 6 inch ALPHA
     - 6 inch ALPHA XL
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Valves [G]
AMERICAN Waterous Series 6XX Swing Check Valves[2] [3] 3" - 12" CLD 23 MLTPL
American Flow Control Series 2500 Resilient Wedge Gate Valve (25YY) NRS[4] [5] [6] 14" - 30" CLD 23 MLTPL
American Flow Control Series 2500 Resilient Wedge Gate Valve (25YY) OS&Y[4] [5] [6] 14" - 24" CLD 23 MLTPL
American Flow Control Series 2500-1 Resilient Wedge Gate Valve (25XX-1) NRS[4] [5] [6] 2" - 12" CLD 23 MLTPL
American Flow Control Series 2500-1 Resilient Wedge Gate Valve (25XX-1) OS&Y[4] [5] [6] 2" - 12" CLD 23 MLTPL
American Flow Control Series 3500 Resilient Wedge Gate Valve (35YY) NRS[4] [5] [6] 4" - 12" CLD 23 MLTPL
American Flow Control Series 3500 Resilient Wedge Gate Valve (35YY) OSY[4] [5] [6] 4" - 12" CLD 23 MLTPL
CV 2203 3" CLD 23 MLTPL
CV 2210 10" CLD 23 MLTPL
CV 2212 12" CLD 23 MLTPL
CV2204 [7] 4" CLD 23 MLTPL
CV2206[7] 6" CLD 23 MLTPL
CV2208[7] 8" CLD 23 MLTPL

[2] XX refers to size and may be 03, 04, 06, 08, 10 or 12.
[3] Certified for standard and outside shaft models.
[4] XX and YY refers to the size in inches.
[5] Certified for use in distribution systems only.
[6] 2500 and 3500 series valves are certified with the following optional connection types:
    (A)   - ALPHA
    (AX)  - ALPHA XL
    (F)   - Flanged (ANSI Class 125)
    (F2)  - Flanged (ANSI Class 250 with raised face)
    (F3)  - Flanged (PN16 with raised face)
    (F4)  - Flanged (PN16 with flat face)
    (FB)  - Flanged (ANSI Class 250 with flat face)
    (FX)  - Flex Ring
    (MJ)  - Mechanical Joint
    (PO)  - Push-on
    (PVC) – PVC
    (RF)  - Flanged (ANSI Class 150 with raised face)
    (S)   - Threaded (NPT)
    (TM)  - Tapping flanged by mechanical joint
    (TYT) – Tyton
[7] Certified for standard and outside shaft models.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



Facility : Beaumont, TX

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Fire Hydrants[1] [2] [G]
American-Darling B-62-B-5 Fire Hydrant 5.25" CLD 23 MLTPL
American-Darling B-62-B-BB-5 Fire Hydrant 5.25" CLD 23 MLTPL
American-Darling B-84-B-5 Fire Hydrant 5.25", 6" CLD 23 MLTPL
American-Darling B-84-B-BB-5 Fire Hydrant 6" CLD 23 MLTPL
American-Darling Mark 73-5 (MK73-5) Fire Hydrant 4.5" CLD 23 MLTPL

[1] Certification does not include any connection gaskets.
[2] All model hydrants are certified with the following optional connection types:
    - ALPHA
    - ALPHA XL
    - Flanged 
    - Flanged (ANSI Class 250 with raised face)
    - Flanged (ANSI Class 250 with flat face)
    - Mechanical Joint
    - Mechanical Joint Plain End
    - Push-on
    - Tyton
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Valves [G]
American Flow Control Series 2100 Resilient Seat Swing Check Valve (21XX)[3] [4] [5] 3" - 16" CLD 23 MLTPL
American Flow Control Series 2500 Resilient Wedge Gate Valve (25YY) NRS[6] [7] 14" - 66" CLD 23 MLTPL
American Flow Control Series 2500 Resilient Wedge Gate Valve (25YY) OS&Y[6] [7] 14" - 24" CLD 23 MLTPL
American Flow Control Series 2500-1 Resilient Wedge Gate Valve (25XX-1) NRS[6] [7] 4" - 12" CLD 23 MLTPL
American Flow Control Series 3500 Resilient Wedge Gate Valve (35YY) NRS[6] [7] 4" - 12" CLD 23 MLTPL
Swing Check Valve - Series 52 SC[8] 3" - 16" CLD 23 MLTPL

[3] XX refers to the size of the valve in inches and may be 03, 04, 06, 08, 10, 12, 14, or
    16.
[4] Certified for use in distribution systems only.
[5] 2100 series check valves are certified with the following optional connection types:
    - Flanged 
    - Mechanical Joint
    - Mechanical Joint Plain End
[6] XX and YY refer to the size in inches.
[7] 2500 and 3500 series valves are certified with the following optional connection types:
    (A)	  - ALPHA
    (AX)  - ALPHA XL
    (F)   - Flanged (ANSI Class 125)
    (F2)  - Flanged (ANSI Class 250 with raised face)
    (F3)  - Flanged (PN16 with raised face)
    (F4)  - Flanged (PN16 with flat face)
    (FB)  - Flanged (ANSI Class 250 with flat face)
    (FX)  - Flex Ring
    (MJ)  - Mechanical Joint
    (PO)  - Push-on
    (PVC) – PVC
    (RF)  - Flanged (ANSI Class 150 with raised face)
    (S)   - Threaded (NPT)
    (TM)  - Tapping flanged by mechanical joint
    (TYT) – Tyton
[8] The Swing Check Valve - Series 52 SC may use a "lever and weight" or "lever and spring"
    option.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Number of matching Manufacturers is 1
Number of matching Products is 37
Processing time was 0 seconds