NSF Product and Service Listings
These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0048720&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
MCM Co., Ltd. | |
486, Jingwang-ro, Iwol-myeon | |
Jincheon-gun, Chungcheongbukdo 365-842 | |
Korea, Republic of | |
82 43 531 7021 |
Facility : Chungcheongbukdo, Republic of Korea
Mechanical Plumbing Devices
Trade Designation | ||||
Solenoid Valves[1] [G] |
||||
(W)(#)-(S)(W)(#)(A)-(###)[Q] | ||||
(W)(#)-(S)(W)(#)B-(###)[Q] | ||||
(WE)(#)-(S)(W)(#)B-(###)[Q] | ||||
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per Section 9.5.1.1 of NSF/ANSI/CAN 61. |
||||
[1] Valves are named as follows: Valve Type W - Internal Valve WE - External Valve (#) Valve Voltage (1-9) 1 - AC 110V 2 - AC 220V 3 - DC 12 4 - DC 24 Part number from 1 to 9 by the voltage specification. (S) Customer (A-Z) S - Customer Samsung L - Customer LG G - Glober Customer The part number will be named upon the customer's request. (W) Connect Type W - WIRE Type T - TERMINAL Type (#) Valve Voltage (1-9) 1 - AC 110V 2 - AC 220V 3 - DC 12 4 - DC 24 Part number from 1 to 9 by the voltage specification. (S) Customer (A-Z) S - Customer Samsung L - Customer LG G - Glober Customer The part number will be named upon the customer's request. (W) Connect Type W - WIRE Type T - TERMINAL Type (#) Bobbon Count (1-9) 1 - Bobbin 1ea 2 - Bobbin 2ea 3 - Bobbin 3ea Part number by quantity of the bobbin. (A) Valve Inlet Type (A-Z) A - Direct Tube Connect Type B - Insert Connect Type C - Fitting Connect Type D - Tank Direct Connect Type (###) Valve Number ### - 1-999 Valve Number Part number from 1-999 for non-wet valve parts. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Pipes and Related Products
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Tubing[3] [G] |
||||
TBE Tubing | 1/4" | CLD 23 | PE | |
TBLL14B | 1/4" | CLD 23 | PE | |
TBLL14G | 1/4" | CLD 23 | PE | |
TBLL14N | 1/4" | CLD 23 | PE | |
TBLL14O | 1/4" | CLD 23 | PE | |
TBLL14W | 1/4" | CLD 23 | PE | |
TBLL38B | 3/8" | CLD 23 | PE | |
TBLL38G | 3/8" | CLD 23 | PE | |
TBLL38N | 3/8" | CLD 23 | PE | |
TBLL38O | 3/8" | CLD 23 | PE | |
TBLL38W | 3/8" | CLD 23 | PE | |
TBLL51B | 5/16" | CLD 23 | PE | |
TBLL51G | 5/16" | CLD 23 | PE | |
TBLL51N | 5/16" | CLD 23 | PE | |
TBLL51O | 5/16" | CLD 23 | PE | |
TBLL51W | 5/16" | CLD 23 | PE | |
TBPE14B | 1/4" | C. HOT | PERT | |
TBPE14G | 1/4" | C. HOT | PERT | |
TBPE14N | 1/4" | C. HOT | PERT | |
TBPE14O | 1/4" | C. HOT | PERT | |
TBPE14W | 1/4" | C. HOT | PERT | |
TBPE31W | 3/16" | C. HOT | PERT | |
TBPE51B | 5/16" | C. HOT | PERT | |
TBPE51G | 5/16" | C. HOT | PERT | |
TBPE51N | 5/16" | C. HOT | PERT | |
TBPE51O | 5/16" | C. HOT | PERT | |
TBPE51W | 5/16" | C. HOT | PERT | |
[3] N, W, B, G, and O in the trade name indicate Natural, White, Blue, Gray, and Orange respectively. Equivalent metric sizes are listed as well: 3/16" - 4.76 mm 1/4" - 6.35 mm 3/8" - 9.52 mm 5/16" - 7.93 mm [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||
Fittings[1] [G] |
||||
2 Way Divider/DTA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Bulkhead/BHA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
CO2 Gas Valve/GVA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Cross/CRA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
End Stop/ESA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Equal Elbow(Hot Water)/LEK(XX)(XX)(Y)(ZZ) | [2] | C. HOT | MLTPL | |
Equal Elbow/LEA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Equal STR(Hot Water)/SEK(XX)(XX)(Y)(ZZ) | [2] | C. HOT | MLTPL | |
Equal STR/SEA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Equal Tee(Hot Water)/TEK(XX)(XX)(Y)(ZZ) | [2] | C. HOT | MLTPL | |
Equal Tee/TEA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
F1 Stem Elbow/FLA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Female Adapter/FAA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Hook Elbow/HLA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Hook Stem/F11-207-1 | [2] | D. HOT | MLTPL | |
Hook Stem/F11-257-0 | [2] | D. HOT | MLTPL | |
Hook Stem/F11-408-0 | [2] | C. HOT | MLTPL | |
Hook Tee/HTA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
M.Male Elbow/LMM(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Male Adapter/MAA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Male Adapter/MBA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Male Elbow/LMA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Plug/PGA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Reducer/RDA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Reducing STR/SRA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Reducing Tee(Hot Water)/TRK(XX)(XX)(Y)(ZZ) | [2] | C. HOT | MLTPL | |
Reducing Tee/TRA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Stem Elbow(Hot Water)/LSK(XX)(XX)(Y)(ZZ) | [2] | C. HOT | MLTPL | |
Stem Elbow/LSA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Stem Straight/SSA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
T-Fitting/TSA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Tube to Hose Elbow/LHA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
Tube to Hose STR/SHA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
U-Bend/UBA(XX)(XX)(Y)(ZZ) | [2] | D. HOT | MLTPL | |
[1] (XX) refers to the size of tube, nipple or tread; 12(1/2"), 14(1/4"), 51(5/16"), 38(3/8"), 31(3/16"), 34(3/4"), 71(7/16") [2] (YY) refers to a color of fitting; G - Gray, W - White, N - Natural (ZZ) refers to a color of collet; 01 (same color with body), 02 (red), 03 (blue) are given when all of collets' color are identical/collets with different colors are used, following numbers are given; 1 (Gray), 2 (Red), and 3 (Blue) [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 64