NSF Product and Service Listings
These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0234983&Standard=061&
NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Neptune Benson Inc. | |
334 Knight Street | |
Suite 3100 | |
Warwick, RI 02886 | |
United States | |
303-425-4242 | |
Visit this company's website |
Facility : Holland, MI
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Filtration Devices/Components[1] [G] |
||||
LPV-250-(Y)-(Z)[2] | 3" - 4" | CLD 23 | MLTPL | |
LPV-500-(Y)-(Z)[2] | 4" - 6" | CLD 23 | MLTPL | |
V-200(X)-(Y)[3] | 3" | CLD 23 | MLTPL | |
V-250-(Y)-(Z)[4] | 3" - 4" | CLD 23 | MLTPL | |
V-500-(Y)-(Z)[4] | 4" - 6" | CLD 23 | MLTPL | |
V-1000-(Y)-(Z)[4] | 6" - 8" | CLD 23 | MLTPL | |
V-1500-(Y)-(Z)[4] | 8" - 10" | CLD 23 | MLTPL | |
V-2000-(Y)-(Z)[4] | 10" - 14" | CLD 23 | MLTPL | |
V-3VERT-(XX)[5] | 8" - 14" | CLD 23 | MLTPL | |
V-3500-(XX)[5] | 8" - 20" | CLD 23 | MLTPL | |
V-8000-(XX)[5] | 14" - 36" | CLD 23 | MLTPL | |
[1] Certified for a minimum daily flow of 190,784 liters. [2] LPV - Low Pressure V-Series Filter, (Y) Denotes connection size, (Z) Connection type (i.e. flange, groove, DIN flange, JIS flange) [3] (X) Refers to the configuration and may be P or ST (Y) Refers to the connection type and may be 3N (3" NPT), 3B (3" BSP), 3G (3" groove) or 3F (3" Flanged) [4] (Y) Denotes connection size, (Z) Connection type (i.e. flange, groove, DIN flange, JIS flange) [5] (XX) denotes the connection flange size. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 11
Processing time was 0 seconds