NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Hydron Membrane Technology 
8630 Rochester Avenue
Rancho Cucamonga, CA 91730 
United States 
909-527-6996
Visit this company's website


Facility : 3A

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Reverse Osmosis Element[1] [2] [3] [4]
BW-4040 4" x 40" CLD 23 MLTPL
BW-8040 8" x 40" CLD 23 MLTPL
HFR-4040 4" x 40" CLD 23 MLTPL
HFR-8040 8" x 40" CLD 23 MLTPL
HLE-4040 4" x 40" CLD 23 MLTPL
HLP-2521 2 1/2" x 21" CLD 23 MLTPL
HLP-2540 2 1/2" x 40" CLD 23 MLTPL
HLP-4021 4" x 21" CLD 23 MLTPL
HLP-4040 4" x 40" CLD 23 MLTPL
HLP-8040 8" x 40" CLD 23 MLTPL
HLP2-4021 4" x 21" CLD 23 MLTPL
HLP2-4040 4" x 40" CLD 23 MLTPL
HLP2-8040 8" x 40" CLD 23 MLTPL
HLP3-4021 4" x 21" CLD 23 MLTPL
HLP3-4040 4" x 40" CLD 23 MLTPL
HLP3-8040 8" x 40" CLD 23 MLTPL
OR-4040 4" x 40" CLD 23 MLTPL
OR-8040 8" x 40" CLD 23 MLTPL
SW-2521 2 1/2" x 21" CLD 23 MLTPL
SW-2540 2 1/2" x 40" CLD 23 MLTPL
SW-4021 4" x 21" CLD 23 MLTPL
SW-4040 4" x 40" CLD 23 MLTPL
SW-8040 8" x 40" CLD 23 MLTPL
SW2-8040 8" x 40" CLD 23 MLTPL

[1] Certified for both wet and dry elements.
[2] All elements (wet and dry) require a pre-service flush:
    Fill the RO pressure vessel with qualified pretreated water. The feed water pressure
    shall be restricted to 50 psi and the flow rate shall be equal to 16 GPM (gallons per
    minute). The rejected water and product water shall be discharged completely. The
    membrane element shall be flushed for 6 hours. No antiscalant shall be
    added in flushing.
[3] The 2521, 2540 and 4021 elements are evaluated for point-of-entry end uses.
[4] 4040 and 8040 elements are Certified for minimum flow rates of:
    4040 size - 8,000 L/day
    8040 size - 30,000 L/day


Number of matching Manufacturers is 1
Number of matching Products is 24