NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
Honeywell International Inc. | |
315 East Stephenson Street | |
Freeport, IL 61032 | |
United States | |
815-618-6279 |
Facility : Chihuahua, Mexico
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Transmitters/Gauges[1] [G] |
||||
Media Isolate Pressure Sensor with 1/4" 45° Female Shrader Port | 1/4" | CLD 23 | MLTPL | |
Media Isolate Pressure Sensor with 1/4-18 NPT Port | 1/4" | CLD 23 | MLTPL | |
Media Isolate Pressure Sensor with 1/8-27 NPT Port | 1/8" | CLD 23 | MLTPL | |
Media Isolate Pressure Sensor with G1/4 A Port | 1/4" | CLD 23 | MLTPL | |
Media Isolate Pressure Sensor with M12 X 1.5 Port | 12 mm | CLD 23 | MLTPL | |
[1] MIPS Pressure Transducer Naming MIP-X-XX-X-X-XXXX-X-XX-X First X - Connector Type A - Metri-Pack 150 Series C – DIN-C standard D – Digital Output with cable E - Cable, 1.0 m length F - Cable, 2.0 m length G – Cable harness for CH output transfer function 3m length H – Cable harness for CH output transfer function 5m length K – Cable, 0.5m length Second and Third X - Pressure Connection F1 - 1/4-in 45-degree Female Schrader G1 - G 1/4 A -G G2 - G 1/4 A -L G3 - G 1/8-28 BSSP M1 - M12 x 1.5 M3 – M14 x 1.5 N1 - 1/4-18 NPT N2 - 1/8-27 NPT R1 – R1/4-19 BSPT R2 – R1/8-28 BSPT S1 – 9/16-18 UNF S2 – 7/16-20 UNF S3 – 3/8-24 UNF Fourth and Fifth X - Not Defined Sixth thru Ninth X - Four Digit Alpha-Numeric Code For Pressure Range (bar or PSI) Tenth X - Pressure Reference A - Absolute S - Sealed Gage (only available at or above 100 psi or 8 bar) Eleventh and Twelfth X - Output Type AA – Ratiometric: 5.0V Vs: 10% to 90% AD – Ratiometric: 5.0 Vs: 10% to 90% Vs CH – Current: 4mA to 20mA BC – Regulated: 1Vdc to 6Vdc BD – Regulated: 0.25Vdc to 10.25Vdc BE – Regulated: 0.5Vdc to 4.5Vdc BG – Regulated: 1Vdc to 5Vdc DA – IC Digital output DB – SPI Digital output Thirteenth X – Special X – No selection L – Load dump protection (for regulated output with cable harness only) [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 5
Processing time was 0 seconds