NSF Product and Service Listings

These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0550408&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
MANN+HUMMEL Water & Fluid Solutions GmbH 
Kasteler Strasse 45
65203 Wiesbaden 
Germany 
49 0 611 9 62 6001
Visit this company's website


Facility : Fano (PU), Italy

Mechanical Devices

    Water Water
    Contact Contact
Trade Designation Size Temp Material

Reverse Osmosis Element[1] [2] [3]
4021-NF7[4] 4" x 21" CLD 23 MLTPL
4021-NF9[4] 4" x 21" CLD 23 MLTPL
4021-SWH[4] 4" x 21" CLD 23 MLTPL
4021-SWL[4] 4" x 21" CLD 23 MLTPL
4040-BW[4] 4" x 40" CLD 23 MLTPL
4040-FR[4] 4" x 40" CLD 23 MLTPL
4040-HRLE[4] 4" X 40" CLD 23 MLTPL
4040-LE[4] 4" x 40" CLD 23 MLTPL
4040-LE+[4] 4" X 40" CLD 23 MLTPL
4040-NF7[4] 4" x 40" CLD 23 MLTPL
4040-NF7+[4] 4" x 40" CLD 23 MLTPL
4040-NF9[4] 4" x 40" CLD 23 MLTPL
4040-NF9+[4] 4" x 40" CLD 23 MLTPL
4040-SWH[4] 4" x 40" CLD 23 MLTPL
4040-SWL[4] 4" x 40" CLD 23 MLTPL
4040-TW[4] 4" X 40" CLD 23 MLTPL
4040-ULE [4] 4" X 40" CLD 23 MLTPL
4040-ULE+[4] 4" X 40" CLD 23 MLTPL
4040-XLE[4] 4" X 40" CLD 23 MLTPL
4040-XLE+[4] 4" X 40" CLD 23 MLTPL
4040-XLE/34[5] 8" X 40" CLD 23 MLTPL
4040-XRLE[4] 4" X 40" CLD 23 MLTPL
4040-XRLE+[4] 4" X 40" CLD 23 MLTPL
4040-XRLE/34[4] 4" X 40" CLD 23 MLTPL
8040-BW-365[5] 8" x 40" CLD 23 MLTPL
8040-BW-400[5] 8" x 40" CLD 23 MLTPL
8040-BW-400/34[4] 8" x 40" CLD 23 MLTPL
8040-BW-440[4] 8" x 40" CLD 23 MLTPL
8040-FR-365[4] 8" x 40" CLD 23 MLTPL
8040-FR-400/34[4] 8" x 40" CLD 23 MLTPL
8040-HRLE-400[5] 8" x 40" CLD 23 MLTPL
8040-HRLE-400/34[5] 8" x 40" CLD 23 MLTPL
8040-HRLE-440[5] 8" x 40" CLD 23 MLTPL
8040-LE-400[5] 8" x 40" CLD 23 MLTPL
8040-LE-400/34[5] 8" x 40" CLD 23 MLTPL
8040-LE-440[5] 8" x 40" CLD 23 MLTPL
8040-NF7-400[5] 8" x 40" CLD 23 MLTPL
8040-NF9-400 [5] 8" x 40" CLD 23 MLTPL
8040-SWH-400[4] 8" x 40" CLD 23 MLTPL
8040-SWH-440[4] 8" x 40" CLD 23 MLTPL
8040-SWL-400[4] 8" x 40" CLD 23 MLTPL
8040-SWL-440[4] 8" x 40" CLD 23 MLTPL
8040-ULE-400[5] 8" x 40" CLD 23 MLTPL
8040-ULE-440[5] 8" x 40" CLD 23 MLTPL
8040-XLE-400[5] 8" x 40" CLD 23 MLTPL
8040-XLE-400/34[4] 8" x 40" CLD 23 MLTPL
8040-XLE-440[5] 8" x 40" CLD 23 MLTPL
8040-XRLE-400[5] 8" x 40" CLD 23 MLTPL
8040-XRLE-400/34[5] 8" x 40" CLD 23 MLTPL
8040-XRLE-440[5] 8" x 40" CLD 23 MLTPL

[1] Sizes indicated are expressed as diameter x length.
[2] Certified for a minimum permeate (product water) flow of 1,191 L/day.
[3] Only products bearing the NSF Mark on the product, product packaging, and/or
    documentation shipped with the product are Certified.
[4] Certified elements must be flushed of preservative in the field for a minimum of 2 hours
    at the following parameters:
    8040-BW-440 11555 l/h at 225 psi	
    8040-BW-400/34 11555 l/h at 225 psi	
    8040-FR-365 12000 l/h at 225 psi	
    8040-FR-400/34 12000 l/h at 225 psi	
    4040-BW 900 l/h at 225 psi	
    4040-FR 1000 l/h at 225 psi	
    4040-LE 1000 l/h at 150 psi	
    4040-XRLE/34 1000 l/h at 150 psi	
    4040-XLE 1000 l/h at 150 psi	
    8040-XLE-400/34 12,610 l/h at 100 psi	
    4040-TW 900 l/h at 225 psi	
    4040-LE+ 1000 l/h at 150 psi	
    4040-XRLE+ 1000 l/h at 150 psi	
    4040-HRLE 1000 l/h at 150 psi	
    4040-XRLE 1000 l/h at 150 psi	
    4040-ULE+ 1000 l/h at 150 psi	
    4040-ULE 1000 l/h at 150 psi	
    4040-XLE+ 1000 l/h at 150 psi
    4021-SWL, 4040-SWL, 4021-SWH and 4040-SWH at 1500 l/h at 500 psi
    8040-SEH-400 and 8040-SWH-440 at 12000 l/h at 500 psi
    8040-SWL-400 and 8040-SWL-440 at 15000 l/h at 500 psi
    4021-NF7, 4040-NF7, 4040-NF7+, 4021-NF9, 4040-NF9, 4040-NF9+ at 1000 l/h at 100 psi
[5] Certified elements must be flushed of preservative in the field for a minimum of 1 hour
    at the following parameters:
    8040-BW-365 10,530 l/hr at 225 psi	
    8040-BW-400 11,555 l/hr at 225 psi	
    8040-LE-400 12,610 l/h at 150 psi	
    8040-LE-440 13,890 l/h at 150 psi	
    8040-LE-400/34 12,000 l/ hr at 150 psi	
    8040-XLE-400 12,610 l/h at 100 psi	
    8040-XLE-440 13,890 l/h at 100 psi	
    4040-XLE/34 1000 l/h at 150 psi	
    8040-HRLE-400 9,745 l/h at 150 psi	
    8040-XRLE-400 9,745 l/h at 150 psi	
    8040-HRLE-440 12,610 l/h at 150 psi	
    8040-XRLE-440 12,610 l/h at 150 psi	
    8040-HRLE-400/34 12,000 l/ hr at 150 psi	
    8040-XRLE-400/34 12,000 l/ hr at 150 psi	
    8040-ULE-400 12,610 l/h at 150 psi	
    8040-ULE-440 13,890 l/h at 150 psi
    8040-NF7-400 and 8040-NF9-400 at 12000 l/h at 100 psi 


Number of matching Manufacturers is 1
Number of matching Products is 50
Processing time was 0 seconds