NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects
Drinking Water System Components - Health Effects
NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.
AROMEM Pte. Ltd. | |
Building 888, Luzhi Evenue, Luzhi Town | |
Wuzhong District, Suzhou | |
Jiangsu 215126 | |
China | |
86 512 6270 0495 |
Facility : Jiangsu, China
Mechanical Devices
Water | Water | |||
Contact | Contact | |||
Trade Designation | Size | Temp | Material | |
Reverse Osmosis Element[1] [2] [3] |
||||
SURO BW-4040 | 4" x 40" | CLD 23 | MLTPL | |
SURO BW-4040FR | 4" x 40" | CLD 23 | MLTPL | |
SURO BW-8040 | 8" x 40" | CLD 23 | MLTPL | |
SURO BW-8040FR | 8" x 40" | CLD 23 | MLTPL | |
SURO NF30-4040 | 4" x 40" | CLD 23 | MLTPL | |
SURO NF30-8040 | 8" x 40" | CLD 23 | MLTPL | |
SURO NF90-4040 | 4" x 40" | CLD 23 | MLTPL | |
SURO NF90-8040 | 8" x 40" | CLD 23 | MLTPL | |
SURO ULP-4040 | 4" x 40" | CLD 23 | MLTPL | |
SURO ULP-4040HR | 4" x 40" | CLD 23 | MLTPL | |
SURO ULP-8040 | 8" x 40" | CLD 23 | MLTPL | |
SURO ULP-8040HR | 8" x 40" | CLD 23 | MLTPL | |
SURO XLP-4040 | 4" x 40" | CLD 23 | MLTPL | |
SURO XLP-8040 | 8" x 40" | CLD 23 | MLTPL | |
[1] Certified for the following minimum daily flow rates: SURO XLP-8040 is certified for a minimum flow of 9000 gallons per day. SURO XLP-4040 and SURO BW-4040FR are certified for a minimum flow of 2300 gallons per day. SURO ULP-8040 is certified for a minimum flow of 12000 gallons per day. SURO ULP-4040 is certified for a minimum flow of 2600 gallons per day. SURO ULP-8040HR and SURO BW-8040 are certified for a minimum flow of 10500 gallons per day. SURO ULP-4040HR is certified for a minimum flow of 2400 gallons per day. SURO BW-4040 is certified for a minimum flow of 2500 gallons per day. SURO BW-8040FR is certified for a minimum flow of 9500 gallons per day. SURO NF30-8040 is certified for a minimum flow of 14000 gallons per day. SURO NF30-4040 is certified for a minimum flow of 3200 gallons per day. SURO NF90-8040 is certified for a minimum flow of 14500 gallons per day. SURO NF90-4040 is certified for a minimum flow of 3500 gallons per day. [2] SURO XLP-8040 requires a 2 hour flush at a flow rate of 6.25 gallons per minute (gpm) with tap water. SURO XLP-4040 and SURO BW-4040FR require a 2 hour flush at a flow rate of 1.597 gallons per minute (gpm) with tap water. SURO ULP-8040 requires a 2 hour flush at a flow rate of 8.33 gallons per minute (gpm) with tap water. SURO ULP-4040 requires a 2 hour flush at a flow rate of 1.805 gallons per minute (gpm) with tap water. SURO ULP-8040HR and SURO BW-8040 require a 2 hour flush at a flow rate of 7.291 gallons per minute (gpm) with tap water. SURO BW-4040 requires a 2 hour flush at a flow rate of 1.736 gallons per minute (gpm) with tap water. SURO BW-8040FR requires a 2 hour flush at a flow rate of 6.597gallons per minute (gpm) with tap water. SURO NF30-8040 requires a 2 hour flush at a flow rate of 9.722 gallons per minute (gpm) with tap water. SURO NF30-4040 requires a 2 hour flush at a flow rate of 2.222 gallons per minute (gpm) with tap water. SURO NF90-8040 requires a 2 hour flush at a flow rate of 10.069 gallons per minute (gpm) with tap water. SURO NF90-4040 requires a 2 hour flush at a flow rate of 2.431 gallons per minute (gpm) with tap water. [3] Naming Convention: SURO - The abbreviation of the company name ULP - Ultra Low Pressure XLP - Extremely Low Pressure FR - Fouling Resistance and can be used to High Salt water BW - Bitter water, which can be used for bitter water 8040/4040 - Size |
Number of matching Manufacturers is 1