NSF Product and Service Listings

These NSF Official Listings are current as of Monday, July 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0762199&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
NBR Equipment 
10 Abeel Road
Cranbury, NJ 08512 
United States 
609-642-8389


Facility : Tianjin, China

Mechanical Plumbing Devices

Trade Designation      

Commercial Faucets[G] [Q]
P2D1-PU      
P2W8-PU      
P2W8S12-PU      
P3W8-PU      
P3W8S12-PU      

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

Faucet Handspray Head Assembly[G] [Q]
P6V1      

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

Faucet Spouts[G] [Q]
P6DS3G      
P6S(3G-8G)      
P6S(6-16)      
P6WS3G      

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

Faucet, Miscellaneous Faucet Components[G] [Q]
P1D4      
P1D8      
P1W4      
P1W4SL      
P1W8      
P2D4      
P2D8      
P2W8      
P3D4      
P3D8      
P3W4      
P3W4SL      
P3W8      
P4A      
P5F1      
P5F2      
P5K1      
P5K2      
P6D      
P6W      

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

Faucets[G] [Q]
P5F1-WS3G      
P5F2-WS3G      
P5K1-WS3G      
P5K2-DS3G      
P5K2-WS3G      

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.

Flexible Plumbing Connectors[G] [Q]
P6H44      

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    
[Q] This product meets the reduced Q test statistic criteria of 1 µg or 0.5 µg for lead per
    Section 9.5.1.1 of NSF/ANSI/CAN 61.


Number of matching Manufacturers is 1
Number of matching Products is 36
Processing time was 0 seconds