NSF/ANSI 40
Residential Wastewater Treatment Systems
Residential Wastewater Treatment Systems
| Infiltrator Water Technologies, LLC (formerly Presby Environmental, Inc.) | ![]() |
| 4 Business Park Road | |
| Old Saybrook, CT 06475 | |
| United States | |
| 800-473-5298 | |
| 603-837-3826 | |
| Visit this company's website |
Facility : Whitefield, NH
| Model Number | Rated Capacity Gallons/Day |
Classification | ||
|
Advanced Enviro-Septic® Treatment System[1] [2] [3] |
||||
| AES-CTD-450 | 450 | Class I | ||
| AES-CTD-600 | 600 | Class I | ||
| AES-CTD-750 | 750 | Class I | ||
| AES-CTD-900 | 900 | Class I | ||
| AES-CTD-1050 | 1050 | Class I | ||
| AES-CTD-1200 | 1200 | Class I | ||
| AES-CTD-1350 | 1350 | Class I | ||
| AES-CTD-1500 | 1500 | Class I | ||
| AES-SPD-450 | 450 | Class I | ||
| AES-SPD-600 | 600 | Class I | ||
| AES-SPD-750 | 750 | Class I | ||
| AES-SPD-900 | 900 | Class I | ||
| AES-SPD-1050 | 1050 | Class I | ||
| AES-SPD-1200 | 1200 | Class I | ||
| AES-SPD-1350 | 1350 | Class I | ||
| AES-SPD-1500 | 1500 | Class I | ||
[1] Prefix CTD denotes bottomless discharge. Prefix SPD denotes single point discharge.
Prefix SS denotes Simple Septic®.
[2] Table A, Minimum Sizing and Dimensions
NSF 40 Class I Certified Advanced Enviro-Septic® Models, Simple
Septic®, & Enviro-Septic® Models
Model Number Design Daily Minimum Minimum Septic
Septic Flow Total Pipe Tank Size
Length (ft.) (gal.)
XX-SPD 450 & XX-CTD 450 450 150 1000
XX-SPD 600 & XX-CTD 600 600 200 1200
XX-SPD 750 & XX-CTD 750 750 250 1500
XX-SPD 900 & XX-CTD 900 900 300 1800
XX-SPD 1050 & XX-CTD 1050 1050 350 2100
XX-SPD 1200 & XX-CTD 1200 1200 400 2400
XX-SPD 1350 & XX-CTD 1350 1350 450 2700
XX-SPD 1500 & XX-CTD 1500 1500 500 3000
Maximum loading of 3.0 gallons per linear foot of AES, SS or ES pipe.
Minimum spacing of pipe rows – eighteen inches (18") on center (i.e. minimum one-half
foot (6") of system sand between pipe rows).
All models include 6" of system sand below pipes for treatment.
[3] While the treatment system includes design specifications similar to a dispersal field,
certification does NOT include management methods for the treated effluent discharged
from the system.
|
||||
|
Simple Septic® Treatment System[1] [2] [3] |
||||
| SS-SPD 450 | 450 | Class I | ||
| SS-SPD 600 | 600 | Class I | ||
| SS-SPD 750 | 750 | Class I | ||
| SS-SPD 900 | 900 | Class I | ||
| SS-SPD 1050 | 1050 | Class I | ||
| SS-SPD 1200 | 1200 | Class I | ||
| SS-SPD 1350 | 1350 | Class I | ||
| SS-SPD 1500 | 1500 | Class I | ||
| SS-CTD 450 | 450 | Class I | ||
| SS-CTD 600 | 600 | Class I | ||
| SS-CTD 750 | 750 | Class I | ||
| SS-CTD 900 | 900 | Class I | ||
| SS-CTD 1050 | 1050 | Class I | ||
| SS-CTD 1200 | 1200 | Class I | ||
| SS-CTD 1350 | 1350 | Class I | ||
| SS-CTD 1500 | 1500 | Class I | ||
[1] Prefix CTD denotes bottomless discharge. Prefix SPD denotes single point discharge.
Prefix SS denotes Simple Septic®.
[2] Table A, Minimum Sizing and Dimensions
NSF 40 Class I Certified Advanced Enviro-Septic® Models, Simple
Septic®, & Enviro-Septic® Models
Model Number Design Daily Minimum Minimum Septic
Septic Flow Total Pipe Tank Size
Length (ft.) (gal.)
XX-SPD 450 & XX-CTD 450 450 150 1000
XX-SPD 600 & XX-CTD 600 600 200 1200
XX-SPD 750 & XX-CTD 750 750 250 1500
XX-SPD 900 & XX-CTD 900 900 300 1800
XX-SPD 1050 & XX-CTD 1050 1050 350 2100
XX-SPD 1200 & XX-CTD 1200 1200 400 2400
XX-SPD 1350 & XX-CTD 1350 1350 450 2700
XX-SPD 1500 & XX-CTD 1500 1500 500 3000
Maximum loading of 3.0 gallons per linear foot of AES, SS or ES pipe.
Minimum spacing of pipe rows – eighteen inches (18") on center (i.e. minimum one-half
foot (6") of system sand between pipe rows).
All models include 6" of system sand below pipes for treatment.
[3] While the treatment system includes design specifications similar to a dispersal field,
certification does NOT include management methods for the treated effluent discharged
from the system.
|
||||
|
Enviro-Septic® Treatment System[1] [2] [3] |
||||
| ES-CTD-450 | 450 | Class I | ||
| ES-CTD-600 | 600 | Class I | ||
| ES-CTD-750 | 750 | Class I | ||
| ES-CTD-900 | 900 | Class I | ||
| ES-CTD-1050 | 1050 | Class I | ||
| ES-CTD-1200 | 1200 | Class I | ||
| ES-CTD-1350 | 1350 | Class I | ||
| ES-CTD-1500 | 1500 | Class I | ||
| ES-SPD-450 | 450 | Class I | ||
| ES-SPD-600 | 600 | Class I | ||
| ES-SPD-750 | 750 | Class I | ||
| ES-SPD-900 | 900 | Class I | ||
| ES-SPD-1050 | 1050 | Class I | ||
| ES-SPD-1200 | 1200 | Class I | ||
| ES-SPD-1350 | 1350 | Class I | ||
| ES-SPD-1500 | 1500 | Class I | ||
[1] Prefix CTD denotes bottomless discharge. Prefix SPD denotes single point discharge.
Prefix SS denotes Simple Septic®.
[2] Table A, Minimum Sizing and Dimensions
NSF 40 Class I Certified Advanced Enviro-Septic® Models, Simple
Septic®, & Enviro-Septic® Models
Model Number Design Daily Minimum Minimum Septic
Septic Flow Total Pipe Tank Size
Length (ft.) (gal.)
XX-SPD 450 & XX-CTD 450 450 150 1000
XX-SPD 600 & XX-CTD 600 600 200 1200
XX-SPD 750 & XX-CTD 750 750 250 1500
XX-SPD 900 & XX-CTD 900 900 300 1800
XX-SPD 1050 & XX-CTD 1050 1050 350 2100
XX-SPD 1200 & XX-CTD 1200 1200 400 2400
XX-SPD 1350 & XX-CTD 1350 1350 450 2700
XX-SPD 1500 & XX-CTD 1500 1500 500 3000
Maximum loading of 3.0 gallons per linear foot of AES, SS or ES pipe.
Minimum spacing of pipe rows – eighteen inches (18") on center (i.e. minimum one-half
foot (6") of system sand between pipe rows).
All models include 6" of system sand below pipes for treatment.
[3] While the treatment system includes design specifications similar to a dispersal field,
certification does NOT include management methods for the treated effluent discharged
from the system.
|
||||
NOTE: This Company distributes, sells, installs, or services their own NSF Certified systems.