NSF/ANSI 40
Residential Wastewater Treatment Systems
Residential Wastewater Treatment Systems
Infiltrator Water Technologies, LLC (formerly Presby Environmental, Inc.) | |
4 Business Park Road | |
Old Saybrook, CT 06475 | |
United States | |
800-473-5298 | |
603-837-3826 | |
Visit this company's website |
Facility : Whitefield, NH
Model Number | Rated Capacity Gallons/Day |
Classification | ||
Advanced Enviro-Septic® Treatment System[1] [2] [3] |
||||
AES-CTD-450 | 450 | Class I | ||
AES-CTD-600 | 600 | Class I | ||
AES-CTD-750 | 750 | Class I | ||
AES-CTD-900 | 900 | Class I | ||
AES-CTD-1050 | 1050 | Class I | ||
AES-CTD-1200 | 1200 | Class I | ||
AES-CTD-1350 | 1350 | Class I | ||
AES-CTD-1500 | 1500 | Class I | ||
AES-SPD-450 | 450 | Class I | ||
AES-SPD-600 | 600 | Class I | ||
AES-SPD-750 | 750 | Class I | ||
AES-SPD-900 | 900 | Class I | ||
AES-SPD-1050 | 1050 | Class I | ||
AES-SPD-1200 | 1200 | Class I | ||
AES-SPD-1350 | 1350 | Class I | ||
AES-SPD-1500 | 1500 | Class I | ||
[1] Prefix CTD denotes combined or bottomless discharge. Prefix SPD denotes single point discharge. Prefix AES denotes Advanced Enviro-Septic®. Prefix SS denotes Simple Septic®. Prefix ES denotes Enviro-Septic®. [2] Table A, Minimum Sizing and Dimensions NSF 40 Class I Certified Advanced Enviro-Septic® Models, Simple Septic®, & Enviro-Septic® Models Model Number Design Daily Minimum Minimum Septic Septic Flow Total Pipe Tank Size Length (ft.) (gal.) XX-SPD 450 & XX-CTD 450 450 150 1000 XX-SPD 600 & XX-CTD 600 600 200 1200 XX-SPD 750 & XX-CTD 750 750 250 1500 XX-SPD 900 & XX-CTD 900 900 300 1800 XX-SPD 1050 & XX-CTD 1050 1050 350 2100 XX-SPD 1200 & XX-CTD 1200 1200 400 2400 XX-SPD 1350 & XX-CTD 1350 1350 450 2700 XX-SPD 1500 & XX-CTD 1500 1500 500 3000 Maximum loading of 3.0 gallons per linear foot of AES, SS or ES pipe. Minimum spacing of pipe rows – eighteen inches (18") on center (i.e. minimum one-half foot (6") of system sand between pipe rows). Note: All models include 6 in. of system sand below pipes for treatment. [3] While the Presby treatment system includes design specifications similar to a dispersal field, the scope of the NSF/ANSI Standard 40 Class I Certification does NOT include management methods for the treated effluent discharged from the system. |
||||
Simple Septic® Treatment System[1] [2] [3] |
||||
SS-SPD 450 | 450 | Class I | ||
SS-SPD 600 | 600 | Class I | ||
SS-SPD 750 | 750 | Class I | ||
SS-SPD 900 | 900 | Class I | ||
SS-SPD 1050 | 1050 | Class I | ||
SS-SPD 1200 | 1200 | Class I | ||
SS-SPD 1350 | 1350 | Class I | ||
SS-SPD 1500 | 1500 | Class I | ||
SS-CTD 450 | 450 | Class I | ||
SS-CTD 600 | 600 | Class I | ||
SS-CTD 750 | 750 | Class I | ||
SS-CTD 900 | 900 | Class I | ||
SS-CTD 1050 | 1050 | Class I | ||
SS-CTD 1200 | 1200 | Class I | ||
SS-CTD 1350 | 1350 | Class I | ||
SS-CTD 1500 | 1500 | Class I | ||
[1] Prefix CTD denotes combined or bottomless discharge. Prefix SPD denotes single point discharge. Prefix AES denotes Advanced Enviro-Septic®. Prefix SS denotes Simple Septic®. Prefix ES denotes Enviro-Septic®. [2] Table A, Minimum Sizing and Dimensions NSF 40 Class I Certified Advanced Enviro-Septic® Models, Simple Septic®, & Enviro-Septic® Models Model Number Design Daily Minimum Minimum Septic Septic Flow Total Pipe Tank Size Length (ft.) (gal.) XX-SPD 450 & XX-CTD 450 450 150 1000 XX-SPD 600 & XX-CTD 600 600 200 1200 XX-SPD 750 & XX-CTD 750 750 250 1500 XX-SPD 900 & XX-CTD 900 900 300 1800 XX-SPD 1050 & XX-CTD 1050 1050 350 2100 XX-SPD 1200 & XX-CTD 1200 1200 400 2400 XX-SPD 1350 & XX-CTD 1350 1350 450 2700 XX-SPD 1500 & XX-CTD 1500 1500 500 3000 Maximum loading of 3.0 gallons per linear foot of AES, SS or ES pipe. Minimum spacing of pipe rows – eighteen inches (18") on center (i.e. minimum one-half foot (6") of system sand between pipe rows). Note: All models include 6 in. of system sand below pipes for treatment. [3] While the Presby treatment system includes design specifications similar to a dispersal field, the scope of the NSF/ANSI Standard 40 Class I Certification does NOT include management methods for the treated effluent discharged from the system. |
||||
Enviro-Septic® Treatment System[1] [2] [3] |
||||
ES-CTD-450 | 450 | Class I | ||
ES-CTD-600 | 600 | Class I | ||
ES-CTD-750 | 750 | Class I | ||
ES-CTD-900 | 900 | Class I | ||
ES-CTD-1050 | 1050 | Class I | ||
ES-CTD-1200 | 1200 | Class I | ||
ES-CTD-1350 | 1350 | Class I | ||
ES-CTD-1500 | 1500 | Class I | ||
ES-SPD-450 | 450 | Class I | ||
ES-SPD-600 | 600 | Class I | ||
ES-SPD-750 | 750 | Class I | ||
ES-SPD-900 | 900 | Class I | ||
ES-SPD-1050 | 1050 | Class I | ||
ES-SPD-1200 | 1200 | Class I | ||
ES-SPD-1350 | 1350 | Class I | ||
ES-SPD-1500 | 1500 | Class I | ||
[1] Prefix CTD denotes combined or bottomless discharge. Prefix SPD denotes single point discharge. Prefix AES denotes Advanced Enviro-Septic®. Prefix SS denotes Simple Septic®. Prefix ES denotes Enviro-Septic®. [2] Table A, Minimum Sizing and Dimensions NSF 40 Class I Certified Advanced Enviro-Septic® Models, Simple Septic®, & Enviro-Septic® Models Model Number Design Daily Minimum Minimum Septic Septic Flow Total Pipe Tank Size Length (ft.) (gal.) XX-SPD 450 & XX-CTD 450 450 150 1000 XX-SPD 600 & XX-CTD 600 600 200 1200 XX-SPD 750 & XX-CTD 750 750 250 1500 XX-SPD 900 & XX-CTD 900 900 300 1800 XX-SPD 1050 & XX-CTD 1050 1050 350 2100 XX-SPD 1200 & XX-CTD 1200 1200 400 2400 XX-SPD 1350 & XX-CTD 1350 1350 450 2700 XX-SPD 1500 & XX-CTD 1500 1500 500 3000 Maximum loading of 3.0 gallons per linear foot of AES, SS or ES pipe. Minimum spacing of pipe rows – eighteen inches (18") on center (i.e. minimum one-half foot (6") of system sand between pipe rows). Note: All models include 6 in. of system sand below pipes for treatment. [3] While the Presby treatment system includes design specifications similar to a dispersal field, the scope of the NSF/ANSI Standard 40 Class I Certification does NOT include management methods for the treated effluent discharged from the system. |